Acuson NX3 Turnover Workbook
SIEMENS ACUSON NX3 Ultrasound System ACUSON NX3 ultrasound System ACUSON NX3™ Ultrasound System Turnover Workbook SIEMENS Healthineers www.usa.siemens.com/education I. Contact Information Summary Welcome to Siemens Healthineers Visit www.usa.siemens.com/clinicaleducation for more information regarding the current Siemens Siemens Healthineers is dedicated to helping you get the Clinical Training and Continuing Education portfolio. most out of your investment throughout the entire product life cycle and beyond. Our goal is to enable you Discover. Try. Buy. on webShop to take technology further, profitability higher, and patient care to the next level. Find the information, resources, and Do you want to “Discover. Try. Buy.” options, accessories, tools you need to get the most out of your recent and clinical education to make the most of your investment and stay up-to-date. imaging equipment? Discover images, case studies, Visit www.usa.siemens.com/Welcome2Healthcare. and video demonstrations with the latest clinical applications. Try advanced applications utilizing Clinical Training and Continuing Education free software trials. Buy applications, coils, clinical education, and accessories, conveniently at any time. Customer Care Center - Clinical Application Support: Visit www.usa.siemens.com/webShop today! Call 1-800-888-7436 Siemens Training Centers Troubleshooting assistance • Immediate assistance for software • Siemens Clinical Education applications and workflow issues Training Center – TDC2 Please provide the Functional Location Number when • 110 Mac Alyson Court calling for assistance. Cary, NC 27511 Clinical Education Offerings: Call 1-888-221-8010 (follow the prompts) Classroom Training (Offerings, Registration • & Scheduling) Educational Symposia • On-site Training • Printed Self-studies • Virtual Education (Offerings & Registration) • Workshops & Fellowships • 2 II. Contents I. Contact Information Summary .....................................................................................................................................2 II. Contents ............................................................................................................................................................................3 1. System Overview ..............................................................................................................................................................4 2. Getting Started ............................................................................................................................................................... 37 3. Transducers and Presets ..............................................................................................................................................50 4. 2D and M-mode Optimization ................................................................................................................................... 67 5. Doppler Optimization ...................................................................................................................................................98 6. Measurements and Reports ......................................................................................................................................125 7. Text Annotations, Pictogram and Arrow ................................................................................................................158 8. Connectivity Overview ................................................................................................................................................182 9. Cardiology - Part 1 .......................................................................................................................................................201 10. Cardiology - Part 2 ................................................................................................................................................... 224 11. Cardiology - Part 3 .................................................................................................................................................... 238 3 Turnover Workbook | ACUSON NX3™ Ultrasound System 1. System Overview SIEMENS Healthineers ---- System Installation Training System Overview ACUSON NX3™ Ultrasound Restricted (t) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 4 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives . Identify external features CUSON NX3 Locate transducer ports, power panel and standby mode Describe connection of peripherals · Summarize cleaning procedures Siemens Medical Solutions USA, Inc. 2015. Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 5 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers' System Dimensions System Height: 144.7 - 158.6 cm ACUSON NXE (57 - 62.4 in) System Width: 54 cm (21.3 in) System Depth: 92.3 cm (36.3 in) System Weight: 75 kg (165 lbs) Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only These are the maximum physical dimensions of the ACUSON NX3™ ultrasound system. The weight noted is for a system without documentation devices. Notes 6 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Positioning the System ACUSON NX3 Elite system only Height-adjustable control panel Lock lever Siemens Medical Solutions USA, Inc. 2015 Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Pull the lock lever located under the control panel handle towards you to adjust the height of the control panel. Note: Height adjustable only available on the ACUSON NX3 Elite system. The control panel vertical adjustment is 11 cm. Notizen 4 Notes 7 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Articulating Arm and Monitor Swivel right or left +/- 80º Tilt 15º up and 80º down Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The articulating arm allows the movement of the monitor, independent of the system and of the control panel. Tilt or swivel the monitor for optimal viewing while scanning. Use the monitor handle to extend the monitor forward over the control panel or back behind the touch screen. Fold the monitor down during transport. Notizen 5 Notes 8 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Cable Management QUEMEIR Power Supply Cord Hanger Transducer Cable Hangers Siemens Medical Solutions USA, Inc. 2015. Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Cable management occurs in five areas: 1. The cable hangers on the rear panel houses the power supply cord. 2. The transducer holders on both sides have hangers to hold the transducer cables in place. 3. The right front hook elevates the transducer cables to prevent them from being run over by the system and damaged. 4. The hangers on the front of the peripheral bay keep the transducer cables off the floor and help to prevent tangling (the peripheral bay is optional and therefore the hangers on the peripheral bay are optional). 5. A smaller hanger located just above the transducer ports keep the cables secure to the system. Notizen 6 Notes 9 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Storage Bins Cable collector or chart storage Removable rear tray and additional storage Rear basket for cables from I/O € Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The bins located on both sides of the system can be used to keep the transducer cables off the floor and help to prevent tangling. The bins can also be used to store disconnected transducer connectors or patient charts. Additional storage is located in the back of the system for gel bottles or other items. Storage for cables from peripherals is located beneath the input/output panel in the back off the system. Notizen 7 Notes 10 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS CD/DVD Healthineers OGGI 99999 DVD-R/RW & CD-R/RW Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only A CD/DVD read/write drive is available for user presets, system software updates and upgrades, patient data storage and retrieval. Press the eject button on the CD/DVD drive on the left side of the ultrasound system to eject the CD/DVD tray. Compatible with removable 650 MB, 700 MB and 790 MB CD-R and 650 MB or 700 MB CD-RW. Removable 4.7 GB single layer DVD and 8.5 GB single side double layer DVD. The system supports the following data export file formats RTF, PDF, TIFF, AVI, JPG and DICOM. Notizen 8 Notes 11 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Wheel Locks Unlocked (wheels can swivel and roll) Locked (wheels cannot swivel or roll) € Siemens Medical Solutions USA, Inc. 2015. Restricted < Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Set the front and rear brakes individually as either locked or unlocked by moving the lever. Notizen 9 Notes 12 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Monitor Settings Microphone On / Off LED MENS Microphone ACUSON NX3 Monitor On / Off LED Ultrasound System Task Light On / Off Monitor Brightness Up / Down Monitor Menu Task Light € Siemens Medical Solutions USA, Inc. 2015. Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The task light can be turned on or off by pressing the task light on/off control. The task light provides additional lighting for the keyboard. The monitor brightness can be adjusted using the monitor menu and Up/Down controls shown here. The microphone can be turned on or off under the Presets>Customize Keys menu and programed under one of the customizable 1-5 Keys or the UD (user-defined) key. When the microphone is activated, the microphone LED indicator will be lit. For consistency in image reproduction, make any adjustments to the monitor prior to adjusting the print quality of installed documentation devices. Notes 13 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Touch Screen Mode Indicators Advanced Features Indicators 2 USB Ports Soft Keys Selections Soft Keys Siemens Medical Solutions USA, Inc. 2015. Restricted O Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The touch screen displays the activated operating modes and highlights the indicator for the priority mode. The touch screen also displays the available advanced features for a mode or function. There are two USB 2.0 ports on the right side of the touch screen. USB allows transfer of images, clips, volumes, presets, report, summaries and service log files. The touch screen displays soft key selections assigned to the push-and-rotate soft keys located directly below the touch screen. Active touch screen controls are back-lit in blue. Available touch screen controls are back-lit in white. Unavailable controls are grayed out. Notes 14 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Control Panel Layout Power/QuikStart DGC (Stand-by) Imaging Modes Workflow Controls O TGO UD (User-defined) Keys Depth, Zoom, Focus, 1-5 Dual, UD Keyboard O Print/Store/Clip Angle, Steer, Select Freeze Homebase € Siemens Medical Solutions USA, Inc. 2015. Restricted E) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Power/QuikStart stand-by is located in the top left corner of the control panel. QuikStart Stand- by Mode reduces the time required for power-up and power-down by allowing the system to enter a specialized standby mode. The Workflow Controls are New Patient (patient registration), Exam (select or customize an exam type), Review (review images or studies) and Report (view/edit/print patient report). Special functions can be assigned to the five user-defined keys under Presets>Customize Keys>Key Function. For example, Transducer selection, Trapezoid, U/D Flip, L/R Flip can be selected from the drop-down menu for each key. Use the alphanumeric keyboard for entering data, accessing the Help menu, activating the Biopsy guidelines, adding Text, Body Markers and Arrows to images, and configuring system presets Angle is a dual-function control that can be rotated/pressed to adjust the spectral Doppler angle or activate Anatomical M-mode in a cardiac study. During 3D/4D imaging, this control rotates the volume around the "x" axis. Notes 15 Turnover Workbook | ACUSON NX3™ Ultrasound System For linear array transducers, the Steer control steers the 2D image and positions the M-mode or Doppler cursor or the color region of interest (ROI). Rotating the Select control either highlights a selection or cycles through available selections; pressing the Select control either adjusts the setting for the highlighted selection or activates the highlighted selection. For example, when in the Review menu, pressing Select toggles the full-screen display format with the most recently selected display format; rotating the Select control pages through the stored images. The active function of the Select key displays next to the status icon at the bottom of the imaging screen. The Home Base area provides access to the trackball, Select keys, Escape, Measurements, and Update key. The Freeze key is on the front right of the control panel. Print Store 1 and Print Store 2 are configured for the preferred destination under Presets>Customize Keys> Print/Store 1 or 2. Clip Store can be configured to store a volume, clip or image under Presets>Customize Keys> Clip Store Key. Rotating the Depth/Zoom control changes the imaging depth. Pressing Depth/Zoom activates Zoom to magnify the image. Rotating the control in Zoom or HD Zoom changes the magnification level. High density (HD) zoom increases the images size, detail resolution and frame rate in a region of interest. During 3D/4D imaging, pressing HD Zoom displays the single volume image on the screen. Rotating the Focus control positions the focal zones in the image; pressing the control changes the number of focal zones. Pressing Dual displays two separately acquired images, side-by-side. The UD (user-defined) control can be customized under Presets>Customize Keys> UD Key to perform a variety of functions, similar to the UD Keys 1-5. Pressing TGO (Tissue Gain Optimization) is a one-button image optimization to automatically adjust image brightness for the tissue type being imaged and equalizes Notizen 12 Notes 16 Turnover Workbook | ACUSON NX3™ Ultrasound System the overall image gain. During spectral Doppler, pressing TGO automatically optimizes the selected parameters configured under Presets>Display>Doppler/M- mode>Doppler Auto Optimization. Imaging modes (2D, M-mode, Color, Power Doppler, PW, CW, 3D/4D) are accessed here. Notizen 12 Notes 17 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Home Base Area Left Set Update ( View Update/View Trackball Right Set Escape Caliper/Measure ESC Caliper Wrist Support € Siemens Medical Solutions USA, Inc. 2015 Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Set keys are mode-dependent and confirms the selection of a specific function or command. For example, you can use them to anchor calipers or to select a menu item or image graphic. In the center of the Home Base area is the trackball which positions image graphics such as the color ROI (region of interest), measurement markers and text. The active function of the trackball displays next to the status icon at the bottom of the imaging screen. On Freeze, the trackball defaults to the Cine function. The Escape key exits the currently displayed mode, function or page and reactivates the previous mode, function or page. The active function of the Escape key displays next to the status icon at the bottom of the imaging screen. A wrist support is provided at Home Base. Caliper activates the measurement menu. During the measurement function, pressing Caliper toggles the measurement marker with the Measurement menu. Notes 18 Turnover Workbook | ACUSON NX3™ Ultrasound System The Update key function is mode-dependent. For example, it can be pressed to toggle a live image with a frozen display during mixed-mode imaging, cycle through measurement markers for editing, or cycle through annotation labels. During 3D/4D imaging, pressing Update starts or cancels the acquisition process. The active function of the Update key displays next to the status icon at the bottom of the imaging screen. The location of the Set keys, Escape and Caliper an be customized under Presets>Customize Keys>Key Function>Home Base Key. Notizen 13 Notes 19 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives Identify external features ACUSON NXE Locate transducer ports, power panel and standby mode · Describe connection of peripherals · Summarize cleaning procedures Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 20 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS . Healthineers Transducer Ports Optional Aux 1 and ECG Four Universal Ports Aux CW € Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The system has four universal transducer ports as well as an auxiliary CW (continuous wave) port. The Aux 1 port and ECG connector are located above the transducer ports to the left of the peripheral storage bay. Notes 21 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Power Panel MAINS circuit MAINS Voltage breaker Selector Equipotential Accessory Output connector Voltage Selector Power cord Status Indicator connection Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is the AC tray panel located at the back of the system near the floor. This is the primary power plug and circuit breaker. Service accesses the status indicator for the battery and incoming power in this location. Notes 22 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Battery Pack for Optional QuikStart Standby Mode Healthineers Portable Studies . System must be connected to a power source to image Battery Pack location € Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The QuikStart feature for portable studies reduces the time required for power-up and power-down by allowing the system to enter a specialized standby mode. Standby mode power-down in 10 sec; complete boot-up in less than 10 sec; Standby time: > 35 min, Full recharge: < 180 min. The system can maintain the standby status for approximately 30 minutes when the system's power cord is not plugged into the power supply. The battery pack is located on the front side of the ultrasound system, where the power is located. The battery pack cover must be removed by a Siemens Service Representative to access the battery pack. The battery pack charge indicator LED is located at the rear of the system, on the AC Tray panel. A green blinking LED indicates that the battery is actively charging. A solid green LED indicates that the battery pack is fully charged. If the LED is not illuminated, then there is a problem with the battery pack, or the battery pack may be missing. Notes 23 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Objectives Healthineers · Identify external features ACUSON NX3 · Locate transducer ports, power panel and standby mode · Describe connection of peripherals · Summarize cleaning procedures Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 24 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Input/output Panel Healthineers 4 USB Ports Ethernet Connection DVI In/Out VGA Out Audio In/Out DVI In/Out Accessory Power Outlet Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The rear panel supports connections for: 4 USB printer or storage device 3 DVI (external monitor: digital or analog output) 2 Audio In/Out Ethernet VGA Out 4 Accessory Power Plug Notes 25 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Optional Footswitch Connect to USB port on the back of the system. User-programmable Dual-pedal Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Use the optional footswitch as an alternative to operating keys on the control panel. Customizable under: Presets>Customize Keys>Left Pedal Presets>Customize Keys>Right Pedal Use the system presets to assign each footswitch pedal to a function. For example, print to a black and white or color printer, store to the system's hard drive, freeze or unfreeze the image, etc ... Notizen 20 Notes 26 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Optional Peripherals Healthineers' Peripheral storage bin SIEMENS € Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Up to 2 compatible, approved documentation devices (B/W printer and color printer/DVR recorder) can be integrated into the system cart and controlled from the system control panel. The system supports the following data export file formats RTF, PDF, TIFF, AVI, JPG and DICOM. Notizen 21 Notes 27 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives · Identify external features ACUSON NX3 Locate transducer ports, power panel and standby mode Describe connection of peripherals . Summarize cleaning procedures € Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 28 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Care and Cleaning - Filter Healthineers Air Filter location ® Siemens Medical Solutions USA, Inc. 2015. Restricted ED Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The air filter is located on the front of system and should be cleaned weekly to maintain proper system cooling. To remove and clean the air filter: 1. Power off and unplug the power cord from the power outlet. 2. Grasp the air filter tray and pull it out of the system. 3. Rinse the air filter tray with running water and allow the filter to completely dry. 4. To hasten drying, you may gently shake the air filter tray, or blot the filter with a clean, lint-free cloth. 5. Slide the air filter tray back into the ultrasound system. 6. Plug the power cord into the power outlet. Note: Do not insert the air filter tray into the ultrasound system with a wet filter as this can damage the system. Notizen 23 Notes 29 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Care and Cleaning - System Surfaces Approved Disinfectant Wipes for the Ultrasound System Surfaces The following matrix provides a list of approved disinfectant wipes for use on the ultrasound ACUSON NX3 system and surfaces of the listed components Sani-Cloth Sani-Cloth Ultrasound System Sani-Cloth and-Cloth Sani-Cloth Super LEJ each Wipe and Cloth Ultrasound System Transducer Liners Trackball Assembly "or any bleach wige woh <1% sodium hypochiorte and no other * * conpantle 14 = not applicabie (not testes ACUSON NX3 € Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To clean the surface of the ultrasound system: 1. Power off the ultrasound system and unplug the power cord from the power outlet. 