ACUSON Redwood™ Ultrasound System Quick Reference Guide
This quick reference guide is an overview of all the screen layouts and external features of the ACUSON Redwood™ ultrasound system. Included are steps for getting started beginning with patient registration and there is an overview of the 2D-mode, M-mode, color and spectral Doppler functionality, measurements, reporting, text, body markers, and arrows used for annotation. A quick reference covering the data and image management are included in this overview. Additionally, there is a review of the care and cleaning of your ACUSON Redwood system.
R Mid CCA ACUSON Redwood ultrasound system Quick Reference Guide Release 1.0 siemens-healthineers.com/ultrasound SIEMENS Healthineers HOOD05162003031820 15-Oct19 Introduction 2 At Siemens Healthineers, our purpose is to enable Table of content healthcare providers to increase value by empowering them on their journey towards expanding precision System Overview 3 medicine, transforming care delivery, and improving Getting Started 16 patient experience, all enabled by digitalizing 2D and M-mode 26 healthcare. Color and Spectral Doppler 44 Measurements and Reports 58 An estimated 5 million patients globally everyday Text, Body Markers and Arrows 68 benefit from our innovative technologies and services in the areas of diagnostic and therapeutic imaging, Data and Image Management 76 laboratory diagnostics and molecular medicine, Care and Cleaning 90 as well as digital health and enterprise services. We are a leading medical technology company with over 170 years of experience and 18,000 patents globally. With more than 48,000 dedicated colleagues in 75 countries, we will continue to innovate and shape the future of healthcare. HOOD05162003031820 15-Oct19 System Overview 3 1. Flat Panel Display Monitor 2. Touch Screen 1 3. Power On / Off (hibernation) 4. Control Panel (height and swivel adjustable) 2 5. 4 Transducer Ports 7 3 8 6. Transducer Connector Storage Bin 4 9 7. Rear Handle 8. Rear Storage Bin 9. Gel Warmer SIEMENS Healthineers 10. Swivel Wheels 5 11. Wheel Lock 6 CO 10 11 System Overview HOOD05162003031820 15-Oct19 System Overview 4 12. Articulating Arm (tilt, swivel) 13. 2 USB Ports 14. Optional Peripheral Box 16 (Printer, CD /DVD) or Storage 12 15. Air Filter 13 16. Document Sleeve 17. Transducer Holders 17 18. Cable Hanger 18 19. Non-imaging CW Pencil, ECG and 14 19 Aux ports 15 Healthingers'> HOOD05162003031820 15-Oct19 Power on and Hibernation mode 5 1. Press Power to turn the system on or to enter the System Shutdown 1 menu 2. Select Shutdown to turn the system off Update 3. Select Restar t to reboot the system ABC Image 4. Select Hibernate to enter Freeze hibernation mode which allows the system to power on in approximately 30 seconds System Shutdown A full Shutdown is recommended every 24 hours or 20 hibernates to maintain optimal performance. Hibernates Remaining: 20 4 3 2 Hibernate Restart Shutdown Cancel HOOD05162003031820 15-Oct19 System Overview System Overview 6 Connecting Transducer 1. Ensure the lever lock is in the left, unlocked position 3 1 2. Align the connector and press into the transducer port (an audible click ensures ED the transducer is connected) 2 3. Place the lever into the right, locked 10v position HOOD05162003031820 15-Oct19 Wheel Locks 7 1. Pressing the left green pedal places the wheel in a swivel locked position to enable steering 2. To lock the wheel, press the right red pedal 3. Press the gray pedal labeled OFF to align the pedals and unlock the wheels OFF OFF 3 OFF 2 1 HOOD05162003031820 15-Oct19 System Overview System Overview 8 Control Panel 1. Power 2. Soft Key Rotary Controls 1 2 3 3. DGC Controls CH 4. Contrast 4 5 6 7 8 9 10 Update 5. Virtual Touch Elastography 11 UD 12 x ... X Caliper 6. 3D / 4D (future use) Delete ABC Dual Image 7. M-mode 8. Pulsed Wave Doppler / Freeze Continuous Wave Doppler 9. Color Doppler 10. 2D Mode 11. User-defined Ke y 12. Depth / Focus HOOD05162003031820 15-Oct19 13. Forward / Backward Control 9 14. Delete 15. Text, Body Marker, Arrow 16. Caliper 18 Update 17. Left / Right Set Keys UD 16 X ... x 17 17 Caliper 20 18. Update Delete 15 19 ABC O 21 Dual Image 19. Trackball 13 14 23 24 TK 20. Clip Freeze 22 21. Image 22. Freeze 23. Dual 24. Zoom HOOD05162003031820 15-Oct19 System Overview System Overview 10 Monitor Screen Layout 1. Imaging Status Indicator 9. Focal Zone 2. Auto TEQ Indicator 10. Imaging Parameters 3. Orientation Marker 11. Depth Indicator 4. Patient Banner 12. Thumbnail Display 5. Image Display 13. User-defined Key Function 6. Status Icons 14. Trackball Functions 7. Image Screen Menu Panel 15. Print, Deselect, Delete Image 8. Measured Results (movable) HOOD05162003031820 15-Oct19 11 SIEMENS Healthineers ... 1 Frozen 4 2 6 Protocols 16. 10L4 Carotid 18.8 3 Carotid 5 TIB 2.40 R Bulb TIC 1.70 TIS 0.94 Bulb MI 0.29 R Prox ECA 19 fps T 98% R Prox ECA T 2D H Mid R Prox ECA 8 9 18.8 10 TEQ 0 dB ECA cmf Rt Prox Vert A RI DR 65 0.00 LD 2 R Prox ICA 7 T S/D 1.00 UA 2 PS 61.39 cm/s 3cm R Prox ICA 24 mm 60º C ED 61.39 cm/s Pen 11 12 R Prox ICA 80 3 dB PRF 1950 18 + ICA 60 General R Mid ICA PW -40 Low R Mid ICA -5 dB DR 70 dB R Mid ICA -20 PRF 3539 F 40 ICA cm/s GS 1.0 mm R Dist ICA T 20 19 R Dist ICA - 40 R Dist ICA Inverted 67.0 mm/s ICA R Ver A R Ver A T v R Ver A R Ver A Edit Vert A L Prox CCA 13 T UD Keyboard Set Set 15 6 / 18 14 HOOD05162003031820 15-Oct19 System Overview System Overview 12 Touch Screen Layout 1. Login Screen 11. User-defined Control 2. User Manual 12. Pointer 3. Imaging Modes 13. Additional Selections 4. Transducers 14. Previous Page 5. Add User-defined Exam 15. Rotary Soft Keys 6. Workflow Applications 16. Orange Background = Active Selection 7. Patient Registration 17. Gray Background with Boldface Type = 8. Review Available Selection 9. Report 18. Next Page 10. End Exam Note: The touch screen and soft key selections displayed here may not be the same selections that have been customized for your system. HOOD05162003031820 15-Oct19 13 1 2 4 5 6 5C1 18L6 10L4 Carotid 4V1 + Add Exam Workflow 3 E 7 Patient 2D 8 Review L/R Flip U/D Flip Biopsy L U Off Timer 9 Report 10 End Exam Change ROI Trapezoid 17 11 Live Dual 2 Auto TEQ 16 12 Harmonics Compounding 13 Clarify 15 Frequency Line Density DR Steer 14 H Mid 2 65 dB 18 Off -10 0 10 V HOOD05162003031820 15-Oct19 System Overview System Overview 14 Digital Keyboard To access, select Keyboard from the Additional UD Selections menu or, configure to User-defined key. Review Pointer Report HE Keyboard End Exam Screen Saver DVR Record/Pause Full Screen Hide Banner Lock Screen Service Image Network Job Send to Status Storage Server HOOD05162003031820 15-Oct19 15 A ? Patient Worklist Browser Review Patient # + New Patient Last Name First Name OK Cancel Review Patient ID E Report X @ # $ % & + 2 3 4 5 6 