UI Navigation for Physicists Step by Step
SOMATOM go. UI Navigation for Physicists Step by Step
SOMATOM go. UI Navigation Tool for Physicists With the introduction to our new SOMATOM go. systems there is a new software interface that may be unfamiliar to most. With strict quality control regulations in place by hospital, state, and country, physics testing on these systems has become an annual requirement. Due to this, physicists are required to run tests on the go. systems and may not be familiar with the software. These tests include CTDI dose measurement testing and require specific protocols to be used for this testing. The purpose of this how-to-workflow is to show physicists how to access hidden, dedicated testing protocols for CTDI measurement testing on the SOMATOM go. system. The steps covered in this guide (and video) will show one how to un-hide CTDI measurement protocols for both adult and pediatric body and head modes. The guide (and video) will further show the steps to register a patient, choosing the CTDI protocol(s) and selecting the various parameter settings for any protocol modification purposes. The user can then proceed to acquire the scan for testing. NOTE: Prior to initiating this task, ensure that you have acquired the Super User login credentials from the Lead Technologist or designated resource in order to complete this task. This will include the login ID and password. 1. Log in as a super user by selecting the drop down list in the top right corner. From the drop down list, select Super User. SIEMENS Healthincers meduser ? meduser = Scan 5 = Recon 3 O super us mary roie: Technologist other useer Scheduler meduser ? Search by Name, to. Coll. Description, Procechine Omlo. Ace No Q meduser Patients Scheduled for Last 2 Days (0 result(s), 9:23:39 AM) c + super user Patient Procedure Date and Time other user Exam Emergency Register Delete Patient Patient 2. Enter the password to log in as Super User. SIEMENS ..... Healthineers G syngo CT VA20A administrator Password Domain CT119951 OK Cancel Change Password. Copyright @ Siemens Healthcare GmbH 2018. All rights reserved. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Job Aid | SOMATOM go. UI Navigation Tool-Physicist Effective Date: 05/28/2020 | HOOD05162003085189 3. From the Scheduler window – click on the settings icon (aka Cog Wheel) 4. From the drop list, Select Exam Designer. SIEMENS Healthineers f ) = Scan 5 E Recon 3 X administrator Scheduler Configuration Panel Administration Portal Search by Name, ID, DoB, Description, Procedure Date, Acc No. and Modality (C. Q Clinical Configuration Check up Patients Scheduled for Last 2 Days (0 result(s), 10:17:00 AM) Daily QA Calibration If Patient Y Procedure Date and Time Resume syngo Remote Assist Screen recorder SaveLog Remote Service Exam Designer Create Screenshot 5. The Exam Designer Tab appears with the Select Protocols sub tab displayed. Select Siemens Protocols (upper left corner). Note: You can deselect Customer Protocols if you wish – this will remove all customer protocols so it is easier to identify Siemens default protocols. Healthineers = Scan 5 = Recon 3 O Exam Designer Select Protocols Modify Protocols Confirm Changes Siemens Protocols (117) * Customer Protocols (2) Adult Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 8 Job Aid | SOMATOM go. UI Navigation Tool-Physicist Effective Date: 05/28/2020 | HOOD05162003085189 6. Select Specials Folders for both Adult and Child protocols. Trauma Trauma RTP RTP Specials SpeciNy's Intervention Baby 7. Check the boxes for the CTDI measurement protocols under both Adult and Child. Adult Child Specials (2) Specials (2) @ ml v CTDI measurement Head CTDI measurement Head G ml " CTDI measurement Body CTDI measurement Body 8. Select Unhide at the bottom left. This will display the protocols in the Examination Card for use. 9. Close the window by selecting the X in upper right corner of the window. 10. Click Examination. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 8 Job Aid | SOMATOM go. UI Navigation Tool-Physicist Effective Date: 05/28/2020 | HOOD05162003085189 11. Select Register Patient in the upper right corner. In the Patient Registration tab, enter the a Last Name, Patient ID, and DOB. - Click Exam in lower right corner. - The “Application is starting. Please Wait” message appears while the Examination card - loads. Patient Registration Create a new entry in the Patient List Medical Information Exam Information * Last Name| Admitting Diagnosis First Name Requested Procedure Title Description Suffice Alerts Accession No Middle Name Medical Alerts ID . Patient ID Comments " Date of Birth Munyyyy M/d/yyyy Allergies Age Year(s) Sex Height Institution Weight Ibs U.S. Operator 12. When the Examination Card opens the Protocol Selection tab will display. To select the “unhidden” CTDI Measurement Protocols for either Child or Adult, click - on the Specials folder then click on the Protocol (Head or Body). Cit . 1/17/2020 (0) 607 Protocol Selection Protocol Parameter Patient Information Weight Physiological Signal Age days Height Sex CREA ECO DenG Requested Procedure Protocol: CTDI measurement Head Proto Patient Type -Indications: special head protocol for ACR Topogram Contrast Protocol accreditation -Scan modes: RoutineSequenceAdultHead Head syngo via Adult Child Protocol: CTDI measurement Body -Indications: special body protocol for ACR accreditation Scan modes: RoutineSequenceAdultAbdomen SpeCIA Intervention Dynamic Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 4 of 8 Job Aid | SOMATOM go. UI Navigation Tool-Physicist Effective Date: 05/28/2020 | HOOD05162003085189 13. Click the Add icon to register the protocol. 14. Click OK in bottom left corner to apply the protocol. Apply protocol Confirm Cancel 15. Right mouse click on the scan timeline and select Show Parameters. All scan parameters can be verified/changed under the various tabs. - Show Parameters Delete Repeat Open Edit Mode Create Image with Reference Lines 2s II 5s Scan Favorites General Scan Dose Timing Config Physio Scan Contrast Scan/Recon Patient Organ Characteristic Target Region Scan Mode Tilt [o] Acquisition Imml Scan Direction Table Feed No. of Type Direction [mm] Scans Body Adult Abdomen Abdomen RoutineSequenceAdultAbdomen 64 x 0.6 Head to Feet In 34.5 3 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 5 of 8 Job Aid | SOMATOM go. UI Navigation Tool-Physicist Effective Date: 05/28/2020 | HOOD05162003085189 16. Left mouse click on the orange Recon square in the top right corner. This will then display all of the Recon parameters. Recon Ranges Topogram Body 5.00 Br40 Slice Thickness 5.00 Increment 5.00 Image Orientation Axial Kernel Br40 Window Soft Tissue Recon Favorites General Rrcon Image Impression Recon Box Physio Recon Auto Tasking Recon&GO Scan/Recon Inline Results Slice Thickness Increment No. of [mm] [mm] Images Image Order Comment 1 Comment 2 5.00 Br40 None 5.00 5.00 20 Head to Feet To make changes to the reconstruction parameters, click on the desired recon tab and - make the necessary change. Choose from one of the recon tabs to make any adjustments to the recon parameters. - 17. Select Confirm to load the protocol and then Go to activate topogram scan mode. Confirm patient position Activate Topogram scan Confirm OK Cancel Confirm GR Cancel 18. The next step will be to acquire the scan for testing. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 6 of 8 Job Aid | SOMATOM go. UI Navigation Tool-Physicist Effective Date: 05/28/2020 | HOOD05162003085189 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 7 of 8
- UI Navigation