2. Use a clean gauze pad or lint-free cloth, lightly moistened with a mild detergent, to wipe the surface of the ultrasound system. Ensure that cleaning solution does not seep into the control panel, keyboard, or any other openings. 3. After cleaning, use a clean, lint-free cloth to dry the surface. 4. Use an approved disinfectant wipe for disinfecting the ultrasound system and accessories. Note: To avoid the possibility of static shock and damage to the system, avoid the use of aerosol spray cleaners on the monitor screens. What not to do: 1. Never apply cleaning fluid directly to the screen. The screen is made of very fine layers that absorb moisture . 2. Never use alcohol (e.g. specialty electronics cleaners) or ammonia-based cleaning fluid (e.g. glass cleaner) on the screen. These may strip anti-reflective coatings off the screen and cause clouding. Notizen 24 Notes 30 Turnover Workbook | ACUSON NX3™ Ultrasound System 3. Never use paper towels or general purpose cleaning rags as they are abrasive to the LED Screen. Notizen 24 Notes 31 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Care and Cleaning - Trackball Healthineers Update / View Approved Disinfectant Wipes for the Ultrasound System Surfaces The following matrix geovides a list of approved disinfectant wipes for use on The ultrasound system and surfaces of the listed components Sani-Cloth Sani-Cloth Sani-Cloth Sani-Cloth Sani-Cloth Super AFJ Bleach Wipe' HB Plus Sani-Cloth Ultrasound System Transducer Liners Trackball Assembly "or any tieach wige woh <1% sodium hypochigrie and no other ac * * compostle 14 = not applicabie (not tesseso ESC Caliper Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Remove the trackball for cleaning: 1. Rotate the bezel counterclockwise. 2. Remove the trackball. 3. Clean the trackball with tissue and isopropyl alcohol. 4. Clean the Teflon seal (located in the front panel bezel) with a tissue and isopropyl alcohol. 5. Clean the inside of the trackball assembly with a cotton swab and isopropyl alcohol. 6. Use an approved disinfectant wipe for disinfecting the trackball assembly. 7. Allow the assembly parts to completely dry before reassembly. 8 . Replace the trackball and front panel bezel . Notizen 25 Notes 32 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Care and Cleaning - Transducer Holder Liners Approved Disinfectant Wipes for the Ultrasound System Surfaces The following matrix provides a list of approved disinfectant wipes for use on The ultrasound system and surfaces of the listed components Sani-Cloth Sani-Cloth Sani-Cloth AF AFJ Bleach Wipe' Flus Super Sant Cloth Ultrasound System Transducer Liners Trackball Assembly "or any tieach wige ich <1% sodium hypochigrie and ents N4 3 not a Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To clean the liners of the transducer holder: 1. Remove the liner from the transducer holder. 2. Clean the liner under running water, using a mild detergent and dry with a lint-free cloth. 3. Use an approved disinfectant wipe for disinfecting the transducer holder liners. 4. Reinsert the liner into the transducer holder. Notizen 26 Notes 33 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Care and Cleaning - Optional Integrated Gel Warmer Unplug and remove gel warmer from system Remove bottom cap for cleaning Re-attach after drying completely € Siemens Medical Solutions USA, Inc. 2015. Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Remove the gel warmer and cable connector from the system for cleaning. 1. Remove the bottom cap (indicated here). This improves removal of ultrasound gel, lotion or other substances from the inside. 2. Clean with a lint free cloth moistened with a mild detergent. 3. Use an approved disinfectant wipe for disinfecting the gel warmer. 4. Re-attach after drying completely and plug back into the gel warmer power supply. Notizen 27 Notes 34 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary Identify external features Locate transducer ports, power panel and standby mode Describe connection of peripherals Summarize cleaning procedures € Siemens Medical Solutions USA, Inc. 2015. Restricted < Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 35 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers Questions Siemens Medical Solutions USA, Inc. 2015. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 36 Turnover Workbook | ACUSON NX3™ Ultrasound System 2. Getting Started SIEMENS Healthineers System Installation Training Getting Started ACUSON NX3™ Ultrasound System Restricted Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 37 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives (CUSON NXE · Describe System Security Demonstrate Patient Registration . . · Understand Query / Retrieve / Edit Perform the steps to End Exam Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 38 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers System Security Login and Password configurable in Presets>Authorization ------- -- Cirt END Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The system may be configured for patient data protection by requiring users to login with a unique username and password. There are two levels of access: S Standard: Provides access to the Study screen or Image screen for viewing and transferring patient data. Users can also change their own passwords. S Administrator: Provides the same access as for standard accounts plus the ability to create and manage accounts. The user administrator/s should be identified during Essential System Training (EST) at the time of system installation. Account configuration occurs via the Presets button on the keyboard, and selecting Authorization on the left of the displayed screen. Notizen 3 Notes 39 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Objectives Healthineers ACUSON NX3 · Describe System Security · Demonstrate Patient Registration . . . Understand Query / Retrieve / Edit . Perform the steps to End Exam Restricted ( Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 40 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Patient Registration Configuration Healthineers General 2 Peripheral Patient ID IT. AutoStore Now Patient Form Customize Entry Order DVR Device Type None Common Mode Delete Pictogram on Unfreeze Key Function Record/Pause ~Record/Stop P Delele Text on Unfreeze Barcode Reader Pictogram Location r. Upper Right * Lower Right Scan a barcode Font Size 18 Arow Size Medium (Type2) Patient Registration Original DICOM Patient Registration Local Host | Storage Server | Worklist Server | MPPS Server | B/W Printer | Color Printer | Query/Retrieve Customize Entry Order .. Restricted ( Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Patient Registration can be configured in the System Presets menu. This is accessible using the Presets button on the top left of the keyboard. Within System Presets, the user can customize factors in 3 menus: 1. General 2 (General 2 > Patient ID > Customize Entry Order) to customize data entry order 2. General 2 (General 2 > Patient Registration) to customize data entry requirements: a. Original uses the standard patient registration form with conventional requirements for data entry, and id required for use with a barcode reader. b. e-entry displays an overlay of patient identification fields on the image screen. 3. Peripheral (Peripheral > Barcode Reader). This identifies the information in the barcode used by the facility. 4. DICOM (DICOM > Worklist Server > Streamlined Search). This prompts the system to begin a worklist search by searching procedures scheduled for the next 24 hours. Notizen 5 Notes 41 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Patient Registration Methods · Manual Entry Patient Exam Last Name Transducer VF12-4 First Name Esan Breast Barcode Entry Accession No Patent ID Indication Date of Birth DOIMWYYYY Sex. Male . Female - Unknown Age History · Worklist Recall "eight |cin] Additional info Weight [kol Institution Holerting HD · Registration Bypass* Performing HD Sonograph OK Cancel Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only There are 4 ways of registering a patient: 1. Manual Entry. Patient data can be entered manually from the Patient Registration screen. This is accessed by the control panel (New Patient) or the keyboard (Patient Data). The user is pushed to the imaging screen by pressing OK. 2. Barcode Entry. The text cursor is placed in the first entry field on the Patient Registration screen. The barcode is then scanned to import the patient name and ID, the performing physician and the sonographer). Additional details are completed manually. The user is pushed to the imaging screen by pressing OK. 3. Worklist Recall. Add patient information manually, then press Worklist on the upper left side of the form. The system displays the Worklist Search screen containing data entered on the patient data form. 4. Registration Bypass. Registration Bypass allows the user to immediately begin the examination without registering the patient. By pressing the control panel key assigned to the store function, the system opens a new study, identifying the Patient Name as an asterisk (*) and the Patient ID as the opening date and time. Patient Information can be edited up until the exam is ended. Notizen 6 Notes 42 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives ACUSON NXE Describe System Security · Demonstrate Patient Registration . . . Understand Query / Retrieve / Edit . Perform the steps to End Exam Restricted Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 43 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Query / Retrieve Healthineers Search and import via Patient Browser EN Alt Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To retrieve patient information using the query / retrieve function: required patient information is added to the search fields by pressing Patient Browser on the keyboard and clicking Query. The system will display the study that matches the criteria. To import the selected study to the system hard disk, select the required study/ies and then click Retrieve. The user can import studies from an information system server to the ultrasound system's hard disk. This can occur only if / when the information system administrator has configured the sever for the query / retrieve function. Please note: the imported studies from the Query Server do not support the measurement function, report, teaching files, structured reporting, or software applications. Notizen 8 Notes 44 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Edit Edit via Patient Data Edits can occur only during the patient examination Ctrl END Restricted D Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Entries to the Patient Data form can be edited at any time during the patient examination. Note: studies imported from the Worklist server cannot be edited for the following patient data: Patient Name, Patient ID, Accession Number, Date of Birth/Age, Sex. To edit the patient data on an open study, press the Patient Data key on the keyboard, use the keyboard to update entries, and click OK to save the revisions and redisplay the image screen. Notizen 9 Notes 45 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives ACUSON NXE Describe System Security · Demonstrate Patient Registration . . . Understand Query / Retrieve / Edit . Perform the steps to End Exam Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 46 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS End Exam Healthineers Review New Patient Exam Review Report 2 ? TX 2 E O W E R T Y A S D G H END Z X N Al Alt A Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only When an exam is ended, the system removes the patient information from the image screen. The system automatically completes the patient examination when the system shuts down. To actively end an examination, the user may use the END key, Patient Browser or the Review screen. There are three workflow scenarios: 1. To end the current patient examination when an image or clip is stored, press Patient Browser on the keyboard, or press Review on the control panel. Then tap Close Study. 2. To end the current patient examination when image or clip is not stored, press Patient Browser on the keyboard, or press Review 2. on the control panel. The study screen will display. Click Close in the Study field. 3. To end the current patient examination and to begin a new examination, press New Patient on the control panel. Enter Patient Data, 3. click OK. Note: the function of the END key can be configured in System Presets (Customize Keys > END key). It can be set to: inactive, to close a study or to close a study and reload boot-up setting. Notizen 11 Notes 47 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary Describe System Security Demonstrate Patient Registration Understand Query / Retrieve / Edit Perform the steps to End Exam Restricted ( Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No Notes Notes 48 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Questions Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No Notes Notes 49 Turnover Workbook | ACUSON NX3™ Ultrasound System 3. Transducers and Presets SIEMENS Healthineers System Installation Training Transducers & Presets ACUSON NX3™ Ultrasound System Restricted (!) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 50 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives CUSON NX Recognize Transducer Management · Identify EC10-5w and VF16-5 Features · Outline Transducer Cleaning Procedure · Demonstrate QuickSet D Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes. Notes 51 Turnover Workbook | ACUSON NX3™ Ultrasound System Transducer Management ACUSON NX3 USOMN D Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only There are three areas for transducer management: 1. Transducer holder/s Caution: Transducer holders have variable sizes both in depth and diameter. To avoid transducer damage, you must use the holder and/or insert provided for transducers that have small or large diameter handles or for specialty transducers. 2. Transducer cable hanger 3. Transducer hooks Note: transducers and connectors can also be stored in side bins on either side of system. Notizen 3 Notes 52 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives CUSON NX Recognize Transducer Management · Identify EC10-5w and VF16-5 Features · Outline Transducer Cleaning Procedure · Demonstrate QuickSet D Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes. Notes 53 Turnover Workbook | ACUSON NX3™ Ultrasound System Acoustic Efficiency Hi-K PZT PMN-PT Thermal conductive single crystal graphite Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only A transducer converts an electrical signal into sound and then back from sound to an electrical signal. The generation of sound also creates heat. Each layer, as shown in the left image, results in small decreases in the signal and areas to hold heat. To reduce these losses, Siemens transducers use: . High dielectric elements for electrical matching. Low loss ceramics for less heating. . Low loss lens for sensitivity. · Thermal conductive materials for improved heat dissipation. . Multiple matching layers to reduce near field artifact . Notizen 5 Notes 54 Turnover Workbook | ACUSON NX3™ Ultrasound System Hanafy Lens Increased Bandwidth LA. Conventional Crystal Frequency Hanafy Lens @ Siemens Medical Solutions USA, Inc. 2015 Global Cinical Education & Training Speaker Notes Only And don't forget to tell the sophisticated Hanafy Lens story. (The VF16-5 transducer has a Hanafy Lens. Note: the EC10-5w does not.) The Hanafy lens in the transducer increases resolution through the use of a concave crystal. The thinner portions generate the high resolution frequencies providing near field resolution. The thicker portions generate lower frequencies providing far field resolution. This increase in bandwidth allows for the creation of an image with a uniform echo texture and penetration. This crystal shape also changes the beam profile (as seen in the right image). The tightly focused beam results increases lateral and axial resolution at all depths. Creating a tightly focused (adaptive) beam throughout the field of view. Notizen 6 Notes 55 Turnover Workbook | ACUSON NX3™ Ultrasound System EC10-5w Transducer · ACUSON NX3™ Elite System Only 192 elements . Frequency bandwidth 4 - 10 MHz . 220º FOV Exam Types: Early OB, OB, GYN, Urology D Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes. Notes 56 Turnover Workbook | ACUSON NX3™ Ultrasound System EC10-5w Transducer 75% wider image Conventional View Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training E.g. uterine fibroids, enlarged prostate (Benign prostatic hypertrophy) Be able to see adnexal masses more easily and their relationship to the uterus. Improved patient comfort as less angling of transducer. Notizen 8 Notes 57 Turnover Workbook | ACUSON NX3™ Ultrasound System EC10-5w Transducer Conventional View Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training E.g. uterine fibroids, enlarged prostate (Benign prostatic hypertrophy) Be able to see adnexal masses more easily and their relationship to the uterus. Improved patient comfort as less angling of transducer. Notizen 9 Notes 58 Turnover Workbook | ACUSON NX3™ Ultrasound System VF16-5 Transducer · NX3 Elite Ultrasound System VF16-5 ACUSON X700M ultrasound system compatible 192 elements · Frequency bandwidth 5 - 13.3MHZ Footprint 34.6mm Exam Types: Breast, CV, EM, MSK, Penile, Testes, Thyroid D Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes. Notes 59 Turnover Workbook | ACUSON NX3™ Ultrasound System VF16-5 Transducer VF 16-8 Thyreld VF15-5 EM THI 10 7 Mhz 0 BB THI 10 7 MHZ DR CO BB Edge 1 Persist 3 Edge 2 Persist 3 RIS 4 RSS Map G Map G Tint 2 Ting 2 ASC DICE Med ASC 3 OTOE Med 25 fps 29 fus Siemens Medical Solutions USA, Inc. 2015 Global Cinical Education & Training Speaker Notes Only No Notes Notizen 11 Notes 60 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives ACUSON NX · Recognize Transducer Management . Identify EC10-5w and VF16-5 Features Outline Transducer Cleaning Procedure · Demonstrate QuickSet D Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes. Notes 61 Turnover Workbook | ACUSON NX3™ Ultrasound System Transducer Cleaning Procedure Do: Do Not: Visually inspect Sterilize using hot steam, cold Disconnect gas, or Ethylene Oxide (EO) Use approved substances methods Observe immersion levels Spray cleaner directly onto the transducer Clean transducer holders Immerse for >1 hour D Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Before cleaning/disinfecting, be sure to visually inspect and disconnect all transducers. Do not use a transducer which has a cracked, punctured, or discolored casing or a frayed cable. Use only approved cleaners/disinfectants listed in the system manual. Do not use abrasive cleaning agents, organic solvents such as benzene, isopropyl alcohol, or phenol-based substances, or cleaning agents containing organic solvents. Do not use a spray cleaner directly on a transducer as this may force cleaning fluid inside the housing. In addition to the transducers themselves, the liners of the transducer holders should be regularly cleaned. Notizen 13 Notes 62 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives ACUSON NXE Recognize Transducer Management Identify EC10-5w and VF16-5 Features · Outline Transducer Cleaning Procedure · Demonstrate QuickSet Siemens Medical Solutions USA, Inc. 2015 Global Cinical Education & Training Speaker Notes Only No speaker notes. Notes 63 Turnover Workbook | ACUSON NX3™ Ultrasound System Quick Sets Exam 128 Quick Set Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Quick Sets are selected by either pressing Quick Set on the keyboard, or EXAM on the control panel. Quick Set is best used for Quick Set creation ; Exam is the quickest way to access your Quick Sets. A maximum of 128 Quick Sets are allowable on the system at one time. Quick Sets can be created, overwritten (edited) and deleted. Users can define which Quick Set (or exam-type) is the default. Quick Sets can be backed up / restored via CD/DVD or a USB. Note: Quick Sets should only be transferred between systems with the same product name. Notizen 15 Notes 64 Turnover Workbook | ACUSON NX3™ Ultrasound System Summary Recognize Transducer Management Identify EC10-5w and VF16-5 Features Outline Transducer Cleaning Procedure · Demonstrate QuickSet Siemens Medical Solutions USA, Inc. 2015 Global Cinical Education & Training Speaker Notes Only No Notes Notizen 16 Notes 65 Turnover Workbook | ACUSON NX3™ Ultrasound System Questions Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No Notes Notes 66 Turnover Workbook | ACUSON NX3™ Ultrasound System 4. 