7 8 9 0 X Tab Q W E R T Y O P - C - Caps Lock A S D F G H J K L Enter Shift x C V B N M < > Del N Ctrl Alt INS Alt English HOOD05162003031820 15-Oct19 System Overview Getting Started 16 Patient Registration – Manual New Patient 1. Select Patient on the touch screen Patient 2. Enter patient information 3. Select Exam 4. Select OK Tip: Transducer, Exam and Protocol can be selected from the touch screen after patient registration. HOOD05162003031820 15-Oct19 17 New Patient Patient Demographics BE Last Name + Patient ID Height cm Weight kg 2 First Name Date of Birth Age Y BSA m2 Middle Name Pre Suf Gender Other Exam Exam Abdomen 3 Request ID Requested Procedure Protocol Accession No. Scheduled Procedure Indication Medical Information General OB GYN Vascular Urology BP Additional Information Order Information Performing Physician Referring Physician Operator 4 OK Cancel HOOD05162003031820 15-Oct19 Getting Started Getting Started 18 Patient Registration – Worklist 1. Select Patient on the touch screen Patient 2. Select Worklis t 3. Select Get Worklist 4. Select the desired patient or searc h by Name, Patient ID, Accession Number, etc. 5. Select OK System must be connected to a HIS / RIS server to access patient worklist - HOOD05162003031820 15-Oct19 19 Patient Registration 2 Worklist Local Patient List 3 Get Worklist New Patient Search within results 4 EE Patient Demographics Patient Name Patient ID Procedure Date, Time Accession ... Last Name Patient ID - Patient 63040207 Height cm Weight kg Mouse, Micky 76700 RequestedPr ... 7/9/2019 1:43 ... 20480643 First Name Name1 Date of Birth Age BSA m2 Patient, Nam ... 56509241 RequestedPr ... 7/9/2019 1:44 ... 21175836 Middle Name Pre Gender Patient, JUK ... 22416369 RequestedPr ... 7/9/2019 6:33 PM 23857566 Patient, Nam ... 63040207 RequestedPr ... 7/9/2019 1:44 ... 91615657 4 Exam Exam Request ID 9780439652353253 Requested Procedure Abdomen RequestedProcedureDescription Protocol Accession No. 91615657 Scheduled Procedure ScheduledProcedureStepDescription Indication Medical Information General OB GYN Vascular Urology BP O / 0 mmHg Additional Information Order Information Performing Physician Referring Physician Operator Status: Query succeeded. 5 OK Cancel HOOD05162003031820 15-Oct19 Getting Started Getting Started 20 Edit Study 1. Select Patient on the touch screen Patient 2. Select Edit on the image screen 3. Modify desired data fields 4. Select OK HOOD05162003031820 15-Oct19 21 Patient Registration Local Patient List New Patient Search within results Patient Demographics 3 EE Patient Name Patient ID Date of Birth Gender Last Name + Patient ID XXX Height cm Weight kg First Name Date of Birth Age BSA m2 Middle Name Pre Suf Gender Other Exam Exam Abdomen Rendestile Requested Procedure Accession No. Scheduled Procedure Indication Medical Information General OB GYN Vascular Urology BP Additional Information Order Information Performing Physician Referring Physician Operator 2 Edit 4 OK Cancel HOOD05162003031820 15-Oct19 Getting Started Getting Started 22 Transducer /Exam 1. Select the transducer on 1 A ? 5C1 1816 10L4 Breast 4V1 + Add Exam Workflow the touch screen = Patient Carotid 2. Select the desired Exam General Exit Review preset Abdomen Venous Edit Exam Report 2 End Exam Breast Arterial Thyroid Testis MSK HOOD05162003031820 15-Oct19 Store, Print, and Clip Store 23 1. Press Freeze 2. If desired, roll trackball for Update frame-by-frame CINE review x ... x 5 3. Press Image to save a static Caliper Clip image 4. Select the pointer on the 2 3 touch screen to select the ABC Image printer icon on the monitor to save and print* 5. Press Clip to acquire and 1 save a clip Freeze 0 / 35 *A compatible printer must Tip: Clip store length is adjustable 4 be connected and assigned on the touch screen during live to the print function in the scanning. configuration menu before using selection. HOOD05162003031820 15-Oct19 Getting Started Getting Started 24 Review and End Exam 1. Select Review Review A ? Patient Worklist Browser Review 2. Select the desired Patient General layout on the touch Review Layout 2 Select All Deselect All Archived Report screen Report 3. Rotate Pag e to move Show Selected Slide Show Stress Echo End Exam Review between images 4 Teaching File Export Change Order syngo VVI eSie LH 4. Select End Exam to end the study Delete PC Printer USB B/W Printer Left Margin Right Margin 3 Page Fr1 DICOM Printer Cine Fr1 1 of 1 Tip: The Forward / Backward control can also be used to navigate images in review. HOOD05162003031820 15-Oct19 25 Restart an Exam 1. Select Patient Patient Patient Browser on the touch Browser Search screen Worklist/MPPS Last Name Patient ID From 25/04/2019 - 25/04/2019 Query/Retrieve First Name Accession No. Date of Birth Gender Patient Clear Search 2. Select Browser Browser Network Job Status Study List Search within results Q on the touch DICOM Print Preview Patient Name Patient ID Date, Time H/ Size (MB) Archived 25_04_2019_14_48_43 25/04/2019 14:48 0/6 18.1 screen Source Media [D:] Local Disk 25_04_2019_14_20_08 25/04/2019 14:20 38 Available: 461.1GB/465.8GB 3 25_04_2019_11_41_11 25/04/2019 11:41 OVT6 25_04_2019_09_27_42 25/04/2019 09:27 Period 1/2 9 3. Select patient study Show All AAA 24_04_2019_18_10_47 24/04/2019 18:10 O/O 0.9 24_04_2019_15_47_56 24/04/2019 15:47 0/75 214.9 from list 24_04_2019_15_16_05 24/04/2019 15:16 0/38 106.5 0 8 24_04_2019_15_01_40 24/04/2019 15:01 4/2 37.7 4. Select Restar t stress, echo 3 24_04_2019_14_01_53 24/04/2019 14:01 O/O 0.9 STRESS, ECHO 24_04_2019_10_49_48 24/04/2019 10:49 0/0 04242019, 10031940 24_04_2019_09_03_07 24/04/2019 09:03 30/20 667.1 5. Select OK Total: 20 (20) Selected: 1 (47MB) Delete Export Output Device Send New Study Restart 0 / 16 4 Tip: Images, clips and volumes can be added to a closed study within 24 hours. HOOD05162003031820 15-Oct19 Getting Started 2D and M-mode 26 Control Panel Z Contrast VT 3D 4D M PW CW 2D Update UD Depth ! FocusC x ... x Caliper Clip Delete Dual Zoom ABC Image Freeze HOOD05162003031820 15-Oct19 2D Control Panel 27 2D Control Panel Controls Function Enters / exits 2D-mode or adjusts overall 2D gain / brightness 2D Rotate to adjust overall gain Note: Available on live or frozen image Manually adjusts gain / brightness at depth DGC Default all pods in the center, slide pod(s) after Auto TEQ is selected to increase / decrease brightness as needed Magnifies the image Rotate to increase or decrease image magnification Zoom Press to activate ROI (region of interest) for magnification and increased frame rate (HD Z) Note: Available on live or frozen image HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 28 2D Control Panel 2D Control Panel Controls Function Adjusts the scanning depth and the focal zone Depth / Focus Toggle up / down to adjust depth Rotate to adjust focal zone position Press to adjust the number of focal zones Displays two separately acquired images side by side Dual Press to activate and toggle between images Press 2D key to exit Increases the line density /frame rate Press Set key and roll trackball to resize 2D Sector Width Press Set key and roll trackball to position Press Set key to set Note: Not available on linear transducers HOOD05162003031820 15-Oct19 2D Touch Screen 29 A ? 