ACUSON Juniper™ Ultrasound System Transducers VB10 | 1.5 Software

Explore all of the transducers that can be used with the ACUSON Juniper VB10 | 1.5 Software.

Transducers ACUSON Juniper ultrasound system siemens-healthineers.com/juniper HOOD05162003102719 - June 26, 2020 - -- SIEMENS . Healthineers ... ACUSON Juniper OJ SIEMENS Healthineers Transducer overview · ACUSON Juniper ACUSON Juniper Image every patient Contents Curved 3 Linear 6 Micro Convex 9 Phased Array 9 Vector 10 Pencil 12 2 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview Curved 5C1 Transducer Form factor Curved Design 1D, Hanafy, Piezoceramic Gesture detection No SC1 Bandwidth 1.4–5.0 MHz Axial and Lateral resolution 2.0 mm x 2.0 mm Maximum depth 300 mm Field of view 70 deg Physical footprint 22.8 x 70.6 mm Total weight 488 g 7C2 Transducer Form factor Curved Design 1D, Hanafy, Piezoceramic Gesture detection No 7C2 Bandwidth 2.1–7.0 MHz Axial and Lateral resolution 2.0 mm and 2.0 mm Maximum depth 300 mm Field of view 70 deg Physical footprint 22.9 x 70.6 mm Total weight 548 g siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 3 Transducer overview · ACUSON Juniper 8VC3 Transducer Form factor Curved E018 Design 1D, Piezoceramic Gesture detection No Bandwidth 2.6–8.0 MHz Axial and Lateral resolution 2.0 mm and 2.0 mm Maximum depth 300 mm Field of view 69 deg Physical footprint 55 x 74 mm Total weight 757 g 9MC3 Transducer SMCS Form factor Curved Design 1D, Piezoceramic Gesture detection No Bandwidth 3.2–8.5 MHz Axial and Lateral resolution 1.0 mm and 2.0 mm Maximum depth 140 mm Field of view 220 deg Physical footprint 17 x 22 mm Total weight 490 g 4 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview 9VE3 Transducer Form factor Curved Design 1D, Piezoceramic Gesture detection No Bandwidth 3.0–9.0 MHz Axial and Lateral resolution 1.0 mm and 1.0 mm Maximum depth 140 mm Field of view 145 deg Physical footprint – Total weight 650 g 10MC3 Transducer Form factor Curved Design 1D, Piezoceramic Gesture detection No Bandwidth 3.5–10.2 MHz Axial and Lateral resolution – Maximum depth 140 mm Field of view 150 deg Physical footprint 19 x 22.2 mm Total weight 510 g siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 5 Transducer overview · ACUSON Juniper Linear 11L4 Transducer Form factor Linear Design Piezoceramic Gesture detection No 11L4 Bandwidth 3.6–12.9 MHz Axial and Lateral resolution 0.5 mm and 0.5 mm Maximum depth 160 mm Field of view 120 mm Physical footprint 18.8 x 50.6 mm Total weight 398 g 12L3 Transducer Form factor Linear Design 1D, Hanafy, Piezoceramic Gesture detection No 12L3 Bandwidth 2.6–11.5 MHz Axial and Lateral resolution 0.5 mm and 1.0 mm Maximum depth 160 mm Field of view 133 mm Physical footprint 14.6 x 61.9 mm Total weight 483 g 6 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview 13L4 Transducer Form factor Linear ACUSON Design 1D, Piezoceramic Gesture detection No 13 4 Bandwidth 3.9–12.6 MHz Axial and Lateral resolution 0.5 mm and 2.0 mm Maximum depth 160 mm Field of view 150 mm Physical footprint 47.5 mm x 12.7 mm Total weight 445 g 16L4 Transducer Form factor Linear Design 1D, Piezoceramic Gesture detection No Bandwidth 4.3–15.4 MHz 16L4 Axial and Lateral resolution 0.5 mm and 1.0 mm Maximum depth 60 mm Field of view 65 mm Physical footprint 12.1 x 43.3 mm Total weight 401 g siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 7 Transducer overview · ACUSON Juniper Linear 18H5 Transducer Form factor Linear Design 1D, Piezoceramic 18H5 Gesture detection No Bandwidth 4.5–18.0 MHz Axial and Lateral resolution 0.5 mm and 0.5 mm Maximum depth 80 mm Field