2D and M-mode Optimization SIEMENS Healthineers System Installation Training 2D and M-mode Optimization ACUSON NX3™ Ultrasound System Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 67 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives SIEMENS Healthineers Review the Imaging Screen for 2D ACUSON NX Discuss the 2D Control Panel Keys Explain the Touch Screen 2D Functionality · Demonstrate the 2D Optimization Features = · Locate M-mode Controls Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 68 Turnover Workbook | ACUSON NX3™ Ultrasound System 2D Imaging SIEMENS Healthineers Imaging Screen ACUSON NX3 Ultrasound System Touch Screen Control Panel CUSON NX Restricted ED Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The system powers up in the 2D mode, also known as B-mode (brightness). In 2D, the brightness or darkness of a structure depends on the depth within the body and how much it absorbs sound. To optimize the differences in sound absorption, adjust controls on the: 1. Control panel 2. Soft keys (rotary controls) 3. Touch Screen The imaging screen on the ultrasound system monitor displays the 2D clinical images together with important 2D imaging parameters. Notes 69 Turnover Workbook | ACUSON NX3™ Ultrasound System Imaging Screen SIEMENS Healthineers Imaging Thumbnails Parameters Imaging Area Status Icons Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The imaging screen displays the 2D imaging parameters, the current 2D image and the acquired thumbnail images. The active function of the Select rotary control, Update/View key, trackball, and Escape key displays next to its corresponding status icon at the bottom of the imaging screen. Their function is mode dependent. Notizen 4 Notes 70 Turnover Workbook | ACUSON NX3™ Ultrasound System Imaging Parameters SIEMENS Healthineers' Transducer EC10-5w GYN -3 dB Exam Type THI 7.6 MHZ DR 60 dB Edge 0 2D Settings Persist 3 RIS 4 Map E Tint 2 Frame Rate ASC 3 DICE Low 22 fps Transmit Power Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is an example of the image parameters of an endovaginal study using the EC10-5w transducer. Notizen 5 Notes 71 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives SIEMENS Healthineers · Review the Imaging Screen for 2D ACUSON NX Discuss the 2D Control Panel Keys Explain the Touch Screen 2D Functionality · Demonstrate the 2D Optimization Features = · Locate M-mode Controls Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 72 Turnover Workbook | ACUSON NX3™ Ultrasound System 2D Control Panel Keys SIEMENS Healthineers 2D TGO Depth / Zoom Focus HD Zoom Dual Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Press 2D to activate or return to grayscale imaging. Rotate 2D to change overall gain/brightness. Press TGO™ tissue grayscale optimization technology in B-mode to automatically adjust image brightness for the tissue type being imaged and equalize the overall image gain. Slide DGC pods forwards/backwards to manually adjust gain/brightness at depth. Rotate Depth/Zoom to change the imaging depth. Press Depth/Zoom to activate Zoom ROI (region-of-interest) and then rotate to adjust the ROI size. Press Depth/Zoom again to activate Zoom (magnifies the image) Rotate Focus to move focal zone up/down. Press Focus to activate multiple focal zones. HD Zoom increases the images size, detail resolution and frame rate in a region of interest. Press to activate the HD Zoom ROI. Rotate the Depth/Zoom control to adjust the ROI size and press Depth/Zoom again or HD Zoom to activate. Dual displays two separately acquired images side-by-side. Press Dual to activate and toggle between images. Press 2D to exit. Roll the trackball to perform functions in 2D such as: . Pan the image in Zoom. Adjust the position of the HD Zoom ROI. . Activate Cine in Freeze. . Move the Pointer. Notizen 7 Notes 73 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives SIEMENS Healthineers . Review the Imaging Screen for 2D ACUSON NXE Discuss the 2D Control Panel Keys · Explain the Touch Screen 2D Functionality · Demonstrate the 2D Optimization Features · Locate M-mode Controls Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 74 Turnover Workbook | ACUSON NX3™ Ultrasound System Touch Screen 2D Controls SIEMENS Healthineers 20 2D Imaging Mode Touch Area DTO off ClarifyVE ClarityVE Levels Lvo contrast Split THI Imago Presets Edge Gen 48 Offset 1GO Gain Adv.SeClear LUR Flip Full Stre RUS OTCE UND Flip Modity Map SynAps Clip Capture >> Soft Key Selections Clip Capture >> Mil berts Map 20 FOV Page 1 Page 2 Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is an example of the touch screen controls for the two pages available in 2D. Touch the controls located in the Touch Area to activate. Turn or press the rotary control assigned to the soft key selection. Split activates two simultaneous images in dual format. Select to activate/deactivate. 4B displays four separately acquired images. Select to activate and press Freeze to add each image. Select 2D on the control panel to exit. Offset allows you to scroll the 2D image vertically and/or horizontally. Select Offset, roll the trackball to scroll the image vertically and/or horizontally. DTCE and ASSC/SC are not available in Offset. TGO™ tissue grayscale optimization technology Gain is a user-definable threshold that accommodates different user preferences for gain settings and various room lighting conditions. Full Size maximizes the field of view when the sector size has been decreased. Clip Capture allows you to designate clip capture parameters: capture type (prospective or retrospective), acquisition rate and trigger type Rotate rotates the image 90 degrees clockwise or counterclockwise. Turn the rotary control assigned to the Rotate soft key selection. 2D FOV changes the sector angle for transducers displaying a sector format. Turn the rotary control assigned to the 2D FOV soft key to adjust the angle. Notizen 9 Notes 75 Turnover Workbook | ACUSON NX3™ Ultrasound System DTO™ Dynamic tissue Optimization technology detects and optimizes hyperechoic signals (blooming whites) in real-time to prevent over saturation. L/R (Left/Right) and U/D (Up/Down) Flip changes the orientation of the image. Modify Map displays controls to modify the shape of the current Gray Map. SynAps (Synthetic aperture technology) improves lateral resolution at depth. It is a two pulse technology so Frame Rate is reduced. Notizen 9 Notes 76 Turnover Workbook | ACUSON NX3™ Ultrasound System Objectives SIEMENS Healthineers . Review the Imaging Screen for 2D ACUSON NX3. . Discuss the 2D Control Panel Keys · Explain the Touch Screen 2D Functionality · Demonstrate the 2D Optimization Features = · Locate M-mode Controls Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 77 Turnover Workbook | ACUSON NX3™ Ultrasound System Zoom and HD Zoom SIEMENS Healthineers VF10-5 Masquar OR 54 46 Edge 2 DR 85 ED Persist 3 Persist 2 PUIS 3 Map H Map D Tint 2 Tint 2 ASC 2 ASC 5 TCE Low TCE Med Zoom HD Zoom Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Standard Zoom is available on live, frozen, CINE and dual screen images. Zoom magnifies the image and is a read Zoom. Press Depth/Zoom to activate Zoom ROI and then rotate to adjust the size of the ROI. Press Depth/Zoom again to activate Zoom. When Zoom is activated, the letter "Z" appears at the bottom of the image. Once in Zoom, use the trackball to Pan the image to the desired location. To exit, press the 2D control. HD Zoom Increases the images size, detail resolution and frame rate in a region of interest. It is a write Zoom that is not available in Freeze or CINE. Press HD Zoom to activate the HD Zoom ROI. Rotate the Depth/Zoom control to adjust the ROI size and press Depth/Zoom again or HD Zoom to activate. When HD Zoom is activated, the letters "HD Zoom" will appear at the bottom of the image. To exit, press the 2D control. Notizen 11 Notes 78 Turnover Workbook | ACUSON NX3™ Ultrasound System Dual SIEMENS Healthineers ASCO DTCE Met Conventional Dual Seamless Dual Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Dual displays two separately acquired images side-by-side. Press Dual to activate and toggle between images. The "a" in gold denotes the active side. The system can be configured for conventional dual or seamless dual under Presets>Exam Configuration>Seamless Dual. Conventional dual allows measurements on either the right or left image. Seamless dual allows for measurement across the central line. Press 2D to exit. Notizen 12 Notes 79 Turnover Workbook | ACUSON NX3™ Ultrasound System Tissue Harmonic Imaging (TH) SIEMENS Healthineers CH5-2 Abdomen THI 3.6 MHZ DR 65CD Edge 1 PersistJ Map F Tirt 2 ASC 3 DICE Med 22 fpi THI Listens to harmonic frequency to produce an Increases contrast and lateral resolution mage Reduces noise and clutter Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Tissue Harmonic Image (THI) activates selectable harmonic frequencies to improve contrast and spatial resolution by reducing noise and clutter in the image. The body creates a harmonic signal that is twice the frequency sent into the body by the transducer. For example: If a 2 MHz signal goes into the body, the transducer uses the 4 MHZ signal that returns from the body. Select THI on the touch screen to activate/deactivate. The system displays THI next to the frequency value when it is activated. To change the THI frequency turn the rotary control assigned to the MultiHertz soft key. Notizen 13 Notes 80 Turnover Workbook | ACUSON NX3™ Ultrasound System Image Presets SIEMENS Healthineers 2D Penetration, General and Detail Pen Gen Det Quick image optimization of Image Presets Gen multiple imaging parameters Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Image Presets optimizes multiple image parameter settings for the active exam and transducer. Select Image Presets on the touch screen and then select: . Pen (Penetration) for improved penetration. . Gen (General) for general settings. · Det (Detail) for improved resolution. Select Image Presets again to return to the main menu. Notes 81 Turnover Workbook | ACUSON NX3™ Ultrasound System Advanced SieClear™ Spatial Compounding SIEMENS Healthineers Transducer Steered Image 1 Image 2 Image 3 Off 2 Adv.SieClear Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only SieClear compounding is a receive compounding technique. The images combined are created from the same transmit pulse, but receive two angled beams to produce a compounded image for improved contrast resolution and border detection. SieClear compounding is activated by selecting Adv.SieClear from the touch screen and selecting a setting of "2". Advanced SieClear compounding is a receive spatial compounding technique. The images combined are created from the same transmit pulse, but receive two angled beams to produce a compounded image for improved contrast resolution and border detection. The number of different steering angles (3, 5 or 7) available depends on the transducer and exam. Advanced SieClear compounding is activated by selecting Adv.SieClear from the touch screen and selecting settings of "3, 4 or 5". Selecting a setting of "0" turns both SieClear compounding and Advanced SieClear compounding off. This is an image of an carotid artery using the VF12-4 transducer. The Advanced SieClear compounding is set at "5" as noted on the imaging parameters area on the screen. Note the well- defined intimal medial border and contrast resolution. Notizen 15 Notes 82 Turnover Workbook | ACUSON NX3™ Ultrasound System Dynamic Range SIEMENS Healthineers Enhances contrast resolution Higher setting results in a softer / grayer appearance Lower setting results in a more black / white appearance Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Dynamic Range adjusts how many shades of gray display on the image. A low dynamic range setting increases the image contrast while a high dynamic range decreases the image contrast. This is why the dynamic range selected also changes the contrast resolution. To change the Dynamic Range, turn the rotary control assigned to the DR soft key. The Dynamic Range settings in 2D are transducer-dependent in increments of 5 dB. Dynamic Range is adjustable on a frozen image or during real-time imaging. To adjust, turn the rotary control assigned to the Dynamic Range soft key. This is an example of a complex thyroid nodule using the VF12-4 transducer with a Dynamic Range of 70 dB. Note the contrast resolution between the normal thyroid tissue and the nodule and within the nodule itself. Notizen 16 Notes 83 Turnover Workbook | ACUSON NX3™ Ultrasound System MultiHertz™ Multiple Frequency Imaging SIEMENS Healthineers Adjusts center frequency DR. 68 dM Peralut 3 Mas A ASC ! DICE High Higher frequencies for higher resolution Lower frequencies for improved penetration Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The MultiHertz soft key rotary allows the user to control the MultiHertz imaging functionality of the system to enable the user to improve image resolution (high frequency) or increase penetration (low frequency). 2D or THI, color and spectral Doppler frequencies can be used independently for optimal choice of image resolution, penetration and sensitivity. MultiHertz imaging operation depends on two things: 1. Broad bandwidth transducer element sensitivity to a range of returning frequencies. 2. Digital signal processing to select the frequency bandwidth of interest. Bandwidth is described as a percentage of the center frequency, that the user controls with Multihertz imaging. The MultiHertz soft key adjusts both native and harmonic imaging frequencies. Notizen 17 Notes 84 Turnover Workbook | ACUSON NX3™ Ultrasound System Dynamic TCE™ Tissue Contrast Enhancement Technology SIEMENS Healthineers GYN Enhances tissue contrast THI 6.7 WHE DR 10 ce Edge 2 Persist 1 Tint 3 Reduces speckle 25 1pal Compatible with other technologies Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Dynamic TCE tissue contrast enhancement technology is Siemens proprietary post-processing method for speckle reduction. In general, some tissues have low contrast resolution due to marginal differences in acoustic impedance between soft tissues of the tissue but also due to the production of speckle. Speckle is displayed as a granular pattern formed from interferences of backscattered ultrasound waves which substantially lowers image contrast and obscures image details. It's suppression must be balanced, as it can contain diagnostic information. Dynamic TCE Technology is activated/deactivated by selecting DTCE from the touch screen and selecting settings of Off, Low, Medium or High. Benefits of this technology include: Enhance subtle tissue contrast areas. Compatible with other technologies like Advanced SieClear Spatial compounding, color and power Doppler. This is an example of a uterus using the EC9-4 endocavity transducer. In this example, Dynamic TCE Technology is set in Medium and demonstrates contrast resolution of the uterine fundus, body and cervix and a detailed look at the endometrial lining. In areas where there are more specular reflectors, a higher level of Dynamic TCE technology will emphasize borders and strong reflectors in the image. Notizen 18 Notes 85 Turnover Workbook | ACUSON NX3™ Ultrasound System Clarify™ Vascular Enhancement (VE) Technology SIEMENS Healthineers Reduces artifacts in vessels CHS-2 · Improves vessel wall definition THI 4.4 MHZ Persisa 3 RIS 3 Map D + B-mode Power Doppler = Clarify VE technology Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Clarify VE technology is a Clarify VE technology is a real-time, adaptive, pixel-by-pixel analysis which provides exceptional contrast resolution for clear delineation of vessels. It uniquely utilizes power Doppler flow information to enhance 2D-mode imaging. Clarify VE technology does not change the B-mode image in nonvascular structures, e.g ., within the gallbladder or urinary bladder. Notizen 19 Notes 86 Turnover Workbook | ACUSON NX3™ Ultrasound System Frame Rate SIEMENS Healthineers How many times an image is updated per second VF12-4 C-Vascular 0 dB Impacted by image depth, width and number THI 8.0 MHZ of focal zones DR 60 dB Edge 2 Persist 2 RIS Higher frame rates provide increased Map A Tint 2 temporal resolution ASC 5 DTCE Low 41 fps Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only How often a system updates the image is called "Frame Rate". Temporal resolution is the system's ability to display closely spaced time events and present rapidly moving structures. The Frame Rate determines the temporal resolution and therefore is important when assessing moving interfaces. To obtain a clear image of moving structures, the time taken to acquire the image should be short in comparison to the time which these various structures move. The higher the frame rate the more accurately the movement can be displayed. Decreasing the depth, reducing the number of focal zones and narrowing the image width improves frame rate since the time needed to acquire the image is reduced. This is especially important when imaging moving objects, e.g ., cardiac imaging, fetal heart, venous values or to distinguish peristalsis in the bowel. In this venous valve example, note the frame rate is 41 frames per second. This was achieved with a shallow 4 cm depth. Notizen 20 Notes 87 Turnover Workbook | ACUSON NX3™ Ultrasound System Resolution/Speed (R/S) SIEMENS Healthineers VP12-4 Testici VF12-4 9.4 WH: Testicle 0 dB Edge Persist 3 THI 9.4 MHZ RIS Map E DR 60 dB Edge 1 Persist 3 RIS 4 Map E Tint 2 SC 2 DTCE Med DTO 1 30 fps Balance between image line density and frame rate Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only You can increase or decrease the number of acoustic scan lines per frame for 2D images. Increasing the line density improves image detail and decreases the frame rate. Resolution/Speed (R/S) adjusts the balance between the image line density (resolution) and the frame rate. Select R/S on the touch screen to increase/decrease resolution or speed. Selections in 2D include 0-5. Clinical Benefits include optimization of specific anatomy for the maximum resolution (e.g ., breast or small parts study) or provide a higher frame rate when needed (e.g ., fetal heart or arterial study). The example shows a testicular image using the EC10-5w transducer with a R/S of 4. Notice how it favors resolution. The Frame rate is not affected (30 fps) since this is a superficial organ. The difference in frame rate will be more noticeable in deeper structures. Notizen 21 Notes 88 Turnover Workbook | ACUSON NX3™ Ultrasound System Edge Enhancement and Persistence SIEMENS Healthineers Edge Persist 3 O Edge Persist Edge Persistence Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Edge (Edge Enhancement) distinguishes the contours of a structure during real-time imaging and suppresses changes in brightness across the image to enhance or smooth borders. A sharper image is created by combining adjacent signals. This will show higher contrast and brighter edges of structures. Higher edge settings provide increased border enhancement. Lower settings smooth the edges or boundaries. Select Edge on the touch screen to select a setting. Settings range from 0-3. Persistence provides a visible smoothing effect to the 2D image by maintaining lines of image data for each frame of imaging. It determines the number of images the system combines into the final image. For example, when the persistence is set at 0, the image updates with every sweep of the transducer. A Persistence of 1 results in the averaging of two images, and so on. At higher settings, the number of images averaged is higher, reducing noise and making the image appear smoother. Select Persist on the touch screen to select a setting. Settings range from 0-4 In this example, notice the Persistence is grayed out. Persistence is not available if Advanced SieClear compounding settings are turned on. Reduce the Adv.SieClear control to a SieClear compounding of 2 or 0 (off) to utilize. Notizen 22 Notes 89 Turnover Workbook | ACUSON NX3™ Ultrasound System Maps SIEMENS Healthineers CHE-2 CH$-2 Maderen Abduran DR 65 4D Edge 1 Edge 1 Persist 3 Persist 3 RIS 3 Map H Map F Tirt 2 Tint ASC 3 ASC 3 TCE Med TCE Wed Map H Map F Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Map parameter is used to select a processing curve that assigns echo amplitudes to gray levels. The active Map is depicted by a gray bar, which displays on the right side of the image screen. The gray bar represents the range of gray shades available for the selected Map. The Map control can be activated during real-time imaging or when the system is in freeze. A gray map determines how dark or light you prefer to show each level of white/gray/black based upon the strength of the ultrasound signal. Turn the rotary assigned to the Maps soft key selection to select a gray map. Settings are from A - I (from low to high contrast) and 1-3 (customizable maps). Modify Map: You can redistribute the range of echo amplitudes assigned to the range of available gray shades for selected gray maps during real-time imaging or when the system is in freeze. You can reposition the inflection points within a specific range. The system automatically recalculates the curve and updates the image. Notizen 23 Notes 90 Turnover Workbook | ACUSON NX3™ Ultrasound System Tints SIEMENS Healthineers VF 12-4 VF 12-4 C-Vascular C-Vascular 4 0B HIZO NHE THI 9 4 MHZ DR 63 dh DR 60 dB Edge 2 Edge 2 Persist 2 Persist 2 RIS 4 RIS 4 Map A Map A Tint 2 Tint S ASC 6 DICE Low DICE LOW 39 fps 35 fps Tint 2 Tint 9 Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only You can individually colorize the grayscale 2D image by applying a Tint. A Tint can aid in visualization of subtle differences in tissue. Adding a Tint changes the color of the image by adding multiple levels (0 to 15) of blue, red, yellow, or green to the gray in a gray map. To select a Tint, turn the rotary control assigned to the Tint soft key selection. This is an example of the jugular vein image using the VF12-4 transducer applying Tint 9. Note the spontaneous flow and valve detail. Notizen 24 Notes 91 Turnover Workbook | ACUSON NX3™ Ultrasound System SieScape™ Panoramic Imaging Option SIEMENS Healthineers Apps. SieScape SieScape Cine SieScape Review Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only SieScape Panoramic Imaging allows acquisition and display of grayscale images up to 60 cm in length to a maximum curvature of 360 degrees. Available on curved and linear transducers. Panoramic imaging is a technique where the user moves the transducer along the patient's anatomy and the system blends the multiple images together to form one long image with an extremely wide field of view. This feature uses techniques to compare consecutive images, rotating and stitching them together to form the final image. To access the SieScape Imaging menu, press the Apps key on the keyboard. . Select SieScape to activate. Select Set to begin acquisition and Freeze to stop acquisition. Press Freeze to reactivate acquisition. Use SieScape Review controls after completing the acquisition to size, rotate, pan, Zoom or measure the SieScape image. . You can use the SieScape Cine function to recall single frames for review. . Select Exit to exit SieScape Review. Notizen 25 Notes 92 Turnover Workbook | ACUSON NX3™ Ultrasound System Linear Trapezoid SIEMENS Healthineers Thyroid 12 3 MM: OR 60 08 Persist 3 Map O SC 2 Trapezoid CE