3D DR Examination Sequence
3D DR Examination Sequence
3D DR Examination Sequence Interventional Radiography: Cardiac Preparations 3D DR test phase. You check that the programmed rotational range is free of obstacles and hazards Injection if contrast medium is used 3D DR fill phase. An image is acquired for every projection Image data is sent to the syngo Workplace. The 3D image is recon- structed and displayed (2) (6) (4) (7) (5) (1) (3) Steps 1. Start position: Optional: Brief fluoroscopy to check the examination region. 2. Test run with rotating C-arm for ensuring that no collisions occur. 3. Brief fluoroscopy for automatic setting of acquisition parameters. 4. Injection if contrast medium is used. 5. Start of acquisition. 6. Fill run with rotating C-arm for image acquisition with or without contrast medium. 7. End of acquisition. SIEMENS siemens.com/healthineers Healthineers . Job Aid | 3D Dr Examination Sequence Effective Date: 09/08/2016 | Qualitry HOOD05162002274295 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2
- Artis One
- Artis Q
- Artis zee biplane
- Artis zee ceiling mounted
- Artis zee floor mounted
- Artis zeego
- Artis Zen
- syngo Multimodality Workplace