PEPconnect

ACUSON Juniper™ Ultrasound System Configuration Training - VB10 | 1.5 Software

This course will be a high-level overview and navigation of the ACUSON Juniper™ ultrasound system configuration menus.

Continue Continue HOOD05162003144731 | 3-Dec-2020 ACUSON Juniper™ Ultrasound System Configuration Online Training – VB10 | 1.5 Software This training will cover the ACUSON Juniper ultrasound system Configuration menus. There are the two learning objectives for this online training. Explain the system configuration navigation 1 Review the system configuration menu 2 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 ? Welcome Base layer: welcome: config_1.mp3 Welcome to the ACUSON Juniper Ultrasound System Configuration online training. This training will cover the ACUSON Juniper Ultrasound System Configuration menus. There are two learning objectives for this online training. System Configuration The configuration menus and options are used to modify and customize a variety of settings. Select the numbered steps below to review some of the System Configuration settings on the ACUSON Juniper system. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 ? System Configuration Base layer – System Configuration: 1.2.mp3 Next, you will review the Configuration menus and options that are used to modify and customize a variety of settings on the ACUSON Juniper system. Select the numbered steps below to review some of the System Configuration settings on the ACUSON Juniper system. 8 System Configuration Menu Options Please select each of the markers throughout the Exam menu of expanded descriptions. Freeze and Dual Freeze Behavior - assigns a function (i.e., Caliper, Cine, Text, Arrow, or Body Marker) when the image is frozen. Seamless Dual - enables or disables the seamless display for Dual. Dual Behavior on Freeze - assigns the behavior of Dual mode when image is frozen. Left Dual Image Live – when Dual is activated, this lets you choose to display the 2D live image or active image on the left side of the screen and the right side of the screen is not live or not active. The default for Dual is a 2D live image on the right side of the screen and the left side of the screen is not live or active. End-Diastole (ED) to End Systole (ES) - ED-ES Split - displays an end-diastolic frame and end-systolic frame. eSieImage™ Multiparametric Optimization This simply enables or disables eSieImage for the exam. eSieImage can be enabled or disabled for each preset. Auto Invert, 2D Steer, and 2D field of view (FOV) with Color Activation This section enables or disables the following selections: Auto Invert of Color While Steering Auto Invert of Color and Spectrum 2D Steer with Cursor Auto 2D FOV with Color Activation Physio Management This assigns the lead type for use with the physiologic function. 3D and 4D Default Selection These assign 3D or 4D activation to the 3D / 4D control. Doppler and M-Mode This section allows for the following selections: 2D / M & 2D / Doppler Display Format - assigns the image screen layout when two imaging modes are active Doppler Update Style - assigns the display of the 2D image during Doppler (frozen or live), or the interval for updating the 2D image Doppler Auto Stat - enables or disables the default display of measurements and graphical traces to track mean and/or maximum velocities or frequencies Doppler Trace Orientation - select trace above or below the baseline, or both 6 System Configuration Menu Options The Soft Keys menu customization is available for the Touch Screen and Soft Key controls for both live and frozen states in 2D, color Doppler, power Doppler, M-Mode, and pulsed wave Doppler modes. Some choices may not be available for both live and frozen. This is the display for 2D Live. Selections are available from the drop-down menus. The next page will review customizing the Touch Screen. 7 System Configuration Menu Options To assign a new selection to the Touch Screen or Soft Keys, use the following steps: Select the required position for the selection Select the required label from the drop-down list To remove a Soft Key selection: Select the required label Then select ‘Blank’ from the drop-down list System Configuration Menu Options Please select each of the markers throughout the Custom Keys menu of expanded descriptions. 