Med 23 fps Available on all linear array transducers Increases far field Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Trapezoid angles the outer edges of the 2D image on linear transducers to extend the far-field display. The amount of angle is based on each linear transducers capabilities of maximum steering in turn determined by the pitch and array of the transducer (e.g ., the VF12-4 and VF16-5 transducers increase by 15 degrees in all exams and the VF13-5sp transducer increases by 12 degrees in all exams. The VF10-5 transducer increases by 12 degrees in all exams when configured to FOV1 and FOV2). by 24 degrees in Breast, 20 degrees in CV and 15 degrees in all other exams when configured to To activate/deactivate Trapezoid imaging, select Trapezoid on the touch screen. Some common areas used clinically include: . Thyroid imaging to show large nodule . Testicular imaging for pathology (e.g. hydrocele) . Pediatric imaging when higher frequency is needed . Early OB imaging · Vascular imaging . Appendix Notizen 26 Notes 93 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives . Review the Imaging Screen for 2D ACUSON NX3 · Discuss the 2D Control Panel Keys . Explain the Touch Screen 2D Functionality · Demonstrate the 2D Optimization Features Locate M-mode Controls Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 94 Turnover Workbook | ACUSON NX3™ Ultrasound System M-mode Controls SIEMENS Healthineers RT LUNG M Restricted E) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only M-mode displays a 2D reference image and an M-mode sweep. M-mode allows a graphic display of motion, such as tracing a fetal heart rate or, in the example shown, a lung ultrasound to check for pneumothorax . The cursor or M-line indicates the path used to obtain the M-mode tracing. Anatomy that remains stationary displays as a straight line while curved or peaked lines mirror the moving anatomy. To activate M-mode: . Press M on the control panel to access the 2D image/M-mode sweep on the imaging screen and the M-mode menu on the touch screen. · Roll the trackball to position the M cursor. · Select Full M on the touch screen to enter/exit full screen sweep. . Rotate M to change the overall M-mode gain. . To exit, press the M or 2D control on the control panel. The 2D/M-mode imaging format (1/2 2D, 1/2 trace; 1/3 2D, 2/3 trace; 2/3 2D, 1/3 trace; Side by side) is configurable under the Presets>Exam Configuration>2D/M & 2D/Doppler Display Format menu. Configure the system under Presets>Display>Doppler/M-Mode>Bypass M/D Cursor Display. Uncheck to display the full screen 2D with the M cursor after pressing M. Check to bypass the initial full screen 2D with the M cursor and immediately activate it in the 2D/M-mode sweep format. Notizen 28 Notes 95 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary Review the Imaging Screen for 2D · Discuss the 2D Control Panel Keys · Explain the Touch Screen 2D Functionality Demonstrate the 2D optimization features Locate M-mode Controls Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 96 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Questions Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 97 Turnover Workbook | ACUSON NX3™ Ultrasound System 5. Doppler Optimization SIEMENS . Healthineers System Installation Training Doppler Optimization ACUSON NX3™ Elite Ultrasound System Restricted (@ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 98 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives Review the Imaging Screen for Doppler ACUSON NXE · Discuss the Doppler Control Panel Keys · Demonstrate the Doppler Optimization Features Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 99 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Imaging Parameters - Color Doppler Healthineers VF12-4 Transducer C-Vascular -1 dB 4.0 MHZ 2441 Hz Filter 1 Exam Type Persist 2 RIS 3 SCI DTCE Law Map A Priority Smooth 3 Color Doppler Parameters Flow M 15 fps SC 2 DTCE Low Frame Rate Transmit Power Restricted E) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is an example of the color Doppler parameters of a carotid artery using the VF12-4 transducer. Note the mean velocity scale (PRF) in cm/s and color baseline position on the color bar located on the right side of the image. The data field displays the color Doppler Parameters. The PRF displays in units of Hertz. Notizen 3 Notes 100 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Imaging Parameters - Spectral Doppler Healthineers VF12-4 ---- Transducer C-Vascular 43 dB 4.0 MHZ 4340 Hz Map C Filter 130 Hz Exam Type Update Off TIOF Res DR 55 dB Map D Tint 2 Sweep 2 Spectral Doppler Parameters Gate 1.5 mm TIF Res F Angle 60 15 fps Frame Rate Transmit Power Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is an example of the spectral Doppler parameters of a carotid artery using the VF12-4 transducer. Note the Doppler velocity scale (PRF) in cm/s and Doppler baseline position on the right side of the Doppler spectrum. The data field displays the PW Doppler Parameters. The PRF displays in units of Hertz. Notizen 4 Notes 101 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Objectives Healthineers Review the Imaging Screen for Doppler ACUSON NX . Discuss the Doppler Control Panel Keys · Demonstrate the Doppler Optimization Features Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 102 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Doppler Control Panel Keys Healthineers CW Power Angle Update / Steer Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The primary keys on the control panel are: Press C to enter/exit color Doppler. Rotate C to change overall color Doppler gain. Gain of -20 dB to 20 dB in one decibel increments is available. Press Power to enter/exit power Doppler. Rotate C to change overall power Doppler gain. Gain of - 20 to 20 dB in one decibel increments is available. Press D to activate the Doppler cursor. Press D again to enter PW (pulsed wave) Doppler. Rotate D to adjust overall spectral Doppler gain. Press D or 2D to exit. Gain of 0 dB to 90 dB in one decibel increments is available. Press CW (continuous wave) to activate SCW (steerable continuous wave Doppler) for phased array transducers or the auxiliary CW pencil transducers. Note: For PW and SCW Doppler, configure the system under Presets>Display>Doppler/M- Mode>Bypass M/D Cursor Display. Uncheck the box to display the full-screen 2D with the Doppler Notizen 6 Notes 103 Turnover Workbook | ACUSON NX3™ Ultrasound System cursor after pressing CW. Check the box to bypass the initial full screen 2D with the Doppler cursor and immediately activate the 2D/Doppler split format. During 2D/Doppler, you can use the Update key to toggle a real-time 2D image and a frozen spectrum with a frozen 2D image and real-time spectrum. The Update status at the lower right of the screen indicates the active option. Use the Steer control to toggle the color Doppler ROI and to steer the spectral Doppler cursor right/left. Press Angle to adjust the flow angle from 0º / 60º / 0º , or, rotate Angle to adjust the flow angle by 1º increments. Angle depicts the degree of angle correction for the Doppler spectrum. When you first activate Doppler, the display of the flow angle indicator to the Doppler cursor is exam-dependent. The system also displays the values of angles greater than 1º on the screen. When the angle is 65º or greater, the system highlights the value of the angle in green. Press the Set key to toggle the size and position options for the color Doppler ROI. The trackball status at the lower right of the screen indicates the active option. Press TGO™ Tissue Grayscale Optimization during spectral Doppler to automatically optimize the selected parameter(s). Use the system presets to select the parameter(s) under Presets>Display>Doppler/M-Mode>Doppler Auto Optimization. Parameters that can be automatically optimized include Gain, Dynamic Range, Scale/Baseline. Dual, Zoom and HD Zoom are available in color Doppler. Zoom is available for the 2D reference image in spectral Doppler. Roll the trackball to perform functions in Doppler such as: . Position the color Doppler ROI. . Size the color Doppler ROI. . Position the spectral Doppler cursor. . CINE the Doppler image or spectral Doppler waveform in Freeze. . Position the Pointer. Notizen 6 Notes 104 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives · Review the Imaging Screen for Doppler ACUSON NX3 . Discuss the Doppler Control Panel Keys ·Demonstrate the Doppler Optimization Features Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No Speaker Notes. Notes 105 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Color Doppler - Flow State Healthineers · Low, Medium, High · Quick color Doppler optimization of multiple imaging parameters Flow Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Select the Flow control to quickly optimize the color Doppler flow state without changing multiple controls. Flow L Low (e.g ., renal perfusion, pancreas, small parts ( testicular, thyroid, Breast), ovarian, calf veins, fetal head, placenta) Flow M Medium (e.g ., Liver, splenic vein, portal vein, hepatic veins, peripheral vascular in extremities, OB cord) . Flow H High (e.g ., fetal heart, aorta) As the setting changes, note the change in the image and parameters displayed on the imaging monitor. Select Flow to return to the main color screen. Setting changes vary with transducer and exam. Notizen 8 Notes 106 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Color Doppler - Invert Healthineers 1125 Hz Persist 2 Map A Pristiry Smooth 2 Flaw SC 3 DICE Med P.109% 38 1.12 Invert OFF Invert Invert ON Invert Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Select Invert on the touch screen to reverse the colors depicting flow towards or away from the transducer in the color ROI and the color bar (located on the right side of the image). This is an image of a carotid artery using the VF10-5 transducer. Invert is OFF (white lit touch control) in the image on the left demonstrating that red/yellow colored flow represents flow towards the transducer. The color box for this image displays red/yellow on top and blue/green on the bottom. In the image on the right, the ROI has been steered to the left and Invert has been turned ON (blue lit touch control) demonstrating that red/yellow colored flow represents flow away from the transducer. The color box for this image displays blue/green on top and red on the bottom. Notizen 9 Notes 107 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Color Doppler - Scale and Baseline Testicle Map Priarity STOELEN Higher color Doppler Scale Lower color Doppler Scale Baseline in the middle Baseline in the middle Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Scale adjusts the Pulsed Repetition Frequency (PRF) - the color velocity range or the power frequency range. A higher flow velocity than the selected PRF results in 'wrap around' or aliasing of the signal. To emphasize flow towards or away from the transducer, adjust the Baseline. In these images, the flow towards and away from the transducer is the same as the horizontal black baseline has a central location. If you wanted to highlight flow towards the transducer, in this case red, you would move the baseline down. To highlight flow away from the transducer, in this case blue, move the baseline up. Unlike Scale, Baseline does not change the displayed PRF. As the baseline changes, the system updates the values displayed at both ends of the velocity color scale. Turn the rotary assigned to the Scale soft key selection on the touch screen to adjust the color Doppler Scale. Turn the rotary assigned to the Baseline soft key selection on the touch screen to adjust the color Doppler Baseline. Notizen 10 Notes 108 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Color Doppler - Dual and Split Healthineers CR Tharald WHE THIS E PHE Priosty TVR 2 Svooth DECE Med DICE High Dual Split Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Dual displays two separately acquired images side-by-side and can be activated/deactivated in color Doppler imaging. Press Dual on the control panel to activate and toggle between images. The "a" in gold denotes the active side. The system can be configured for conventional dual or seamless dual under Presets>Exam Configuration>Seamless Dual. Conventional dual allows measurements on either the right or left image. Seamless dual allows for measurement across the central line. Press 2D to exit. Note: You must enter color Doppler before selecting Dual. Split displays the same image side-by-side. It is often used to compare the 2D-mode next to the color Doppler mode for an image. Note: Select Split in 2D mode first and then press C on the control panel to activate Split with color Doppler. The image on the left displays color flow in a thyroid nodule in both the transverse and sagittal planes. The image on the right displays color flow in a fetal liver and its underlying grayscale information. Notizen 11 Notes 109 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Color Doppler - Display a Display ON Display Display OFF Display Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Select Display on the touch screen to activate/deactivate the color or power Doppler display. Use this parameter to show 2D anatomy in the color ROI for real-time and frozen images. This is an image of a carotid artery using the VF10-5 transducer. Display is ON (blue lit control) in the image on the left. In the image on the right, Display has been turned OFF (white lit control) demonstrating the 2D display of the intimal medial border of the distal common carotid artery. Notizen 12 Notes 110 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Color Doppler - Maps Color Doppler Velocity Maps ---- Power Doppler Maps ....... Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Color Doppler Velocity Map assign color shades to the mean Doppler frequency shift and direction of blood flow relative to the transducer. Lower velocities display the darker shades of color (more saturated). Higher velocities display the brighter shades of color (less saturated). Color Maps have two distinct color selections assigned above and below the color baseline to demonstrate direction of flow. Flow towards the transducer is the top color and flow away from the transducer is the bottom color. The image of the sagittal jugular vein on the left displays a traditional red and blue color map. The second image displays a Velocity Variance Map which demonstrate the variance (range of flow) horizontally and the mean velocity vertically. In this map, the variance displays as green. Use Velocity Variance maps in Cardiac, and vascular studies in areas of stenosis or turbulence. Nine Maps are available - seven velocity Maps (A-G) and two velocity variance Maps (H,I). Turn the rotary assigned to the Map soft key selection on the touch screen to select the desired color Doppler Velocity Map. Power Doppler Map assigns a range of colors to the power Doppler ROI. It is based on flow amplitude. The active map is depicted by the power Doppler bar, which displays on the right side of the image screen. The bar represents the range of color shades available for the selected map. Power Doppler maps indicate stronger signals in brighter colors and weaker signals in dimmer colors, according to flow amplitude. Power Doppler demonstrates less angle dependence, no velocity information. The map displayed on the left is Map A, an orange to yellow map. The map displayed on the right is Map G, a red to yellow map with the background turned on. Background adds or Notizen 13 Notes 111 Turnover Workbook | ACUSON NX3™ Ultrasound System removes a background enhancement of solid color. The solid background color changes, depending on the power Doppler map selected. Turn the rotary assigned to the Map soft key selection on the touch screen to select the desired color power Doppler Map. There are eight power Doppler Maps and settings range from A-H. The current setting is displayed in the imaging parameters on the upper left of the screen. Notizen 13 Notes 112 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Spectral Doppler - Display Formats and Update Styles Esami Configuration Exam PVascular Etan Ointigaston Autorwic Freeze Response User Defined Exan List AsRomac Figare Response Test Annofalos Sheer Angie TypelvF 195 0r) M & R Configuración * FOV.1 FONE jess Ette Fthe Detaal Dopoler Ubdies Style 19920-12 tare ‹ Seer Calor inven 201vDLV D.LY20-15 Cip Captae Auto invert of Color and Sperbure Unide Ser with Cumser Anche Aux Signal Depisy D-4D Defina Selecson 6 40 Cancel Display Formats Update Styles Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Display Format and Update Style for spectral Doppler can be configured in Presets>Exam Configuration. The screen shots shown here are for a Cerebral Vascular exam but the selections are the same across all exams. The Display Format selections are: . 1/2 2D / 1/2 Doppler 1/3 2D / 2/3 Doppler 2/3 2D / 1/3 Doppler Side by Side The Update Style selections are: . 2D-Frz / D-Lv = 2D reference image is frozen and the Doppler spectrum is live. 2D-Lv / D-Lv = triplex, both the 2D reference image and Doppler spectrum are live. D-Lv / 2D-1s = the Doppler spectrum is live and the 2D reference image updates every second. D-Lv / 2D-2s = the Doppler spectrum is live and the 2D reference image updates every 2 seconds. D-Lv / 2D-4s = the Doppler spectrum is live and the 2D reference image updates every 4 seconds. D-Lv / 2D-8s = the Doppler spectrum is live and the 2D reference image updates every 8 seconds. D-Lv / 2D-EOS = the Doppler spectrum is live and the 2D reference image updates at the end of the sweep. In cases where the user does not want to go back and forth using the update key, the auto updates are useful. Notizen 14 Notes 113 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Spectral Doppler - Cursor Het 117 Hz Update Off TIF Rss Angie 80 Bypass M/D Cursor is Unchecked Bypass M/D Cursor is Checked Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To access spectral Doppler, press D on the Control Panel. Note: Configure the system under Presets>Display>Doppler/M-Mode>Bypass M/D Cursor Display. Uncheck the box to display the full-screen 2D with the Doppler cursor after pressing D. Check the box to bypass the initial full screen 2D with the Doppler cursor and immediately activate the 2D/Doppler split format. Notizen 15 Notes 114 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Spectral Doppler - Angle 4338 He Fier 142 Hz Modale Ort Update Off Thet: 3 Mup H step 2 Tiv 4 p FHR = 1478pm Zero degree angle 45 degree angle Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only When acquiring Doppler, the best angle is 0º for the best Doppler shift. Many blood vessels are parallel to the skin and a zero degree angle is not obtainable. Depending on the exam, criteria of acceptable angles are published. Place the angle parallel to the flow. The system displays the angle on in the imaging parameters on the upper left of the screen. In the image on the left of the fetal heart using the CH5-2 transducer, the angle is at 0º . In the image on the right of the main renal artery using the CH5-2 transducer, the angle is 46º The system highlights the angle when above 60 degrees. The angle accuracy is critical when exact velocity measurements are needed. To change the angle, press the Angle rotary located on the control panel to angle between 60/ 0/ 60º . For degree increment changes, rotate the Angle rotary on the Control Panel. Notizen 16 Notes 115 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Spectral Doppler - PW Doppler Gate Healthineers 4883 Hs Fiber 145 Htz Map C Gate 2.0 mm Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The gate (sample gate) placement determines the PW Doppler sample. The width or size of the gate determines the sampling area. Touch Gate on the touch screen to open the slider. Slide the circle to the right or left (or slide the arrows) to increase or decrease the gate size. Gate settings are transducer dependent and display in the imaging parameters on the upper left of the screen. Notizen 17 Notes 116 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Spectral Doppler - Scale and Baseline W14 1843 He 1125 Hz de 14 Ha Update Ort Map D Swsep 7 TIF Fes P TIF RAS F Angie 80 Angie 00 13 tue Scale too low Baseline too high Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Scale adjusts the Pulsed Repetition Frequency (PRF) - the spectral Doppler frequency range. The PRF is dependent on the transmit frequency and the depth of the Doppler gate. Turn the rotary assigned to the Scale soft key selection on the touch screen to adjust the spectral Doppler Scale. Baseline shifts the absolute perspective (zero velocity) for spectral Doppler mode. When the baseline position has been changed, the scrolling spectrum restarts at the new position. On-screen frequency and velocity scales also update. Turn the rotary assigned to the Baseline soft key selection on the touch screen to adjust the spectral Doppler Baseline. The image on the left displays the scale too low and the spectral Doppler signal is wrapping around or aliasing. The image on the right displays the baseline too high and the spectral Doppler signal is wrapping around or aliasing. Notizen 18 Notes 117 Turnover Workbook | ACUSON NX3™ Ultrasound System Spectral Doppler - TGO™ Tissue Grayscale Optimization SIEMENS Technology Healthineers Automatic spectral Doppler optimization . Scale · Baseline · Gain · Dynamic Range TGO Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Press TGO™ Tissue Grayscale Optimization Technology during spectral Doppler to automatically optimize the selected parameter(s). Press TGO technology twice to deactivate the feature. Use the system presets to select the parameter(s) under Presets>Display>Doppler/M- Mode>Doppler Auto Optimization. Parameters that can be automatically optimized include Gain, Dynamic Range, Scale, Baseline. Notizen 19 Notes 118 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Spectral Doppler - Map and Tint C Ped Abd 3255 HE Update Off Tint Gate 2.5 mm TH Res F Angle E Map G Tint 8 Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Spectral Doppler Maps select a processing curve that assigns echo amplitudes to the gray shades in the Doppler spectrum. Turn the rotary assigned to the Map soft key selection on the touch screen to select the desired spectral Doppler Map. Settings are A-H from low to high contrast and display in the imaging parameters on the upper left of the screen. Spectral Doppler Tints colorize the Doppler spectrum. Turn the rotary assigned to the Tint soft key selection on the touch screen to select the desired spectral Doppler Tint. Settings are from 0-11 and display in the imaging parameters on the upper left of the screen. Adding a Tint may assist in measurements and spectral evaluation. Notizen 20 Notes 119 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Spectral Doppler - Sweep Speed 4.8 MME 1125 Hz 3135 Ha Filter 14 H3 Piter 34 Ha Update Off Update Ort Map D TP Hes P TIF Res F Anche ÉE " Angie 50 + Sweep Speed 1 = 18 mm/s Sweep Speed 8 = 143 mm/s Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Sweep Speed adjusts the scrolling speed of the Doppler spectrum in mm/second. Select Sweep on the touch screen to display the Sweep Speed setting selections. The choices on the system are: NTSC (National Television System Committee) 1, 2, 4, 6, 8 and display in the imaging parameters on the upper left of the screen. PAL (Phase Alternating Line) 1, 2, 5, 7, 8 These numbers correspond to values 18, 36, 53, 71, 89, 107, 125, 143 mm/sec and display on the lower right of the screen. Demonstrate arrhythmias, venous reflux or any exam needing multiple cardiac cycles using lower sweep speed settings. Measure time intervals and early fetal hearts using faster sweep speed settings. Notizen 21 Notes 120 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Spectral Doppler - Auto Stats P.Vascular 4.0 Mitz 4143 Ha Per 123 Htz Update Ort CH 60 48 DR 55 an Ors 1m TIF Res F TIF Ass Angie st Angie 80 PI = 1.32 &D = 3.15 SD - 100.00 FO = 25.3 crus Think # 43.2 cmis TArn - 24.0 cmils P 199% Above the Baseline Above and Below the Baseline Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Auto Stats (statistics) function automatically traces the spectral Doppler waveform and records several measurements depending on the selected transducer. You can use the Auto Stats function on a real-time pulsed wave Doppler spectrum. To activate the Auto Stats function: 1. Press D to activate 2D-mode with Doppler. 