ACUSON Redwood™ Ultrasound System Protocols
This quick reference guide helps you understand configuration of the protocol features on the ACUSON Redwood™ system.
ACUSON Redwood ultrasound system Protocols Quick Reference Card siemens-healthineers.com/ultrasound Step 1 – Open System Configuration menu Lock Screen Service Image Eject USB Configuration • Select the Additional Selections icon Network Job Status *= Storage Server • Select Configuration • Select Protocols from the Features drop-down menu K Features Tip: Change order of protocols or views using the arrowheads. Contrast Protocols K < > Step 2 – Add a Protocol Add Protocol Protocol Name CAROTID 2| • Select Add Protocol or, copy a factory default to use Copy Progression as a template O Automatic • Type in Protocol Name and then select: Manual Progression type Exit Protocol - Automatically exit protocol when all views completed Exit Protocol behavior - At Exit Protocol At Exit Protocol behavior O Remain in acquisition - Enter Report Enter Review SIEMENS Healthineers HOOD05162003029240 · 15-Oct-2019 Step 3 – Add a View View Body Markers & Text Measurements • Select the first view called User Defined and then type View Name Timer in View Name RT CCA PROX None • Select imaging modes for the view from Mode Mode Selection Display Format Selection None O Single Dual Live Dual 4B 2D • Select the available options for the selected mode (e.g., Display Format, Color type, color ROI Steer and Color Color Save Image with and Without Color are available Color CW O Color Power DTI when Color is selected) Color PW Steer Note: Select Add View to add additional views or, copy and edit an CW O None existing view PW Save Image With and Without Color PW DTI User Defined Add View Copy Step 4 – Add Body Markers & Text View Body Markers & Text Measurements • Select Body Markers & Text tab Text Text R Dist CCA • To add text, select Text and then enter desired text in the Text field • To change the Text Home location: Select the Home icon with arrows - Apply to All Views Select the new Home location in the Preview Screen - Body Marker Reselect the Home icon with arrows - Body Marker Package Select the Home icon Carotid Transducer Marker - If desired, select Apply to All Views after all views - have been created • To add body markers: Select Body Marker and then make a selection from - the Body Marker Package Select Transducer Marker - Select and drag widgets to adjust transducer - orientation and position Step 5 – Add up to 3 Measurements View Body Markers & Text Measurements • Select Measurements tab + • Select the + sign and then select: Measurement Package type CCA X + - Imaging Mode Measurement Package Carotid Search - Measurement label with corresponding Modifier Imaging Mode V CCA - and Segment 2D ICA M ECA Save Image With and Without Measurement, - Doppler Bulb if desired Modifier Segment Vert A Tip: eSie Measure is available for cardiac protocols. Right Prox Subclav A Left Mid Innom A [ Not Available ] . None Dist O None Save Image With and Without Measurement 2 siemens-healthineers.com/ultrasound HOOD05162003029240 · 15-Oct-2019 Import or Export Protocols and Offline Customization Import • To import or export protocols: Export Insert a USB drive and select Export or Import - Select target or source medium from Available Export - Media Select All Available Media [E:] (28.62 GB/28.63 GB) Select the required protocol(s) from the list Breast Breast - Cardiac Select Export Protocol or Import Protocol Cardiac - OB OB When progress bar is Done, select Close Carotid - Carotid Tip: Custom measurements must be present on any system the protocol is imported into. • Insert USB into a computer to perform offline protocol customization: Export Protocol Open the ExportOfflinePackage folder and then - select OfflineEditor 100.0% Create or modify protocols using the same interface Done - available on the ultrasound system and import back Close onto the system Note: Only run Protocol Offline Editor on Windows 10. ExportOfflinePackage OfflineEditor Workflow Tips • Activate a protocol by selecting it during patient Exam Workflow registration or by selecting Workflow > Protocols from the touch screen Protocols • Protocol views display on the touch screen and in the menu panel on the left side of the image screen • A view can be selected from the touch screen or by rotating the Forward / Backward control • To acquire a selected view, press Image or Clip on the control panel, a check mark displays on an acquired view • Automatic or Manual progression can be changed during an exam by pressing the Progression soft Progression Manual key control • Copy View, Rename View and Delete View are Rename View Delete View available on the soft key controls Copy View • Select Save Changes to apply changes Save Changes • Measurements are initiated by selecting Caliper on x ··· x the control panel Caliper • To add additional images, select Pause Protocol on touch screen or press Forward / Backward control Pause Protocol to pause protocol • Exit prompts the user if any of the configured views were not acquired and then exits the protocol Exit HOOD05162003029240 · 15-Oct-2019 siemens-healthineers.com/ultrasound 3 For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Redwood and eSie Measure are registered trademarks of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, siemens-healthineers.com USA Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · HOOD05162003029240 · 15-Oct-2019 · Order No. A91US-619-1C-4A00 · Printed in Germany · 7727 0520 ©Siemens Medical Solutions USA, Inc., 2020
- abdomen
- ARFI
- breast
- cardiac
- contrast
- connectivity
- echo
- cardiac strain
- elastography
- eSie Touch
- eSie Measure
- eSie Left Heart
- eSie OB
- eSie Follicle
- GYN
- early obstetrics
- intra-cavity
- renal
- pelvis
- point-of-care
- emergency medicine
- longitudinal strain
- LVO
- neonate
- musculoskeletal
- MSK
- Protocols
- OB
- strain
- stress echo
- small parts
- syngo Velocity Vector imaging
- testicular
- TEE
- trans-esophageal
- trans-vaginal
- trans-rectal
- vascular
- Virtual Touch technologies
- Virtual Touch software
- VVI
- gynecology
- VTq
- workflow