5 Key Direction for Zoom, Depth, and Focus Increase Zoom - assigns a clockwise or counterclockwise rotation to the control to increase the magnification factor. Depth / Focus - assigns a clockwise or counterclockwise rotation or upward or downward movement to the control to adjust the imaging depth or focus. Print, Store, and Clip Store Print / Store 1 and 2, assigns the required functions to the selected control on the control panel. Clip Store, Image Store and or Clip Store functions are allocated to the Clip Store key. Foot Pedal (Optional) Assign functions to each pedal on the optional foot pedal. User-Defined (UD) This assigns a function to UD1, UD2, and UD3 keys on the control panel. Configure END Key These are functions to the “END” key which is located on the retractable keyboard (option): “Not Used” disables the key on the keyboard “Close Study” closes the current study System Configuration Menu Options 4 Please select each of the markers throughout the Display menu for expanded descriptions. Monitor The screen saver will be enabled or disabled. The time delay before the screen saver is activated is configured in this area. This is also where you can select the background for the screen saver. Depth Gain Compensation (DGC) The graphic indicating the DGC curve may be inverted along with the image. Set the DGC curve display to off, always on, or time out (temporarily displayed after edits to the DGC). Additionally, the DGC control image depth setting may be matched to the current image depth or maximum image depth. Thermal Index Display This allows the selection of thermal index during the neonatal head exam, e.g., the thermal index for soft tissue (TIS), the thermal index to the bone (TIB), or the thermal index for cranial bone (TIC). Doppler and M-Mode When the Bypass Cursor Mode is checked the M-Mode sweep or Doppler spectrum will display immediately. When the Bypass Cursor Mode is unchecked, the M-Mode or Doppler cursor appears on the 2D image and then a second press of the mode control displays the sweep or spectrum. Doppler Frequency / Velocity - allows selection of the Doppler spectrum in units of frequency (Hz) or velocity (cm/s). Doppler Auto Optimization - allows the selection of the parameters (Gain, Dynamic Range, Auto Invert, Scale / Baseline) to use with Doppler auto optimization technology (Auto TEQ™ Doppler). System Configuration Menu Options 3 The next menu option is General 2. Please select each of the markers throughout this menu for an expanded description of the General 2 menu. Patient ID In this section the following selections are made: The patient demographic page is stored as the first image of study Patient banner information may be hidden or displayed as a default Either patient age or date of birth are be displayed The patient registration form is displayed as a long form (default) or as a short form (when only limited information is required) Common Mode You may choose to delete the Text and Body Marker when the image is unfrozen. The default Body Marker location can be selected (upper right or lower right). The default Text font size (14-22) may be selected and the default Arrow type, size, and color is chosen from this area. Image Store Store Image with Caliper - enables or disables the display of measurement markers with a saved image. Standard Video or S-Video This section allows a choice for S-Video out in the National Television System Committee (NTSC) or Phase Alternate Line (PAL). The first System Configuration menu option is General 1. Please select each of the markers on this menu for and expanded descriptions of the General 1 menu. System Configuration Menu Options 2 Organization In this section, the user can add or remove the institution name that will appear on the patient banner. Regional Settings This section allows you to configure system settings by region, i.e., language options for the ultrasound system user interface screens, language characters for the Touch Screen, keyboard, date and time display format, current date and time and time zone for your region. Units for height and weight can also be selected. Changes made require a system restart. Audio In this section, the audio beep can be enabled / disabled when a control panel key is pressed, or an image / clip is stored. The volume for the beep and the default Doppler volume can also be configured. Trackball Behavior In this section, the trackball speed is adjusted. The default is medium. System Start-Up The default transducer port for power-up can be selected here. System Shut Down Select whether a confirmation dialogue window appears when system shut down is selected. System Configuration Navigation Select the System Configuration gear icon on the Touch Screen to access the Configuration menu of options. Use the System Configuration settings to modify factory default settings or to customize the current settings. Next, use the Trackball and either Set key to navigate menu options; the active selection is highlighted in blue. Last, select Close (shown here framed in orange) to save changes and exit the System Configuration menu. 1 System Configuration This course continues with the next group of System Configuration menus. Select the numbered steps below to review more configuration settings. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 ? System Configuration Base layer – System Configuration: 1.3.mp3 This course continues with the next group of System Configuration menus. Please select the numbered steps below to review the next group of Configuration settings. 