2. Select Auto Stat on the touch screen. The system displays a graphical trace to indicate mean (yellow) and maximum (blue) velocities or frequencies. . Blw to display trace below the baseline Abv to display trace above the baseline . Both to display trace both above and below the baseline . Off to remove the trace Values of PI, RI, SD, PS, ED, TAmx, and TAmn are displayed. Notizen 22 Notes 121 Turnover Workbook | ACUSON NX3™ Ultrasound System 3. Press FREEZE to display the latest measurement values. To adjust the sensitivity of the automatically traced Doppler spectrum: 1. Select Auto Stat. 2. Select Sensitivity (settings are 1-5) on the touch screen. Measurements populate to the report once entered into the measurement package. Notizen 22 Notes 122 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary · Review the Imaging Screen for Doppler · Discuss the Doppler Control Panel Keys Demonstrate the Doppler Optimization Features Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 123 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Questions Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 124 Turnover Workbook | ACUSON NX3™ Ultrasound System 6. Measurements and Reports SIEMENS. Healthineers System Installation Training Measurements and Reports ACUSON NX3™ Ultrasound System Restricted (!) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 125 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives Explain Access and Screen Information ACUSON NXE Describe Types of Measurements Review Reports Customize Measurements and Reports Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 126 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Accessing Measurements and Reports Healthineers Report Calipe Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The measurement function is arranged by exam type and is available for use with all exam types. All exam types support the following measurement features: S All general measurements and calculations S Customizable summary feature S Exam-specific patient report $ User-defined anatomy assessment selections Access Measurements by pressing the "Caliper" key on the right side of the trackball. Measurements are available during all examinations on real-time, frozen, and Cine images. Note: Images saved can be recalled for measurements after the examination ends. Access the Report from the Workflow controls on the top left of the control panel. When pressed, the Report key shortcuts to the Report page where the worksheet and summary is accessed. Notizen 3 Notes 127 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Image and Touch Screen Display Healthineers Distance Trace Lenge Struin Ratio Elipse shaduw CCA Pies CCAME CCA Diit ICATTOx ICA Mid ICA DE ECA MDA On VA Report UDA Sice MDA Position Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only After activation of the Caliper key: - Measurement Menu is displayed on the Imaging screen for the active application with predefined measurement labels. Not all Exam types have pre-defined labels. - The report and Summary is accessed here. The Touch Screen displays the measurement types available for the specific mode and provides manual adjustment to the Measurement Display Area (MDA) Size and position. - The caliper display is set up in the Presets Menu / M&R Configuration / General Configuration to default to the Center (as shown here) or to Menu or Depth. - In addition, this menu allows the selection of the caliper size and pattern and default for the display area. Notizen 4 Notes 128 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Measurement Labels Application Thyroid Rt Lobe Lt Lobe Isthmus NOD 1 Thyroid Labels NOD 2 NOD 1 NOD 3 TRV NOD 4 NOD 5 V AP NOD 6 ¥ SAG NOD 7 Report Measurement planes NOD B Work Sheet Summary NOD 10 Report, Worksheet and NOD 11 NOD 12 Summary Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Measurement label display area is divided into sections. The Application is highlighted in blue. Depending on the application, the specific labels are list below. Once a measurement label is selected, the measurement planes are displayed. Access to the report and worksheet is available. These can be edited. The Summary provides the final report, where images, recommendations, physician signature and text summary can be added. Notizen 5 Notes 129 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers * Objectives Explain Access and Screen information CUSON NX3 Describe Types of Measurements Review Reports . Customize Measurements and Reports = Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 130 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS . Healthineers Measurement Types Types of Measurements 2D · Doppler M-mode Compound measurements Exam-specific measurements Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only There are specific measurements for 2D, M-mode and Doppler and they vary based on Exam Type. Compound measurements require multiple measurements on one image or multiple images with measurements (e.g. Volume, flow volume and % stenosis). They are part of the 2D and Doppler measurement packages and are exam specific. Notizen 7 Notes 131 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. 2D Healthineers 20 Strain Hatio Ellipse Shadow MDA On Work Shast MODA Siee MDA Position Touch Screen Imaging Screen Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Touch Screen displays the generic types of measurements as shown above. The default type is customizable in the Preset Menu / M&R Configuration / Measurement method / 2D Mode for each exam type. The display and order of the display on the Touch Screen can also be customized there. Depending on the measurement, up to 8 caliper sets can be displayed on the image at one time. The exam type is displayed on the left side of the imaging screen. For some measurement packages, multiple pages are available. In those cases, the Report and Summary may not be displayed until the last page of measurements. The Measure caliper pattern is numbered for each caliper set. A (+ or *) is available as the pattern type. This is customized in the Preset Menu / M&R Configuration / General Configuration. Notizen 8 Notes 132 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers M-mode P4-2 Carrias THI F 3.6 Mitz DR 81 do PUIS Mip G Tire MDA On MDA San MIDA Position Touch Screen Imaging Screen Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Touch Screen displays the generic types of measurements. The default is customizable in the Preset Menu / M&R Configuration / Measurement method / M-mode for each exam type. To measure heart rate, select Heart Rate from the Touch Screen. Press the Set key and place the first cursor. Press the Set key again to place the second cursor. Press the set key to display the Heart Rate. If additional cardiac measurements are needed, use the predefined labels on the left side of the image display. Notizen 9 Notes 133 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers Doppler PW Acceleration Velocity Ratio O 5.2 RI Flow Volume CCA Frak OCK Dit --- ICA Du MDA On MDA Siee MDA Position Touch Screen Imaging Screen Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Touch Screen displays the generic types of measurements and the image screen displays the abeled measurements when available. The default is customizable in the Preset Menu / M&R Configuration / Measurement method / Doppler for each exam type. In this example, we are scanning the Subclavian artery. Although a predefined label measurement is not displayed, a user-defined measurement can be created in the preset menu. We will discuss this in the workshop Notizen 10 Notes 134 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Measurement Labels Exam Types No Pre-defined labels No User-defined labels Abdomen Urology Abdomen Thyroid C-Vascular OB Venous Urology P-Vascular Early OB MSK EM Gynecology TCD Sup MSK Fetal Echo Venous MSK Breast Orthopedic Sup MSK Cardiac Testicle Penile Emergency Med (EM) . Penile Neo Head TCD Breast Renal Small Parts Testicle Ped Echo Pelvic Floor Neo Head Ped Abd Pediatric Small Parts . Pelvic Floor Orthopedic Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The column on the left shows all the default exam types available. The column in the center are the exams that do not have pre-defined measurement labels. Some of them have the ability to add user-defined labels. The number varies based on exam. User-defined labels are customized in the Preset Menu / M&R Configuration / User-defined labels. The column on the right show the exams that do not allow user-defined labels. These all have pre- defined measurement labels. Notizen 11 Notes 135 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Exam Specific Measurements Healthineers ....... C-Vrirsiar CCA Proa CCA Del ICAPISE VICAMI CCA Report Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Once caliper is activated, the Exam specific list will populate on the left slide of the imaging screen. If there are no pre-defined labels, only the Exam type, report and summary is displayed. The left image is the C-Vascular Exam and the right is the Thyroid package. Notice that report and summary is not displayed on the right image. This package has more than one page. Once you select a measurement to take, it will be displayed. Notizen 12 Notes 136 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers User-defined Labels Abdomen THI 3.5 MHZ DR 19 dB Edge Persist 3 Mas? ASC 3 DICE Med Acdamen Liver SAG AO TRY AO RSAG KID RTRV KID ALTRYKIO LSAG KID CB WALL RTRV KID = 33.6mm CAD Report Summary Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only For some exam types, there are no pre-defined labels. User-defined labels are added in the Preset menu / M&R Configuration / User-defined labels. A label may only have 8 characters including spaces. The number of labels available vary by exam. In this example of Abdomen, 20 distance measure labels are available. Notizen 13 Notes 137 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives · Explain Access and Screen information ACUSON NX3. · Describe Types of Measurements Review Reports · Customize Measurements and Reports = Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 138 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Reports Standard Description | Carty Deserption | Deptasien Profis Rt Lobe THY Fetal Heart Modae Facial Profile Daphagm 4Ch heart OVOT Lateral Vostricies LE Late LVOT Chateld Card Inserten Posterior Fossa Ductal Arch Cerebellum Abdominal Wall Mathel Feld I Kidney Fetal Posten L' Hidser Placenta Location Previa L-Spine Bowel Pazem taerom 4 Extremises Cardiac Rhythmn LarkinFeet Delete All Delete Line Delete Cell Send Report Link Pses Sete Report Nest Werk Sheet Graph Worksheet Description Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is an example of the worksheet page in the Thyroid exam and a descriptor page in the OB Calculations. As measurements are entered, the data is added. Up to five of each measurement can be completed. The descriptor pages are customizable in the Preset / M&R Configuration. Notizen 16 Notes 139 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary Image Letter Header General Hospital Patent Data Exam Specific Dain Result 80 Labale CCAMe 424 48 25 ICA Prox 1 07 258 ICA Dist Let Report Images Description Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Access the Summary page on the Touch Screen or Image screen. The system generates a summary and allows the insertion of up to 20 images. Customized comments, site logo and name, recommendations and physician signature can be added. To add the site logo, place it on the USB device and upload. These are customized in the Preset Menu / M&R Configuration and Summary. The display fields and header names are also customized in the Presets Menu / Summary. Notizen 17 Notes 140 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Exam Specific Measurements M & R Configuration Heart Rate Tool Number of Heart Cycles for Heart Rate Measurement and Report Preset Report Dala Auto Store C-Vascular nt Method >> C-Vascular Measurement Order >> Report User Defined Label >> User-Defined Formmila >> Comments Library >> Recurrenendations Library >> General Configuration>> Anatomy Assessment >> Save J Cancer Report Presets Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Report is automatically stored as a thumbnail when Report Data Auto Store is selected in the Preset Menu / M&R Configuration with the images and measurements. In review, select the Pencil icon on the top left of the display screen and the report will launch. The report can be edited, and a Summary may be added. Notizen 18 Notes 141 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Reports Report Summary Summary Expert to USB Print < Prev Next > Return Exit Report Touch Screen Summary Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only When in Measurement the Touch Screen allows access to the report and Summary. Depending on the Exam type, additional fields may populate. When in the Summary page, the user can print to a PC printer or export the Summary in a pdf format to the USB by selecting "Export to USB" on the Touch Screen. Notizen 19 Notes 142 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives · Explain Access and Screen Information CUSON NX3 · Describe Types of Measurements . Review Reports Customize Measurements and Reports Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 143 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Customize Heart Rate Tool Number of Heart Cycles for Heart Rate THI 4 4 MHa OR co dn Measurement and Report Preset Persist 3 F. Report Data ALzo Store Mup Ht THIS Common Preset for OB & Early OB DICE Hin Measurement Method >> Display ten >> 27 tak Customize Keys >> User-Defined Label>> tem & Reference Selection >> User-Defined EFW Formula >> Comments Library >> User-Defined MenstrualAge >> Recommendations Library >> User Defined Growth Analysis >> General Configuration >> User-Defined Rato Formula >> Grouch Analysis Graphs >> Anatomy Assessment >> AC - 208.1mm 30wed Save Cancel Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only There is a lot of customization that is available for Measurements and Reports and the choices vary by exam type. We will explore some of the choices in the workshop, but for a complete understanding of all the options, please review each screen and the owners manual. Notizen 21 Notes 144 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Customize Summary Summary Summary Summary Page 1 | Summary Page 2) Summary Page 1 Summary Page 2 Site Information Section Heading Logo Letter Header Letter Header Fort Patient Data Patierg Dma Text 2 Font Exam Specific Data Exam Specific Data Result Resa Load Delete Fort Graphs Graphs Display Items for Summary mage Image Report Title Summary * On Sammary Recommendations Recommendations Image Signature Signature Summary * On Signature Reference Values Recommendations * On Display Adul Cardiac Reference Values Sigmafre * On Save Cancel Sem Cancel Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Summary has two pages for customization. Summary page 1: - Add logo via USB device Three lines for customer name and address (Font adjustable) - Display items on Summary Summary Page 2: Header name customization - Add physician signature Note: the logo must be outside a folder when stored on the USB device. Notizen 22 Notes 145 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Knowledge Check Why did I not see the user-define labels I created? Answer: After creating the labels, go to Measurement Order and Add. Can I edit measurements directly in the Summary? Answer: No. You can edit in the report and then create another Summary. Where do I go to add the customer logo to the Summary report? Answer: Presets/M&R Configuration/Summary Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This slide is animated. Use these questions to check that your learners understand the presented material. Notes 146 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary · Explain Access and Screen Information · Describe Types of Measurements Review Reports . Customize Measurements and Reports Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only We have completed the Measurement and Reports presentation. You should be able to: Review objectives Notizen 24 Notes 147 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Questions Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No Notes Notizen 25 Notes 148 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Measurement Display Area V1 8 61.4cm/s Freq1 = 2.13KHz V1 . 51.8cm/s Freqt = 1.79hHE PG1 = 1.5mmHg PC1 - 1.1mmHg V2= 17.3cm/s Vz = 16.3cm/s Freqz = 0.60KHz Freqz = 0.63kHz PGE = 0.1mmHg PGz = 0.1mmHg Vo = 0.0cm/s Frego = 0.00KHz PG3 - 0.Cmmi-g Labele PS ED ICA Prox 1.68 0.72 3.54 62.8cm/s 17.7cm/s 25,6 Ratio ICA/CCA($) 0.65 ICA/CCA(D) 0.72 ECAME 1.72 17.3cm/ CCA Dist 73.4cm/s 18.2cm/s Restricted E) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Measurements are displayed in four areas of the display screen. The display area is changed manually on the Touch Screen and the default is set by Exam type in the Preset Menu / M&R configuration / General Configuration. There are also three sizes of the measurement display. The size is changed manually at the Touch Screen or set as a default in the Preset Menu / General 2 / Measurement Display Size. Note: If multiple measurements are displayed, move the MDA position where they are not in the image or spectral tracing. To change the display area manually, press the MDA position soft key under the Touch Screen and rotate to the desired area. Notizen 26 Notes 149 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers 2D Distance Measurement an THE3 1 MHZ DR 65 do Edge 1 Persice 3 Tink 2 ASC 3 OTCE Med 1 = 33.0mm 02 = 33.5mm 00000 P 16016 MI 1.24 Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Complete a Distance Measurement Press the Caliper key on the Keyboard. - Select distance on the Touch Screen. - Roll the trackball to position the first caliper and press the Set key to anchor. - Press Set again to add the remaining calipers. - Press Set twice to complete the measurement. Edit Measurements Press Update on the Control Panel to activate calipers and cycle between active calipers. Press Select Next on the Touch Screen to cycle between caliper sets and reposition. Press Set to anchor caliper. Delete Measurement Press Delete All on the Touch Screen to delete all measurements. Press Escape on the Control Panel (Home Base) to remove one measurement at a time. Notizen 27 Notes 150 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers 2D Distance Measurement Thyroid Thyroid 2 dB THI 9 4 MHZ DR 65 49 DR 65 dB Edps 1 Edge 1 Persist 3 Persist 3 Map Mas ASO ASC ! OTCE MOS DTCE Ned 021 - 54pm A1 - 0.44cmp A1 - 0.45CEP Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only There are other 2D measurements available including" - Trace (manual) (e.g. irregular nodules) - Trace length (e.g. measuring cervix length) - Ellipse (e.g. OB Head and Abdominal circumference) - Angle (Acute Angle) (e.g. OB facial angle and pediatric Hip Angle) - Note: The Hip angle measurement is in the Orthopedic Exam. Once the measurement is completed, the Sonometer is displayed on the image screen. This is customizable in the Preset Menu / M&R Configuration / Orthopedic exam / Measurement Display. 