ACUSON Redwood™ Ultrasound System | 2.0 Upgrade | GI
This course includes information on the 2.0 upgrade for the ACUSON Redwood ultrasound system.
Continue Button Continue HOOD05162003235126 | Effective Date 9-Nov-2021 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 ? ACUSON Redwood™ Ultrasound System | VA2.0 Upgrade This online training familiarizes the learner with enhancements from the latest upgrade available for the ACUSON Redwood system. Please refer to the objectives that are listed below. There is no audio accompanying this online training. Select Next to proceed. Review interface, configuration, and export improvements 1 2 Evaluate new transducers and expanded capabilities Welcome ? User Interface | Retractable Keyboard The VA2.0 upgrade offers a retractable, tactile alphanumeric keyboard that stows beneath the control panel and supplements the virtual keyboard. Keyboard supports these languages English French German French Spanish Italian Hover over the image to see how the keyboard deploys. User Interface | Retractable Keyboard ? 7VC2 | New Transducer Redwood VA2.0 features an automated 3D/4D transducer that supports Gynecology, Obstetrics, Abdominal, and General exam types. 7V2 | New Transducer ? 9VE4 | New Transducer The Redwood VA2.0 offers this new intracavity transducer that has excellent 2D image quality and features automated 3D/4D imaging. In addition, this transducer supports Obstetrics, Early OB, Gynecology, and General exam types. 9VE4 | New Transducer ? 9EC4 | New Transducer General, Early OB, Gynecology, and Prostate exams are now supported using the 9EC4 transducer. Freehand 3D is supported while in the Gynecology application. 9EC4 | New Transducer 18H6 | New Transducer Clinical Applications include Superficial Musculoskeletal and Pediatric Thyroid. Click or tap the images to animate the video and zoom the image. Select the orange marker to read more about the image. Review some features by selecting the 18H6 Transducer. ? Median Nerve The sagittal medial nerve shown here demonstrates the classic appearance of alternating bright and dark layers. 18H6 | New Transducer Clinical Image | 18H6 The 18H6 transducer supports: Contrast-Enhanced Ultrasound Exams (CEUS) Panoramic Imaging Compounding eSieScan™ workflow protocols UltraArt™ universal image processing Auto TEQ Color Doppler Frequencies - Low, Mid, High, and Resolution Color Doppler Presets - Low, General, and High Pulse Wave (PW) Doppler Frequencies – Mid and High Select the X in the upper right-hand corner to close this page. ? Performance Improvements to 9C3 2D image clarity, resolution, and Doppler contrast have been optimized for OB and Fetal echocardiography exam types. Click or tap the image to view the video example. Performance Improvements – Overview Performance Improvements to 9C3 ? Performance Improvements to 5C1 and 4V1 Both transducers have a usable depth of up to 40 centimeters (cm). Performance Improvements – Overview Performance Improvements to 5C1 and 4V1 ? Performance Improvements to 18L6 The ACUSON Redwood VA2.0 supports Contrast-enhanced Ultrasound (CEUS) on the 18L6. Select the numbered steps below to learn more about the CEUS supported applications and transducers available with the VA2.0 upgrade. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 Performance Improvements to 18L6 Contrast Begin Start Contrast Mode by selecting Contrast from the Control Panel. The Contrast control will not be backlit when Contrast mode is not supported. 2 Select the X in the upper right-hand corner to close this page. General Abdomen Gyn Prostate Thyroid MSK Breast Testis LVO Vue Box™ 18L6 18H6 10L4 5C1 9C3 9EC4 4V1 5V1 Contrast Supported Transducers and Exam Types Left Ventricular Opacification Option Compatible with VueBox™ software application from Bracco Diagnostics Inc. 1 Table with 10 columns and 9 rows General Abdomen Gyn Prostate Cardiac Thyroid MSK Breast Testis 5C1 9C3 4V1 10L4 18L6 18H6 9EC4 5V1 Select each of the orange markers for more information about new CEUS exam types. Select the X in the upper right-hand corner to close this page. New CEUS Exam Types and Supported Transducers are shown in Orange Country Regulations on CEUS Usage Check regulations for the country that this system is being used for CEUS