ACUSON Redwood™ Stress Echo Treadmill Continuous Capture w/o View Control
This quick reference guide helps you understand configuration of stress echo continuous capture with view control enabled on the ACUSON Redwood™ system.
ACUSON Redwood ultrasound system Stress echo treadmill continuous capture without view control Quick Reference Card siemens-healthineers.com/ultrasound Step 1 Configuration Step 3 • Review Stress Echo Configuration • Select the desired Stress Echo Protocol • Select New Patient H+ New Patient Pharmacology Treadmill Tip: Patient ID is required to begin an exam. Pharmacology Continuous ETreadmill Continuous Step 2 5V1 Bicycle Cardiac • Select the cardiac transducer Stress Echo ** Bicycle continuous • Select Stress Echo from the Workflow tab Step 4 • Region of interest (ROI) appears on the image • ROI position / size can be modified Tip: Select the left or right Set key to adjust Position Position position/ size. Size Size SIEMENS HOOD05612003045382 17-Oct-19 Healthineers 7640_US_ACUSON_Redwood_StressEcho_woViewControl_QuickCard_DD.indd 1 07.02.20 10:49 Step 5 Step 8 Select Select Rename View To begin acquisition of Deselect Deselect • • To select Post images, select Rename Rest images, select Clip View Store Rest 12 • Select one or multiple images to rename Select one or multiple View Acquired Selected • • Select the desired view name images by single-clicking V PLAX 4 • with the left/right Set key Select OK V PSAX 4 2 • Complete for all views • Double-click on the last V A4C 4 1 image selected Rename View A2C 0 Available Views O Tip: Selected images will have a green checkmark; PLAX PSAX A4C A2C images not selected will have a red X. The Navigation Panel displays how many Step 9 By View By Stage images have been acquired and selected • In Review Mode selected for each view. images can be viewed Sort By View Select Reject All to • acquire again for the Select Sort By View or By Stage current view if needed. • Compare option is available Step 6 PLAX Step 10 General Review • To capture Post images, select Clip Store PSAX • A General Review and Wall Motion Select Clip Store again to end acquisition Scoring (WMS) option is available Wall Motion • A4C Scoring • Pause Protocol if additional imaging outside of the protocol is needed A2C Step 11 Tip: In Post continuous capture without view End Protocol control, all images are acquired under Pause Protocol • Select End Protocol on the touch one view and renamed later. screen to end the stress protocol Step 7 Tip: Upon exit from the application, a standard imaging screen Select Mode will be displayed. If desired, capture non-stress images. • Once Post images are acquired, the application can be configured to enter Select Mode automatically For the proper use of the software or hardware, please always use the Operator available in your country. Due to regulatory requirements, the future Manual or Instructions for Use (hereinafter collectively “Operator Manual”) availability of said functionalities in any specific country is not guaranteed. issued by Siemens Healthineers. This material is to be used as training material Please contact your local Siemens Healthineers sales representative for the only and shall by no means substitute the Operator Manual. Any material used most current information. The reproduction, transmission or distribution of in this training will not be updated on a regular basis and does not necessarily this training or its contents is not permitted without express written authority. reflect the latest version of the software and hardware available at the time Offenders will be liable for damages. of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created Note: Some functions shown in this material are optional and might not be part by patent grant or registration of a utility model or design, are reserved. of your system. ACUSON Redwood is a registered trademark of Siemens Medical Solutions Certain products, product related claims or functionalities described in the USA, Inc. material (hereinafter collectively “Functionality”) may not (yet) be commercially Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, siemens-healthineers.com USA Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · HOOD05162003045490 17-Oct-19 Order No. A91US-614-1C-4A00 Printed in Germany · 7640 0220 · · ©Siemens Medical Solutions USA, Inc., 2020 7640_US_ACUSON_Redwood_StressEcho_woViewControl_QuickCard_DD.indd 2 07.02.20 10:49
- abdomen
- ARFI
- breast
- cardiac
- contrast
- connectivity
- echo
- cardiac strain
- elastography
- eSie Touch
- eSie Measure
- eSie Left Heart
- eSie OB
- eSie Follicle
- GYN
- early obstetrics
- intra-cavity
- renal
- pelvis
- point-of-care
- emergency medicine
- longitudinal strain
- LVO
- neonate
- musculoskeletal
- MSK
- Protocols
- OB
- strain
- stress echo
- small parts
- syngo Velocity Vector imaging
- testicular
- TEE
- trans-esophageal
- trans-vaginal
- trans-rectal
- vascular
- Virtual Touch technologies
- Virtual Touch software
- VVI
- gynecology
- VTq
- workflow