18L6 14L5 10L4 Breast 5C1 + Add Exam Workflow Patient 2D Review L/R Flip U/D Flip Biopsy L U Off Timer Report End Exam Change ROI Speed of Sound 2 Trapezoid = Live Dual Auto TEQ 2 Harmonics Compounding Clarify Frequency Line Density DR Steer Off H Mid 2 65 dB -24 0 24 Note: The touch screen and soft key selections displayed here may not be the same selections that have been customized for your system. HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 30 UltraArt UltraArt allows the user to select preferred image parameter settings by choosing an image from several choices before they are applied. Select UltraArt to choose from available selections. 3 HOOD05162003031820 15-Oct19 2D Touch Screen 31 2D Controls Function Allows the user to select preferred image parameter settings by choosing an image from several choices before they are applied UltraArt Settings are Off, 1, 2, and 3 Note: Available on live or frozen image Increases contrast and lateral resolution, reduces noise and clutter Harmonics Select to activate / deactivate Enhances contrast resolution and boundary detection Compounding Select to activate / deactivate Adjust compounding level by rotating the Line Density soft key Displays linear or trapezoid image format Trapezoid Select to activate / deactivate Note: Available on linear transducers only HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 32 2D Touch Screen 2D Controls Function Activates two simultaneous images in dual format Live Dual Select to activate / deactivate Press C (color Doppler) to display color Doppler on one of the images Automatically and continuously optimizes gain, DGC and suppresses noise Auto TEQ in real time Select to activate / deactivate Adjusts orientation on the image screen U/D and R / L Flip Select to activate / deactivate Note: Available on live or frozen image Optimizes the 2D image by adjusting the speed of sound for fatty tissue Speed of Sound versus dense tissue in breast imaging Select to choose level Adjust the Speed of Sound levels based on the type of breast tissue HOOD05162003031820 15-Oct19 33 Selects the type and length of clip capture Clip Settings Chronology – prospective /retrospective, capture type, acquisition rate and trigger type Displays a count-up timer in the lower right corner of the imaging screen Timer Select to activate / deactivate Biopsy Enables biopsy needle guide function with angle selection Select to activate and choose from available angles (1–5, A & B) Image Size Adjusts the size of the displayed image on the monitor Select to choose size (1–5) Changes the active priority mode when in a combined mode Change ROI Select to change the active mode Note: Available on live or frozen image Displays four separately acquired images 4B Select to activate and add each image, select 2D to exit Note: Available in 2D and color Doppler only HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 34 Panoramic Imaging 1 1. Select Workflow A ? 5C1 18L6 10L4 14L5 Thyroid + Add Exam Workflow 2. Select Panoramic Panoramic Patient 2D Panoramic Review Flex Ruler Restore 7 Exit 3. Press Update key to Acquire Report acquire the image Best Fit 5 End Exam 4. Press Update key to Pause / Continue Pause / Continue; press End End right or left Set key to End the acquisition 6 5. Use Panoramic review controls after Cine completing the acquisition to size, rotate, pan, zoom or measure image 5 6. Use the Cine function to recall single Pan Pan Rotate Rotate frames for review 7. Select Exit to exit Panoramic imaging Tip: Available in power Doppler. HOOD05162003031820 15-Oct19 2D Soft Keys 35 2D Controls Function Balances between resolution and penetration Frequency Use higher frequency range for increased resolution Use lower frequency range to increase penetration Enhances contrast resolution and boundary detection Rotate to increase / decrease level of compounding when compounding is Line Density enabled Rotate to balance between resolution and frame rate when compounding is disabled Adjusts number of gray shades displayed DR Rotate clockwise for a softer/ grayer image (Dynamic Range) Rotate counterclockwise for more contrast Note: Available on live or frozen image HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 36 2D Soft Keys 2D Controls Function Clarify VE Decreases artifact, increases contrast resolution and boundary detection in structures with flow [Clarify vascular enhancement (VE) Press to activate / deactivate, rotate to select a setting technology] Select a higher setting to increase sensitivity, select a lower setting to decrease sensitivity Steers the field of view (FOV) Steer Rotate to steer left, center or right Note: Available on linear transducers only Adjusts the level of acoustic energy delivered to the patient Transmit Power Rotate to increase / decrease (applies to all active imaging modes) Note: Changes mechanical and thermal indices HOOD05162003031820 15-Oct19 37 Frame averaging – determines the number of frames combined into the final image Persist Rotate clockwise to increase frame averaging Rotate counterclockwise to demonstrate motion Selects a processing curve that assigns echo amplitudes to gray shades Maps Rotate to select desired Map Note: Available on live and frozen image Colorizes the gray-scale image Tint Rotate to select desired Tint Note: Available on live and frozen image HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 38 M-mode Control Panel Contrast VT 3D 4D M PW CW C 2D Update UD Depth FocusC x ... x Caliper Clip Delete Dual Zoom AB Image Freeze HOOD05162003031820 15-Oct19 M-mode Controls Function 39 Enters / exits M-mode or adjusts overall M-mode gain Press to activate / deactivate M (M-mode) Rotate to adjust overall M-mode gain Roll trackball to position M-line Note: Available on live and frozen image Enters / exits color M-mode Color M-mode With color Doppler (C) activated, press M (M-mode) Position M-line and Press M Press M to exit Update Alternates between M-mode sweep and 2D image Press to move between modes View the M-mode sweep based on patient anatomy, independent of Marker AMM (Anatomical M-mode) transducer orientation utilizing angle rotation Select right or left Set key to activate HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 40 M-mode Touch Screen A ? 