2D Compound measurements requiring multiple images - Volume (e.g. bladder volume) - A/B Ratio (e.g. 2D vessel) - % stenosis (e.g. C-vascular exam for ICA stenosis) Notizen 28 Notes 151 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Doppler Measurement Healthineers VP13-4 C-Viseuler Fier 120 ME .................. UpEats ON Mas D Gate 10am TIF Mes F Angle 83 PS Pl x 1,32 73.0cm/s ED 22.4cm/s PS - 81.5 cm/s ED = 25.9 cris TAstr = 42.2 cmla Then # 24.9 crois Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only There are different types of Doppler Measurements typed. It may require a single placement of a caliper for a Velocity measurement or two calipers for a Resistive / Pulsitility Index. Auto Stats are also available that automatically trace the entire spectrum and provide many measurements. To take an Doppler measurement - Acquire an Doppler trace and press the Freeze key. - Select you measurement type on the Touch Screen. - Roll the trackball to place the first caliper. Press the Set key to anchor. - Depending on the type of measurement, an additional caliper may need to be anchored. - To enter into the report package, select the label from the left side of the screen. The user can label then measure or measure then label depending on their preference. Notizen 29 Notes 152 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS M-mode Measurement Healthineers Carslas DR 54 d! Edge ! Map E Oi Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To take an M-mode measurement - Acquire an M-mode trace and press the Freeze key. - Select you measurement type e.g. (HR) heart rate) on the Touch Screen. - Roll the trackball to measure from beat to beat. - Press the Set key to anchor. - In this example, the HR is displayed in the measured results. Notizen 30 Notes 153 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Reports Data fiata Deserpte indication Lan 1 80 0175 17 a OM 320 1.72 11.75 403 734 072 151 1 72 CAME 585 ICADIE 0.43 I.M 0 74 LM CANOCANON Sind Recen Ream Data Description Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The measurement package also offer an editable report. Depending on the Exam Type, they may have a Report with Data and Description and the Summary as shown in the C-Vascular exam. The worksheet or data displays the individual results of the measurements and is editable. The description page is available for some exams, and appears differently based on the Exam type. Notizen 31 Notes 154 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers * Customization M&R >> Customize Keys: Thyroid MAR >> Customize Keys: Thyroid 2D-Mode ] M Mode Doppler | 20-Mode ( st Mode | Dapeter] Velocity verboty wton Velpoty Rato Distance Into ce Dist 11 Manual Atreleraton HR Voume Elipse low Voune Velocity Rato Disk Tim Did Radio D-Flow Val Areo Ratio A Flow Vol D-Fine Vol MDA Position A Flow Vol Summary Stan Hatio Urso GA try CRUIUPD MDA Position Surunary QueGraph Auts OB Shadow Delate Page: Detaist . Therod Previous Detail . Thyroid Previous Doppler 2D Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Measurement display on the Touch Screen is customizable in the Presets Menu / M&R configuration / Customize keys for each mode. This is an example of the 2D and Doppler. Notizen 32 Notes 155 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Reports Report WorkSheet Summary Report WorkSheet Graph Summary Data Anatomy Data Standard Descricion Early Biophysical escription Factory Setting User Setting Create Setting Fetus( A) Fetus(e) Fetus(C) Fetus(D) Prov Next > Recur Next › Autumn Report Touch Screen OB Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only In these Exam examples, there is a worksheet as well as the Data / Anatomy. (e.g. OB, Gyn, Thyroid) available. Access these on the image screen or the Touch Screen. In OB, the user has a larger selection of options available. They can customize the descriptions for Standard descriptions and access them easily. Notizen 33 Notes 156 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Customize M&R >> User Defined Label: Abdomen M&R >> Measurement Order: Abdomen* 2D-Mode User-Defined Measurement Label Mode 12D-Mode User-Defined 16 Label Name Distance Selectable Label Measurement Order Measurement Method Distance Vont Liver TRY AD Von RSAG HOD M-Mode User-Defined Measurement Label RIRV ND LTRV HD User-Defined 1 Label Name LSAG KD < Delete Measurement Method Distance Move Up PANCH Move Down Doppler User-Defined Measurement Label User-Defined ! Label Name Measurement Method Velocity Save Previous Save Previous Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To add user defined measurement labels: - Select Presets / M&R configuration. - Select the exam type. - Type in the name. - Use the drop down to go to the next user-defined label. A prompt will ask you if you want to save. Next: - Select Previous - Go to the Measurement Order screen. - The labels appear on the left side in the Selectable Label column. - Add each one to the right and move up/down to the desired location. - Press Save. Press Presets on the Control Panel to exit the menu. The measurements labels are displayed when caliper is selected. Notizen 34 Notes 157 Turnover Workbook | ACUSON NX3™ Ultrasound System 7. Text Annotations, Pictogram and Arrow SIEMENS Healthineers System Installation Training Text Annotations, Pictogram and Arrow ACUSON NX3™ Ultrasound System Restricted (!) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 158 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives Discuss Features CUSON NX3 . Perform Text Functionality and Customization . Review Pictogram Functionality and Customization = . Describe Arrow Functionality Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. 2 Notes 159 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Annotation VF12-4 C-Vascular prox 5 dB THI 8.0 MHZ Right Trans DR 60 dB Left Trans Edge 2 Persist 2 RIS 4 Map F Tint 10 ASC 5 DTCE Low 48 fps K K V distal Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The ACUSON NX3 system with the Touch Screen annotations makes this task easy for the user. So let's get started. 3 Notes 160 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Accessing Annotations, Pictograms and Arrows Delete Hide Clear INSI Word Text Screen OVR Text Pictogram Arrow Pictogram T a O O | + N -- ----- O O - - - K L . Keyboard Touch Screen Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Access Annotations, Pictograms and Arrows by pressing the "T" for Text, "Pictogram" key "Arrow" on the alphanumeric keyboard. Text can also be programmed on the User-defined keys in the Preset Menu. You can use any of these methods to annotate an image: - Direct text entry using the keyboard - Predefined labels for positions and anatomical structures - Arrow keys - Pictograms of anatomical structures The Touch Screen displays the text labels and pictograms for the selected exam type. We will discuss each separately. 4 Notes 161 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Imaging Screen Display Right Sagittal GB 2.7 Nits DR 86 dB Edpe 2 Persis1 3 File 1 Perdet 3 Map ASC 3 DICE Mes Sebodi 3 Flow N OTCE Mex -- .... Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Entered text displays at the "Set Home" location. The text can be moved to any location with the imaging area (highlighted on the left image.) As a note, when moving text, only one word at a time is movable. The configuration menu allows programming of the Pictogram display location (Presets / General 2 / Common Mode). Select either top right or bottom right of the monitor. The right image shows the pictogram in the bottom right of the image. The arrow (not displayed) can be placed anywhere in the imaging screen. 5 Notes 162 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Text Touch Screen Annotation Pictogram Arrow Mode indicators Right Sagittal Pancreas Trannene Duct Head Body Tail Text A, Text B, Library, User- Superior Comonal Rt Kidney Lt Kidney Spleen Portal V. defined Inferior Proximal Hepatic V. Hepatic A. Yris Aorta Mid IVC best test2 Distal Text Functions Home Position Set Home Position Hidde Text Clear Screen Delete Line Delete Word Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Touch Screen is laid out into three separate areas. The Mode indicators are Annotation /Pictogram/ Arrow and the menu defaults to the Text tab. (identified in blue). Press the selection on the Touch Screen to move between modes. -The "Text" tab varies with exam and has three sections: Text A: Imaging Views Text B: Positional Library and User-defined: List of predefined anatomy. User-defined displays after the pre-defined library as seen in the example (test, test2,test3.) The User-defined are customizable by name and position on the Touch Screen in the Presets Text Annotation. - The Text Functions allow the user to set and move to the Home position, Hide and Delete text by Clearing the screen and Deleting a line or a word. 6 Notes 163 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Pictogram Touch Screen Annotation Pictogram Arrow Mode indicator Library of Pictograms Pictogram Functions Delete Soft Key Function Flotante Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Pictograms are on-screen graphics indicating an anatomical structure. The transducer orientation also displays. One pictogram displays on an image. In Dual-mode and 4B-mode, you can display one pictogram for each image. Selecting the Mode "Pictogram" displays the pictograms for the exam type. Any pictogram can be configured into the library from the Presets / Pictogram List. The pictogram can be deleted from the imaging screen by pressing the "Delete" key on the Touch Screen. Press Pictogram and roll the trackball to position the transducer icon. The Pictogram transducer icon rotates by selecting the soft key rotary control below the Touch Screen or rotating the "Select" key on the Control panel when in the Pictogram function. The Transducer icon is displayed in green on the pictogram. 7 Notes 164 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Arrow Touch Screen Annotation Pictogram Arrow Mode indicator Arrow Functions New elect Arrow Delete Exit How Size Hotate Soft Key Functions Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Selecting the Mode "Arrow " displays the Arrow Functions. Add Arrows and Delete Arrow are done here. There are three sizes and three types for the Arrow (Small, Medium and Large) Manually adjust the arrow size using the soft key rotary control below the Touch Screen as well as rotating the Arrow. Note: The arrow size changes only the type selected in the Configuration Menu. Note, the length of the Arrow is not adjustable. The default size and type of the Arrow is configured in the Configuration Menu (Presets / General 2 / Common Mode). 8 Notes 165 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objectives Discuss Features ACUSON NX3 Perform Text Functionality and Customization Review Pictogram Functionality and Customization Describe Arrow Functionality Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. 9 Notes 166 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Alphanumeric Keyboard Report How Quick Set Presets Help Biopsy Appt Home Home Word Hide Chear Tent Pictogram Arrow T E 3 O -- Z A O W C A S D G H A C N CD 3 N Ctrl END Video Alt Alt Text A Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Pressing the "Preset" key provides access to the Configuration Menu. The Home Set, Delete Word, Hide Text, Clear Screen, Insert/Overwrite is accessed on the keyboard located at the top right. To manually type using the keyboard, press the "T" text key on the keyboard. - The system places the text cursor on the image screen at the Home position. - To reposition the text cursor, roll the trackball. Use the keyboard to enter text. - When you begin typing annotation text, the system displays a predefined label that matches the first characters entered when Auto Complete is set to the "ON" position. See Presets / Text Annotation/ Auto -Complete. To confirm the predefined text, press "Tab" on the keyboard(identified by the -><-) . Or, press the "Set" key on the home base twice. - The Down arrow on the left is "Caps Lock" Note: If you move the trackball or press the "Set" key once before confirming the predefined label, the text displayed to the right of the cursor is deleted. Note: The predefined label is confirmed when the image is stored. On the bottom row of the keyboard, Alt provides access to the special characters. Selecting Text A or Text B will cycle though six of the predefined text as labeled. These are the same as seen on the Touch Screen. 10 Notes 167 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Touch Screen Layout Annotation Pictogram Arrow Text A - Orientation Right Sagittal Cervix Endometrium Uterus Fundus Lef Trans Body Adnexa Ovary Folicle Superior Coronal Corpus Luteum Cul-de-sac Cyst Free Huid Library and User-defined Text Inferior Proxima Bowo Myoma Fibroid Hydrosalpiox Mid Kidney Distal Page Horne Position Get Home Position de Tex Clear Screen Delete Line Delete Word Text B - Position Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The Touch Screen divides the Text into: - Text A - These are the imaging views located in the first vertical column. Pressing the next one will replace the previous selection. - Text B is the positional text and located in the second column. These also replace each other as you select the next view. - The next four columns are the pre-defined library followed by the user-defined annotations. Note how they are separated from each other on the Touch Screen. User-defined are displayed horizontally after the pre-defined labels. The User selects which is displayed first (Library or user- defined) in the Configuration menu (Presets / Text Annotation). For some exam types, two pages of Text may be available. Swipe or touch the "Page" key to go to the next page. The Text is customizable in the Preset Menu (Presets / Text Annotation). 11 Notes 168 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Pre-defined Text Annotation Pictogram CH5-2 Abdomen 3 dB THI 3.1 MHZ Right Sagittal Right Sagittal Liver GB DR 65 dB Edge 1 Persist 3 Left Transverse Duct Head R/S 3 Map F Superior Coronal Rt Kidney t Kidney Tint 2 ASC 3 DTCE Med Inferior Proximal Hepatic V. Hepatic A. 19 fps Mid IVC Touch Screen Imaging Screen Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Each exam type has annotation labels for anatomical structures, imaging views, and body positions. To use pre-defined labels, Press "Text" on the keyboard. The system displays the list of annotations for the active exam on the Touch Screen. - Tap the required label. To reposition an annotation - Roll the trackball to position the cursor on the annotation and then press the "Set" key on the Home Base. The word will become active and turn "green". - Roll the trackball to the new location and press the set key to confirm the change. To edit an annotation - Roll the Trackball in the desired label to change and press the "Set" key. The text will become green. Select another text from the same group, and the text will replace. Or Roll the trackball to position the cursor to the right of the last letter on the annotation you want to edit and press the Set key twice. Press the backspace key on the keyboard (text will highlight in Green until the word is removed) and manually type or press a predefined label on the Touch Screen. - To cycle thought confirmed annotation, press the "Update" key or press the "Tab" on the keyboard. To Temporarily hide annotations, press "Hide Text" on the keyboard (top right) or on the Touch Screen. Press "Show Text" to show hidden Text. - Press the "ESC" (Escape) key on the Home Base to Delete all text and exit the text function. To Overwrite or insert text, Press the "Select" Key and highlight the thumbnail image. Press the Select key twice to load the image. One in a 1X1 format, press the Text key and then INS/OVR to overwrite the word. It will "X" over it, not replace. This can also be done when in Review. 12 Notes 169 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Customize Text Annotations Customize Text Annotation Customize Text Annotation" Exam & Quickset Venous Exam & Quickset Venous Text Annotation Library User Defined TextA Text B Text Annotation Library . User Defined -Test A Text B [VEN Macity Add > Tab Order User Defined Auto-Complete : On Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Create User-defined annotations in Presets/ Text Annotation. Select User-defined and type in the name for the Text and press "Add". Up to 25 characters are allowed for the label name including spaces. 13 Notes 170 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Customize Text Annotations Exam & Quickset Small Parts Tab Order Test Annotation . Library User Defined r Text A Test B Library Thyroid Isthmus User Defined Rit Thyroid Move Up Lt Thyroid Parathroid Node Nodule Sold Move Down Cyst Calcification Jugular ECA Breast -Tab Order Tests Epididymis User Defined Tunica Abuginea Mediastinun Scratal Septum Auto-Complete @ On c Off Spermatc Cord Varicocele Head BOCY Tail Auno-Complete On Mole DE: Default - Small Parts Save Cancel Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Customize the Library by Exam type. The user can modify, add, delete and arrange the order of the annotations in the Library. Text A and B are also customizable. In this menu, the "Auto Complete" function can be turned off and on. When enabled (selected), the system displays a matching phrase from the pre-defined text library based on the first few letters you enter using the keyboard. Note: To accept the displayed phrase, must press "Tab" key or "Enter" key on the keyboard. Or, double-click the "SET" key to accept the displayed phrase. The user can select the User-defined or Library as the first display on the Touch Screen. 14 Notes 171 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Customize Text Annotations General 2* Common Mode Delete Pictogram on Unfreeze Delete Text on Unfreeze Pictogram Location € Upper Right Lower Right Font Size 18 Arrow Size Medium (Type2) Patient Registration le-entry Measurement Result Display Size Medium Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Additional Text customization is available in Presets / General 2. Check "Delete Text on Unfreeze" for the on-screen text to delete once the Freeze key is pressed and the system is in live scanning mode. The Font size is adjustable from 12-20 pixels. The default is 18. 15 Notes 172 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Knowledge Check Healthineers Which Text type replaces each other when selected on the Touch Screen? Answer: Text A&B. When manual typing, I would like to have suggested text populate. Where do I turn on this feature? Answer: Presets / Text Annotation / Auto-Complete on. How do I move multiple words at a time? Answer: Moving text only can move one word. Set-up user defined text with more words for these users. Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This slide is animated. Use these questions to check that your learners understand the presented material. 16 Notes 173 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers Objectives · Discuss Features ACUSON NX3 . Perform Text Functionality and Customization Review Pictogram Functionality and Customization . Describe Arrow Functionality Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes 17 Notes 174 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Using Pictograms Annotation Pictogram Arrow 16 cm Rotate Delete Rotate Rotate Marker Pictogram Picto Touch Screen Imaging Screen Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Use the system presets to customize the pictograms assigned to an exam type, to change the location of the pictogram on the image, and to delete the pictogram when the image is unfrozen. Use the system presets to automatically display pictograms when you freeze the image (Presets / Exam Configuration/Automatic Freeze Response). The Image on the left is the Pictogram Touch Screen. Press the desired pictogram to change it on the image display. Select the soft key rotary control below the Touch Screen to rotate the Transducer Marker icon. The image on the right show the pictogram display located at the bottom right of the imaging screen. Note the transducer icon is in green. The Icons shown on the bottom of the imaging screen are the Home base controls. - Rotate Marker is assigned to the "Select "key. - Pictogram is assigned to the "Update" key. Continue to press to cycle through the list of available pictograms. - Picto is the function assigned to the Trackball which positions the Body Marker Transducer. - The last icon is the "Escape" control and will exit Arrow and return to 2D imaging. 18 Notes 175 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers Customize Customize Pictogram List Customize Pictogram List" Exam & Quickset Abdomen Exam & Quickset Abdomen All Pictograms Al Pictograms Add Delete More Front Move Boek Add Delote Move Front Move Bock Selected Selected Restricted E) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Customize the Pictograms for each exam type in the Preset Menu. - Select Presets / Pictogram List. - Select the Exam & Quickset you wish to modify. - Select an existing pictogram from the "All Pictogram" list and then select "Add". The system places the new pictogram at the bottom of the "Selected" list. (as shown on the right image). To Rearrange the pictograms - Select an existing pictogram from the Selected list. - To reposition the pictogram forward in the list, click "Move Front". - To reposition the pictogram backward in the list, click "Move Back". To Delete a pictogram - Select an existing pictogram from the "Selected" list and then select "Delete". - The system places the pictogram in the "All Pictogram" list. Remember to select "Save" to store the changes. 19 Notes 176 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Objectives Healthineers · Discuss Features CUSON NX3 . Perform Text Functionality and Customization . Review Pictogram Functionality and Customization = · Describe Arrow Functionality Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. 