ACUSON Juniper™ Ultrasound System - General System Overview - VB10 | 1.5 Software
This quick reference guide shows you the general system overview and general operation of the ACUSON Juniper ™ Ultrasound System - VB10 |1.5 Software.
ACUSON Juniper ultrasound system VB10 SW Release General System Overview Quick Reference Card siemens-healthineers.com/juniper ES SIEMENS Healthineers .. ACUSON Juniper SIEMENS Healthineers General System Overview 1. Patient Registration 2. Exam Selection 3. Review 8 9 7 10 11 4. Report 1 Patient 5. Steer 2 2D Exam 5 6 PW M 6. Angle 3 Review 14 15 16 17 7. PW Doppler 4 Steer Angle $ Depth / Focus C Report 8. Color Doppler 18 19 UD 1 Esc Dual Zoom 9. 2D Mode 12 13 20 22 10. M-mode UD 2 Body Marker Caliper Clip Store 21 11. DGC Controls Select UD 3 Pointer ** Print Store 2 12. User-defined Keys 23 13. Text, Body Marker, Arrow 14. CW Doppler 15. 3D/ 4D eSieImage Multiparametric 9MC3 16. 24 13L4 28 5CT 12L3 11L4 Add Exam 31 Optimization RD 29 30 ? Elasticity SieScape eSieScan 25 17. Depth / Focus 18. Dual 26 19. Zoom 27 20. Caliper Clear 21. Screen 33 THI Split 34 Biopsy Settings Biopsy Print Store Hide 22. Clip Store Patent Physio Settings > Trapezoid 4B CTI 32 23. Freeze Image Param Clip Settings 24. User Login / Logoff 35 End Exam 37 25. System User Manual High Density DTCE Med R/S 3 Tint 2 Image Size x Power 100% 26. System Configuration MultiHertz 3.4 MHZ Adv. SieClear 36 1 Dyn R 63 dB Map Focus Width TEQ Gain 0 27. Digital Keyboard 28. Transducers 29. Active Modes 30. Advanced Applications Tabs 31. Add Exam 32. Study Display Options 33. Blue Highlight = Active Selection 34. Gray Highlight = Available Selection 35. End Exam 36. Soft Key Rotary Control Functions 37. Page navigation 2 siemens-healthineers.com/juniper General Operation Getting Started M-mode • Press to enter patient registration page • Press to enter M-mode Patient M • Manually enter patient information or select Worklist • Use the trackball controls to change the position / size to display the modality worklist (if available) of the sample line in Anatomical M-mode • Select transducer and exam • Additional optimization selections are available on Select OK the touch screen • 2D Imaging Measurement • Press to enter B-mode imaging Press Caliper to enter measurement package • 2D • Rotate to increase / decrease gain Select the measurement label or type from the touch • screen • Additional optimization selections are available on • the touch screen Position Calipers • Press the Set key to complete the measurement Color /Power Doppler Text /Body Markers /Arrows • Press to enter Color Doppler C ABC • Press to activate text menu • Rotate to increase / decrease gain Text Body Marker CDE • Select (Color Doppler Energy) to activate Power • Select annotations from the touch screen Doppler • Select to activate digital keyboard • Use the trackball controls to change the position / size • of the Region of Interest (ROI) Select Body Marker to activate Body Markers Use Steer to steer the ROI box when using a linear O • Select Arrow to activate Arrows • transducer • Additional optimization selections are available on Image Management the touch screen • Press Print Store 1 to save an image PW Doppler • Press Clip Store save a clip Press to enter PW Doppler • Select Report to view and edit the report • PW • Rotate to increase / decrease gain • Select to view stored images / clips on active exam Review • Move the trackball to position the PW cursor • Select End Exam to end the exam • Use the soft key options to change the gate size, scale, baseline and filter Restart a Study (within 24 hours) • Rotate to adjust angle Angle • • Additional optimization selections are available on Press Patient the touch screen • Select Browser on the touch screen • Select the patient and select Restart • Select OK siemens-healthineers.com/juniper 3 For the proper use of the software or hardware, please always use At Siemens Healthineers, our purpose is to enable healthcare the Operator Manual or Instructions for Use (hereinafter collectively providers to increase value by empowering them on their journey “Operator Manual”) issued by Siemens Healthineers. This material is towards expanding precision medicine, transforming care delivery, to be used as training material only and shall by no means substitute and improving patient experience, all enabled by digitalizing the Operator Manual. Any material used in this training will not be healthcare. updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the An estimated five million patients worldwide everyday benefit from training. The Operator Manual shall be used as your main reference, our innovative technologies and services in the areas of diagnostic in particular for relevant safety information like warnings and and therapeutic imaging, laboratory diagnostics and molecular cautions. medicine as well as digital health and enterprise services. Note: Some functions shown in this material are optional and might We’re a leading medical technology company with over 120 years not be part of your system. of experience and 18,500 patents globally. With over 50,000 employees in more than 70 countries, we’ll continue to innovate Certain products, product related claims or functionalities described and shape the future of healthcare. in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Juniper and eSieImage multiparametric optimization are trademarks of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · HOOD05162003104854 · 9365 0720 · ©Siemens Medical Solutions USA, Inc., 2020
- Juniper
- ACUSON Juniper
- 4D
- foursight
- 3D
- three D
- four D
- VOI
- ROI
- MPR
- multiplanar
- volume
- reference point
- sweep angle
- volume of interest
- region of interest
- opacity
- threshold
- measurements
- 4D cine
- MultiSlice
- thick slice