5V1 Cardiac + Add Exam Workflow = Patient 2D M Physio Review Report End Exam E Change ROI Edge 2 Marker AMM Angle AMM = Harmonics Frequency Sweep Speed DR Angle H Mid 67.0 mm/s 65 dB Reset HOOD05162003031820 15-Oct19 M-mode Controls Function 41 Full Screen Trace / Split Screen Trace / Changes the M-mode display format Full Screen 2D Select the desired format to activate Increases contrast and lateral resolution, reduces noise and clutter Harmonics Select to activate / deactivate Edge Sharpens the appearance of the M-mode sweep Increase for more sharpness, decrease for less sharpness Change ROI Changes the active priority mode when in a combined mode Select to change the active mode Views the M-mode sweep based on patient anatomy, independent of Marker AMM (Anatomical M-mode) transducer orientation utilizing angle rotation Select to activate / deactivate Angle AMM Views the M-mode sweep based on patient anatomy, independent of (Anatomical M-mode) transducer orientation utilizing freehand drawing of the angle Select to activate / deactivate HOOD05162003031820 15-Oct19 2D & M-mode 2D and M-mode 42 M-mode Soft Keys M-mode Touch Screen Controls Function Balances between resolution and penetration Frequency Use higher frequency range for increased resolution Use lower frequency range to increase penetration Selects a processing curve that assigns echo amplitudes to gray shades in the M-mode sweep Map Rotate to select desired Map Note: Available on live and frozen image Colorizes the M-mode sweep Tint Rotate to select desired Tint Note: Available on live and frozen image HOOD05162003031820 15-Oct19 43 Adjusts the number of gray shades displayed in the M-mode sweep DR (Dynamic Range) Rotate clockwise for a softer/ grayer sweep Rotate counterclockwise for more contrast Note: Available on live or frozen image Adjusts the scrolling speed of the M-mode sweep Sweep Speed Increase to display fewer cardiac cycles Decrease to display more cardiac cycles Note: Available on live and frozen image Views the M-mode sweep based on patient anatomy, Angle independent of transducer orientation utilizing angle rotation Rotate to activate Anatomical M-mode and adjust angle Press to reset the adjusted angle HOOD05162003031820 15-Oct19 2D & M-mode Color and Spectral Doppler 44 Color Doppler Control Panel X Contrast VT 3D 4D M PW CW C 2D Update UD Depth x ... x FocusC Caliper Clip Delete AB Dual Zoom Image Freeze HOOD05162003031820 15-Oct19 Color Controls Function 45 Enters / exits color Doppler or adjusts overall color Doppler gain C (Color Doppler ) Press to activate / deactivate color Doppler mode Rotate to increase / decrease color Doppler gain Adjusts the color ROI Color Box Size / Increase frame rate by decreasing the color ROI width or depth Position Press right or left Set key to alternate between Size / Position Roll the trackball to resize or reposition color ROI HOOD05162003031820 15-Oct19 Color & Spectral Doppler Color and Spectral Doppler 46 Color Doppler Touch Screen A ? 4V1 5C1 + Add Exam Workflow Abdomen Patient 2D C Review L/R Flip U/D Flip Biopsy L U Off Report End Exam Change ROI Color Display Invert Live Dual Flow Dynamics General Color Power Filter Frequency Line Density Scale 3 Mid 2 1220 Hz V HOOD05162003031820 15-Oct19 Color Doppler Controls Function 47 Color (Doppler) and Alternates between Color and Power Doppler modes Power (Doppler) Select Color to apply colors based on velocity and direction of flow Select Power to apply colors based on flow amplitude Shows or hides color Doppler information in the region of interest Color Display Select to activate / deactivate Note: Available on live or frozen image Reverses colors depicting forward and reverse flow in ROI and color bar Invert Select to activate / deactivate Note: Available on live or frozen image Displays two live images side-by-side with and without color Doppler Live Dual Select to activate / deactivate Note: Available on live or frozen image Optimizes hemodynamic flow conditions Flow Dynamics Select from Low, General, High and a variety of anatomy specific settings (e.g., Kidney or Aorta) Changes the active priority mode when in a combined mode Change ROI Select to change the active mode Note: Available on live or frozen image HOOD05162003031820 15-Oct19 Color & Spectral Doppler Color and Spectral Doppler 48 Color Doppler Soft Keys Color Doppler Controls Function Adjusts the color wall filter Filter Increase to reduce motion artifacts Decrease to increase sensitivity to low flow states Adjusts the balance between line density and frame rate Line Density Rotate clockwise to increase line density and enhance resolution Rotate counterclockwise to decrease line density and increase frame rate Balances between resolution and penetration independent of the 2D Frequency frequency Use higher frequency range for increased resolution Use lower frequency range to increase penetration Adjusts the pulse repetition frequency (PRF) Scale Rotate clockwise to increase PRF Rotate counterclockwise to decrease PRF HOOD05162003031820 15-Oct19 49 Adjusts spatial averaging (smoothing) for color flow Smooth Increase for flow sensitivity Decrease for color spatial resolution Adjusts the range of flow velocities displayed above and below the baseline Baseline Rotate to adjust the baseline of the active mode Prioritizes the display of grayscale or color flow data Priority Increase for greater vessel color fill Decrease to prioritize grayscale and less vessel color fill Adjusts the time that the color flow data remains in the ROI before being Persist replaced by another color (Persistence) Increase for greater vessel color fill Decrease to increase temporal resolution Selects a processing curve that assigns the velocity / velocity variance (Color) or flow amplitudes (Power) to a range of colors Map Rotate to select desired Map Note: Available on live and frozen image HOOD05162003031820 15-Oct19 Color & Spectral Doppler Color and Spectral Doppler 50 Spectral Doppler Control Panel Z Contrast VT 3D 4D M PW CW C 2D Update UD Depth FocusC x ... x Caliper Clip Delete Dual Zoom AB Image Freeze HOOD05162003031820 15-Oct19 Spectral Doppler Controls Function 51 Enters / exits spectral Doppler or adjusts overall spectral Doppler gain PW (pulsed wave) Doppler Press to enter/ exit and CW (continuous wave) Roll trackball to position Doppler gate Doppler Press PW / CW to activate the strip Rotate PW / CW to adjust overall spectral Doppler gain Note: Available on live or frozen image Update Alternates between the Doppler spectrum and the 2D image Press to alternate between Doppler/ 2D HOOD05162003031820 15-Oct19 Color & Spectral Doppler Color and Spectral Doppler 52 Spectral Doppler Touch Screen A ? 