This quick reference guide provides an overview of the system, starting an exam, major modes, measurements and calculations, text arrow and pictograms plus data and image management for the ACUSON NX2™ Ultrasound System.

M Clip store Print store 1 ACUSON NX2TM Series Ultrasound Systems Quick Reference Guide SIEMENS siemens.com/ultrasound Healthineers HOOD05162002850609 20180913 2 Table of content System Overview 3 Getting Started 10 2D Mode and M-mode 14 Color and Spectral Doppler 26 Measurements and Calculations 38 Text, Arrow and Pictograms 48 Data and Image Management 54 HOOD05162002850609 20180913 L4g System Overview 3 Control Panel 1. Patient Workflow Controls 2. User-defined Keys 4 10 3. Toggle Key Controls Ctrl END 4. Alphanumeric Keyboard 3 New Patient 5. Text and Pictograms 1 Exam 6 Applications 6. Major Modes Z 11 Review 2 20 D M 7. Angle, Steer and Invert Report Angle 7 Depth / Zoom Focus 2 CW Power 3D/4D 9 UD 3 TGO 12 8. Select Key Update / View UD 4 5 Invert Steer HD Zoom Dual UD 1 / UD2 9. TGO Image Optimization T Text Pictogram Set Set Print Store 2 Clip Store 10. DCG Controls 2 13 11. Depth, Zoom ,Focus UD 5 +* Select Print Store 1 12. HD Zoom and Dual 8 14 ESC x ... x Caliper 13. Print, Store and Clip 15 14. Freeze 15. Home Base Controls HOOD05162002850609 20180913 System Overview System Overview 4 Control Panel – Power On / Off 1. Press 3. When in Standby Mode, the Power Key 2. Select from the Dialog box to Shut Down or will be Orange. enter QuikStart Standby Mode (option) 4. Press to exit QuikStart Standby Mode and resume scanning. Shut down System What do you want the system to do? Shut down Standby Restart Cancel HOOD05162002850609 20180913 L4g 5 Home Base Area 1. Left Set 2. Right Set 3. Update / View 3 4. Escape et Se 5. Caliper 6. Trackball (CINE review) 1 2 7. Wrist Support 6 x ... x 4 5 7 HOOD05162002850609 20180913 System Overview System Overview 6 Status Icon 1. Select Key 2. Update Key SIEMENS SIEMENS ACUSON NX2 3. Trackball CH5-2 Thumbnails Patientinfo Results Renal 22.6 -4 dB 2.7 MHZ 4. Escape Key 1563 Hz Filter 1 RIS Map A 5. Caps Lock Priority 4 Smooth 2 Flow M 4 fps 6. Wireless Connection SC 2 DTCE Med 7. Insert / Overwrite 13 Cm P 100% MI 1.14 TIS 0.7 TIB 0.7 Images 5 Edit Start Edit End Edit Reset Rate humbnail × 2D C (*) Thumbnail Cine INS 1 2 3 4 5 6 7 Thumbnail Cine A INS HOOD05162002850609 20180913 7 Connecting Transducer SNBINBIS SNBY -.... .................... L22809012895* A IPX8 3 A IPX8 1 CH5-2 CH5-2 In the unlocked position, insert the transducer Turn the lock clockwise until it locks into place. into the port located on the front of the system. HOOD05162002850609 20180913 System Overview System Overview 8 Wheel Locks PREE BLOCKE Unlocked (wheels can swivel and roll). Locked (wheels cannot swivel and roll). HOOD05162002850609 20180913 9 HOOD05162002850609 20180913 System Overview Getting Started 10 Patient Registration New Patient New Patient 1. Press 3. Select the Transducer and 2. Enter patient information. Exam type and select OK. Patient Exam Transducer CH5-2 Last Name First Name Exam Abdomen MI Pre Suf. Patient ID Date of Birth DD/MM/YYYY Sex . Male . Female . Unknown Age Height [cm] Weight [kg] BSA (m2) BP [mmHg] HOOD05162002850609 20180913 L4g 11 Edit Study Patient Registration – Worklist New Patient 1. Press 1. Press 2. Use the keyboard to edit patient 2. Enter patient information to search information. 3. Select Worklist at the upper left side 3. Select OK to save. of the form Select US (Ultrasound) Search - Select the study and press Select - Select OK to begin - the study ! System must be connected to a HIS / RIS server to access patient worklist. HOOD05162002850609 20180913 Getting Started Getting Started 12 Transducer / Study Control Panel 3. To change transducers during an Quick Set Exam Select hard key. exam, press Exam or the user-defined 1. or key assigned to the transducer. 2. Select a transducer from the upper UD5 right menu on the image screen. Transducer L10-5v P4-2 HOOD05162002850609 20180913 L4g Process Studies, Store, Print, Review and End Exam 13 Review Clip Store Print Store 1 Print Store 2 Select Review 1. Press to acquire and save the clip. 4. Press then , Clip Store Press to view 1x1 format - 2. Press to freeze the clip / image Select frame. Freeze Rotate to move between images. - 3. If desired, roll trackball for Select frame-by-frame CINE review. 