ACUSON Juniper™ System Overview Course - VB10 | 1.5 Software
This web-based course is an overview of the external features, care, and cleaning of the ACUSON Juniper™ Ultrasound System.
Continue Continue HOOD05162003131894 | Effective Date 2-Dec-2020 ACUSON Juniper™ Ultrasound System Overview Online Training Welcome. This course will review the external features, user interface, transducers, and the care and cleaning of the ACUSON Juniper system (software level 1.5). These are the four learning objectives that will be covered. Review external features 1 Explain care and cleaning 4 Discuss transducers 3 Explain control panel and touch screen 2 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Welcome Base layer: welcome_overview.mp3 Welcome. In this online training course you will review the external features, user interface, transducers, and the care and cleaning of the ACUSON Juniper system software level 1.5. These are the four learning objectives that will be covered in this training. System Overview In this section you will review details about the external features of the ACUSON Juniper system. Select the numbered steps below to learn more about the external features. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 System Overview Base Layer – System Overview.mp3 In this section you will review details about the external features of the ACUSON Juniper system. Select the numbered steps below to learn more about the external features. Layer 1. Monitor: No Audio The ACUSON Juniper system showcases a 21.5 inch (54.6 cm) LED LCD monitor which features: Lower black levels Easy monitor adjustment location with posterior grips Task light with three levels of brightness Easy monitor custom setting Select each of the markers for expanded descriptions. Layer 2. Touch Screen: No Audio The customizable 13.3 inch (33.7 cm) touch screen tilts up to 20 degrees to best fit the needs of the user. Two Universal Serial Bus (USB) ports are located on the left side of the touch screen and brightness controls are located on the right. Select each of the markers for expanded descriptions. Layer 3. Gel Warmer and Transducer Holders: No Audio The standard gel warmer is configurable in location and includes adjustable temperature controls. A large gel bottle holder is also an option. The system includes six transducer holders (four are short and two support longer transducers). Holders are configurable on either side of the control panel and are easy to clean. Select the marker for an expanded description. Layer 4. Optional Peripherals: No Audio Optional Peripherals Select each of the markers for expanded descriptions about the optional peripherals. Layer 5. Optional Foot Switch: No Audio A USB enabled foot switch is available as an option and has two pedals for dual configurable functionalities. The foot switch is ideal for hands-free system operation. To configure the foot switch: Select System Configuration Custom Keys Key Function Then select from the list of custom assignments available for the Right Pedal and Left Pedal Layer 6. Storage: No Audio Storage Select each of the markers for expanded views of the generous storage capabilities on the ACUSON Juniper system. Layer 7. Wheels: No Audio Castors The ACUSON Juniper system now has easy wheeling castors with steering and lock capabilities. Select the markers for the steering and lock combinations. Layer 8. Back of System: No Audio Back of the ACUSON Juniper System Select the markers to review the components that are located on the back of the ACUSON Juniper system. Main power supply Power cord hanger Input connections Back of the ACUSON Juniper System 8 Select the markers to review the components that are located on the back of the ACUSON Juniper system. Main power supply Power cord hanger Input connections Power Cord Hanger Input Connections Main Power Supply Casters 7 The ACUSON Juniper system now has easy wheeling castors with steering and lock capabilities. Select the markers for the steering and lock combinations. Locked Position No Movement Press both pedals down to place the wheel in a locked position without movement. Unlocked Neutral Position Press both pedals up to unlock the wheel in neutral position. Steer Mode Press the green pedal down and the red pedal up to place the wheel in steer mode. Swivel Mode Press the green pedal up and the red pedal down to place the wheel in swivel mode. Select each of the markers for expanded views of the generous storage capabilities on the ACUSON Juniper system. Storage 6 Rear Basket Magnetic Side Basket Behind Touch Screen Optional Foot Switch A USB enabled foot switch is available as an option and has two pedals for dual configurable functionalities. The foot switch is ideal for hands-free system operation. To configure the foot switch: Select System Configuration Custom Keys Key Function Then select from the list of custom assignments available for the Right Pedal and Left Pedal 5 Optional Peripherals 4 Select each of the markers for expanded descriptions about the optional peripherals. Without DVD and Physio Location where the DVD and physio connections is empty. DVD and Physio configured Location where the DVD and physio connections. Without Black and White Printer Configuration without the Black and White (B & W) printer. Without Color Printer Configuration without the color printer attached. B&W Printer Configuration Shelf is configured with a B & W printer. Color Printer Configuration Configuration with the color printer attached. Gel Warmer and Transducer Holders 3 The standard gel warmer is configurable in location and includes adjustable temperature controls. A large gel bottle holder is also an option. See the marker for an expanded description. The system includes six transducer holders (four are short and two support longer transducers). Holders are configurable on either side of the