imaging. At the time of publication, the United States Food and Drug Administration has cleared contrast agents only for use in left ventricular opacifications (LVO), liver, and vesicourethral reflux (VUR). ? Updated | Patient Banner Patient Name Patient ID Age/Date of Birth, Gender EDD, GA Institution name Date, Time Performing Physician, Operator The Patient Banner configuration has been updated, with new patient overlay options that are shown here highlighted in orange. Updated | Patient Banner ? Patient Banner | Still Images All information displayed on the patient banner will be overlaid on exported still images and DICOM (Digital Imaging and Communications in Medicine) unless De-identified on Export. Hover over each image for image format information and hover over the marker for more information about de-identification. De-Identifying Steps To de-identify patient banner information: Select Review from the Touch Screen and choose Export Choose the export format Beneath Identification, check the De-identify Rename the file or choose the default label Anonymous Click or tap the Export menu to zoom in and review the De-identify features. Click or tap once more to close the menu. Patient Banner | Still Images ? Arrow Configuration Update The user can to save the last Arrow (type, color and size) that was placed before exiting. Arrow Configuration Update ? Annotation Option Added The user can select the default Annotation (Text, Body, or Arrow) or return to the last Annotation used. These choices are located in System Configuration under Custom Keys, then select ‘Remember the last selection,’ Text, Body Marker, or Arrow. Annotations and Arrows ? Fetal Comparison Compare and present multiple fetus morphometric data side-by-side. This comparison data may be stored to the report or exported to USB. Fetal Comparison ? Growth Percentile The Exam Specific Information about the growth percentage by chart type and by measurement type may also be stored to the report or exported to USB. Growth Percentile ? Add 1 Week to the Estimated Delivery Date (EDD) When configuring obstetric reports, the EDD can be extended to display an additional week by selecting System Configuration, Measurement & Report, Measurement and select ‘Add 1 week to EDD’. Hover over each marker for more information. Gestational Age (GA) or Estimated Delivery Date (EDD) When configured and the user manually enters the EDD or GA, the last menstrual period (LMP) or Invitro Fertilization (IVF) is automatically calculated and entered by the system. Note that this setting cannot be changed during an active exam. Also, an exam restarted follows the setting when the study was created and cannot be changed. This newly added reporting configuration applies to OB and Early OB exam types. Chart Explaining the Option on Patient Banner and Report The Patient Registration, Banner, and Report are checked with and without the ‘Add 1 week to EDD’ option. Add 1 Week to Estimated Delivery Date (EDD) ? Report | Export Format Options A new report style Rich Text Format (RTF), is available along with Paperless Document Format (PDF). To export the report as a document: Insert a USB into one of the connecting ports on the ACUSON Redwood system Select Export from the Touch Screen or imaging screen Then choose the desired format PDF, RTF, or both Report | Export Format Options ? Choose S-Video Options Video output selections now include National Television Standards Committee (NTSC) or Phase Alternating Line (PAL) format types. The user can choose the S-Video Format in System Configuration under System Settings, then General. Choose S-Video Options ? Course Review Congratulations. You have completed the course ACUSON Redwood™ System | VA2.0 Upgrade. Select the numbered buttons below to review the material provided. Review interface, configuration, and export improvements 1 1 1 2 2 2 Evaluate new transducers and expanded capabilities Course Review Evaluate new transducers and expanded capabilities 7VC – New transducer with automatic volume rendering for gynecology, obstetrics, abdominal, and general imaging exam types 9VE4 – New transducer with automatic volume rendering for gynecology, obstetrics, and general imaging exam types 9EC4 – New transducer for manual volume acquisition for