3D DR Large Volume Sequence (Zeego)
3D DR Large Volume Sequence (Zeego)
3D DR Large Volume Sequence Interventional Radiography: Zeego A 3D DR - Large Volume acquisition is performed in the following sequence: 1. Prepare the patient, stand, C-arm and table. Check the injector, if used. 2. Select a 3D DR - Large Volume acquisition program. 3. Position the region of interest in the isocenter. 4. Move C-arm to start position: Press down the stand joystick and deflect it. 5. Perform the 3D DR - Large Volume test run 1 and 2 to make sure that no collision will oc- cur. 6. Perform a brief fluoroscopy for automatic setting of ac- quisition parameters: Press fluoro pedal of footswitch. Ready for 3D: #s Acquisition Time is displayed. 7. Automatic or manual injection if contrast medium is used. 8. Perform the 3D DR - Large Volume acquisition runs 1 and 2: Start acquisition: Press the acquisition button on hand switch or pedal and keep it pressed. Rotational run will start automatically, if Auto is pro- grammed. Press the multifunctional button of the handswitch, if Manual is programmed. Injection will also be performed automatically if the injector is set to "Armed." 9. Let go of the acquisition button when all rotational runs are complete. (Acquisition is stopped automatically.) 10. Transfer of image data to the syngo Workplace: Automatically after the acquisition Manually as long as data is available on the Artis 11. Visualize using the InSpace task card or 4D task card (PURE systems). SIEMENS siemens.com/healthineers Healthineers Job Aid | 3D Dr Large Volume Sequence Effective Date: 09/06/2016 | Quality HOOD05162002274297 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2
- Artis zeego