control panel and are easy to clean. Gel Warmer The standard gel warmer has a configurable location to either side of the control panel and has an adjustable temperature control. The optional large gel bottle holder is shown below. The customizable 13.3 inch (33.7 cm) touch screen tilts up to 20 degrees to best fit the needs of the user. Two Universal Serial Bus (USB) ports are located on the left side of the touch screen and brightness controls are located on the right. Select each of the markers for expanded descriptions. Touch Screen 2 20° Tilting Adjustment Two USB Ports Touch Screen Brightness Control Monitor The ACUSON Juniper system showcases a 21.5 inch (54.6 cm) LED LCD monitor which features: Lower black levels Easy monitor adjustment location with posterior grips Task light with three levels of brightness Easy monitor custom setting Select each of the markers for expanded descriptions. Insert picture here 1 Task Light Three levels of brightness. Monitor Adjustments Posterior grips located at the back of the monitor. Custom Settings Custom setting adjustments. System Overview In this section you will review the additional external features of the ACUSON Juniper system. Select the numbered steps below to learn more about these external features. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 System Overview Base Layer – System Overview: .mp3 In this section you will review the additional external features of the ACUSON Juniper system. Select the numbered steps below to learn more about these external features. Layer 1. Transducer Ports: No Audio Transducer Ports Six transducer ports: Five standard transducer ports One transducer port for continuous wave (CW) or pencil transducer Layer 2. Connecting Transducers: No Audio Connecting Transducers To connect a transducer: Ensure the lever lock is in the left, unlocked position Align the connector and press into the transducer port Place the lever into the right, locked position To disconnect a transducer: Place the lever into the left, unlocked position Remove the transducer connector Layer 3. Cable Management: No Audio Cable Management With the increased number of transducer ports available on the system is important to manage the transducer cables effectively to protect the them from unintended damage. The ACUSON Juniper system showcases a flexible cable management system which includes two cable clips located above the transducer ports, as well as two cable hangers located on the control panel. Layer 4. Transducers: No Audio Transducers Offered - ACUSON Juniper System Layer 5. Articulation: No Audio Articulation The system contains articulating components which enables tilt and swivel adjustment of the control panel. Select the markers for information about articulation. Layer 6. Optional Control Panel Overlay: No Audio Optional Control Panel Overlay A disposable (optional) protective overlay is available for the system control panel. Options for the control panel overlay include a large overlay that can cover both the control panel and monitor or a set of smaller overlays to cover individual controls. Optional Control Panel Overlay A disposable (optional) protective overlay is available for the system control panel. Options for the control panel overlay include a large overlay that can cover both the control panel and monitor or a set of smaller overlays to cover individual controls. 6 Articulation The system contains articulating components which enables tilt and swivel adjustment of the control panel. Select the markers for information about articulation. Insert picture here 5 Control Panel Height Adjustment of 4.3 inches (11 cm) Control Panel Swivel 90-degrees in ether directions for a 180-degree swivel range. The 90-degree control panel swivel articulation allows the user to scan from the front or the side of the system, depending on clinical use. Monitor Articulation The monitor angel can be adjusted for optimal viewing and the monitor can swivel down for transportation. 4 Transducers Offered - ACUSON Juniper System Cable Management 3 With the increased number of transducer ports available on the system is important to manage the transducer cables effectively to protect the them from unintended damage. The ACUSON Juniper system showcases a flexible cable management system which includes two cable clips located above the transducer ports, as well as two cable hangers located on the control panel. Select the markers to review cable management. Two Cable Clips Above Transducer Ports Two Cable Clips on the Control Panel Connecting Transducers 2 To connect a transducer: Ensure the lever lock is in the left, unlocked position Align the connector and press into the transducer port Place the lever into the right, locked position To disconnect a transducer: Place the lever into the left, unlocked position Remove the transducer connector Six transducer ports: Five standard transducer ports One transducer port for continuous wave (CW) or pencil transducer Select the marker for an expanded description. Transducer Ports 1 Six Standard Ports and One CW System Overview In this section you will review details about the control panel and the touch screen on the ACUSON Juniper system. Select the numbered steps below to learn more about the control panel and touch screen. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 System Overview Baseline – System Overview: mp3 In this section you will review details about the control panel, the touch screen, on the ACUSON Juniper system. Select the numbered steps below to learn more about the control panel and touch screen. Layer 1.Power: No Audio The “Power” button is located on the control panel, to the left of the touch screen. A QuikStart standby mode is available. This feature: Powers up in less than 2 seconds and shuts down in ~4 seconds Press Power and then Standby to enter Scanning requires a power source connection The battery is located under the front of the system. Layer 2. Control Panel: No Audio Select each of the markers for the locations of controls, modes and keys. Layer 3. Keyboard: No Audio A virtual alphanumeric keyboard is located on the touch screen. There is an option for a pull-out keyboard (optional). Select the marker for an expanded description. Layer 4. Screen Saver: No Audio The system supports a screen saver feature with images of a juniper tree displayed in multiple environments over the course of a day. The system supports a screen saver feature with images of a juniper tree displayed in multiple environments over the course of a day. The screen saver offers versatility and adaptability of the system to many different scanning environments and clinical uses throughout the day. To set the timing of the screen saver: Select the System Configuration icon on the touch screen Select Display Layer 5. Image Screen: No Audio Select each of the markers to review the image screen information. Layer 6. Image Size: No Audio The system allows the user to choose the desired image size displayed on the monitor. The ACUSON Juniper ultrasound system has 5 available image sizes, which are easily selected by using the rotary soft key located at the base of the touch screen. Layer 7. Exam Touch Screen: No Audio Select each of the markers to review the touch screen controls. Next Page Icon Add Exam Preset Close Active Exam Edit Exam Preset Exam Touch Screen – Left Side 7 Select the number seven to return to the Touch Screen. Exam Touch Screen – Middle Active Transducer and Available Transducers Active Preset and Available Presets Active Page Icon 7 Select the number seven to return to the Touch Screen. Exam Touch Screen – Right Side User Log in and Log off Launch the Help Menu System Configuration Virtual Keyboard Clear Text Annotation Hide or Unhide Patient Banner Hide or Unhide Imaging Parameters End Exam 7 Select the number seven to return to the Touch Screen. Exam Touch Screen 7 Select each of the areas framed in orange to review the touch screen controls. Image Size 6 The system allows the user to choose the desired image size displayed on the monitor. The ACUSON Juniper ultrasound system has five available image sizes, which are easily selected by using the rotary soft key located at the base of the touch screen. Select each of the markers to review the image screen information. Image Screen 5 Thumbnails The thumbnail images are displayed along the right side of the image. The controls to print, delete and clear thumbnail images are located on the bottom right. Home Base or Trackball The trackball controls are mode-dependent and are displayed at the bottom of the touch screen. User-Defined (UD) Keys The assignments for the UD1, UD2, and UD3 keys are located on the control panel and the custom assignments are displayed on the bottom left of the imaging screen. These user-defined keys can be programmed in the System Configuration Menu under “Custom Keys”. Imaging Parameters The imaging parameters are displayed for each mode. The user can hide the imaging parameters by selecting Imaging Parameters on the left side of the touch screen. Select Imaging Parameters again to restore. Patient Banner The Patient Banner displays the patient information. The Hospital name can be entered in the System Configuration menu under “General 1”. Screen Saver The system supports a screen saver feature with images of a juniper tree displayed in multiple environments over the course of a day. The screen saver offers versatility and adaptability of the system to many different scanning environments and clinical uses throughout the day. To set the timing of the screen saver: Select the System Configuration icon on the touch screen Select Display 4 Keyboard 3 A virtual alphanumeric keyboard is located on the touch screen. There is an option for a pull-out keyboard (optional). Select the marker for an expanded description. Language and Special Character Key The language key is located on the digital keyboard (shown framed in orange) and gives the user access to special characters as desired. Select each of the markers for the locations of controls, modes and keys. Control Panel 2 Workflow Controls Doppler Controls Doppler steer and Doppler Angle controls. Three User-Defined (UD) Controls Text & Body Marker Pointer Major Modes: Pulse Wave (PW) Doppler Continuous Wave (CW) Doppler Color Doppler Velocity (C) Two-dimensional (2D) M-Mode (M) Soft Keys DCG Controls eSieImage Print and Clip Store Caliper Freeze Key Set Set Update Dual and Zoom Depth and Focus Power The “Power” button is located on the control panel, to the left of the touch screen. A QuickStart standby mode is available. This feature: Powers up in less than 2 seconds and shuts down in ~4 seconds Press Power and then Standby to enter Scanning requires a power source connection The battery is located under the front of the system. Insert picture here 1 Care and Cleaning In this final section, a high-level review of the care and cleaning of the ACUSON Juniper system will be described. Please select the tab arrows to learn more about care and cleaning. System Filter Cleaning the System Cleaning the Trackball Clean and Care Baseline – Clean and Care: 1.5.mp3 In this final section, a high-level review of the care and cleaning of the ACUSON Juniper system will be described. Please select the tab arrows to learn more about care and cleaning. Tab 1, Filter: No Audio System Filter The filter is located on the back of the system. To clean the filter: Power off the ultrasound system and unplug the power cord from the power supply. Push the air filter tray in to release the locking mechanism and then pull the tray from the system. Rinse the air filter tray with running water and allow the filter to completely dry. Check and clean the air filters