5. Press END on the keyboard to end Press to save a static image. the study. - Print Store 1 A compatible printer must be Press to save and print. ! - connected and assigned to the print Print Store 2 function in the Presets menu before TIP Starting a new patient also the print function becomes active. ends a current exam. Print Store 1 and 2 are customized in the Presets menu. HOOD05162002850609 20180913 Getting Started 2D Mode and M-mode 14 2D Control Panel Control Panel Controls Function Brightness Mode 2D Press to enter / exit 2D mode. Rotate to adjust overall 2D gain / brightness. TGO One-button image optimization (TGO Tissue Grayscale Press to optimize the overall image displayed. Optimization Technology) Press twice to deactivate. Note: Available on live image only. Manually adjusts gain / brightness at depth DGC Default all slide controls in the center. Note: Available on live image only. Adjusts the focal zone Focus Rotate to move up / down and press to activate multiple focal zones. Note: Only available with certain transducers. HOOD05162002850609 20180913 L4g 15 Adjusts the scanning depth and magnifies the image Rotate clockwise / counter-clockwise to increase / decrease depth. Depth / Zoom Press to activate zoom. Rotate to change region of interest (ROI) size and press to activate. Press again to exit zoom. Note: Zoom available in live or frozen images. Displays a high density zoom HD Zoom Press to activate. Rotate the Depth / Zoom to increase / decrease ROI. Press Depth / Zoom or HD Zoom to activate. Displays two separately acquired images side-by-side Dual Press Dual to activate and toggle between images. Press the 2D key to exit. Displays four separately acquired images 4B Select to activate and add each image. Assign to a user-defined key to access. Note: Available on live image only in 2D and Color Doppler. HOOD05162002850609 20180913 2D Mode and M-mode 2D Mode and M-mode 16 2D Image Screen Toggle Key Function Controls the TGO gain offset TGO Gain Select to adjust up / down. Note: TGO must be active to adjust. Displays linear or trapezoid image format. Trapezoid Select to activate / deactivate. Note: Available on live image only. Available on linear transducers only. Defaults to SieClear 2 upon activation. THI (Tissue Harmonic Increases contrast and lateral resolution. Reduces noise and clutter. Imaging) Select to activate / deactivate. Note: Available on live image only. SieClear (SieClear Multi- Enhances contrast resolution and boundary detection view Spatial Compounding) Increase for more compounding. Decrease for less compounding. and AdvSieClear (Advanced Note: Available on live image only. Settings are transducer and SieClear Spatial mode dependent. Compounding) HOOD05162002850609 20180913 L4g 17 Sharpens the contours of a structure Increase for more sharpness. Edge Decrease for less sharpness. To deactivate, select zero. Note: Available on live image only. Balances line density (spatial resolution) and frame rate RS (Resolution / Speed) Increase to improve image detail. Decrease to improve frame rate. Note: Available on live image only. DTCE (Dynamic TCE Tissue Reduces speckle and enhances tissue contrast Contrast Enhancement Settings are Low, Medium and High. Technology) Note: Available on live or frozen images. HOOD05162002850609 20180913 2D Mode and M-mode 2D Mode and M-mode 18 2D Image Screen Toggle Key Controls Function Split Activates two simultaneous images in dual format Select to activate / deactivate. DTO (DTO Dynamic Tissue Activates level of gain compensations. Reduces bright whites. Optimization Technology) Increase to reduce whites. ClarifyVE Decreases artifacts, increases contrast resolution and boundary (Clarify Vascular detection in structures with flow. Enhancement (VE) Select to activate / deactivate. Technology) Note: Available on live imaging only. Adjusts levels of sensitivity when using ClarifyVE ClarifyVE Levels Select a higher level to increase sensitivity. Select a lower level to decrease sensitivity. Note: Available