ACUSON Redwood™ Ultrasound System 2.0 New Obstetrics and Gynecology Features
This course includes information on the 2.0 upgrade, specific for the added OB/GYN features for the ACUSON Redwood ultrasound system.
Continue Button Continue HOOD05162003237828 | Effective Date 1Dec21 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 ? ACUSON Redwood™ Ultrasound System VA2.0 New Obstetrics and Gynecology Features Highlighting new Obstetrical (OB), Gynecology (GYN) features and ease of use provided with the latest upgrade available on the ACUSON Redwood system. There is no audio accompanying this online training. The objectives are listed below. Select Next to proceed. Discuss new transducers and functionality 1 2 Review new reporting features Welcome ? ACUSON Redwood System The ACUSON Redwood™ ultrasound system provides both an economical and high resolution imaging solution for the ultrasound department. The ACUSON Redwood System delivers excellent flexibility within the department across a wide range of imaging modalities. Not only delivering excellent image resolution in 2D, Color Doppler Velocity (CDV), pulse wave Doppler (PWD), Contrast, three-dimensional (3D) and four-dimension (4D) volume data, the system is also designed for portability. Other benefits provided are many of the transducers can be utilized across multiple systems, such as the ACUSON Sequoia™ u ltrasound system and the ACUSON Juniper ™ u ltrasound system. Contact your ACUSON system Representative for a full list of transducer compatibility. ACUSON Redwood System ? ? 7VC2 | New Transducer The 7VC2 transducer is new to the ACUSON Redwood system and features 3D/4D volume imaging within the OB, GYN, Abdomen (ABD), and General applications. This transducer provides a wide-range of 3D and 4D volume applications as well as delivering excellent 2D imaging. Allowing a broader use of this transducer within the exam. Select each of the tab arrows to learn more about the 7VC2 transducer. 3D/4D Tools 3D/4D Review of Controls 2D Features 7VC2 Images Trackball Configuration 7VC2 | New Transducer Press NEXT at bottom right of page to continue or press the X in the right upper corner. Press continue when ready to return to 7VC2 Image page. > Continue Press continue when ready to return to 7VC2 Image page. > Continue Four on one display of volume and MPRs. Press continue when ready to return to 7VC2 Image page. > Continue Press continue when ready to return to 7VC2 Image page. > Continue Global 3D and 4D Trackball Configuration The trackball is programmable in the Configuration Menu to meet user’s workflow. Click the trackball to view a short video on trackball customization. 7VC2 Images Click or touch each box to view examples of images from the 7VC2 transducer. Excellent 2D imaging Traditional Tool Availability Rapid 3D Volume Acquisition Beautiful 4D Volumes 3D/4D Tools The 7VC2 transducer provides an automated sweep angle from 20 to 90-degrees in both 3D and 4D volume imaging. One touch tools are available to quickly adjust the MPRs and Volume: UltraArt™ universal image processing Angle – adjustment of volume sweep angle Quality – sweep speed and resolution of volume Review Job Aids under RESOURCES Click the image to play the short 4D video. 4D imaging of an early fetus. 3D/4D Controls There are ergonomically positioned controls located on the control panel for easy activation. These controls allow activation, rotation and paging through the active MPR or volume rendered (VR) images. Controls enlarged below are outlined in orange. Click or tap the Control Panel image to enlarge. 2D Features The 7VC2 offers an inclusive package for the OB exam. Including: Comparison of up to four serial reports Inclusive selection of configurable Authors and Percentiles Ability to tailor displayed information: Banner data Physician and Operator on Report Comprehensive measurement package One touch eSieOB measurements Click or tap the image to play video. Press the X in the upper right corner to return to the main page. 2D Features The 7VC2 is a broadband transducer with a frequency range from 2 to 7 megahertz (MHz). Offering excellent 2D imaging, tissue harmonic imaging (THI), Color Doppler Velocity, pulse wave Doppler, and SieScape™ panoramic imaging. One button push tools, such as: UltraArt™, Auto TEQ™ image optimization, Auto TEQ™ Doppler, eSieOB measurements and eSieScan™ workflow protocols, allowing a wide range of utilization for this transducer. Click or tap the image to zoom. Press continue to learn more about 2D imaging features. > Continue ? 9VE4 | New Transducer The 9VE4 transducer is now available with the ACUSON Redwood VA2.0 software upgrade, and provides an automated 3D or 4D volume acquisition. The 9VE4 supports General, Early OB, and Gynecology applications. Select each tab arrow , to learn more about the 9VE4, 3D/4D imaging. 