8 Barcode Barcode settings require a connected barcode reader and the facility's representative barcode sample to map into the patient registration form. Select each marker for more information. Scanned Data This displays the characters transferred from the scanned barcode sample (the position of the cursor is listed beside the barcode characters). Offset This is the location to designate the starting position for the bar code reader. Length Enter or modify the character length of the selected field (supports up to 65 characters). Sample Text The sample text can be entered or modified here. Check Boxes Enable or disable the selected entry field (i.e., Last Name, First Name, Patient ID, Performing MD, Sonographer, Accession No.) for use with the barcode reader. Use Separator This enables or disables a separator for each barcode entry field; enter a character in the text box (you cannot use letters or numbers as separators). Set This confirms the offset and length of each of these values. Order Specifies the sequence of information. This is available when “Use Separator” is also activated. Card Reader Setting Specifies the card reader settings to provide the direct entry of patient information in the registration form: Scanned Data - displays characters from the scanned card reader sample Patient ID - displays the patient identification number transferred from the scanned card reader sample Printer 7 The next menu option is Printer. Select each marker for a description of the printer options in this menu. Printer This section provides a drop-down list to select the installed printer options. Thumbnails Printer This section assigns the output devices for printing the thumbnail images. The next menu option is Clip Store. Select each of the markers for more information about the clips store menu. Clip Store 6 Compression This setting specifies the level of image compression and file size. Choices are Low, Medium, or High. The default is low. Clip Store Capture Type Prospective - indicates a clip capture of the succeeding image. Retrospective - indicates a clip capture of the previous image. Clip Length Time - indicates the time of each clip. Beat - indicates the duration of each clip in heartbeat cycles from the electrocardiography (ECG) signal. R-wave only – This indicates the capture point based on a delay beyond the R-wave of the ECG signal. Acquisition Rate This setting defines the frame rate or frames per second (fps) of the acquisition: Normal = 30 fps High = 60 fps The Acquisition Rate setting is changed to High prior to collecting cardiac strain views. eSieScan™ Workflow Protocols The next main menu option is eSieScan protocols. The eSieScan protocols are customized and created here. 5 Stress Echo 4 The next main menu option is Stress Echo which configures selections for exercise and pharmacologic stress echo preferences. Body Marker 3 The next main menu option is Body Marker which configures selections for predefining body marker preferences. The next main menu option is Text Annotation which configures selections for predefining text preferences. Text Annotation 2 Measurement The next menu option is Measurement which configures selections for predefining measurement and report preferences. 1 System Configuration In this final set of menus, we will explore connectivity and security configurations. Select the numbered steps below to review the connectivity and security menus on the ACUSON Juniper system. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 ? System Configuration Base layer – System Configuration: 1.4.mp3 In this final set of menus, we will explore connectivity and security configurations. Select the numbered steps below to learn how to navigate the connectivity and security menus on the ACUSON Juniper system. Service 7 The next menu is Service. Select each of the markers shown here for more information on the service menu. System Information This section provides the system serial number, software version number, and detailed information about the installed software. Service Menu Displays the “Siemens Healthineers Service Software” window. Back-up and restore of Configuration settings and user-defined exam settings is found in this menu. Note: For additional information on back-up and restore, please refer to the ACUSON Juniper Ultrasound System | Getting Started presentation. Remote Displays the “Remote Service Access Control” window. Restore Factor Settings This section will restore the original factory settings to the Juniper system. Remote Assistance Provides information required for a remote service session. A Siemens Healthineers representative guides you through each session of virtual communication. Select the user login icon to login or logoff the ultrasound system. The icon can be turned off by the service representative (system configuration and security settings). Usernames and passwords default to: Admin is Sonographer is Emer is Usernames and passwords are configurable by the Administrator (Admin). Security Login and Logoff 6 Security The next menu option is Security. Select each of the markers for more details about the security menu. Note - Some selections are only available for the ultrasound system administrator or an authorized Siemens Healthineers service representative. For further information, please refer to the ACUSON Juniper Ultrasound System | System Reference manual. 