gynecology exams 18H6 – New transducer for the 2.0 upgrade that is targeted for superficial imaging 9C3 – Optimized 2D clarity, resolution and Doppler contrast 5C1 and 4V1 – Now both transducers are capable of 40 cm depth penetration 18L6 – Added Contrast-Enhanced Ultrasound (CEUS) capability Select the X in the upper right-hand corner to close this page. Review Interface, Configuration, and Export Improvements Select the X in the upper right-hand corner to close this page. Retractable alphanumeric keyboard tucked beneath the control panel USB export as RTF or PDF format Video Export as NTSC or PAL Annotation ‘Remember the last selection’ Added ‘Always save the arrow last placed before annotation exit’ for Arrow function Newly added items on Patent Banner Disclaimer Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. ACUSON Redwood™ Ultrasound System, UltraArt™ universal image processing, and eSieScan™ workflow protocols, and Auto TEQ™ optimization are a trademarks of Siemens Medical Solutions USA, Inc. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com ? Disclaimer Disclaimer Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the Online Training ACUSON Redwood™ Ultrasound System | VA2.0 Upgrade. Completion Navigation Help Select the icon on the upper left-hand side to open the table of contents. Select > Next to advance or review main pages using < Prev icons on the lower right-hand side of the slide. Exit this Navigation Help slide by selecting the . Click or tap to zoom images with the magnifying glass icon. Select the orange X in the upper right-hand corner to close subpages. Welcome Slide Question Bank 1 HOOD05162003235126 | Effective Date: 9-Nov-2021 Acoustic Data This term describes an aggregate of the analog (acoustic) data collected during image collection that is exported in table format CSV (comma-separated values) or spreadsheet format (Microsoft Excel). AVI Audio Video Interleave file format. CEUS This acronym stands for Contrast-enhanced Ultrasound includes imaging techniques that utilize microbubbles (ultrasound contrast agents) to enhance soft tissue and blood boundary interfaces. DICOM Digital Imaging and Communications in Medicine are the standard for medical imaging information. EDD Estimated delivery date. Hard Copy This term describes images that are printed on film. LVO Left Ventricular Opacification. NTSC National Television System Committee analogue video standard. PAL Phase Alternating Line analogue video standard. PDF Paperless Display Format. RTF Rich Text Format. TIFF This acronym is Tagged Image File Format. VueBox VueBox™ is a general-purpose software application for quantifying tissue perfusion using Dynamic Contrast-Enhanced Ultrasound (DCE-US). This ultrasound contrast software application is a cross-platform analysis software from Bracco Diagnostics Inc. For information regarding the software application, refer to the manufacturer's instructions. 1 HOOD05162003235126 | Effective Date 9-Nov-2021 1.1 Welcome 1.2 User Interface | Retractable Keyboard 1.3 7V2 | New Transducer 1.4 9VE4 | New Transducer 1.5 9EC4 | New Transducer 1.6 18H6 | New Transducer 1.7 Performance Improvements to 9C3 1.8 Performance Improvements to 5C1 and 4V1 1.9 Performance Improvements to 18L6 1.10 Updated | Patient Banner 1.11 Patient Banner | Still Images 1.12 Arrow Configuration Update 1.13 Annotations and Arrows 1.14 Fetal Comparison 1.15 Growth Percentile 1.16 Add 1 Week to Estimated Delivery Date (EDD) 1.17 Report | Export Format Options 1.18 Choose S-Video Options 1.19 Course Review 1.20 Disclaimer 1.21 Completion
- 2D
- 3D
- 4D
- ACUSON
- ACUSON Redwood
- Alphanumeric
- Annotation
- CEUS
- Contrast DICOM
- Doppler
- Echo
- Echocardiography
- Export
- Freehand
- Fetal Echo
- GYN
- Keyboard
- MSK
- New Transducer
- NTSC
- OB
- Obstetrics
- OBGYN
- PAL
- Rocking
- Retractable Small Parts
- Still Image
- Thyroid
- Ultrasound
- Upgrade
- Vascular
- Women's Health
- Redwood VA2.0
- EDD Expected delivery date
- Estimated delivery date Add 1 week
- Add one week to EDD
- Arrow
- Contrast enhanced ultrasound
- Contrast-enhanced ultrasound
- De-identify
- Deidentify
- De identify
- Panoramic
- Prostate
- Gynecology
- Endovaginal Obstetrics
- Abdominal
- Musculoskeletal
- ll transducers with this release