3D and 4D Clinical Application MPR Overview VOI Adjustments 9VE4 Clinical Images 9VE4 | New Transducer 9VE4 | Clinical Images Click each image to zoom. A comparison is made of the same image and volume. Changes to the VOI depth is the only adjustment made to the volume. Note: a deeper VOI allows greater contrast resolution to be displayed within the VR image. VOI Adjustments Continued Turning the volume on its side, helps to compare the depth of the VOI. The width of each VR is demonstrated with the blue double arrows. The Cut Line divides the entire volume across the elevation width and is identified as the green box when turned on its side. Back < VOI Adjustments The VOI determines the depth of the volume in the VR plane, (from the Cut Line to the bottom of the VOI). Adding depth to the VOI adds contrast resolution within the VR image. An example is viewed to the right. Hover over the image to see: Cut Line in Plane A and VR demonstrated with yellow arrows Depth of VOI demonstrated with blue double headed arrows Plane C or gray box indicates the surface of the Cut Line across the elevation or the coronal view Cut Line Cut Line Press continue to see more examples. > Continue B Plane Uterus mid-transverse Volume Rendering Uterus mid-coronal Plane C Plane Uterus mid-coronal A Plane Uterus mid-sagittal A B VR C Once a 3D volume is acquired, the MPR images can be viewed. Each of the MPR planes are labeled as A, B, and C. These planes are represented as: the A plane is the acquisition plane. The B plane is 90 degrees to the A plane, and the C plane is 90 degrees to both the A and B planes. Each MPR and the VR have images stacked like pages in a book in front of and behind the displayed MPR images. These images can be paged through using each of the associated 3D control knobs on the control panel. MPR Overview Acquisition Direction Right Ovary Left Ovary 3D volume image of a phantom. Example of Image label icon for clear anatomy identification. To obtain a 3D or 4D volume image, position the 9VE4 transducer in the center of anatomy. Images are procured starting from the right of center ending to the left of center, (angle determines the width of volume). This is an automated process and provides Quantitative 3D volume data. Detailed anatomy icons are available for image labeling. Explore the Job Aids located in Resources for further instructions, or consult the User Manual for more detailed information. 9VE4 Transducer ? 9EC4 | New Transducer 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 The new 9EC4 transducer delivers excellent endo-cavity performance for the ACUSON Redwood system. Another feature of this transducer is the ability to produce a Freehand or a manually acquired 3D GYN volume data set. These volumes are rendered by manually rocking or pivoting the 9EC4 transducer across the anatomy of interest. Explore each of the numbers below for more information. This volume example was produced with a GYN phantom. 9EC4 / New Transducer Clinical Images 7 Rocked Timeline 5 As noted in the previous slide, the Rocked timeline is controlled by the Angle and Quality adjustments. Choosing a High setting under Quality control, adds time to the timeline. If a superior resolution is desired, but the timeline is more than needed, follow these instructions to adjust the acquisition time: Press the Start or Update key above the trackball to begin 3D acquisition Start a smooth, continual pivot or rocking motion of the transducer across anatomy If the sweep is completed before the timeline ends, press the Freeze control 3D volume data set will be available and ready to manipulate Press the Image button on the control panel to save the 3D data If reviewing a 3D volume at the end of exam or revisiting a study Activate Review > Press the 3D tab on the Touchscreen > use 3D Tools to manipulate volume > Image button is now available to acquire a single image of the volume and/or MPRs Freehand Sweep After pressing the Start key, pivot the transducer right-to-left for a sagittal acquisition. 6 Right-to-Left Click the image to play video. Image Icons After completing the 3D Setup and defining the anatomy of interest with the ROI, there are several icons on the image that assist with the acquisition. The Trackball icon identifies the Trackball action keys. As these keys are configurable and change during and after a 3D acquisition, it is a helpful reminder to refer to each key function. During acquisition the Rocked timeline shows the Angle of volume in degrees (or elevation) as well as the allotted time to acquire volume. 4 Continue to the number five slide to learn more on the Rocked timeline. Image Overlays Activation of the 3D/4D control displays an overlay on the image. Adjustments to these overlays define the 3D volume. Refer to the each label as they are identified on the image: Cut Line – defines the face of the volume. The volume of interest VOI, is indicated by the four green corner markers. Defining the depth of the VOI (anatomy between the Cut Line and bottom of VOI. The region of interest ROI (turquoise lines) identifies anatomy included within the volume, (top-to-bottom and side-to-side). 4 2 - VOI Cut Line ROI These image overlays are activated after 3D/4D control is triggered. 1- 3 - Press or tap the ROI to learn more. Touch Screen Setup Continued The volume size and resolution settings are displayed at the bottom right of the touchscreen, indicated by the yellow box. These controls are: Quality - changes the resolution of the volume and sweep duration Angle - determines the Angle or the width of the sweep. The sweep angle indicates the elevation of the 3D volume and corresponds to the MPR B plane. Reference the Job Aids in RESOURCES or the User Manual for more information on these controls. 