on live imaging only. HOOD05162002850609 20180913 L4g 19 Frame averaging – determines the number of frames combined into the final image Persist (Persistence) Increase for frame averaging. Decrease to demonstrate motion. To deactivate, select zero. Note: Available only on live image when SieClear is set to 2 or Off. Adjusts orientation on image screen U/D Flip (Up / Down flip) Select to switch between orientations R/L Flip (Right / Left flip) [up(U) or down(D) and right(R) or left(L)]. Note: Available on live or frozen image. Selects type of clip capture Chronology: Prospective, Retrospective. Clip Capture >> Acquisition Rate: Normal, High. Trigger Type: Time Capture, Beat Capture, Rwave Capture. Note: Available on live image only. HOOD05162002850609 20180913 2D Mode and M-mode 2D Mode and M-mode 20 2D Image Screen Toggle Key Controls Function Adjusts acoustic energy delivered to the patient Select a higher level to increase power. P (Transmit Power) Select a lower level to decrease power. Note: Available on live image only. Changes Mechanical (MI) and Thermal (TIS, TIB) Indices. Adjusts number of gray shades displayed DR (Dynamic Range) Increase for a softer / grayer image. Decrease to increase contrast. Note: Available on live or frozen images. MultiHertz Balances between resolution and penetration (MultiHertz Multiple Use higher frequency to increase resolution. Frequency Imaging) Use lower frequency to increase penetration. Note: Available on live image only. HOOD05162002850609 20180913 L4g 21 Processing curves that assign echo amplitudes to gray shades Map Maps A – I are from low to high contrast. Maps 1– 3 are customizable maps (Modify Map). Note: Available on live or frozen images. Colorizes the grayscale image Tint Select for tints from 0 –15. Note: Available on live or frozen images. Adjusts image orientation in 90 degree increments Rotate Select to adjust Note: Available on live image only. HOOD05162002850609 20180913 2D Mode and M-mode 2D Mode and M-mode 22 M-mode Control Panel Control Panel Controls Function Enters / exits M-mode and adjusts overall M-mode gain Press to activate / deactivate. M (M-mode) Roll the trackball to position the M-mode cursor. Rotate to adjust overall M-mode gain. Note: Available on live image only. Alternates between 2D / M-mode formats on the Image Screen Update / View Press to move between modes. Note: Available on live images only. Enters / exits color M-mode With Color Doppler activated, press M (M-mode). Color M-mode Place cursor and Press M. Press M to exit. Note: Only available with cardiac transducers. HOOD05162002850609 20180913 L4g 23 M-mode Image Screen Toggle Key Controls Function Changes the display format to full M-Mode Full M Select to activate / deactivate. Note: Available on live or frozen image. Adjusts the scrolling speed of the M-mode sweep Sweep Speed Increase to display less cardiac cycles. Decrease to display more cardiac cycles. Note: Available on live or frozen image. Sharpens the contours of a structure in the M-mode sweep Increase for more sharpness. Edge Decrease for less sharpness. To deactivate, select 0. Note: Available on live image only. HOOD05162002850609 20180913 2D Mode and M-mode 2D Mode and M-mode 24 M-mode Image Screen Toggle Key Controls Function Adjusts Frequency for 2D image and M-mode strip MultiHertz (frequency) Select a higher level to increase resolution. Select a lower level to increase penetration. Note: Available on live image only. Processing curves that assign echo amplitudes to gray shades Maps in the M-mode sweep Map choice is displayed from low to high contrast. Note: Available on live or frozen image. Colorizes the M-mode sweep Tint Select tints from 0 –15. Note: Available on live or frozen image. Adjusts number of gray shades displayed in the M-mode sweep DR (Dynamic Range) Increase for a softer / grayer sweep. Decrease for increased contrast. Note: Available on live or frozen image. HOOD05162002850609 20180913 L4g 25 HOOD05162002850609 20180913 2D Mode and M-mode Color and Spectral Doppler 26 Color Doppler Control Panel Control Panel Controls Function Enters / exits color Doppler or adjusts overall color Doppler gain C (Color Doppler) Press to