of view 68 mm Physical footprint 10.2 x 35.8 mm Total weight 450 g 8 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview Micro-Convex 11M3 Transducer Form factor Micro-convex Design 1D, Piezoceramic Gesture detection No Bandwidth 3.5–11.0 MHz 11M3 Axial and Lateral resolution 2.0 mm and 2.0 mm Maximum depth 140 mm Field of view 110 deg Physical footprint 12.8 x 29 mm Total weight 340 g Phased Array 5P1 Transducer Form factor Phased Design 1D, Single Crystal Gesture detection No 5P1 Bandwidth 1.1–5.0 MHz Axial and Lateral resolution 2.0 mm and 1.0 mm Maximum depth 300 mm Field of view 90 deg Physical footprint 17.5 x 27.8 mm Total weight 380 g siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 9 Transducer overview · ACUSON Juniper Vector 5VT Transducer Form factor Vector Design Vector Gesture detection No Bandwidth 3.1–9.2 MHz Axial and Lateral resolution 1.0 mm and 1.0 mm Maximum depth 240 mm Field of view 90 deg Physical footprint 14.8 x 11.6 mm Total weight 1800 g 8V4 Transducer Form factor Vector Design 1D, Piezoceramic Gesture detection No Bandwidth 2.7–8.0 MHz 8V4 Axial and Lateral resolution 2.0 mm and 2.0 mm Maximum depth 140 mm Field of view 90 deg Physical footprint 14.1 x 15.2 mm Total weight 402 g 10 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview 10V4 Transducer Form factor Vector Design 1D, Piezoceramic Gesture detection No Bandwidth 3.4–10.4 MHz OV" Axial and Lateral resolution 1.0 mm and 1.0 mm Maximum depth 140 mm Field of view 90 deg Physical footprint 14.3 x 22.6 mm Total weight 376 g siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 11 Transducer overview · ACUSON Juniper Pencil CW2 Transducer Form factor Pencil Design 1D, Piezoceramic Gesture detection No Bandwidth N/A Axial and Lateral resolution N/A Maximum depth N/A Field of view N/A Physical footprint 17.1 mm Total weight 181 g CW5 Transducer Form factor Pencil Design 1D, Piezoceramic Gesture detection No Bandwidth N/A Axial and Lateral resolution N/A Maximum depth N/A Field of view N/A Physical footprint 12.0 mm Total weight 190 g 12 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview CW8 Transducer Form factor Pencil Design 1D, Piezoceramic Gesture detection No Bandwidth N/A Axial and Lateral resolution N/A Maximum depth N/A Field of view N/A Physical footprint 8.2 mm Total weight 67 g siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 13 Transducer overview · ACUSON Juniper Table 1: Selectable frequencies Transducer Fundamental Harmonic Color Doppler PW Doppler CW DTI 5C1 • 2.5 • 3.1 • 2.0 • 2.0 – – • 3.1 • 3.4 • 2.7 • 2.7 • 4.0 • 3.6 • 4.4 • 5.0 7C2 • 3.6 • 4.4 • 2.7 • 2.7 – – • 4.4 • 5.0 • 3.3 • 3.3 • 5.0 • 5.7 • 5.7 8VC3 • 3.3 • 4.4 • 2.7 • 2.7 – – • 4.2 • 5.0 • 3.3 • 3.3 • 5.0 • 5.7 • 6.2 (PVF) 9MC3 • 4.2 • 5.0 • 4.0 • 4.0 – – • 5.7 • 5.7 • 5.3 • 5.3 • 7.3 • 7.3 9VE3 • 4.7 • 5.7 • 4.0 • 4.0 – – • 5.7 • 6.6 • 5.3 • 5.3 • 7.3 • 7.3 10MC3 • 5.0 • 6.6 • 4.0 • 4.0 – – • 6.2 • 7.2 • 5.3 • 5.3 • 7.3 • 9.4 • 6.2 • 6.2 11L4 • 6.2 • 7.3 • 4.0 • 4.0 – – • 8.0 • 8.0 • 5.3 • 5.3 • 10.0 • 9.4 • 6.2 • 6.2 12L3 • 6.2 • 6.7 • 4.0 • 4.0 – – • 8.0 • 8.4 • 6.7 • 6.7 • 13.3 • 10.0 13L4 – – – – – – 16L4 • 8.0 • 9.4 • 5.3 • 5.3 – – • 10.0 • 10.7 • 6.2 • 6.2 • 13.3 • 12.3 18H5 • 8.0 • 10.6 • 6.2 • 6.2 – – • 11.4 • 12.3 • 7.3 • 7.3 • 13.3 • 14.5 11M3 • 4.0 • 6.2 • 3.6 • 3.6 • 3.6 – • 4.3 • 7.3 • 4.4 • 4.4 • 4.4 • 5.7 • 8.0 • 8.0 14 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview Transducer Fundamental Harmonic Color Doppler PW Doppler CW DTI 5P1 • 1.6 (TCD) • 2.7 • 1.8 • 1.8 • 1.8 • 1.8 • 2 (TCD) • 3.0 • 2.2 • 2.2 • 2.2 • 2.5 • 3.7 • 2.5 • 2.5 • 2.5 • 3.1 • 4.0 • 