20 Notes 177 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Using Arrow feature Annotation Pictogram Arrow Arrow Size Rotate New Select Arrow Delete Delete All Exit how Size Rotate ( Rotate Arrow Select Arrow Arrow Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The image on the left is the Touch Screen Display. - Select "New" to add additional arrows "Select Arrow" moves between multiple arrow on the image screen "Delete" removes the active arrow "Delete all" removes multiple arrows "Exit" leaves the Arrow function Rotating the "Arrow Size" soft key below the Touch Screen changes the arrow from Small, Medium or Large. - Rotate the "Rotate" soft key below the Touch Screen to rotate the Transducer marker. The right screen is the image display when Arrow is activated. - Note how the active arrow is displayed in green. - The Home base controls work for the Arrow function as well. The Icons shown on the bottom of the imaging screen are the Home Base controls. - Rotate Arrow is assigned to the "Select " key. Select Arrow is assigned to the "Update" key. Continue to press to cycle through multiple arrows Arrow is the function assigned to the Trackball and positions the active arrow. - The last icon is the Escape control and deletes the active arrow. 21 Notes 178 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Knowledge Check Healthineers Where do I customize my Touch Screen display for Pictograms? Answer: Presets / Pictogram List. How many pictograms can be on the screen at one time? Answer: One, except in Dual (2 pictograms) and 4B (4 pictograms). How do I change the size of the Arrow when in real-time imaging? Answer: Rotate the "Arrow Size" soft key below the Touch Screen when arrow mode is activated. Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This slide is animated. Use these questions to check that your learners understand the presented material. 22 Notes 179 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary Text Arrows Pictograms Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only In summary, the Text, Arrow and Pictogram function can improve workflow by using the Touch Screen Functionality. 23 Notes 180 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Questions Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No Notes 24 Notes 181 Turnover Workbook | ACUSON NX3™ Ultrasound System 8. Connectivity Overview SIEMENS Healthineers System Installation Training Connectivity Overview ACUSON NX3™ Ultrasound System Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No speaker notes. Notes 182 Turnover Workbook | ACUSON NX3™ Ultrasound System Connectivity Learning Objectives Discuss the DICOM conversation ACUSON NXE · Describe the Local Host settings - (Wired vs Wireless) Explain the Storage Server Summarize the Worklist Server / MPPS functions · Review printing (DICOM) workflow Recognize the use for Query / Retrieve Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes Page 2 Notes 183 Turnover Workbook | ACUSON NX3™ Ultrasound System The DICOM Conversation Hello Network ... Hello NX3 DICOM application Network connectivity Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only The DICOM conversation is like any conversation between two people. It begins with a greeting and introduction and continues with some common ground. But the conversation has to be heard and both parties have to agree to continue speaking. The network conduit is the foundation - if it works then the DICOM agreed "talking points" are the common ground. Page 3 Notes 184 Turnover Workbook | ACUSON NX3™ Ultrasound System Connectivity Settings All network settings (wireless and wired) and DICOM configuration screens are here. 12 17 5 9 Presets key W R T Y U o P A D G H 2 X C V N M Ctrl END Alt Alt Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes Page 4 Notes 185 Turnover Workbook | ACUSON NX3™ Ultrasound System Presets Screen Configure Wireless Settings Gonetal 2 General 1 Penpheral Customize Keys Organization Display Hospital Name ACUSON NKS Exam Configuration User-Defined Exam List Text Annotation Format Pictogram List M & R Configuration Language English Summary Date Format Service Month DayYear Date & Time Setings .. Stress Etho Heigeed & Weight Foral SUS SieScace Metric CAI Wireless Audio Trackball Behavior DICOM DMAQ ULIY Beep on Key Press Trackdas Travel Speed Medum Clip Capire Configure DICOM Network Export Beep after Store Completes Archive Beep Volume Services Printer Line-in Volume : Boot Up Power Off Active Transducer Shutdown Confirmation Dialog LCt LC2 - LCS 7. Close Study on System Standby Save Cancel @ Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No speaker notes Page 5 Notes 186 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Local Host Tab Active Local Host settings General 1 General 2 DICOM Peripheral Customtuze Keys Local Host Siatage Server |Worklint Servee | MIP'S Servee | BW Printer | Calor Primiar | Query Retrieve Display Exam Configuration Local Host User-Dosned Geam List Test Annotation Pictogram List AL Tes M & R Configuration Summary Service Stress Echo MAC Adhs SieScape CAI Wireless Moda Type LECOM DIMAG Unity Clp Capture Network Export ( Addines Current wired network Submit Mast Archive Printer Default Gatjavay settings Save Cancel Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Notice that greyed out settings are active for selected profile. ? What is the reason for multiple profiles ? Page 6 Notes 187 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Local Host Tab Wired Network Settings Press "New" to edit profile General 1 General 2 DICOM Peripheral Customize Keys Local lled |Storage Server | Workthat Server | MPPS Server | EW Princee | Color Printer | Queryatreve Display Exam Configuration Local HHaut Show sobrert ilicuns User-Defined Exam List Test Annotation Pictogram List Sim Service Stress Echo SieScape CAI Wireless DHCP Media Type DICOM F Mapping Appicajas DIMAQ Utility Wired network address Cap Captare Fixed IP address Network Export Adthent AUTOSELECT TEBASET Authorization Bebeel Mail 1255 |255 35 0 1000BASETX fields now active Printer Don't forget to "Apply and Reboot" Save Cancel € Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Changing your profile means the system must reset its identity. Apply settings and exit out to live imaging screen - system will prompt for a reboot. Reboot only required for Local Host settings ... ?Why? Page 7 Notes 188 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Local Host Wireless Network Settings General 1 General 2 Wireless Porpheral Wireless Network Customue Keys Wireless enabled = Erabled Disabled ASUS USB AC51 USO Wireles __| Exam Configuration User Defined Exam List Test Annotabon Network Settings Pictogram List Available Network List Connection Inforstartion M & R Configuration Summary DICOMLAB 26 Sonice Stress Echo Sigral Strengt Available Wi-Fi networks SieScripe CAI Link Speed Wireless DICOM (Com)) POST Internet DIMAC USty Clip Capture NotwodeExport ((o)) SWSGP01 Authorization Archive Connection information Printer (Co-)) SWSGUESTOO US_Service IP Address Subnet Mask Gateway New. Connect Scan Refresh Properties Lock Saron Cancel @ Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only If Wireless Network is not selected then all this is greyed out Once enabled system will begin to detect available networks Enabled but not connected Page 8 Notes 189 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Local Host Wireless Network Settings Wapous Non-broadcast setwok ASUS USB AC51 USO Wireles -- Security settings (password + ) Security Type WPAZPSK Encrypton Type AES Connection Information Security Key Waipoul Signal Strength 100 Deletes network settings Link-Speed 135000 Kbps Select to configure network OK Cancel settings IP Address Walpoun Subnet Mask Gateway Edt Disconnect Scan Refresh Properties Lock Cancel Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only This is where you would enter the provided security information for the network This is also where you would delete old settings ?When might you want to delete old settings? Page 9 Notes 190 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Local Host Wireless Network Settings General General 2 Wireless Perpheral Wireless Network Signal and Link information Customize Keys Display Enabled Disabled ASUS USB AC51 USB Wireles- Exam Configurintion theat Cleaned Exam Lod Network Settings Text Annotabon Pictogram List wallatto Notwork List Connection Information M & R Configuration Summary SSD Connected Service FPWEB Stress Echo Signal Strengths 100 Link Speed: 135000 Kbps CA Wireless POST Internet DICOM DIMAQ Usbty Clp Capture (to)) SWSGPOI Connection information Network Export Authorum Auchve (Com)) SWSQUESTO3 Printer ---- ((on)) UR Service Waipoul PAstress Subnet Mask Gateway Edt- Disconnect Scan Refresh Properties Lock Save Cancel Siemens Medical Solutions USA, Inc. 2015 Global Cinical Education & Training Speaker Notes Only If Wireless Network is not selected then all this is greyed out Once enabled system will begin to detect available networks Page 10 Notes 191 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Storage Server General t General 2 DICOM Storage Server Peripheral Customize Keys Local Host. Storage Server | Wochlist Server | MPP'S Server ] BW Printer | Color Prister | Query Resieve Display DICOM / network settings Exam Configuration SHOWCASE User-Defined Exam List SHOWCASE Text Annotation Pictogram List PAdiese M & R Configuration Summary Par fhyster Service Ping and Etfra Trrecut in seconds Stress Echo SieScape New Exam workflow CN Wireless T". Autantore to DICOM DICOM I" Send leSahi TEE ciss lo tu DICOM sever DMAQ Utty Clp Capture IlAter Esey image is Stond # After All leuges an Stored 4D volume workflow Network Export Autorizadon Archive Seconde Hitwein Lach Ratty Connect Tireset as Seconds Storage Commit message frequency Salve Cancel Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Autostore to DICOM toggles PACS send on/off - useful for portable/bedside operations where you may not want to send till your ready ? Why might you not want to send to PACS on the floor? During/At end = In progress vs Batch sending Send fourSight = 4D volume send control - Not all PACS know how to handle the volume tags and size ?Has anyone ever had this as a problem - explain? Storage Commit - whether to send the response to the Server after every image or at end of exam Page 11 Notes 192 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Worklist Server Streamlined Search General 1 General2 DICOM Peripheral Customize Keys Display Local Hast | Storage Server Worklic Server MPP'S Server | B/W Printer Color Printer| QueryRetrieve| Exam Configuration Workdat Server User-Defined Exam L Teel Annotation Strict Verification Pictogram List M & R Configuration Summary Fan lierter Service Fay and Echa Tingout in secteos Stress Echo BioScape CAI Wireless DICOM Bric Verfcabas CIMAQ Utity Clp Captre Network Export Authorization Archive Printer Max number of worklist items Save Cancel Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Streamlined search - when enabled searches all procedures for the next 24 hours Strict Verification - verifies the standard DICOM tags on each study list retrieved from the server. Prevents downstream PACS /Workstation errors (e.g. 16 char space with 36 char package) Max number of worklist items ?why would this be handy? Page 12 Notes 193 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Worklist Search Workde Search - JDICOMRS @ JDICOURS Stans Peg OK Worldist .. Patient Name Palier ID Guy Description Accession Number DateTine Stevens Samantha C Mrs 00675073 GYN 40649 Lawless Chad 10/16/2015 17:50 97859397 Chad's only study descr 37089 10/16/2015 14:50 Worklist entry Guy Carosd 99802016 ScheduledProcedure St. 12000932 10/16/2015 10:57 Eyles Michael 47648083 Michael's only study des 41294 10/16/2015:14:50 Dreyer Westey 09725837 Westley's third shady de. 98765 10/16/2015 16:50 Brady Catal Mrs 63724372 GYN 03550 10/16/2015 15:50 Scheduled Piocadamuts) Descrption 1501 a's fourth Sched Prodecure Descri .. Suspended Scheduled Procedure Procedure Code and Meaning Code Making Reset cachel Search Sehict Cancul Siemens Medical Solutions USA, Inc. 2015 Global Cinical Education & Training Speaker Notes Only No speaker notes Page 13 Notes 194 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Worklist Search Wis Senich . DICOMRIS JDICOMIS Salis Ping CK Workdest Potert Namo Patient ID Eluy Description Accession Number Date/Time Stevens Samantha C Mis 06675073 GYN 48649 Lawless Chad 10/16/2015 17:50 97858397 Chad's orly study descr 37980 10/16/2015 14:50 Search Criteria Guy Carotid 99662016 ScheduledProcedureSt. Eylos Michael 47648083 Michael's only study des ... 12000932 10/16/2015 10:57 /41294 Dreyer Westley Brady Carol Mes 69725837 Westiey's third study de 10/16/2015 14:50 98765 10/16/2015 16:50 63724372 GWN 03550 10/16/2015 15:50 Patient Name Last Firs Midde Ultrasound only Patient ID Accession Number Performing Physician Last Firs Middle This system only Date Requested Procedure ID 10/01/2015 10/17/2015 to US Only This system only Worklist must support Search Cancel Clear Cancel this level of detail. Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only List side search fields ? What do you think is the most searched field? Ultrasound only and This system only - when or why would we use this? Page 14 Notes 195 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - MPPS Server Server conversation settings Generalt General 2 DICOM Peripheral Customize Keys Display Local Hast | Storage Server | Workdiist Server HPP'S Server |[UW Pristar | Calor Pristor | Query(Rosteve] Exim Configuration MEPS Saver Alas User Defined Exam List Test Arnotation AC Tik Pictogram List P Address M & R Configuration Summary Pot Munter Service Play and Etho Trreset in seconds Etress Echo Siescape Apply Casoil Pirg CAI Wireless DICOM Seconds Between Each Ruby DMAQ Utty Write Timeset in Becoret Store Image Format Clp Capture Network Export Conniet Treesal in Seconds Authorization Sters Frage Forrat New Uvasau Printer Bictoday Capture Cancel Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only ?What is MPPS and what is it for? ?Why is that important? Customizable server conversation settings - integration Store Image Format - specifies highest quality format that is supported by server - for MPPS servers that can't handle newer object types ?How are Worklist and MPPS related? - workflow Page 15 Notes 196 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Printing BW or Color General 1 General 2 DICOM Network timing adjustments Peripheral Customize Keys Display Local Host Storage Workdat Server| MPPS Server DW Parzer |Color Printer | Query(Retrieve Exam Configuration BIN Picar User-Defined Exam List Text Annotation AE TEM Pictogram List M & R Configuration Summary Port Number Service Stress Echo Sie Scape Apply Cancel Fing CAI Wiscless Herber of Trees la Fuly Falle DICOM Seconde Between Each Petty DIMAD UsIN Cap Capture Whhe Timmout in Seconda Network Export Connect Timenat in Seconds Authorization Archive Printer Daplay Farrat Copes more # Part When Page is Ful Piet & End al Ezan Print job timing Sal Cancel Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Network timing - adjustments for conversation timings Print Job timing - workflow for print jobs - as sheets fill or batch at end ?when would this be important? Page 16 Notes 197 Turnover Workbook | ACUSON NX3™ Ultrasound System DICOM - Query / Retrieve Servers and Workstations General 1 General 2 DICOM Penpheral Customize Keys Lacal los | Storage Serear | Wordist Server | MPPS Server | [WW Printer | Color Primer Query(Revieve| Display Exam Configuration OurFictieve Alat User-Defined Exam List Ofict Actus Text Annotation AE Tate Pictogram List IP Address M & R Configuration Summary Pat Master Service Ping and Echa Tirwout seconds Stess Echo SieScape Apoly CINE CA Wireless Herber of Tines to Fsby Fais DICOM Seconds Between Each Retry Timing adjustments DIMAQ Utisty Wie Sieseadi a Seconda Cap Capare Network Export Connect Timeout in Seconda Archive Printer Sive Cancel Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only Locations to query and retrieve images from - comparisons/fusion/multi-modality ?Give me some examples of something the NX3 might need to query? Page 17 Notes 198 Turnover Workbook | ACUSON NX3™ Ultrasound System Connectivity Learning Objectives · Discuss the DICOM conversation · Describe the Local Host settings - (Wired vs Wireless) ... · Explain the Storage Server · Summarize the Worklist Server / MPPS functions · Review printing (DICOM) workflow Recognize the use for Query / Retrieve Siemens Medical Solutions USA, Inc. 2015 Global Cinical Education & Training Speaker Notes Only No speaker notes Page 18 Notes 199 Turnover Workbook | ACUSON NX3™ Ultrasound System Questions Siemens Medical Solutions USA, Inc. 2015 Global Clinical Education & Training Speaker Notes Only No Notes Page 19 Notes 200 Turnover Workbook | ACUSON NX3™ Ultrasound System 9. Cardiology - Part 1 SIEMENS Healthineers System Installation Training Cardiology - Part 1 ACUSON NX3™ Ultrasound Restricted (!) Siemens Medical Solutions USA, Inc ., 201 Speaker Notes Only No speaker notes. Notes 201 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Objective ACUSON NXE . Explain cardiac transducers Review continuous-Wave Doppler · Recall physio location and functionality · Demonstrate Anatomic M-mode controls · Define Doppler Tissue Imaging (DTI) · Configure cardiac applications Restricted &) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Today, the objective of the course is to Explain Cardiac Transducers and Identify Imaging parameters Review Continuous-Wave Doppler Recall Physio location and functionality Demonstrate Anatomic M-mode Controls Define Doppler Tissue Imaging (DTI) . Configure and Enter Cardiac Applications Notizen 2 Notes 202 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Phased Array Transducer - Adult P4-2 Healthineers 64 elements phased array transducer 2D frequencies: 2.5, 3.1, 3.6 MHZ THI frequencies: 3.0, 3.4, 3.6, 4.0 MHz (display is the P4-2 received frequency) M-Mode THI F 3.0, 3.4, 3.6, 4.0 MHZ PW and Color Doppler frequencies: 2.2, 2.5, 3.3 MHZ CW Doppler frequency 2.0 only Maximum display depth: 300 mm Restricted €) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The NX3 system has two phased array transducers for cardiology. The P4-2 and the P8-4. P4-2 is the adult cardiac probe. The frequency is displayed as a receive frequency. 64 elements phased array transducer 2D frequencies: 2.5, 3.1, 3.6 MHZ THI frequencies: 3.0, 3.4, 3.6, 4.0 MHZ (display is the received frequency) M-Mode THI F 3.0, 3.4, 3.6, 4.0 MHZ PW and Color Doppler frequencies: 2.2, 2.5, 3.3 MHZ CW Doppler frequency 2.0 only Maximum Display Depth: 300mm Notizen 3 Notes 203 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Phased Array Transducer - Adult P4-2 P4-2 23.87mm 21.80mm P4-2 Original P4-2 Nosepiece -> Almost 8.67% elevation length reduce Slim nose-piece design 21.88mm Restricted < Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The P4-2 has been redesigned to a slim noise-piece to give better contact when scanning between rib spaces. Notizen 4 Notes 204 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Phased Array Transducer - Pediatric P8-4 Healthineers 64 elements phased array transducer 2D frequencies: 3.8, 5.3, 6.7 MHZ M-Mode: THI F 3.8, 5.3, 6.7 MHZ THI frequencies: 5.3, 5.8, 6.1 MHz PW and color Doppler frequencies: 3.6, 4.4 MHZ CW Doppler frequency 3.6 MHz only Maximum display depth: 14 cm Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only P8-4 is the pediatric phased array transducer and available only on the ACUSON NX3 Elite system. 64 elements phased array transducer 2D frequencies: 3.8, 5.3, 6.7 MHZ M-Mode: THI F 3.8, 5.3, 6.7 MHZ THI frequencies: 5.3, 5.8, 6.1 MHZ PW and Color Doppler frequencies: 3.6, 4.4 MHZ CW Doppler frequency 3.6MHz only Maximum Display Depth: 14cm Note: C8-5 Pediatric echo is also available (not covered on this presentation) No changes with that probe. Notizen 5 Notes 205 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Continuous Wave (CW) probes Healthineers CW2 CW5 Ped-Off Pencil Probe Restricted €) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The NX3 system has two continuous wave transducers - the 2MHZ Ped-Off probe and a 5MHZ Pencil probe transducers. Notizen 6 Notes 206 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers System Imaging Presets 20 Pen Gen Det DIO ClarifyVE DatifyVE Level LVO Contrast Split THI Edge Offset LUR Flip Full Size DICE Modify Map SynAps Clip Capture >> Clip Capture >> Mitate MutAberta MID 20 10V Maltalerta Map Page 1 Image Presets Page 2 LVO Contrast Restricted () Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The touchscreen display was covered very nicely in previous modules. I wanted to bring to your attention the benefits of the image presets as a workflow enhancement for ease of optimizing your images. Begin with Detail, General, then Penetration if needed. If you are performing a contrast study, use the left ventricular opacification setting located on Page 2 of the 2D touchscreen display. Notizen 7 Notes 207 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers P4-2 2D DEFAULT OPTIMIZED Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The left image is non-optimized image with the cardiac default. The left side is optimized by using the default general setting, initiating TGO, setting the overall gain down to -3, and then tipping in the RV area of the DGC. This is the consistent Optimizing workflow. Notizen 8 Notes 208 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS P4-2 Color Doppler Optimization Healthineers 24_09_2015_68_29_56 09: 18:42 Sa 24_09_2015_02_29_56 F 100% M1 0.75 TIS 1.6 718 10 10932 M1 0.74 Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The P4-2 color Doppler is optimized with an narrowed field of view. By decreasing the field of view of both the 2D and color box, there is higher frame rates and better display of the color timing. The color is sensitive in picking up small jets. The image on the left you can see a small jet of aortic regurgitation and the image on the right displays mitral regurgitation. Notizen 9 Notes 209 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS P8-4 Imaging Healthineers 100% MI072 P100% MIO.76 TIS 1:1 TB 14 Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is an example of the P8-4 on a child that is about 40 pounds (4 years old). There is nice detail noted. You could go to a harmonic imaging frequency to get higher heart rates. Notizen 10 Notes 210 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers". Cardiac Preset Recommendation Exam General 1 General 2 Exam Configuration* Configuration Peripheral Customize Keys Exam Cardiac Display Exam Configuration User Defined Exam List Automatic Freeze Response Cine Presets Text Annotation Pictogram List Seamless Dual On M & R Configuration Summary Steer Angle Type(VF 10-5 Only) * FOV.1 FOV-2 General 1 Service General 2 2D/M & 2D/Doppler Display Format Side by sid Peripheral CAI Delaut Doppler Update Style 2D-FroD-L Wireless Customize Keys DICOM DIMAQ UNNy Linear Steer Color invert On Display Clo Capture Exam Configuration Auto FOV with Color Activation · On c Off User-Defined Exam List Text Annotation Default - Cardiac Save Pictogram List M & R Configuration DHD Default Selection . 