4V1 5C1 + Add Exam Workflow Abdomen = Patient 2D P PW » Review Mute Volume 10 + Report Auto Trace End Exam E Change ROI Edge 2 Invert Triplex Med = PW CW Auto TEQ HPRF Gate Size Sweep Speed Baseline Scale Angle > 3.0 mm 50.0 mm/s 2450 Hz -60 0 60 HOOD05162003031820 15-Oct19 Spectral Doppler Controls Function 53 Allows the user to select preferred Doppler display settings UltraArt Settings are Off, Low, Medium, and High Full Screen Trace / Changes the spectral Doppler display format Split Screen Trace / Select the desired format to activate Full Screen 2D Note: Available on live or frozen image Reverses the Doppler spectrum (negative values display above the baseline) Invert Select to activate / deactivate Note: Available on live or frozen image Automatic tracing and display of PW Doppler measurements Select to activate / deactivate Auto Trace Select Direction of trace: above, below or on both sides of baseline Select Sensitivity of trace: lowest sensitivity 1 to highest sensitivity 8 Note: Available on live or frozen image Optimizes spectral Doppler gain, baseline, scale, dynamic range and Auto TEQ auto invert With Doppler spectrum active, select to activate / deactivate HOOD05162003031820 15-Oct19 Color & Spectral Doppler Color and Spectral Doppler 54 Spectral Doppler Touch Screen Spectral Doppler Controls Function Triplex Displays both the 2D image and spectral Doppler tracing in real-time Select to activate / deactivate Edge Sharpens the appearance of the Doppler sweep Increase for more sharpness, decrease for less sharpness Mutes or adjusts the volume of the Doppler function Mute, Volume Select to activate / deactivate Mute Press + or - to adjust volume level DTI (Doppler Tissue imaging Activates the Doppler Tissue imaging feature for cardiac exams capability) Select to activate / deactivate Changes the active priority mode when in a combined mode Change ROI Select to change the active mode Note: Available on live or frozen image HOOD05162003031820 15-Oct19 Spectral Doppler Soft Keys 55 Spectral Doppler Controls Function Adjusts sample volume size Gate Size Rotate clockwise to increase size Rotate counterclockwise to decrease size Adjusts the scrolling speed of the Doppler spectrum Sweep Speed Increase to display fewer cardiac cycles Decrease to display more cardiac cycles Note: Available on live and frozen image Adjusts the range of velocities displayed Baseline Rotate to adjust the baseline of the active mode Note: Available on live or frozen image Adjusts the pulse repetition frequency (PRF) Scale Rotate clockwise to increase PRF Rotate counterclockwise to decrease PRF HOOD05162003031820 15-Oct19 Color & Spectral Doppler Color and Spectral Doppler 56 Spectral Doppler Soft Keys Spectral Doppler Controls Function Adjusts the PW Doppler flow angle Angle Rotate to incrementally adjust the angle Press to cycle through -60 / 0 / 60 degree angles Adjusts the PW Doppler cursor angle Steer Rotate to incrementally adjust the angle Press to adjust the angle left, straight and right Note: Available only on linear transducers Balances between resolution and penetration independent of the 2D Frequency frequency or color frequency Use higher frequency range for increased resolution Use lower frequency range to increase penetration HOOD05162003031820 15-Oct19 57 Adjusts the spectral Doppler signal filter Filter Increase to reduce motion artifacts Decrease to increase sensitivity to low flow states Adjusts number of gray shades displayed DR Rotate clockwise for a softer/ grayer spectrum (Dynamic Range) Rotate counterclockwise for a blacker/whiter spectrum Note: Available on live or frozen image Selects a processing curve that assigns echo amplitudes to gray shades in the Doppler spectrum Map Rotate to select desired Map Note: Available on live and frozen image Colorizes the Doppler spectrum Tint Rotate to select desired Tint Note: Available on live and frozen image HOOD05162003031820 15-Oct19 Color & Spectral Doppler Measurements and Reports 58 Unlabeled Measurements Perform Measurements 1. Press Caliper x ... x Caliper 5. Roll the trackball to position the second 2. To change the measurement type choose caliper from the available displayed options or select 6. Press Set to complete the measurement More for additional measurement types 7. Roll the trackball to activate additional 3. Roll the trackball to position the first caliper caliper sets 4. Press Set to anchor Unlabeled measurements do not enter into Tip: Measurements can be performed on frozen, the exam report. CINE and stored images. HOOD05162003031820 15-Oct19 ? 59 Breast Testis Penile Thyroid Style1 Small Parts = = Patient Right Left None Review Avg. Rt Thyroid Vol Rt Thyro Distance Open Trace Open Spline 2 Distance Avg 3 Distance Avg Report V O A TI Rt Thyro ET-Stenosis Auto Stenosis D-Stenosis A-Stenosis Cross Angle End Exam Isthmus O d: D Ellipse Trace Spline eSieCalcs Hip Angle d:D Ratio Rt Parathyroid Rt Thyro V % IM Che Dist Ratio Vol Ratio Area Ratio Strain Ratio D-Vol Flow A-Vol Flow Vol 1 Dist Vol 2 Dist Vol 3 Dist 1 Ellipse Vol 1E + 1D Disk Trace Disk O Distance 2 ... Ellipse Spline Cross Angle Vol 3 Dist A-Stenosis Strain Ratio Shearwave ... 2 -- + More Clear Screen HOOD05162003031820 15-Oct19 Measurements & Reports Measurements and Reports 60 Labeled Measurements 1. Press Caliper x ... x Caliper 6. Press Set to complete the measurement, send the labeled value(s) to the patient report 2. Select the desired measurement label and / or activate additional measurements 3. Roll the trackball to position the first caliper 7. Select the exam type to display additional 4. Press Set to anchor labeled measurement packages 5. Roll the trackball to position the second caliper Tip: The measurement label can be selected before or after calipers are placed. HOOD05162003031820 15-Oct19 ? 61 Breast Testis Penile Thyroid Style2 Small Parts = 7 E Patient Rig General Abdominal Obstetrics Gynecology Small Parts Pediatric Review Rt Test Neonatal Vascular Urology Cardiac Musculoskeletal Report Rt Epididymis Rt Epididymis AP Rt Epididymis End Exam Length Width 2 Rt Testis Mass 1 Rt Testis Mass 1 Rt Testis Mass 1 Length AP Width O C Distance Ellipse Spline Cross Angle Vol 3 Dist A-Stenosis D-Vol Flow More Clear Screen HOOD05162003031820 15-Oct19 Measurements & Reports Measurements and Reports 62 Edit Measurements (Labeled and Unlabeled) Edit Completed Measurement 1. Press Update key to activate calipers and Edit cycle between active calipers for editing 2. Select Update and then select the Last Last Caliper Caliper soft key to cycle between caliper sets 3. Press Delete on the control panel to delete the active measurement 4. Select Clear Screen soft key to delete Clear Screen all measurements and annotations 5. Rotate Undo / Redo to edit a trace Undo/Redo measurement HOOD05162003031820 15-Oct19 Reposition Measurement Display Area (MDA) 63 Results 1. Select the pointer on the touch screen and then click on the MDA results (an orange outline appears around the MDA results) 2. Press and hold the Set key to “pick up” the MDA results 3. Drag the MDA results