5 Security Health Enabled and disabled security features are shown here. This area provides the security status of the features listed under “Security Health” – a check mark indicates an enabled feature and an “X” indicates a disabled feature. Configure Assign the roles and functional privileges based on user login can be configured in this section of the menu. Pages, Controls, and Passwords Users - individuals that have access to the system through login. Roles - a classification for a user account, providing access to functions or tasks on the system for multiple users. Password complexity and account policy can be configured by the administrator. Archive 4 In the Archive menu, there are options to manage studies saved to the hard drive. Select each of the markers for more information about the Archive menu. Options for Deleting Archived Studies Select one: Delete Study History after Study is Deleted Manually Delete Study History after Study is Deleted Keep Study History after Study is Deleted Show Deleted Studies in Browser This enables or disables the display of deleted studies in the patient browser. Copy Showcase to External Media This enables or disables the automatic storage of the Digital Imaging and Communications in Medicine (DICOM) viewer software program with DICOM-formatted data archived to the external media. Utility 3 The next menu option is Utility. This is where the clip playback and slide show features are configured. Select each marker for more information. Clip Playback Here you can enable or disable the clip playback: Play only Active Clips - disable the simultaneous playback of all clips in the current study Play All Clips – enable the simultaneous playback of all clips in the current study Loop Aligned – align each clip playback to all cycle at the same time Slide Show Here you can enable or the image duration and the number of replay loops: Image Duration (seconds) - specifies the length of display for each image Number of Replay Loops - specifies the number of times each clip is played back These are the menu options in the Network menu. Network 2 Wireless This page displays the menu options for the Wireless function. 1 Course Review Congratulations. You have completed the ACUSON Juniper System Configuration Online Training. Select the objectives below to review the material. 1 1 1 2 Explain the system configuration navigation Review the system configuration menu ? Course Review Review The System Configuration Menu The Soft Key menu and Touch Screen are customizable for all imaging modes including 2D, color Doppler, power Doppler, M-mode, and spectral Doppler modes Customizations for the Soft Key menu and the Touch Screen may not be available for frozen and/or live imaging in all 2D and Doppler modes Configuration settings define cursor behavior in M-Mode and Doppler modes Manage user accounts, system back-up, and touch screens for each operating mode System user and administrative log on settings are managed in the configuration menu Usernames and passwords are configurable by the Administrator (Admin) Explain The System Configuration Navigation System Configuration menus and options are used to modify and customize the display, user interface, and exam settings on the ACUSON Juniper system Access from gear icon on the Touch Screen to access the menu of options used to modify or customize factory default settings Use the trackball and either Set key to navigate menu options Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. ACUSON Juniper is a trademark of Siemens Healthineers. Auto TEQ image optimization, eSieScan protocols, and eSieScan Optimization are trademarks of Siemens Medical Solutions USA, Inc. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020. Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Disclaimer Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the ACUSON Juniper System Configuration Online Training. Completion Untitled Scene Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the CC icon to display closed captioning (subtitles). Click Next to continue. Next Caption Icon add subtitles Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Layer Slide HOOD05162003144731 | Effective Date 3-Dec-2020 AVI Audio Video Interleaved CD-R Compact Disk - Recordable Clips Prospective clips capture the motion image data after clip capture is activated. Retrospective capture the motion image data in the time period just prior to activating the clip capture. The clip length is variable (one second to 60 seconds) and available in both AVI and DICOM format. Depth Gain Compensation (DGC) The 2D brightness is raised or lowered at individual zones in the field of