3 Continue to number the four slide when finished with this slide. Touchscreen Setup Page Activation of the 3D/4D control allows the 3D/4D Setup page to be displayed on the touchscreen. Optimize the 3D acquisition before performing, let’s explore these options. Within the yellow box are these settings: Surface – displays varying opacities within the volume (this is the default setting) Min IP - minimum intensity projection, is best for viewing vascular structures Max IP - maximum intensity projection is optimal for viewing skeletal structures 2 Continue to the number three slide when review is finished. Getting Started The 3D option is only available in the GYN preset. When ready to acquire a 3D data set, press the 3D/4D control located on the control panel. (This control is viewed with the orange circle.) Press or tap the control panel image to continue. 1 VA2.0 improvements include upgraded report export, OB, and Early OB reporting. The addition of one week can now be added to the estimated due date (EDD) for better estimations. Click or tap the touch screen to review more reporting enhancements on the ACUSON Redwood system. ? Report Enhancements Report Enhancements Detailed Report can be stored or saved to a USB. Click or tap anywhere on the page to return to the main page or select Next to proceed. Back < Growth Percentiles are presented in an easy to read format. This Information may be stored to the Report or exported to USB. Click or tap the Print Preview highlighted in orange. Back < Store Report or Export to USB. Click or tap the Report key to view additional Exam Specific Information. Back < Ability to compare serial fetus reports in a side-by-side presentation. Click or tap the Print Preview highlighted in orange. Back < Check the selections to export either PDF, RTF, or both formats onto a USB. Select Close to proceed. Back < Pressing the Back < button will return to the previous sub-slide. Within the Report the user can select the Export key to choose report format types. Select Export highlighted with the orange box. ? Course Review Congratulations. You have completed this online course: ACUSON Redwood™ ultrasound system VB2.0, New Obstetric and Gynecology Features Select the numbered buttons below to review the material provided. Discuss new transducers and functionality 1 1 1 2 2 2 Review new reporting features Course Review New and Improved Reporting Addition of one week to EDD Easy customizations of what will be on Report Added new Percentiles Ability to compare up to four serial reports side-by-side Report export formats: PDF, RTF, or both formats onto USB Select the X in the upper right-hand corner to close this page. New Transducers 7VC2 Providing excellent imaging in ABD, OB, GYN, and General applications Providing an automated 3D and 4D acquisition One button push tools - Auto TEQ™ image optimization, Auto TEQ™ Doppler, eSieOB measurements and eSieScan™ workflow protocols 9VE4 Providing exceptional imaging presets in General, Early OB, and Gynecology Providing an automated 3D and 4D acquisition Many of the same one button push tools are available with this transducer as with the 7VC2 9EC4 A transitional endo-cavity transducer between Prostate and GYN applications Providing a Freehand style 3D acquisition in GYN preset All of the same 3D manipulations available Select the X in the upper right-hand corner to close this page and return to main page. Disclaimer Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. ACUSON Redwood™ ultrasound system, ACUSON Sequoia ™ ultrasound system, ACUSON Juniper™ ultrasound system , SieScape™ panoramic imaging, UltraArt ™, Auto TEQ™ image optimization, Auto TEQ™ Doppler, eSieScan™ workflow protocols is a trademark of Siemens Medical Solutions USA, Inc. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com ? Disclaimer Disclaimer Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the Online Training ACUSON Redwood™ Ultrasound System VA20 | Upgrade . Completion Navigation Help Select the icon on the upper left-hand side to open the table of contents. Select > Next to advance or review main pages using < Prev icons on the lower right-hand side of the slide. Exit this Navigation Help slide by selecting the . Click or tap to zoom images with the magnifying glass icon. Select the orange X in the upper right-hand corner to close subpages. Welcome Slide Question Bank 1 ACUSON Redwood™ Ultrasound / HOOD05162003237828 | Effective Date: 1, Dec. 2021 3D Controls Job Aid Freehand 3D Acquisition - Job AId 3D Three-dimensional 4D Four-dimensional CD Color Doppler CDV Color Doppler Velocity EDD Estimated Due Date GYN Gynocology MPR Multiplanar Rendering OB Obstetrics PDF Paperless Display Format or Portable Document Format PW Pulse Wave Doppler PWD Pulse Wave Doppler ROI Region of Interest RTF RIch Text Format SD Spectral Doppler USB Universal Serial Bus VOI Volume of Interest VR Volume Rendered 1.1 Welcome 1.2 ACUSON Redwood System 1.3 7VC2 | New Transducer 1.4 9VE4 | New Transducer 1.5 9EC4 / New Transducer 1.6 Report Enhancements 1.7 Course Review 1.8 Disclaimer 1.9 Completion
- 2D
- 3D
- 4D
- ACUSON
- Alphanumeric
- Annotation
- CEUS
- Contrast
- DICOM
- Doppler
- Echo
- Echocardiography
- Export
- Freehand
- Fetal Echo
- Gyn
- Keyboard
- MSK
- New Transducer
- NTSC
- Obstetrics
- OB
- PAL
- Retractable
- Rocking
- Small Parts
- Still Image
- Thyroid
- Ultrasound
- Upgrade
- Vascular
- Woman’s Health
- Freehand
- manual
- Redwood
- ultrasound OB/GYN
- EC
- endo-vaginal
- endo-cavity