to the new location 4. Release the Set key to place the MDA results HOOD05162003031820 15-Oct19 Measurements & Reports Measurements and Reports 64 Report Review the Report 1. Select Report to enter/ exit report Report 5. Select Print Report to send to connected page external printer 2. Rotate Forward / Backward control 6. Select Print Preview to visualize the revised to scroll through the report summary 3. To edit the report, roll the trackball to the 7. Select Export PDF to save report to a USB desired measurement and edit 4. Select Store Report to capture the report as an image(s) Tip: To access the digital keyboard, select Only labeled measurements appear on Keyboard from the Additional Selections the report. An * appears for any edited menu or, configure to User-defined key. measurement. HOOD05162003031820 15-Oct19 65 Report Carotid ACUSON EL Exam Specific Information Carotid El Side-by-Side Label Method Value V1 V2 V3 V4 V5 Carotid Lt Prox CCA (PI) Carotid Assessment PI Last 1.56 1.56 RI Last 0.74 0.74 Images S/D Last 8.80 3.80 E Comments PS Last 67.71 cm/s 67.71 3 ED Last 17.84 cm/s 17.84 Lt Mid CCA (PI) PI Last 1.32 1.32 RI Last 0.66 0.66 S/D Last V 2.93 2.93 PS Last 71.36 cm/s 71.36 ED Last 24.33 cm/s 24.33 Rt Prox CCA (PI) PI Last 1.43 1.43 RI Last 0.68 0.68 S/D Last 3.16 3.16 PS Last 70.55 cm/s 70.55 ED Last 22.30 cm/s 22.30 6 Print Preview Print Report 5 4 Store Report Export PDF 7 HOOD05162003031820 15-Oct19 Measurements & Reports Measurements and Reports 66 Report Import Images into the Report 1. Select Report to enter/ exit report page Report 2. Select Images on Imaging Screen 3. Select the display format on the imaging screen 4. Roll the trackball to the thumbnail image and press the Set key to transfer to the images section 5. To delete the image from the report, place the cursor over image and click the “X” in Up to 20 images can be stored to the the upper right corner of the image Report. HOOD05162003031820 15-Oct19 67 Report Carotid ACUSON Exam Specific Information Images El Side-by-Side 3 2x2 Carotid 10L4 Carotid Caroud TIB 1.00 Carotid Assessment 11B 1.87 IIC 2.15 IIS 1.00 IIC 1.19 MI 0.95 IIS 0.40 MI 0.33 26 fps 26 fps Images 2 989 2D 2D H Mid TEQ OdB tcm 19 mm ho H Mid TEQ OdB E Comments DR 62 DR 62 LD 2 o'PI = 1,48 :120 LD 2 RI = 0.73 S/D = 3.69 -100 UA 2 Pen PS = 73.4 cm/s 6 dB ED - 19.9 cm/o PRF 2437 TAmax = 36.1 give 6 dB PRF 2437 4 General General PW Low 0dR DR 62 dB PRF 4550 F 68 GS 1.5 mm JIC2.13 IIS 0.70 MI 1.00 18 fps 98% 2D H Mid 2D TEQ 0 dB sem 19 mm (Y H Mid TEQ OdB DR 62 DR 62 LD 2 PI = 0.86 UA 2 RI = 0.55 2-120 C S/D = 2.22 Pen PS = 87.2 cm/a ED - 39.3 cm/o Per 6 dB PRF 2437 TAmax = 55.5 cm/o 6 de PRF 2437 General General PW Low OdB DR 62 dBy Print Preview Print Report Store Report Export PDF 014 HOOD05162003031820 15-Oct19 Measurements & Reports Text, Body Markers and Arrows 68 Text Touch Screen Layout • Text Replace Fields (1–4) A ? Text Body Marker Arrow Exam will replace the text when Thyroid = selecting different text from Patient Hide Words the same field on the same Review RIGHT SAG ISTHMUS SUP line LOBE Report LEFT TRV PARATHYROID MID NODE • Selecting choices from End Exam Additional Text (5) will add MIDLINE 2 THYROID INF 5 to the line of text rather 1 NECK MEDIAL than replacing text 3 LATERAL • To move the text, place the 4 cursor in the text and press Set K Clear Screen Delete Line Font Size Home Position Set Home W • The line of text becomes green and can be moved Text Replace (1–4) Additional Text anywhere on the Image Screen HOOD05162003031820 15-Oct19 Modifying Text From an 69 A ? Text Body Marker Arrow Exam Active Exam Thyroid Patient LEFT SAG THYROID | 4 Overwrite Hide Words 1. Select Review 1 Review RIGHT SAG ISTHMUS SUP LOBE 2. Select the desired image Report to display LEFT TRV PARATHYROID MID NODE End Exam 3. Press ABC MIDLINE THYROID INF ABC NECK MEDIAL 4. Select Overwrit e LATERAL 5. Enter the word over the area (the text will overwrite in a black box) < Clear Screen Delete Line Font Size Home Position Set Home W 6. To reposition the edited text, press Set key to activate the text 7. Press Image to save the modified text HOOD05162003031820 15-Oct19 Text, Body Markers & Arrows Text, Body Markers and Arrows 70 Text Icons Control Function Control Function Activates / deactivates text cursor Deletes one line of text at the Delete Line ABC and text touch screen menu cursor Sets default position for text Select Next Set Home Cycles through the text cursor Positions the cursor at the home Displays the next or previous Home Position location page, when available Hide Words Temporarily hides text Activates Caps Lock functionality Caps Lock on the digital QWERTY keyboard Deletes all text, pictograms or Clear Screen arrows Font Size Changes the font size of the text HOOD05162003031820 15-Oct19 Text 71 ? Text Body Marker Arrow 3 Exam Thyroid 1. Press the ABC key on Patient Hide Words 4 the control panel ABC Review SAG Select the desired RIGHT ISTHMUS SUP LOBE 2. Report 2 annotation on the touch LEFT TRV PARATHYROID MID NODE End Exam screen MIDLINE THYROID INF 3. Select the exam type t o NECK MEDIAL access text from a different LATERAL exam type 4. Select the Keyboard icon on the touch screen to < Clear Screen Delete Line Font Size Home Position Set Home > 3 activate / deactivate the digital QWERTY keyboard 5. Press Delete on the control panel to delete the active text HOOD05162003031820 15-Oct19 Text, Body Markers & Arrows Text, Body Markers and Arrows 72 Body Markers 1. Press the ABC key on the control panel ABC 2. Select the Body Marker tab 3. Select the desired Body Marker 4. Use the Body Marker widget on the touch screen to adjust transducer orientation / position 5. Press Set to anchor 6. Press the Trackball soft key on the Control Panel to toggle between Transducer Trackball Trackball Body Marker Transducer Marker Marker and Body Marker for repositioning 7. Press Delete on the control panel to delete the active Body Marker Tip: Body Marker options can be customized in the System Configuration Menu. HOOD05162003031820 15-Oct19 A ? Text 2 Arrow Exam 73 Body Marker Thyroid E Patient Review 4 Report D C End Exam one 3 6 Clear Screen Trackball Transducer Marker Rotate Marker Transducer Marker, On 300 HOOD05162003031820 15-Oct19 Text, Body Markers & Arrows Text, Body Markers and Arrows 74 Arrows 1. Press the ABC key on the control panel ABC 2. Select the Arrow tab on the touch screen 3. Select the desired arrow type / size / color 4. Use the Arrow widget or Rotate Arrow soft key to adjust arrow orientation 5. Roll the trackball to position 6. Press Set to add additional arrows Select Previous 7. Press Update to Select Previous arrow and cycle through multiple arrows Set Set 8. Press Delete on the control panel to delete the last arrow or Clear Screen to delete all Delete markings 9. Press ABC to exit Arrow function ABC Tip: Unlimited arrows can be added. HOOD05162003031820 15-Oct19 A 75 Text Body Marker Arrow 2 Patient Review 4 Report 77 End Exam 3 7 8 3 3 4 Clear Screen Arrow Color Arrow Size Rotate Arrow Green Large 300 HOOD05162003031820 15-Oct19 Text, Body Markers & Arrows Data and Image Management 76 Delete Images from a Current Study Delete Thumbnail Image 1. Select Pointer from the touch screen 2. Select an image on the thumbnail panel to highlight 3. Select Delete icon 4. Select OK Delete 1 selected clip(s), and/or image(s)? 