3D DSA Examination Sequence

3D DSA Examination Sequence

3D DSA Examination Sequence Interventional Radiography: Cardiac Preparations  3D DSA test phase. You check that the programmed rotational range is free of obstacles and hazards 3D DSA mask phase. A mask image is acquired for every projection   Return phase  Injection  3D DSA fill phase. For every projection, a fill image is acquired and the mask image is subtracted from it (S) 19) (3 ) Steps 1. Start position: Optional: Brief fluoroscopy to check the examination region. 2. Test run with rotating C-arm for ensuring that no collisions occur. 3. Brief fluoroscopy for automatic setting of acquisition parameters. 4. Mask run with rotating C-arm for image acquisition without contrast medium. 5. Reversal in the start position of the test run. 6. Return run. 7. Injection at reversal point. 8. Fill run with rotating C-arm for image acquisition with contrast medium. 9. End of acquisition. SIEMENS siemens.com/healthineers Healthineers . Job Aid | 3D DSA Examination Sequence Effective Date: 08/15/2016 | Quality HOOD05162002274308 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2

  • Artis One
  • Artis Q
  • Artis zee floor mounted
  • Artis zeego
  • Artis Zen