ACUSON Redwood™ Stress Echo Treadmill Continuous Capture w/ View Control
This quick reference guide helps you understand configuration of stress echo continuous capture with view control enabled on the ACUSON Redwood™ system.
ACUSON Redwood ultrasound system Stress echo treadmill continuous capture with view control Quick Reference Card siemens-healthineers.com/ultrasound Step 1 Configuration Step 3 • Review Stress Echo Configuration • Select the desired Stress Echo Protocol • Select New Patient H+ New Patient Pharmacology Treadmill Tip: Patient ID is required to begin an exam. Pharmacology Continuous ETreadmill Continuous Step 2 5V1 Bicycle Cardiac • Select the cardiac transducer Stress Echo ** Bicycle continuous • Select Stress Echo from the Workflow tab Step 4 • Region of interest (ROI) appears on the image • ROI position / size can be modified Tip: Select the left or right Set key to adjust Position Position position/ size. Size Size SIEMENS Healthineers HOOD05162003044966 15-Oct-2019 7639_US_ACUSON_Redwood_StressEcho_wViewControl_QuickCard_DD.indd 1 07.02.20 10:19 Step 5 Step 7 Select Select Pause Protocol To begin acquisition of Deselect Deselect • • To end capture, select Clip Store on Rest images, select Clip the final view Select Mode Store Rest 12 • Pause Protocol if additional imaging View Acquired Selected • Select one or multiple outside of the protocol is needed images by single-clicking V PLAX 4 • Once Post images are acquired, the with the left/right Set key V PSAX 4 2 application can be configured to enter • Double-click on the last V A4C 4 1 Select Mode image selected A2C 0 0 Tip: Selected images will Step 8 have a green checkmark; images not selected will • To select Post images, use the left or right Set key to have a red X. select images The Navigation Panel • displays how many Once selected, the image will have a green check mark images have been • Repeat until all desired Post images are selected acquired and selected for each view. Select Reject All to Step 9 By View By Stage acquire again for the current view if needed. • In Review Mode selected images can be viewed Sort By View Step 6 (View Control) Select Sort By View or By Stage PLAX • • Compare option is available • To capture Post images, select Clip Store PSAX • Select Clip Store again to end acquisition for current view Step 10 A4C General Review • Select Clip Store to begin acquisition for • A General Review and Wall Motion A2C the next view Scoring (WMS) option is available Wall Motion Scoring • Repeat for all views Tip: A guide on the touch screen displays Step 11 current view highlighted orange. End Protocol • Select End Protocol on the touch screen to end the stress protocol Tip: Upon exit from the application, a standard imaging screen will be displayed. If desired, capture non-stress images. For the proper use of the software or hardware, please always use the Operator available in your country. Due to regulatory requirements, the future Manual or Instructions for Use (hereinafter collectively “Operator Manual”) availability of said functionalities in any specific country is not guaranteed. issued by Siemens Healthineers. This material is to be used as training material Please contact your local Siemens Healthineers sales representative for the only and shall by no means substitute the Operator Manual. Any material used most current information. The reproduction, transmission or distribution of in this training will not be updated on a regular basis and does not necessarily this training or its contents is not permitted without express written authority. reflect the latest version of the software and hardware available at the time Offenders will be liable for damages. of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created Note: Some functions shown in this material are optional and might not be part by patent grant or registration of a utility model or design, are reserved. of your system. ACUSON Redwood is a registered trademark of Siemens Medical Solutions Certain products, product related claims or functionalities described in the USA, Inc. material (hereinafter collectively “Functionality”) may not (yet) be commercially Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, siemens-healthineers.com USA Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · HOOD05162003044966 15-Oct-19 Order No. A91US-613-1C-4A00 Printed in Germany 7639 0220 · · · ©Siemens Medical Solutions USA, Inc., 2020 7639_US_ACUSON_Redwood_StressEcho_wViewControl_QuickCard_DD.indd 2 07.02.20 10:19
- abdomen
- ARFI
- breast
- cardiac
- contrast
- connectivity
- echo
- cardiac strain
- elastography
- eSie Touch
- eSie Measure
- eSie Left Heart
- eSie OB
- eSie Follicle
- GYN
- early obstetrics
- intra-cavity
- renal
- pelvis
- point-of-care
- emergency medicine
- longitudinal strain
- LVO
- neonate
- musculoskeletal
- MSK
- Protocols
- OB
- strain
- stress echo
- small parts
- syngo Velocity Vector imaging
- testicular
- TEE
- trans-esophageal
- trans-vaginal
- trans-rectal
- vascular
- Virtual Touch technologies
- Virtual Touch software
- VVI
- gynecology
- VTq
- workflow