ACUSON Bonsai Stress Echo Quick Card
This Quick Card demonstrates how to preform a Stress Echo on the ACUSON Bonsai System
Quick Reference Card Stress Echo Workflow ACUSON ACUSON Bonsai Ultrasound System Bonsai® Step 1 Step 5 To Acquire Select Stress Echo (P9 on QWERTY keyboard). In Select Mode, using • • trackball, with your Set Set cursor, point to an image P8 Stress Echo Physio Setup to select one or more images, then select Set. ...... Step 2 TIP Checkmarks will be placed next to Select Stress Echo type. the view when image is selected. • Treadmill Two Stage Auto Select (2x4) is most common. • Select OK. Step 6 To Acquire • Select the To Acquire • button or use Mode to Set Set Step 3 return to imaging screen. ROI (Region of Interest) will appear. Use trackball Acquire WMS • Repeat until all resting Select • and select keys to change ROI. images are acquired. TIP This is the only chance to set ROI size. Ensure ROI covers desired anatomy. TIP The stress echo package uses three modes: Acquire, Select, and Review. To re-image a step, toggle to Acquire, choose View, select Save to Step 4 recapture and choose a new view. Select Update key to confirm ROI size. • This will begin acquisition mode. Step 7 VIEW When ready to obtain images press Save. If desired, with the cursor, • (1) PLAX • select the Review/WMS (1) PSAX PLAX to review selected Resting images. (1) A4C PSAX (2) A2C TIP A Red dot appears next to image being acquired. Upon acquisition of each view, the program will Step 8 automatically advance to the Select Mode. After all the Resting images have been acquired, the • system is automatically ready to acquire the Post Exercise images. All Post Exercise images are acquired in continuous • capture. SIEMENS Healthineers siemens.com/bonsai HOOD05162002809504 Step 9 Post Step 12 Stress Echo Select Save to start 13% Once all Post images Acquire • • capturing images. are chosen, go to Select Select Freeze to pause capture. Review / WMS. Review / WMS • Select Freeze again to resume. Rest images will be Play • • If additional images are required outside the stress echo displayed first. • protocol (i.e. spectral Doppler), select Suspend Exam. 7 10 10 TIP Percentage memory will display when capturing Post images. Timer can be manually started using Soft keys if desired. 12 12 8 Step 10 11 9 11 9 10 10 Select Save when all images have been obtained • to stop acquisition. Step 13 To view Post images use the soft key screen button • TIP Re-acquisition of post images is not possible at this point. labeled Stages: Rest / Post. To compare rest and post images, use soft key labeled • Shuffle On /Off. Step 11 VIEW To navigate through the images, use the Shuffle Back / • Post continuous capture (0) Shuffle Forward. • PLAX images will be displayed. (0) PSAX To Acquire Mode: Choose the view to the • (0) A4C Stages: Views: Shuffle Mode Set Set Review / Shuffle Back Rest PLAX right of the screen, and On WMS Shuffle Forward A2C with the Set key, choose (0) Acquire Select WMS the image you want to assign to that view. TIP Images are displayed in the order acquired. Step 14 Delete Unselected To end exam, choose Delete Suspend Exam • Unselected in order to save End SE Exam only the selected views. Select End SE Exam to finalize and exit. • TIP User cannot suspend the Stress echo exam, and then end the study. Stress echo must be ended in order to end the entire exam. Stress echo is a program within a preset. ACUSON Bonsai is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Distributed By Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 685 East Middlefield Road Phone: +49 9131 84-0 Mountain View, CA 94043, USA siemens.com/healthineers Phone: +1-888-826-9702 siemens.com/ultrasound Manufactured By Shenzhen Mindray Bio-Medical Electronics Co., Ltd. Published by Siemens Medical Solutions USA, Inc. · Order No. A91US-491-1C-4A00 · Printed in Germany · 5795 0218.xx · © Siemens Medical Solutions USA, Inc., 2018 HOOD05162002809504
- ACUSON Bonsai Stress Echo Quick Card