3D Auto FOV with Color Activition ® On Default - Cardiac Save Cancel Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To improve color Doppler frames per second and to improve workflow, it is suggested to turn ON the "Auto FOV (field of view) with Color Activation" within the system configuration found under the "EXAM CONFIGURATION". To do this, just place your cursor on the radial dial and depress select. Then SAVE. Notizen 11 Notes 211 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Cardiac Transducer - CW2 Defaults Healthineers 14_10_201K_14_12_23 CWI DR. 84 db C Ped echo default No Cardiac default No optimization performed optimization performed Restricted O Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The NX3 CW (Continuous Wave) signal default setting is used in this spectral Doppler tracing presented here. It can be furthered optimized but just pointing out that for an EMERGENCY ROOM echo performed by resident/fellow should capture all needed information without a lot of optimization. Note that the TGO is not active on the Ped-off probe but works very nicely on the phased array probe. Notizen 12 Notes 212 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Physio ECG module 6-pin connector Auxiliary Input 1 Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The ECG feature allows the system to display a scrolling ECG waveform on the image screen. Insert the six-pin ECG connector into the socket labeled ECG on the left side of the system. Auxiliary Inputs WARNING: The Aux 1 input is for peripheral equipment and not intended for direct connection to the patient. To connect an external auxiliary cable: 1. Connect the one-pin external auxiliary cable to the socket labeled "Aux 1" on the front of the system. 2. To connect the external auxiliary cable to a device (external source), see the device manufacturer's operating instructions. Notizen 13 Notes 213 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Physio Healthineers 2D Phy Aux Signal Invert Aux Signal Aux ECG Aux ECG Position 0 Resp Invert Position Gain ECG Resp Gain 4 ECG Lead Type Il Biggest Type 012 Delay Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only You can invert your physio, change the position, and increase or decrease your gain from the physio page. With the appropriate peripheral equipment, you can capture your ECG through an Auxiliary Signal and/or an Auxiliary ECG. Notizen 14 Notes 214 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Physio Resp Fr338 Position Gain 0 4 Restricted < Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only In the Physio module, You can enable the respiration curve by tapping on the RESP tab. You have the ability to change gain and position of the tracing. Notizen 15 Notes 215 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Clip Capture - from 2D Acquisition Healthineers 2D Phy Clip Capture >> Split THE Offset TGO Cair SieChoAt Off Trigger Type Chronology Acquisition Rate Full Size DICE Time Capture Prospective normal Low Clip Capture >> Time Capture Prospective 1 Normal Beat Capture Retrospective High Map 20 FOV R-wave Capture Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Clip Capture can be accessed through the touchscreen display. Select from time capture, beat capture, or r-wave capture under the TRIGGER TYPE title. Select prospective and retrospective under the chronology title and Select NORMAL and HIGH under ACQUISITION RATES. Notizen 16 Notes 216 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Clip Capture - System Configuration Healthineers Clip Capture Compression Beat Trigger Chronology - Low 11 . Prospective High r Retrospective C Trigger Type Time Trigger Trigger Type Time Capture 2 Ac Time Trigger r. Beat Capture 5 Time Capture R-wave Only Captur sec Beat Capture Beat Trigger 10 1 DONODAWN R-wave Only Capture beats 11 12 C 2 min (20fps) beats 13 3 14 Acquisition Rate 15 4 16 normal 17 8 c high 18 60 19 20 120 Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Clip capture can be put into an image preset by going to the System Configuration menu and selecting between time Beat or R-wave only capture Notizen 17 Notes 217 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers Anatomical M-mode (AMM) 2D M Phy - 3 Full M AMM AMM Clip Capture >> 3.6 MM Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only AMM (Anatomical M-mode) provides a view of the M-mode sweep based on patient anatomy and independent of the transducer orientation. It supports visualization of an M-mode sweep by rotating the M-mode cursor off axis. 1. Select M-mode. 2. From control panel, select AMM from touch screen. 3. Use angle knob and trackball to correctly position cursor. TIP: If you have activated M-mode and then decide that you want to deploy Anatomic M-mode, you need to exit M-mode back to 2D through the 2D knob, reactivate M-mode, and then select AMM from the touchscreen. Notizen 18 Notes 218 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Anatomical M-mode (AMM) 20 AMM Phy Full M Sweep MAip Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Once the anatomical M-mode is activated, the touchscreen above will be displayed. To steer the M-mode, use the trackball. To adjust the angle, use the angle button located on the keyboard. Notizen 19 Notes 219 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Doppler Tissue Imaging (DTI) Healthineers Triplex Update Rate Auto Stat Sensitivity Off Abv 3 Full D Gate Sweep 1.5 mm 4 DTI T/F Res F Invert 1/1 Restricted O Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Tissue Doppler Imaging can be achieved by suppressing the high-pass filter but setting the threshold filter so that the low frequency, high amplitude myocardial signals will be detected. Tissue Doppler imaging can be utilized in a Pulsed Wave TDI mode or a Color Doppler TDI mode. PW DTI and color Doppler DTI can work independently of each other. To access PW DTI during acquisition/live imaging, select the DTI choice displayed on the touch display panel during pulsed wave imaging mode. Notizen 20 Notes 220 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Healthineers PW DTI Update Off DR 35 dB Map F Tint 2 06 mm Sweep 4 Gate 3.0 mm TIF Res F Angle 0 55 fps -cm/s .10 20 .......................................................... ................................................................................ ............................................................... Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The default settings are used in the image above. No significant optimization is needed. Notizen 21 Notes 221 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Color DTI ACUSON NX3 18:40:02 Th 15/10/2015 15_10_2016_10_37_34 P4-2 Cardiac 2.2 MM: 977 H: Filter 1 R/S 3 Mag C Priceity 3 Smooth 2 Flow M DICE Low P 100% MI078 39 bpr Restricted E) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To initiate Color Doppler Tissue Imaging (color DTI), just tap on the DTI button when in color Doppler. Access color Doppler DTI is the same workflow as PW DTI -- the DTI button is in the exact location for both PW and DTI - utilizing muscle memory to improve ease of use. PW DTI and color Doppler DTI can work independently of each other. Notizen 22 Notes 222 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Presentation Continued in "Part 2" Healthineers Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Notizen 23 Notes 223 Turnover Workbook | ACUSON NX3™ Ultrasound System 10. Cardiology - Part 2 SIEMENS. Healthineers System Installation Training Cardiology - Part 2 ACUSON NX3™ Ultrasound Restricted (C) Siemens Medical Solutions USA, Inc ., 2017 Restricted O Siemens Medical Speaker Notes Only No speaker notes. Notes 224 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers' Setup Cardiac CAPS- Presets Customize Keys General 1 General 2 Customize Keys* Customize Key Key Direction 1 Key Depttx(+) * CW COW Focus(+) " CW G OCW Exam Configuration Stress Echo User-Defined Exam L Zoom(+) r CW - CCW Test Annotation Pictogram List Key Function 2 Key M & R Configuration Homebase Key 1 Key Summary Customize Stress Echo Auto Left Heart Stress Echo Son Key 2 Key SieScape Customze Auto Let Heart 3 Key CAI Wireles Print Store 1 Key 3 Key DICOM DIMAQ Unity Diok Store Axus-EF Axius-EF Cip Captare Prins Store 2 Key Network Export Disk Store JECG 4 Key Authorization Archive Cip Store Key 5 Key ECG Printer Cap/Volune Store Sie Scape Let Pedal UD KEY 5 Key Freeze Right Pedal SieScape Disk Store JD Key END Key Cause study Close study and reload boot sp sethro Split Save Cancel Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Within the system configuration under PRESETs, Axius™ edge assisted Ejection Fraction, Auto Left Heart, and Stress Echo can be programmed to a user defined key found under the customize keys page. Use the drop down menu from the key function and make your selection. The ACUSON NX3™ Elite Ultrasound is a two tier system for automated ejection fraction offering both syngo® Auto Left Heart (Auto LH) and Axius™ Edge Assisted Ejection Fraction. Both utilize a knowledge-base imaging to recognize patterns and provide a level of accuracy and consistency in adult cardiac quantification of ejection fraction. Notizen 2 Notes 225 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Access During Acquisition Healthineers Customize Keys 1 Key 3 4 5 Stress Echo 2 Key Auto Left Heart 3 Key Axius-EF Review Report 4 Key ECG 5 Key SieScape ---- ----- UD Key Split Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To access the applications programmed on the customized keys, select the button which corresponds with the designated key. Notizen 3 Notes 226 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Access During Review Healthineers Study Apps. Study Screen Apps. Screen Hide Controls Select All Mark Image Show Marked Format Delete Export Image Teaching Für Review Report Axiux-EF Auto LH AHP Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only You can also access applications from the review screen. From the review touch display study screen, select the APPS tab. Then select the AXIUS EF TAB, or Auto LH tab. (Stress echo is not available from review - only Acquisition) Notizen 4 Notes 227 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Axius Ejection Healthineers Specity View: A4C A2C EF X SV on/) CO (Lmiro) HR (tom) 55 Select A4C or A2C Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Working with Axius Ejection: Select either A4C and A2C, with a point and click then the application will launch the application Notizen 5 Notes 228 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Axius Ejection Healthineers Specify View: Axius-EF Guided Manual A4C 42C Restricted ED Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Axius Ejection is an automated application to calculate left ventricular ejection fraction. When using Axius Ejection, select the specific LV view. The application will default to the GUIDED AXIUS-EF setting. Notizen 6 Notes 229 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Axius Ejection Healthineers ACUSON NX3 CAPS, AXIUS EF 04_10_2015_09_05_43 09:20:37 Tw 06/10/2015 Xxlus-EF ES 841 Guided Manual Ovite Entre AZC Exit Guided EF %: 513 ESV Im0 509 Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only To GUIDE the border detection, place three calipers. Start at the annulus, then place one at the Apex, then the opposite annulus (it doesn't matter if you begin or end at the lateral annulus). At the last point, the system will display the LV tracing. A computer aided diagnosis (CAD) methodology involving a series of actions in sequence whereby the auto EF algorithm analyzes images to compute volumes and EF using learned pattern behaviors from the training of a human expert. Notizen 7 Notes 230 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Axius Ejection Healthineers ESMA Editing Border Editing Axis Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only There is the ability to edit if you would like to override the application. Select BORDER on the touch display panel Place your caliper were you would like the border to move to. Begin drawing the new border destination. When you are finished, choose SET (key left or right of the trackball) and the edit line will become the new border. The left side is an example of editing the border. To edit the location of the AXIS, select AXIS on the touchscreen display, click to the desired location and the AXIS marker will "jump" to the new location. The right side is an example of editing the axis. Notizen 8 Notes 231 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS. Axius Ejection Healthineers Axius-EF ES #11 ES 811 Guided Manual Trace Mark Trace Mark Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only If the application cannot perform the automation, you have the ability to manually trace the border. Just tap either trace or Mark on the touchscreen. Note: when you MARK, you can space anywhere you would like. With Trace, if you move the trackball slowly, the trace becomes more detailed. As you speed up the trackball movement, the points will become spread at a farther distance. Notizen 9 Notes 232 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Axius Ejection Healthineers ED AT ------ ANUS EP EF %. 412 Deste time |_Delete Cet Accept Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The measurements will be transferred into the report page when completed. Notizen 10 Notes 233 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Auto Left Heart Healthineers A4C Anterior Soft KeyT Soft Key2 Soft Keys Soft Key A&C Contrast A2C Contrast Cip Transfer Completed Anterior Exit Imaging Screen Touch Panel Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Working with Auto Left heart: Once you have select the Auto LH application, you will select your view. Select either LV or LA by using Soft Key 3 if you want to quantify the LV or Soft Key 4 if you would like to quantify the LA. OR place cursor and click selection. The LV choices are A4C, A2C, A4C with contrast or A2C with contrast. The LA choices are A4C and A2C. Select the view by placing your cursor on the view and confirming your selection with the select button on the consult, located to the left and the right of the trackball. syngo ®Auto left heart will launch and make all the requested measurements without need for any further interaction. Notizen 11 Notes 234 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Auto Left Heart Healthineers A4C AZC ED. Anterior Cip Transfer Completed EFX ESV LV LA 73 320 76 Cycle Change Unita 7Manda Selection Launched Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only The LA choices are A4C and A2C. Select the view by placing your cursor on the view and confirming your selection with the select button on the consult located to the left and the right of the trackball. Or use the corresponding soft keys. syngo® Auto left heart will launch and make all the requested measurements without need for any further interaction. Notizen 12 Notes 235 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Auto Left Heart Healthineers EF% EDV ESV HR (ml) (mi) (bpm) LV LA 73 8.7 32.0 76 Cycle: 4 1 2 EFX Volume Graph (Single Plane Simpson's Rule) LA LV LA 73 76 Cycle 2 Saved results Results Restricted @ Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only You can select to Save your results by using soft key 3 on the touchscreen display or by using the cursor on the corresponding tab on the application. Once you see the selection saved, you can not longer edit or add the left ventricle/left atrium to be measured. You will need to leave the application and come back-in to work with the application. Here you can see that the system calculated EF%, end diastolic volume, end-systolic volume, and documented the hear rate. All the results are placed on the volume graph curse based on the Single Plane Simpson's Rule. You can also make a selection to measure a second cycle if it has been captured. Notizen 13 Notes 236 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Auto Left Heart Healthineers A4C A2C Editing Trace Anterio Place caliber Grab and drag A4C Contrast A2C Contrast Clip Transfer Completed Anterior Fip LofVRight LV LA Restricted ) Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only This is a short video showing you that in just a few seconds, the left ventricular end diastole and end systole LV analysis is completed. Intentionally, I've picked a clip that Auto Left Heart did not pick up the APEX to show you how easy and fast it is to edit. Place your caliper on the active border Grab the border by holding down the SET key and then DRAG the border to desired location by moving the trackball. When you have the border in the new location, let go of the SET key. Use the same technique with the AXIS. Notizen 14 Notes 237 Turnover Workbook | ACUSON NX3™ Ultrasound System 11. Cardiology - Part 3 SIEMENS Healthineers System Installation Training Cardiology - Part 3 ACUSON NX3™ Ultrasound Restricted (!) Siemens Medical Solutions USA, Inc ., 2017 Restricted O Siemens Medical Speaker Notes Only No speaker notes. Notes 238 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Auto Left Heart Healthineers Manual Trace Mark Draw Backspace EFX EDV ESV (mi) HR (bpm) LV Cyclo: 42) Exit Mark Draw Auto / Manuel Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only If the system is unable to perform an automated measurement, you have the option to perform a manual trace. Select Mark or Draw. You can use the BACKUP soft key to go back one place or use the system controls for continuous backup. If Draw, place the caliper, SET, then use the trackball to DRAW the LV contour. Notizen 2 Notes 239 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Auto Left Heart Healthineers ED EF% EDV ESV HR (mi) (ml) (bpm) LV 43 80.2 45.3 LA 73 8.7 32.0 76 Cycle: 1 2 Exit Change Units Volume Graph (Single Piane Simpson's Rule) LV EFX LV 43 73 320 76 LA Time (ms) Cycle4 Volume Graph (Single-Plane Simpson's Rule) LA Change Unis A- 7 Manual LV and LA Time (ms) Save Auto / Manual Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only You can also make a selection to measure a second cycle if it has been captured. Or select another segment e.g. LV or LA. If both LA and LV are selected on the same image before saving, the data will be displayed on the same display as seen on the left image. Notizen 3 Notes 240 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Auto Left Heart APS, AUTO LEFT HEART Of_18_2015_09_25_26 CAPS 06_18:2018__29_28 ----- Auts Les Hears EFS LV 58 LA 73 87 Delese Al Deste Line Delete Cell Send Report Cycle: 4 Saved Quantification Cardiology Worksheet Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only Once you are content with your results, exit the application by selecting exit on the bottom left of the information bar or using soft key #1 on the touch screen display. Notizen 4 Notes 241 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Summary Explain cardiac transducers Review continuous-Wave Doppler Recall physio location and functionality Demonstrate Anatomic M-mode controls Define Doppler Tissue Imaging (DTI) Configure cardiac applications Restricted & Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only You should now be able to: Explain Cardiac Transducers and Identify Imaging parameters Review Continuous-Wave Doppler Recall Physio location and functionality Demonstrate Anatomic M-mode Controls Define Doppler Tissue Imaging (DTI) Configure and Enter Cardiac Applications Notizen 5 Notes 242 Turnover Workbook | ACUSON NX3™ Ultrasound System SIEMENS Healthineers Questions? Questions Restricted Siemens Medical Solutions USA, Inc ., 2017 Speaker Notes Only No Speaker Notes. Notes 243 On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products included in this brochure are available through the Siemens sales organization worldwide. Availability and packaging may vary by country and is subject to change without prior notice. Some/All of the features and products described herein may not be available in the United States. The information in this document contains general technical descriptions of specifications and options as well as standard and optional features which do not always have to be present in Local Contact Information individual cases. Siemens Medical Solutions USA, Inc. 40 Liberty Blvd. Siemens reserves the right to modify the Malvern, PA 19355-9998 design, packaging, specifications and USA options described herein without prior Telephone: +1-888-826-9702 notice. Please contact your local siemens.com/healthcaree Siemens sales representative for the most current information. Legal Manufacturer 1230 Shorebird Way Note: Any technical data contained in this document may vary within defined P.O. Box 7393 tolerances. Original images always lose Mountain View, CA 94043 a certain amount of detail when USA reproduced. Telephone: +1-888-826-9702 siemens.com/healthcare Siemens Healthcare Headquarters Siemens Healthcare GmbH Healthcare Sector Henkestr. 127 91052 Erlangen Germany Phone: +49 9131 84-0 siemens.com/healthcare Published by Siemens Healthcare GmbH · Order No. HOOD05162002872447 · Printed in USA · © Siemens Healthcare GmbH, 2017
- Acuson
- NX3