view. DICOM Digital Imaging and Communications in Medicine. Doppler Auto Stat Enables or disables the default display of measurements and graphical traces to the track mean and/or maximum velocities or frequencies. Dual and Seamless Dual Two images displayed next to one another. Seamless dual has no center line between the two images. DVD Digital Versatile Disk Electrocardiogram ECG or EKG, this is the cardiac physiologic waveform generated from leads applied to the skin. End-Diastole (ED) and End-Systole (ES) End-diastolic and end-systolic are a period defined by the ECG / EKG signal. ED or ES are displayed as a single frame for each period. eSieImage™ Multiparametric Optimization Used to optimize the uniformity of image brightness in the field of view using eSieImage technology. The system displays the eSieImage icon on the image screen when the feature is activated. eSieScan™ Workflow Protocol An eSieScan workflow protocol is a pre-defined checklist that guides you through a clinical workflow. The protocol consists of one or more views. A protocol view is an image or clip that can also include measurements, a body marker, and annotations. When the image or clip is saved and the measurements are performed, a view is complete. Also, the user can change the sequence of views during a protocol, pause, and resume a protocol. Additionally, create new workflow protocols or modify existing protocols, import, or export protocols using a USB storage device. Freeze Still image generated by tapping the Freeze key on the control panel. Imaging parameters Displays a list of imaging settings for the active operating mode. Live Imaging This is actively using ultrasound in real-time. Mechanical and Thermal Indices The ultrasound system incorporates an output display of mechanical and thermal indices to allow you to monitor, and to limit, the amount of ultrasound energy that is transferred to the patient. The system displays the mechanical and thermal indices during real-time imaging, in all imaging modes, when the mechanical index or the thermal indices are equal to or exceed a value of 0.1. Use the Configuration settings to select the thermal indices for display during neonatal head exams. Indices display in the abbreviated form shown below:  MI: Mechanical Index  TIB: Bone Thermal Index (fetal application)  TIS: Soft Tissue Thermal Index  TIC: Cranial Thermal Index Patient Banner Displays patient information, operator, institution, the system date and time. Patient Browser The patient browser displays a list of patient studies in the selected storage location, for example, the local database (hard disk), a configured server, or a USB storage device. Patient Demographics Patients Name, Identification Number, Date of Birth, Age, Gender, Height, Weight, Body Surface Area (BSA), and Blood Pressure (BP mmHg). Physio Management This assigns the ECG or EKG lead type for use with the physiologic function. Screen Saver The screen saver feature freezes the system and replaces the active display with a screen-saver display after the system has been inactive for a specified number of minutes. Exit the active screen saver display by pressing any key, adjusting any control, or rolling the trackball. An active screen saver display also locks the screen. A locked screen requires a username and password to access the system. Note: The screen saver feature is not available when the system is in external video playback or during the Biopsy function. syngo® Arterial Health Package (AHP) (Requires the physio module option) This software is compatible with 2D-mode clips or images acquired with a linear transducer. This software provides a method of quantifying Carotid Intima-Media Thickness (CIMT). This software uses semi-automated border detection to determine the maximum and average thickness of the intima-medial layer of the carotid artery. System Configuration The location on the ultrasound system where the user can enter the utility menus. System status indicators Displays information about the ultrasound system, for example, the signal strength of a wireless network and the status of printing, video recording, and transferring data. Thumbnail panel Displays reference images of stored clips, images, and volumes. TIFF Tag Image File Format Trackball Identifies the functions currently assigned to the trackball and surrounding controls on the control panel. The trackball keys are named Set. Two-Dimensional Two-dimensional or 2D is used to define a non-volumetric ultrasound image. USB Universal Serial Bus Worklist This includes DICOM Worklist for querying and retrieving the patient worklist schedule from the hospital or radiology information system. 1.1 Welcome 1.2 System Configuration 1 1.3 System Configuration 2 1.4 System Configuration 3 1.5 Course Review 1.6 Disclaimer 1.7 Completion

  • configuration
  • customization
  • menu
  • factory defaults
  • getting started
  • start up
  • setting up
  • ultrasound
  • Juniper
  • ACUSON Juniper