4 OK Cancel 2 3 1713 HOOD05162003031820 15-Oct19 Delete Images in Review 77 1. Select Review on the touch screen Review 2. Select the desired layout on the touch screen Layout 3. Rotate the Page soft key to view more images Page 1 of 6 4. Select an image using the Pointer 5. Select Delete to delete the selected image Delete 6. Select Review or 2D to exit Review Review Tip: The Forward / Backward control can also be used to navigate images in review. HOOD05162003031820 15-Oct19 Data & Image Management Data and Image Management 78 Review Images from a Closed Study 1. Select Patient on the touch screen Patient 2. Select Browser on the touch screen or Imaging screen Browser 3. Double click the desired study 4. Select the desired display format on the Layout touch screen 5. Rotate the Page soft key to view more images Page 1 of 6 6. Select Review or 2D to exit Review Tip: The Forward / Backward control can also be used to navigate images in review. AV HOOD05162003031820 15-Oct19 79 Patient Browser 2 Browser Search Worklist/MPPS Last Name Patient ID From 25/04/2019 To 25/04/2019 Query/Retrieve First Name Accession No. Date of Birth Gender Patient Clear Search Network Job Status Study List Search within results Q DICOM Print Preview Patient Name Patient ID Date, Time / Size (MB) Archived 25_04_2019_17_11_29 25/04/2019 17:11 0/5 26.6 Source Media [D:] Local Disk 25_04_2019_16_47_38 25/04/2019 16:47 0/1 3. Available: 461.0GB/465.8GB 25_04_2019_16_22_26 25/04/2019 16:22 0/1 3.7 25_04_2019_15_08_31 25/04/2019 15:08 0/22 61.2 Period Show All 25_04_2019_15_06_40 25/04/2019 15:06 0/7 20.8 25_04_2019_15_05_10 25/04/2019 15:05 0/8 23.7 25_04_2019_15_03_54 25/04/2019 15:03 0/3 9.4 25_04_2019_15_01_37 25/04/2019 15:01 0/11 32.2 3 25_04_2019_14_59_16 25/04/2019 14:59 0/10 29.4 25_04_2019_14_57_12 25/04/2019 14:57 0/9 26.5 25_04_2019_14_48_43 25/04/2019 14:48 0/6 18.1 Total: 22 (24) Selected: 1 (29MB) Delete Export Output Device Send 0 / 10 New Study Restart HOOD05162003031820 15-Oct19 Data & Image Management Data and Image Management 80 Export to Network 1. Select single or multiple studies in the Browser 2. Select the target location from the Output Device 3. Select Send Tip: Images automatically send to PACS if the system is configured to send during the exam or at the end of the exam. HOOD05162003031820 15-Oct19 81 Patient Browser Browser Search Worklist/MPPS Last Name Patient ID From 25/04/2019 To 25/04/2019 Query/Retrieve First Name Accession No. Date of Birth Gender Patient Clear Search Network Job Status Study List Search within results Q DICOM Print Preview Patient Name Patient ID Date, Time /Size (MB) Archived 25_04_2019_15_03_54 25/04/2019 15:03 0/3 9.4 Source Media [D:] Local Disk 25_04_2019_15_01_37 25/04/2019 15:01 0/11 32.2 Available: 461.0GB/465.8GB 25_04_2019_14_59_16 25/04/2019 14:59 0/10 29.5 25_04_2019_14_57_12 25/04/2019 14:57 0/9 26.5 Period Show All 25_04_2019_14_48_43 25/04/2019 14:48 0/6 18.1 25_04_2019_14_20_08 25/04/2019 14:20 0/13 38.1 1 25_04_2019_11_41_11 25/04/2019 11:41 0/16 46.6 25_04_2019_09_27_42 25/04/2019 09:27 1/2 19 AAA, 24_04_2019_18_10_47 24/04/2019 18:10 0/0 0.9 24_04_2019_15_47_56 24/04/2019 15:47 0/75 214.9 24_04_2019_15_16_05 24/04/2019 15:16 0/38 106.5 Total: 22 (22) Selected: 1 (47MB) Delete Export Output Device 2 Send 3 0 / 16 New Study Restart HOOD05162003031820 15-Oct19 Data & Image Management Data and Image Management 82 Export Study to CD-R/DVD or USB 1. Insert CD-R/DVD or USB 6. Select Image Format (DICOM, TIFF/AVI, Select single or multiple studies in the or JPEG/AVI) 2. Browser 7. If desired, select De-identify to remove 3. Select Export patient data and rename study 4. Select Available Media target location 8. Select Export Select Data Export (Image or Study) 9. Upon completion, select Eject or select 5. Additional Selections icon and then select Eject USB HOOD05162003031820 15-Oct19 Search Export 83 Last Name Patient ID From 4 Available Media First Name Accession No. Date of Birth Gender E:] (Available: 28.6GB/28.6GB) Clear Search 5 Data Export Study Patient Name Patient ID Clips Images Size (MB) Study List Search within results Q Image Format 6 O 16 46.60 Patient Name Patient ID Date, Time % H/D Size (MB) Archived DICOM TIFFIAVI JPEG/AVI Identification 25_04_2019_15_03_54 25/04/2019 15:03 0/3 9.4 7 De-identify 25_04_2019_15_01_37 25/04/2019 15:01 0/11 32.2 Anonymous 25_04_2019_14_59_16 25/04/2019 14:59 0/10 29.5 CD/DVD Control 25_04_2019_14_57_12 25/04/2019 14:57 0/9 26.5 Finalize 25_04_2019_14_48_43 25/04/2019 14:48 0/6 Eject 9 18.1 Eject 25_04_2019_14_20_08 25/04/2019 14:20 0/13 38.1 Path siemenslexportimages 2 25_04_2019_11_41_11 25/04/2019 11:41 0/16 46.6 8 Export 25_04_2019_09_27_42 25/04/2019 09:27 1/2 9 AAA 24_04_2019_18_10_47 24/04/2019 18:10 0/0 0.9 0% 24_04_2019_15_47_56 24/04/2019 15:47 0/75 214.9 Ready 24_04_2019_15_16_05 24/04/2019 15:16 0/38 106.5 Close Total: 22 (22) Selected: 1 (47MB) Delete Export Output Device Send tal: 22 (22) Selected: 1 (47MB) Delete Export Output Device 3 New Study Restart HOOD05162003031820 15-Oct19 Data & Image Management Data and Image Management 84 Import from CD-R/DVD or USB 1. Insert CD-R/DVD or USB 2. Select Source Media in the Browser 3. Select single or multiple studies on the CD-R/DVD or USB 4. Select Import 5. Upon completion, select Additional Selections icon 6. Select Eject USB HOOD05162003031820 15-Oct19 85 Patient Browser Lock Screen E Service Image Eject USB 6 Browser Search Last Name Patient ID From TO Worklist/MPPS Network Job Send to Storage Server Query/Retrieve First Name Accession No. Date of Birth Gender Status 5 Patient Clear Search Network Job Status Study List Search within results Q DICOM Print Preview Patient Name Patient ID Date, Time H/D Size (MB) Archived 3 _001, 001_ 0/16 45.6 2 Source Media [E:] Available: 28.6GB/28.6GB Period Show All 4 Total: 1 (1) Selected: 1 (46MB) Delete Import Output Device Send New Study Restart HOOD05162003031820 15-Oct19 Data & Image Management Data and Image Management 86 Query /Retrieve from PACS 1. Select Query / Retrieve in the Browser 2. Select the desired server from the Server List 3. Enter the patient search parameters 4. Select Query 5. Select the desired study 6. Select Retrieve Tip: Enter multiple parameters for a targeted query. HOOD05162003031820 