3.6 5VT – – – – – – 8V4 • 4.2 • 5.4 • 3.6 • 3.6 • 3.6 • 4.2 • 5.7 • 6.2 • 4.4 • 4.4 • 5.7 • 6.7 • 7.2 • 6.7 10V4 • 4.0 • 6.6 • 4.0 • 4.0 • 4.0 • 4.0 • 5.3 • 7.2 • 5.0 • 5.0 • 4.4 • 5.3 • 7.2 • 8.0 • 6.2 • 6.2 • 8.9 • 8.8 CW2 • 2 – – – – – CW5 • 5 – – – – – CW8 – – – – – – Table 2: Cable length Transducer Cable length Transducer Cable length 5C1 1.95 m 11M3 2.1 m 7C2 1.95 m 5P1 2.1 m 8VC3 2.1 m 5VT 1.9 m 9MC3 2.2 m 8V4 2.2 m 9VE3 2.1 m 10V4 2.2 m 10MC3 2.13 m CW2 1.9 m 11L4 2.23 m CW5 2.1 m 12L3 2.1 m CW8 2.1 m 13L4 2.1 m 16L4 2.1 m 18H5 2.2 m siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 15 Transducer overview · ACUSON Juniper Table 3: Table 4: Connector type Needle guide Transducer Connector Transducer Product Guidance angle type description selection – depth 5C1 TC-ZIF 5C1 Ultra-Pro II 4, 8 cm 7C2 TC-ZIF 7C2 Ultra-Pro II 10 cm 8VC3 TC-ZIF 8VC3 N/A – 9MC3 TC-ZIF 9MC3 Endocavity NG 15.7 cm (Disposable), 16 cm (Reusable) 9VE3 TC-ZIF – 10MC3 TC-ZIF 9VE3 N/A 11L4 TC-ZIF 10MC3 Endocavity NG 0 angle 12L3 TC-ZIF 11L4 Ultra-Pro II 2.4, 4 cm 13L4 TC-ZIF 12L3 Ultra-Pro II 3 cm – 16L4 TC-ZIF 13L4 Available 18H5 TC-ZIF 16L4 Infinih Free angle – 11M3 TC-ZIF 18H5 N/A – 5P1 TC-ZIF 11M3 N/A 5VT TC-ZIF 5P1 N/A – 8V4 Hirose 5VT N/A N/A – 10V4 Hirose 8V4 N/A CW2 TC-ZIF 10V4 N/A – CW5 TC-ZIF CW2 N/A – CW8 Hirose CW5 N/A – CW8 N/A N/A 16 siemens-healthineers.com/juniper - HOOD05162003102719 - June 26, 2020 ACUSON Juniper · Transducer overview Table 5: Advanced applications Transducer Strain Point Shear Wave 2D Shear Wave Contrast Fusion Elastography Elastography Elastography Imaging Imaging 5C1 N/A Yes N/A N/A N/A 7C2 N/A N/A N/A N/A N/A 8VC3 N/A N/A N/A N/A N/A 9MC3 N/A N/A N/A N/A N/A 9VE3 N/A N/A N/A N/A N/A 10MC3 N/A N/A N/A N/A N/A 11L4 Yes N/A N/A N/A N/A 12L3 Yes N/A N/A N/A N/A 13L4 Available N/A N/A N/A N/A 16L4 Yes N/A N/A N/A N/A 18H5 Yes N/A N/A N/A N/A 11M3 N/A N/A N/A N/A N/A 5P1 N/A N/A N/A N/A N/A 5VT N/A N/A N/A N/A N/A 8V4 N/A N/A N/A N/A N/A 10V4 N/A N/A N/A N/A N/A CW2 N/A N/A N/A N/A N/A CW5 N/A N/A N/A N/A N/A CW8 N/A N/A N/A N/A N/A siemens-healthineers.com/juniper- HOOD05162003102719 - June 26, 2020 17 The products/features mentioned in this document may At Siemens Healthineers, our purpose is to enable not be commercially available in all countries. Due to healthcare providers to increase value by empowering regulatory reasons, their future availability cannot be them on their journey towards expanding precision guaranteed. medicine, transforming care delivery, and improving patient experience, all enabled by digitalizing healthcare. Please contact your local Siemens Healthineers organization for further details. An estimated five million patients worldwide everyday benefit from our innovative technologies and services ACUSON Juniper and MultiHertz are trademarks of in the areas of diagnostic and therapeutic imaging, Siemens Medical Solutions USA, Inc. laboratory diagnostics and molecular medicine as well as digital health and enterprise services. We’re a leading medical technology company with over 120 years of experience and 18,500 patents globally. With over 50,000 employees in more than 70 countries, we’ll continue to innovate and shape the future of healthcare. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, siemens-healthineers.com USA Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · 9319 0620 online · HOOD05162003102719 - June 26, 2020 - © Siemens Medical Solutions USA, Inc., 2020

  • Juniper
  • ACUSON Juniper
  • stress
  • echo
  • view control
  • continuous capture
  • adult
  • echocardiography
  • adult echo
  • pediatric echo