3d/3d Fusion
3d/3d Fusion
3D/3D Fusion Interventional Radiography Cardiac & Vascular Please refer to manual for complete system capability 1. Prior to the day of the exam (if possible) Import existing CT/MR/PET scan and load into InSpace tab. Post process with VOI punching ("cut away" any unnecessary information) and save as a Bookmark Example: EVAR: Cut away everything except the aorta, bilateral renal arteries, bilateral iliac arteries and bilateral hypogastric arteries. 2. Day of the exam Load in CT/MR/PET dataset from above step into the InSpace tab. Perform a low dose 5sDR spin. This spin will be used for bony landmarks to fuse/merge with the open CT/MR/PET dataset. This will automatically load into the InSpace tab and you will be able to go directly to Fusion from here. Click on the Fusion icon in the Tools subtask card of the InSpace tab. Select Manual or Auto Registration to superimpose the two datasets. Page 1 of 4 Job Aid | 3D/3D Fusion Effective Date: 09/08/2016 | Quality HOOD0516200893402 3D/3D Fusion x 3D/3D Fusion X Volume Selection Volume Selection Registration Registration Registration Matrix Default Relistration Matrix Default Registration Mode Registration Mode auto auto Manual/Visual Registration Automatic Registration Fully automatic (pre-registration done by application) Pre-aligned (takes pre-registration of the user into account) AAVP Hint It is recommended to register the buo volumes roughly per Manual/ipual Reputation before using thia registration mode Start Automatic Registration: VV Register Help Close Help Close Save it by clicking on the floppy disk icon in the upper right corner of the gray box. This is very important-if you forget to do this, you will not have a fused image. 3D/3D Fusion X Volume Selection Registration Registration Matrix Default Registration Mode auto Manual/Visual Registration I AAVV A Help Close Page 2 of 4 Job Aid | 3D/3D Fusion Effective Date: 09/08/2016 | Quality HOOD0516200893402 Fusion is complete! If your physician wants to use iPilot functions, re-load your Bookmark (using Step 1) back into the InSpace tab. This Bookmark now knows where your patient is on the table and can be utilized for this function. The following message may display. The user confirms the message if the patients are identical. Pilot Live X Mo_CT_Standard_Heart_Abd, 19190402. F. 1234 of the currenty selected volume difiers from last reconstructed 30Angio f DinaCT data set Confirm the patients are identical OK Cance *** Remember: Fusion is nothing more than merging ANY two 3D datasets together. Two InSpace/DynaCT volumes can be fused as well. iPilot Live and Dynamic, iGuide Needle Guidance, etc. can be used independently of Fusion on cases that don't have an existing CT/MR/PET scan. Perform an appropriate 3D spin, on the day of the exam, and perform appropriate software workflow. Page 3 of 4 Job Aid | 3D/3D Fusion Effective Date: 09/08/2016 | Quality HOOD0516200893402 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ........... ....... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Page 4 of 4
- Artis zee biplane
- Artis zee ceiling mounted
- Artis zee floor mounted
- Artis zee multi-purpose
- Artis zeego
- Angiostar
- Axiom Artis