15-Oct19 87 Query/Retrieve Browser Query Study Information 1 Query/Retrieve Patient Last Name 3 Patient ID Referring Physician (Last Name) Study Description Abdomen Patient First Name Accession No. Referring Physician (First Name) Server List SYNGO 2 y US only From 09/07/2019 To 09/07/2019 Network Connection Clear Query 4 Echo SYNDYN1 Study List Status: TCP/IP - Successfully ping Patient Name Patient ID Date of Birth Gender Accession No. Date, Time 5 JUKNONAME, 09_07_2019_09_22_58 7/9/2019 9:22 AM O Series List Date, Time Modality Exam Series No. Images 7/9/2019 9:22 AM US 0001 O 7/9/2019 9:22 AM SR 0002 O 6 Retrieve Exit HOOD05162003031820 15-Oct19 Data & Image Management Data and Image Management 88 Teaching File 1. Select Patient Patient 6. To add selected images to an existing 2. Select Browser and double click teaching file, select the existing file desired study to review Browser and select Append 3. Press right or left Set key to 7. Select Close Select Select select desired image or clip Deselect Deselect 8. The teaching file is displayed in the 4. Select Teaching File on the Browser touch screen Teaching File 9. To add images from multiple studies, To add selected images to a follow steps 1–3, select the desired 5. new teaching file, enter a name teaching file and then select Append for the file and select Add to add the additional images Tip: Images and clips stored in teaching file removes all patient data. HOOD05162003031820 15-Oct19 Teaching File Patient Browser 89 Browser Search Teaching File Name Clips Images Worklist/MPPS Last Name Patient ID From 05/06/2019 TO ~05/06/2019 MY TEACHING FILE o First Name 00 Query/Retrieve Accession No. Date of Birth Gender Patient Clear Search Network Job Status Study List Search within results Q DICOM Print Preview Patient Name Patient ID Date, Time H/ Size (MB) Archived MY TEACHING FILE, 8 TF_20190605062853 05/06/2019 06:28 0/11 31.4 Source Media [D:] Local Disk 05_06_2019_06_22_02 05/06/2019 06:22 0/3 9.5 Available: 460.5GB/465.8GB 05_06_2019_05_09_45 05/06/2019 05:09 0/22 63.8 05_06_2019_02_34_15 05/06/2019 02:34 Period 0/65 186.5 Show All 6 Append 9 05_06_2019_01_37_56 05/06/2019 01:37 1/3 12.1 05_06_2019_01_25_02 05/06/2019 01:25 1/0 3,9 stress, echo 04_06_2019_08_15_43 04/06/2019 08:15 35/0 60.8 New Teaching File Name 5 Add 04_06_2019_00_57_15 04/06/2019 00:57 OFT 3.7 24_05_2019_09_06_52 24/05/2019 09:06 216 23.4 24_05_2019_08_08_50 24/05/2019 08:08 14/11 91.8 O 0% 24_05_2019_07_26_41 24/05/2019 07:26 9/11 81.3 Ready Total: 28 (31) Selected: 1 (31MB) Delete Export Output Device Send 7 Close New Study Restar HOOD05162003031820 15-Oct19 Data & Image Management Care and Cleaning 90 Cleaning and Disinfecting the System 1. Power off the system and unplug the power supply 2. Use a clean gauze pad or lint-free cloth, lightly moistened with a mild detergent, to wipe the surface of the system 3. Use a clean, lint-free cloth to dry the surface EE 4. As required, use an approved disinfectant wipe to disinfect the system and accessories 5. Plug the power cord into the power supply Tip: Ensure that fluids do not seep into any openings on the system. HOOD05162003031820 15-Oct19 Cleaning the Trackball 91 1. Rotate the ring around the trackball counter- clockwise and carefully lift the ring to remove Update 2. Remove the trackball 3. Clean the ring, trackball and trackball assembly with a cotton swab or lint-free pad moistened with a mild detergent solution 4. As required, use an approved disinfectant wipe to disinfect the ring, trackball and trackball assembly 5. After allowing the trackball components to completely dry place the trackball into the assembly 6. Place the ring over the trackball, aligning the tab with the point of attachment on the assembly, and rotate clockwise until the ring snaps into place HOOD05162003031820 15-Oct19 Care & Cleaning Care and Cleaning 92 Cleaning the Air Filter 1. Power off the system and unplug the power supply 2. Push the air filter tray to release the locking mechanism and then pull the tray from the system 3. Rinse the air filter tray with running water ACUSON Redwood and allow filter to completely dry 4. Slide the dry air filter back into the system 5. Plug the power cord into the power supply SIEMENS Healthineers Tip: Air filter should be checked and cleaned weekly to maintain proper system cooling. HOOD05162003031820 15-Oct19 93 HOOD05162003031820 15-Oct19 Care & Cleaning For the proper use of the software or hardware, please Certain products, product related claims or functionalities always use the Operator Manual or Instructions for Use (hereinafter collectively “Functionality”) may not (yet) be (hereinafter collectively “Operator Manual”) issued by commercially available in your country. Due to regulatory Siemens Healthineers. This material is to be used as training requirements, the future availability of said Functionalities material only and shall by no means substitute the Operator in any specific country is not guaranteed. Please contact Manual. Any material used in this training will not be your local Siemens Healthineers sales representative for the updated on a regular basis and does not necessarily reflect most current information. the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used The reproduction, transmission or distribution of this as your main reference, in particular for relevant safety training or its contents is not permitted without express information like warnings and cautions. written authority. Offenders will be liable for damages. ACUSON Redwood, Auto TEQ, Clarify, UltraArt, and Virtual All names and data of patients, parameters and Touch are trademarks of Siemens Medical Solutions, configuration dependent designations are fictional and USA, Inc. examples only. Note: Some functions shown in this material are optional All rights, including rights created by patent grant or and might not be part of your system. registration of a utility model or design, are reserved. Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, siemens-healthineers.com USA Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · HOOD05162003031820 ·15·Oct·19 · Order No. A91US-628-1C-4A00 · Printed in Germany · 7731 1119 ©Siemens Medical Solutions USA, Inc., 2019
- abdomen
- ARFI
- breast
- cardiac
- contrast
- connectivity
- echo
- cardiac strain
- elastography
- eSie Touch
- eSie Measure
- eSie Left Heart
- eSie OB
- eSie Follicle
- GYN
- early obstetrics
- intra-cavity
- renal
- pelvis
- point-of-care
- emergency medicine
- longitudinal strain
- LVO
- neonate
- musculoskeletal
- MSK
- Protocols
- OB
- strain
- stress echo
- small parts
- syngo Velocity Vector imaging
- testicular
- TEE
- trans-esophageal
- trans-vaginal
- trans-rectal
- vascular
- Virtual Touch technologies
- Virtual Touch software
- VVI
- gynecology
- VTq
- workflow