syngo CT VB10 Software Update - CARE Dose 4D- Dual Topogram Job Aid
This pdf explains how to adjust the ref. mAs values to reduce the dose, when migrating protocols with dual topogram from one software version to another version.
SIEMENS Healthineers CARE Dose 4D – Updated Dual Topogram Behavior Job Aid Template effective date: 27 May 2019 | HOOD05162003010284 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D SIEMENS Healthineers Table of Contents Single Topogram - Water-equivalent patient diameters (WEDs ) 3 Dual Topogram - Overview 4 SIEMENS Healthingers Dual Topogram - Software Version Overview 5 Dual Topogram – Scan Range 6 Dual Topogram - Adapt Quality ref. mAs 7 SOMATOM go Top Dual Topogram - Adapt Quality ref. mAs values for multiple protocols 8 2 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D – SIEMENS Healthineers Single Topogram - Water-equivalent patient diameters (WEDs) Overview Estimated WED in LAT direction (thorax region) • CARE Dose4D and CARE kV calculations are based on water-equivalent patient diameters 55 (WEDs) 50 • WEDs are usually extracted from a single topogram scan 45 40 • Using AP/PA* topograms, WED in AP direction is measured, WED in LAT direction is 35 estimated and vice versa using LAT topograms 30 Pre-requisites for a reliable WED calculation 25 WED [cm] • Good image quality of the topogram: By using the Siemens protocols you can ensure that 20 topogram kV and mA settings are adequately* selected in order to achieve a good image 15 VAxy 10 quality VBxy 5 Ground truth • Central patient positioning by using the FAST 3D camera for accurate patient positioning O 50 100 150 200 250 300 WED calculation with SOMARIS 7 VBxy in comparison to SOMARIS 7 VAxy position [mm] • Enhanced accuracy of estimated WED in thorax region (example result: see figure) • Enhanced consistency between measured and estimated WED 3 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 *Calculation of WED is independent of topogram settings (kV, mA, Sn filter) as long as topogram image quality is sufficient. Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D – SIEMENS Healthineers Dual Topogram - Overview AP topogram Dual topogram - VBxy Patient • Definition of an organ-dependent preferred topogram direction position LAT topogram • Calculation of water-equivalent patient diameters (WED) based on AP* topogram • Calculation of a patient position profile from the LAT* topogram Illustration of VBxy dual topogram principle • Correction of potential WED calculation inaccuracies due to topogram (de-)magnification in case of patient mis-centering Benefits • High consistency between single and dual topogram modes • Robustness: CARE Dose4D / CARE kV less sensitive on patient positioning and on adequately high dose levels of the LAT* topogram in new dual topogram mode Illustration of the effect of patient positioning. Topogram magnification effects * Applies to protocols with preferred topogram direction AP. In protocols with organ are corrected based on the patient position information of the LAT* topogram. characteristic Brain, Neck, Spine or Osteo, the preferred topogram direction is LAT. In 4 this case, the WED calculation is based on the LAT* topogram and the AP/PA topogram Job aid effective date: 02 FEB 2021 | HOOD05162003162880 is used only for geometric correction of patient position. Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D – SIEMENS Healthineers Dual Topogram - Software Version Overview VAxy (except VA62) VA62, VBxy Shoulder, Thorax, Abdomen, Pelvis, Extremities, Vascular Organ characteristic All Head, Vascular Body, Runoff, Brain, Neck, Spine, Osteo Perfusion Body, Cardio, Respiratory Preferred topogram direction n.a. AP/PA LAT AP/PA topogram Calculation of WED in Calculation of WED in Patient center profile for AP direction AP and LAT directions correction of WED calculation LAT topogram Calculation of WED in Patient center profile for Calculation of WED in LAT direction correction of WED calculation AP and LAT directions 5 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D – SIEMENS Healthineers Dual Topogram – Scan Range Example: Neck protocol (preferred topogram direction LAT) exposure [mAs] 0 50 100 150 200 250 a) If the scan range is not fully covered by a 50 topogram of the preferred direction, WED values 100 150 will be extrapolated and the dose volume may be 200 incorrect. 250 position [mm] 300 b) The extrapolation of WED values of the topogram 350 400 of the preferred direction is also applied if the scan a) scan range fully covered by preferred topogram range is fully covered by a topogram of the non- exposure [mAs] 0 50 100 150 200 250 preferred direction (see example). 50 100 150 Please make sure that the entire scan length 200 250 position [mm] is covered with a topogram of 300 350 the preferred direction. 