activate / deactivate color Doppler mode. Rotate to increase / decrease color Doppler gain. Note: Available on live image only. Applies colors based on flow amplitude Power (Power Doppler) Select Power to activate / deactivate. Rotate Color key to increase / decrease Power Doppler gain. Note: Available on live image only. Adjusts the color ROI Increase frame rate by decreasing the color ROI width or depth. Color Box Size / Position Press Set to alternate between Size / Position. Roll the trackball to resize or reposition color ROI. Note: Available on live image only. Steers the Color ROI Steer Toggle the Steer key left / right to steer. Note: Steering Angle is transducer dependent. Available only on linear transducers. HOOD05162002850609 20180913 27 Reverses the colors depicting forward and reverses flow Invert in the color ROI and the color bar Select to activate / deactivate. Note: Available on live or frozen images. Color Doppler Image Screen Toggle Key Controls Function Flow state optimization presets Flow Choices are Low, Medium, High. Select desired preset to optimize flow state. Note: Available on live image only. Balances line density (spatial resolution) and frame rate RS (Resolution / Speed) Increase for image detail. Decrease to increase frame rate. Note: Available on live image only. HOOD05162002850609 20180913 Color and Spectral Doppler Color and Spectral Doppler 28 Color Doppler Image Screen Toggle Key Controls Function Adjusts spatial averaging (smoothing) for color flow Smooth Increase for flow sensitivity. Decrease for color spatial resolution. Note: Available on live image only. Adjusts the time that the color flow data remains in the ROI before being replaced by another color Persistence Increase for greater vessel color fill. Decrease to increase temporal resolution. Note: Available on live image only. Adjusts the color wall filter Filter Increase to reduce motion artifacts. Decrease to increase sensitivity to low flow states. Note: Available on live image only. HOOD05162002850609 20180913 L4g 29 Prioritizes the display of grayscale or color flow data Priority Increase for greater vessel color fill. Decrease to prioritize grayscale and less vessel color fill. Note: Available on live image only. Turns color display off image when in Color Doppler Display Select to activate / deactivate. Note: Color ROI remains on image. Adjusts the color Doppler frequency independent of the 2D frequency MultiHertz (frequency) Select a higher level to increase resolution. Select a lower level to increase penetration. Note: Available on live image only. Selects a processing curve that assigns the velocity / velocity variance Maps (for Color) or flow amplitudes (for Power) to a range of colors Maps choices are A – I. Note: Available on live or frozen image. Acoustic energy delivered to the patient in color Doppler mode P (Transmit Power) Increase / decrease to adjust the transmit power. Note: Available on live image only. Changes Mechanical and Thermal Indices displayed. HOOD05162002850609 20180913 Color and Spectral Doppler Color and Spectral Doppler 30 Color Doppler Image Screen Toggle Key Controls Function Adjusts the pulse repetition frequency (PRF) Scale Increase / decrease to adjust the PRF. Note: Available on live image only. Adjusts the range of flow velocities displayed above Baseline and below the baseline Move up / down to adjust the baseline of the active mode. Note: Available on live image only. DTI (DTI Doppler Tissue Activates the Doppler Tissue Imaging feature for cardiac exams Imaging Capability) Press to activate / deactivate. Note: Available on live image only. Available on ACUSON NX2 Elite only. HOOD05162002850609 20180913 L4g 31 Spectral Doppler Control Panel Control Panel Controls Function Enters / exits spectral Doppler or adjusts overall spectral Doppler gain D (pulsed wave) Doppler Press to activate / deactivate. and CW (continuous Roll trackball to position Doppler gate. wave) Doppler Press D or CW to activate the strip. Rotate to adjust overall spectral Doppler gain. Note: Available on live or frozen image. One button optimization of spectral Doppler gain, baseline, and scale TGO (TGO Technology) With Doppler spectrum