weekly, or as needed, to maintain proper system cooling. For more information on cleaning procedures and approved agents that are approved for use on this transducer please consult the Siemens Healthineers cleaning and disinfectant website: https://www.siemens-healthineers.com/en-us/ultrasound/ultrasound-transducer-catalog Tab 2. System: No Audio Cleaning the System Power off system and unplug the power cord from the power supply. Use clean gauze pad or lint-free cloth, lightly moistened with a mild detergent to gently wipe: Touch screen Monitor Control Panel Dry surfaces with a clean lint-free cloth As required use an approved disinfectant wipe to disinfect the system and accessories https://www.siemens-healthineers.com/en-us/ultrasound/ultrasound-transducer-catalog Tab 3. Trackball: No Audio Cleaning the Trackball 1. Rotate the ring around the trackball counterclockwise and carefully lift the ring to remove. 2. Remove the trackball. 3. Clean the ring, trackball and trackball assembly with a cotton swab or lint-free pad moistened with a mild detergent solution (as required, use an approved disinfectant wipe to disinfect the ring, trackball and trackball assembly). 4. After allowing the trackball components to completely dry, place the trackball into the assembly. 5. Place the ring over the trackball, aligning the tab with the point of attachment on the assembly, and rotate clockwise until the ring snaps into place. Cleaning the Trackball Rotate the ring around the trackball counterclockwise and carefully lift the ring to remove. Remove the trackball. Clean the ring, trackball and trackball assembly with a cotton swab or lint-free pad moistened with a mild detergent solution (as required, use an approved disinfectant wipe to disinfect the ring, trackball and trackball assembly). After allowing the trackball components to completely dry, place the trackball into the assembly. Place the ring over the trackball, aligning the tab with the point of attachment on the assembly, and rotate clockwise until the ring snaps into place. Power off system and unplug the power cord from the power supply. Use clean gauze pad or lint-free cloth, lightly moistened with a mild detergent to gently wipe: Touch screen Monitor Control Panel Dry surfaces with a clean lint-free cloth As required use an approved disinfectant wipe to disinfect the system and accessories https://www.siemens-healthineers.com/en-us/ultrasound/ultrasound-transducer-catalog Cleaning the System The filter is located on the back of the system. To clean the filter: Power off the ultrasound system and unplug the power cord from the power supply Push the air filter tray in to release the locking mechanism and then pull the tray from the system Rinse the air filter tray with running water and allow the filter to completely dry Check and clean the air filters weekly, or as needed, to maintain proper system cooling. System Filter Explain care and cleaning Discuss transducers Explain control panel and touch screen Review external features Course Review Congratulations. You have completed the ACUSON Juniper™ Ultrasound System Overview, online training. Select the objectives below to review the material. 1 1 1 2 3 3 3 4 4 4 Course Review Explain Care and Cleaning The trackball and system filter can be removed and cleaned External system can be cleaned There is an optional control panel overlay A large overlay that can cover both the control panel and monitor or a set of smaller overlays to cover individual controls For more information on cleaning procedures and approved agents that are approved for use on the system and the transducers please consult the Siemens Healthineers cleaning and disinfectant website: https://www.siemens-healthineers.com/en-us/ultrasound/ultrasound-transducer-catalog Discuss Transducers Explain Control Panel and Touch Screen The power is located on the upper left of the control panel Patient management, exam, image review, and reporting are located on the control panel below the power The soft keys are located at the top of the control panel The trackball and keys that enable the major modes are located on the control panel The control panel also has keys and controls for image freeze, clip store, print, calipers, eSieImage optimization, overall gain, DCG, depth, zoom, dual imaging, text, pointer, body marker, Doppler angle, and Doppler steer The control panel has three user defined keys The touch screen is located above the control panel and the soft keys on the control panel interface with the touch screen The touch screen accesses the alphanumeric keyboard Optional pull-out keyboard (beneath the control panel) The touch screen is customizable Review External Features The LED LCD Monitor features lower black levels, easy adjustments, and a task light Customizable touch screen can tilt for optimal viewing angles The location of the gel warmer is configurable with adjustable temperature control An optional foot switch can be configured to operate basic system operation Easy wheeling castors have steering and lock capabilities The screen saver feature displays images of a juniper tree displayed in multiple environments over the course of a day Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. ACUSON Juniper is a trademark of Siemens Healthineers. eSieImage optimization is a trademark of Siemens Healthcare GmbH. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020. Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Disclaimer Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the ACUSON Juniper System Overview Online Training. Completion HOOD05162003131894 | Effective Date 2-Dec-2020 1.1 Welcome 1.2 System Overview 1.6 Course Review 1.7 Disclaimer 1.8 Completion
- Care
- Cleaning
- Control Panel
- Touch Screen
- Patient Banner
- Getting Started
- Ultrasound
- Transducers
- Juniper
- Workflow ACUSON
- ACUSON Juniper