400 b) scan range not fully covered by preferred topogram 6 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D – SIEMENS Healthineers Dual Topogram – Adapt Quality ref. mAs Due to the improved dual topogram behavior in VBxy, a migration of protocols from one version to another version can affect dose levels. Transfer of dual topogram protocols Therefore the migration of protocols from the previous SOMARIS 7 VAxy version to VA VB any VBxy version requires an adaption of the Q. ref. mAs values in the following cases: 1. Transfer of all protocols with dual topogram (AP + LAT) → reduce Q. ref. mAs by 30% Please note: This does not apply to VA62. The new Dual Topogram behavior is already implemented in VA62. Transfer of LAT topogram protocols 2. Transfer of protocols with a single LAT topogram → reduce Q. ref. mAs by 15% VA VB 3. Transfer of cardio protocols with AP topograms → reduce Q. ref. mAs by 15% Please note: The above-mentioned Q. ref. mAs adaptations serve as a first guideline Transfer of cardio protocols with AP only. Please ensure that all dose relevant parameters (protocol and configuration) are topogram carefully finetuned so that individual image quality needs are fulfilled. VA VB 7 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D – SIEMENS Healthineers Dual Topogram - Adapt Quality ref. mAs values for multiple protocols 1. Open the Scan Protocol Assistant from 3. Select Next . the top of the screen via Options > Configuration > Scan Protocol 4. Then you can select individual protocols, Assistant. which contain dual topogram. Qotions System Help Scan Protocol Assistant Versión ... 3 5 License Connect to syngo.via O Aduit Child Life Card print number Select all protocols 7 Axial recon jobs Protocols with ECG Protocols with dual energy Customized scan protocols 3D recon jobs Protocols with duel source Interventional protocols Siemens default protocols Ejle Browser. IRIS recon jobs Respiratory protocols Protocols for workflow MI Protocols for data role Head Spine Vascular Dual Energy Switch to External Simulator Head_XCARE. C_Spine_IRIS HeadAngio_X .. DE_Thorax Head IRIS C_Spine HeadAngio IRIS DE_Thorax Head_XCARE Spine_IRIS HeadAngio_X DE_Thorax F Hide Simulation Taskcard HeadRoutine SpineRoutine HeadAngioRou DE_Thorax. HeadNeuro DSXXL_Spi HeadAngioVol DE_Abdom ... HeadSeq_XCA. SpineNeuro NeuroDSACT Neck Thorax Maintenance Specials Neck_IRIS Flash_Thora Flash_Trauma NeckRoutine Flash_Thorax Trauma NeckThorax Thorax XCAR TraumaThin Auto Expose Shoulder Thorax_IRIS ** PolyTrauma Thorax XCARE Flash_Head .. ShoulderRoutine Abdomen RT Cardiac Configuration +01 AbdMultiPh RT_Head 01_Flash .. Abdomen IRIS RT_Thorax Flash CaSc .. Upper Extremities AbdomenRoutine RT_Breast DS_CaScore WristZUHR RT_Abdomen @DS_CaScor ExtrZUHR RIS SOSXXL_Ab AbdMultiPhase RT_Pelvis Flash_Cardi Service ExarRoutineZUHR AbdomenSeq RT_RespSeq Flash_Cardio Lower Extremities PeMs KneeUHR Pelvis_IRIS FootUHR PelvisRoutine ExtrZUHR IRIS @DSXXL_PeMs ExtrRoutineZUHR Hip BOUHR 2. The guided workflow assists you in making the desired changes. 5. Select Next . 2 3 4 5 What do you want to do? 8 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021 CARE Dose 4D – SIEMENS Healthineers Dual Topogram - Adapt Quality ref. mAs values for multiple protocols Scan Protocol Assistant x 6. Go to the Scan field. 1 2 3 4 5 7. Select the Find/Replace option at the bottom .... .... 6 Change parameters of the window. This tool helps you to change Protocol Topogram Scan Recon Auto tasking Trigger Intervention Contrast parameters in multiple series very quickly. Including topogram Range Quality Quality Quality (Eff.) ((Eft.) (Eff.) CARE Dose Dose Cycle Rotation name Mode kV ref. mAs ref. mAs(A) ref. mAs(B) mAs mAs(A) | mAs(B) type modul time time | Collimation | Slice Head / HeadRoutine_IR (Adult) 8. Highlight the column Quality ref. mAs by Topogram: 20mA, 256mm, LAT, Craniocau Jal Head Spiral 120 273 273 CARE Dose4D on 1 s 0.6mm 5mm Neck / NeckRoutine_IR (Adult) clicking on it. Neck Topogram: 20mA, 256mm, LAT, Craniocau Jal Spiral 120 116 116 CARE Dose4D on 1 s 0.6mm 5mm Thorax / ThoraxRoutine_IR (Adult) Thorax Topogram: 20mA, 512mm, AP, Craniocaud 9. Select Special Task. Spiral 120 66 Abdomen / AbdomenRoutine_IR (Adult) 99 CARE Dose4D on 0.5 $ 0.6mm 5mm Topogram: 20mA, 512mm, AP, Craniocaud 10. Select Decrease value by x% in the Abdomen Spiral 120 147 147 CARE Dose4D on 0.5 $ 0.6mm 5mm dropdown menu and enter 30%. 8 11. Select Replace All to replace all Select All Sequence scans Spiral scans Multiscans Interventional scans Adaptive 4D spiral scans Quality ref. mAs values of the selected i-Sequence i-Spiral i-Fluoro Selected column: Quality ref. mAS 9 protocols. Set Find / Replace Special Task Value Find Special Task Decrease value by x% Replace 30 % Find next Replace all 10 Replace 11 7 9 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 10 Job aid effective date: 02 FEB 2021 | HOOD05162003162880 Unrestricted © Siemens Healthineers, 2021
- CT
- Dual Topogram
- system upgrade
- transfer
- VB10
- syngo
- radiology
- reduce
- dose
- ref
- mAs