active, press to activate. Press twice to exit TGO. Note: Available on live image only. Alternates between the Doppler spectrum and the 2D image Update / View Press to alternate between Doppler / 2D. Note: Available on live image only. Adjusts the PW Doppler angle Steer Toggle left / right to reverse the steering angle. Note: Available on live image only. Available only on linear transducers. HOOD05162002850609 20180913 Color and Spectral Doppler Color and Spectral Doppler 32 Spectral Doppler Control Panel Control Panel Controls Function Adjusts angle correction Angle Press to cycle through 60 / 0 / 60° angle selections. Rotate to adjust values in 1° increments. Note: Available on live or frozen image. Reverses the Doppler spectrum (negative values display Invert above the baseline) Select to activate / deactivate. Note: Available on live or frozen image. HOOD05162002850609 20180913 L4g 33 Spectral Doppler Image Screen Toggle Key Controls Function Enters / exits Duplex or Triplex mode Triplex Select to activate / deactivate Duplex / Triplex. Note: Available on live image only. Adjusts sample volume size Gate Increase / decrease to adjust size. Note: Available on live image only. Adjusts the scrolling speed of the Doppler spectrum Sweep Increase to display less cardiac cycles. Decrease to display more cardiac cycles. Note: Available on live or frozen image. Mutes the Doppler audio Mute Select to activate / deactivate. Note: Available on live image only. Displays Full Screen Doppler Full D Select to activate / deactivate. Note: Available on live or frozen image. Color and HOOD05162002850609 20180913 Spectral Doppler Color and Spectral Doppler 34 Spectral Doppler Image Screen Toggle Key Controls Function Adjusts the wall filter Filter Select to adjust rejection of low frequency signals. Note: Available on live image only. Adjusts the sensitivity of the Trace tool when in Auto Stats Sensitivity Increase for higher sensitivity. Choices are 1–5. Note: Available on live image only. Defines the interval for refreshing the 2D-mode image Update Rate Select Off, 1 sec, 2 sec, 4, sec, 8 sec or EOS (End Of Sweep). Note: Available on live image only. Automatic trace and display of PW Doppler measurements Auto Stats Select to activate / deactivate. Select settings for data above, below or on both sides of the baseline. Note: Available on live or frozen image. HOOD05162002850609 20180913 L4g 35 DTI (DTI Doppler Tissue Activates the Doppler Tissue imaging feature for cardiac exams Imaging Capability) Press to activate / deactivate. Note: Available on live image only. Available on ACUSON NX2 Elite only. Adjusts the balance between the temporal and T/F Res frequency resolution of the Doppler spectrum (Time / Frequency Increase to increase temporal resolution. resolution) Decrease to increase frequency resolution. Note: Available on live image only. Adjusts the range of velocities displayed Baseline Increase / decrease to adjust the baseline. Note: Available on live or frozen image. Adjusts the pulse repetition frequency (PRF) Scale Increase / decrease to adjust the PRF. Note: Available on live image only. HOOD05162002850609 20180913 Color and Spectral Doppler Color and Spectral Doppler 36 Spectral Doppler Image Screen Toggle Key Controls Function Adjusts number of gray shades displayed DR (Dynamic Range) Increase for a softer / grayer spectrum. Decrease for a greater contrast spectrum. Note: Available on live or frozen image. Adjusts spectral Doppler frequency independent of the 2D or color frequency MultiHertz (frequency) Select a higher level to increase resolution. Select a lower level to increase penetration. Note: Available on live image only. Selects a processing curve that assigns echo amplitudes Map to gray shades in the Doppler spectrum Select desired Map from A – H. Note: Available on live or frozen image. Colorizes the Doppler spectrum Tint Select desired Tint from 0 – 11. Note: Available on live or frozen image. HOOD05162002850609 20180913 37 HOOD05162002850609 20180913 Color and Spectral Doppler Measurements and Calculations 38 Unlabeled Measurements Perform Measurement 1. Press 5. Roll the trackball to position the second XoBox caliper. 2. Select the desired measurement type and Press Caliper. 6. Press to complete the measurement. Distance Trace Length Area Angle A/B Ratio % Stenosis Volume Flow Volume 2D Ellipse Undo MDA Position 3. Roll the trackball to position the first caliper. ! enter into the exam report. 4. Press to anchor Unlabeled measurements do not TIP Measurements can be performed on frozen, CINE and stored images HOOD05162002850609 20180913 39 Labeled Measurements 1. Press 3. Roll the trackball to position the first x ... x caliper. 2. Roll the Trackball to select the desired Exam type and measurement label and press Set. 4. Press to anchor Thyroid Rt Lobe 5. Roll the trackball to position the second Lt Lobe caliper. Isthmus NOD 1 NOD 2 NOD 3 6. Press to complete and send the NOD 4 labeled value(s) to the patient report. NOD 5 NOD 6 NOD 7 NOD 8 The measurement label can be NOD 9 TIP NOD 10 selected before or after calipers are placed. NOD 11 NOD 12 1/2 HOOD05162002850609 20180913 Measurements and Calculations Measurements and Calculations 40 Edit Measurements (Labeled and Unlabeled) Edit Completed Measurement 1. Press (2) to activate calipers and 4. Select Delete All soft key using the Image cycle between active calipers. Screen / Toggle Key to delete all measurements. 2. Toggle Select Next soft key using the Image Screen / Toggle Key to cycle between calipers sets. 5. Select Undo soft key using the Image Screen / Toggle Key or the Select key to edit a trace measurement. 3. Select Delete using the Image Screen / Toggle Key or press the key to remove active measurement. Select HOOD05162002850609 20180913 L4g 41 Labeled Measurements 1. Press x ... x 2. Select MDA Position soft key using the Image Screen / Toggle Key to cycle through the available size and positions. HOOD05162002850609 20180913 Measurements and Calculations Measurements and Calculations 42 Report Review the Report Report 1. Press or select Report on the Image 6. Select Return or ESC hard key to exit the screen to enter / exit report page Report. 7. To edit the report, must be in worksheet. 2. There are two tabs for the report. One tab is Select worksheet on the soft key menu, roll Data, the other is Anatomy. the trackball to the desired measurement 3. Select Next to review additional and edit. measurements. 8. Select Summary using the Toggle Key to 4. Select Send Report to send to connected generate a revised Summary. external printer. 5. Press to store report as a thumbnail. Print Store 1 Only labeled measurements appear ! edited measurement. on the report. An * appears for any HOOD05162002850609 20180913 43 ---- Data Anatomy Indication 2 Measurement Thyroid TRV AP SAG Volume Echogenicity Rt Lobe Lt Lobe Isthmus Nodules TRV AP SAG Volume Echogenicity Vascularity NOD 11 NOD 12 NOD 13 NOD 14 NOD 15 Comments 4 6 Page 2/2 Prev Next 3 Work Sheet Send Report Return Work Sheet Summary 8 R 8 4 6 Image Screen HOOD05162002850609 20180913 Measurements and Calculations Measurements and Calculations 44 Summary Review the Summary 1. Press to activate the measurement package. Xooox Report 2. Press to enter / exit report page. 3. Select Summary on the Imaging Screen using the Toggle Key. 4. Select Export to USB to send to USB as a pdf file. 5. Select Print to print to a connected printer. 6. Select Exit to exit the Report. HOOD05162002850609 20180913 L4g 45 SIEMENS Thyroid Summary System Serial Number : 900040 Letter Header Thumbnails Patientinto | Results Patient Data Patient ID : 25_08_2016_07_08_01 Study Date : Sex : Age: Patient Name : Referring MD : Performing MD : Sonographer : Indication : Exam Specific Data Exam Type : Thyroid Height: Weight : Result Nodules Labels TRV (mm) AP (mm) 04 SAG (mm) Volume (cc) Echogenicity Vascularity NOD 1 49 Image 2 x 2 4 5 6 Export to USB Print Images 1 Exit S X A INS 4 5 6 Image Screen HOOD05162002850609 20180913 Measurements and Calculations Measurements and Calculations 46 Summary Import Images into the Summary 1. Press to activate the measurement 6. Roll the trackball to the desired image xoosx package. location in the Image section and press Report Set 2. Press to enter / exit report page. the Key to drop the image in report. 3. Select on the Imaging Screen using 7. To Delete the image, move the cursor over Summary the Toggle Key. the image and press the Set hard key to view Delete Image option and select Delete . 4. Select the header labeled Image to display format from the Summary Page. 5. Roll the trackball to the thumbnail image and press the Set key to highlight. TIP Up to 20 images can be stored to the Summary. HOOD05162002850609 20180913 47 SIEMENS Cerebro Vascular Summary System Serial Number : 900040 2×2 4 Thumbnails PatientInfo |Results SIEMENS SIEMENS B 9 -- SIEMENS SIEMENS 10 5 Export to USB Print Exit Images 11 S X A INS HOOD05162002850609 20180913 Measurements and Calculations Text, Arrows and Pictograms 48 Text Icons Control Function T Activates / deactivates text cursor and text Touch Screen menu. Set Home Sets default position for text cursor. Position Home Position Positions the cursor at the home location. Hide Text Temporarily hides text. Clear Screen Deletes all text, pictograms or arrows. Delete Line Deletes one line of text at the cursor. HOOD05162002850609 20180913 49 Page Key cycles between Anatomy, Position, User Def, and General Delete Word Deletes the last word. INS! Inserts or overwrites text when text cursor is active. < 1/1 > Displays the next or previous page, when available. Caps Lock HOOD05162002850609 20180913 Text, Arrows and Pictograms Text, Arrows and Pictograms 50 Arrows 1. Press the Arrow key on the keyboard. 7. Select Delete using the Toggle Key 2. Roll the trackball to position. to delete the last arrow. 3. Select Rotate soft key or turn Select key to 8. Select Delete All using the Toggle Key change arrow direction. to delete all arrows 4. Select Arrow Size using the Toggle Key 9. Press the Select key or Update to cycle to adjust arrow size. through multiple arrows. 5. Press Set to anchor. 10. Press the Arrow key on the keyboard to exit Arrow function. 6. Select New soft key or Press the Select key to add another arrow. TIP Unlimited arrows can be added. HOOD05162002850609 20180913 51 SIEMENS ACUSON NX2 07:05:5 System Serial Number : 900040 VF10-5 Thumbnails Patientinfo Results Thyroid 0 dB THI 8.0 MHZ 2 DR 60 dB Edge 2 Persist 3 RIS 3 Map A Tint 2 ASC 5 DTCE Med 43 fps 2 2 3 Select 6 9 4 3 P 100% MI 0.81 TIS 0.2 TIB 0.2 7 Delete New Select Arrow Size 20 Rotate 30" Rotate 90" O x Set Delete All 8 5 Rotate Arrow Select Arrow Arrow INS 6 9 4 3 3 7 8 9 HOOD05162002850609 20180913 Text, Arrows and Pictograms Text, Arrows and Pictograms 52 Pictograms Pictogram Pictogram 1. Select from the keyboard. 6. Press then Delete Pictogram option will , 2. Push up the Toggle Key for Pictogram Select appear on the Image Screen soft key. Use or Press to cycle through available the Toggle Key or Clear Screen to delete the Pictograms. Pictogram. 3. Roll the trackball to position the transducer icon. Pictograms are customized in the 4. Rotate the key to rotate the transducer TIP Presets Menu by selecting Presets / icon. Pictogram List. Select 5. Press to anchor. TIP Pressing Clear Screen also deletes any text or measurements on the image. HOOD05162002850609 20180913 53 SIEMENS ACUSON NX2 01:29:26 System Serial Number : 900040 L10-5v Thumbnails Patientinto |Results C-Vascular 0 dB THI 8.0 MHZ DR 56 dB Edge 2 Persist 2 R/S 3 4 Map B Tint 2 ASC 5 DTCE Med 48 fps Select Pictogram 1 3 4 cm 2 6 1 Fr2 P 100% .90 TIS 0.1 TIB 0.1 Images 13 Pictogram Select Delete Pictogram 2D X ( Rotate Marker Pictogram Picto A INS 2 6 HOOD05162002850609 20180913 Text, Arrows and Pictograms Data and Image Management 54 Review Images Review Images on Current Study Review Images from a Closed Study Review 1. Press and press Select to only see one 1. Press Patient Browser Hard Key. image. 2. Roll the trackball to the patient name patient 2. Select 1X1 to change the display format. and press the key twice to open. 3. Rotate the key to view more images. 3. Select 1X1 to change the display format. Select Review 4. Press or to exit. 4. Rotate the key 23/25 to view more images. 2D Select Review 5. Press or to exit. 2D HOOD05162002850609 20180913 L4g 55 Review Images Restart an Exam Delete Images from a Current Study or in Review 1. Press to activate cursor. 1. Select Select 2. Select an image on the thumbnail panel to 2. Select the exam from Local Disk. highlight. 3. Under Study tab on right side of screen, select 3. Select × located below thumbnail panel Reopen located below the list of exams to restart and answer prompt “Yes” to Delete. exam. Review 4. Or, press 4. Patient data screen will populate, press OK 5. Press to activate cursor. to open study. Select 6. Highlight an image from the Imaging Screen. 7. Select Delete from the Imaging Screen. TIP Images, clips and volumes can be added to a closed study within 24 hours. 8. Answer the prompt “Yes” to Delete. HOOD05162002850609 20180913 Data and Image Managment Data and Image Management 56 Teaching File 1. Select 7. To add images from multiple studies, follow 2. Select the exam from Local Disk and double- steps 1– 4, then select the desired teaching file. click to open. 8. Press Append to add the additional images. 3. Roll the trackball, highlight an image or clip and press the key. Repeat for all desired images. 4. Select eaching File using the Toggle Key on TIP Images and Clips stored in teaching the Control Panel. file removes all patient data. 5. Under Add Teaching File, name the file and press Close. 6. The teaching file is displayed in the Patient TIP The Teaching File selection does not appear on the Image Screen Browser. until an image is selected. HOOD05162002850609 20180913 57 Export Studies Export Study to DICOM Network Export Study to CD-R/DVD in DICOM 1. Select the patient name in the Patient Browser. 1. Insert CD-R/DVD. 2. Under Network, select the desired 2. Select the patient name in the Patient Browser. Destination. 3. Select Local Disk from the Drop Down under 3. Select Send. Export / Import. 4. Select CD/DVD and select DICOM as the export format and select Export. Images automatically send to PACs Hold CTRL to select more than one patient TIP if the system is configured to send name. A showcase DICOM viewer will be burned during the exam or at the end of TIP onto the CD-R or DVD with the patient data if the exam. selected in the Presets Menu (Presets /Archive / CD/DVD. HOOD05162002850609 20180913 Data and Image Managment Data and Image Management 58 Import / Export Studies Export Study to USB in PC Format (TIFF or AVI) Import Study from CD-R/DVD to Local Database 1. Insert USB. 1. Insert CD-R/DVD. 2. Select the patient name in the Patient 2. Select CD/DVD from Export / Import in the Browser. Patient Browser. 3. Select USB and the Tiff /AVI export format. 3. Select patient name on the CD/DVD. 4. Select Export. 4. Select Import. Export Study to USB in DICOM Format Import Study from USB to Local Database 1. Insert USB. 1. Insert USB. 2. Select the patient name in the Patient 2. Select USB from Export / Import in the Patient Browser. Browser. 3. Select USB and the DICOM export format. 3. Select patient name on the USB. 4. Select Export. 4. Select Import. HOOD05162002850609 20180913 L4g 59 HOOD05162002850609 20180913 Data and Image Managment The products / features mentioned in this document may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details. Images used in this guide are for educational purposes only. They have been modified or compressed and may not reflect the actual image quality of the system. ACUSON NX2, Advanced SieClear, Clarify VE, DTI, DTO, Dynamic TCE, MultiHertz, SieClear and TGO are trademarks of Siemens Medical Solutions USA, Inc. Siemens Healthineers offers a wide range of general imaging products – ACUSON S Family, ACUSON X700, ACUSON NX Series, ACUSON P500 and ACUSON X Family ultrasound systems. The ACUSON NX2 Series delivers essential technology in a scalable, upgradeable system designed for smart scanning to allow consistent performance and impactful results. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 685 East Middlefield Road Phone: +49 9131 84-0 Mountain View, CA 94043, USA siemens.com/healthineers Phone: +1-888-826-9702 siemens.com/ultrasound Published by Siemens Medical Solutions USA, Inc.· Order No. A91US-517-1C-4A00 · Printed in Germany · 5598 0218.X · HOOD05162002850609 · © Siemens Medical Solutions USA, Inc., 2018 L4g

  • NX2
  • ACUSON NX2
  • Quick Reference Guide
  • System Overview
  • 2D
  • M-mode
  • Color
  • Doppler
  • Measurements
  • Text
  • image