Acuson S Family Correcting Patient Data
Acuson S Family Correcting Patient Data
ACUSON S Family™ Ultrasound System Correcting Patient Data 1. Enter Patient Browser. Click on Local Database. Patient Local Database Browser Scheduler F2 CD-R 2. Select the Patient Exam that was completed under the incorrect patient name. OB PATIENT // / DONE Unknown // / DONE Local Database Unknown Breast 11 / DONE /1 / DONE II I COMLOC 3. Click on Patient drop-down menu and select De-Identify. Patient Browser Patient Transfer Ed Load To Review De-Identify Upload to Siemens Film Task Status ... Expose Film Task Ctrl+P Copy to Film Sheet Num Enter Show MPPS Print Freview Print List Phat Search Search Selected .. Close Browser Alt+F4 SIEMENS www.usa.siemens.com/healthcare Page 1 of 4 4. The Dummy Name Box will appear, select OK. There is no need to enter in a name at this point. De Identify Dummy Name OK Cancel 5. Wait for a new exam to appear in the local database named Anonymous Patient and select this folder. Scheduler TEST, TEST CDA 57000 OPT CLASS $2000 OPT CLASS 6. From the Edit menu at the top of screen, select Correct. Edit View Filter Sort Options Cut Ctrl+X Paste Ctrity Delete Del Modify Patient Groups Protect Remove Protection Mark Num 3 Unmark Correct History Set State SIEMENS www.usa.siemens.com/healthcare Page 2 of 4 7. Select Yes to bypass the warning prompts. Confirmation for Warning(s) The following warning was detected during checking the affected data: Non-local data involved Details Do you really want to continue? Yes No Help 8. This will lead you to a screen in which you can change all of the Patient’s Data. You will now need to be sure to manually type in all of the following: LAST NAME, MIDDLE NAME (if patient has one on the order) FIRST NAME, DATE OF BIRTH SEX, PATIENT ID ACCESSION NUMBER, EXAM TYPE Modifier's Name meduser Lastname TEST First name SEMENS PaterID 123456 Mode name Pirtient Titia Referring physician Suffix Admission ID Other Patients name[s] Other PatertiD[s] Ethnic group Accession No Mitary tank Date of birth 1/1/1950 Sex Male Series description Female . Not se Series data 2/26/2014 Height Weight Adsoonal info Number Comment . OK Cancel Heb 9. Once this information is entered, select OK from the bottom. Modifier's Name meduser Lastname TEST First name SEMENS PaterID 123456 Miode name Pintient Title Referring physician Suffix Adrmission ID Other Patients name[s] Other PatertiD[s] Ethnic group Accession No Mitary tank Date of birth 1/1/1950 Sex Male Female . Other Series description . Not set Series date 2/26/2014 Height Weight Addeional info Number Comment . OK Cancel Heb SIEMENS www.usa.siemens.com/healthcare Page 3 of 4 10. Manually send this corrected exam to PACS from the local database. After confirming the exam is in PACS under the proper name, delete the exam done with the incorrect Patient Name from the System. 11. Note: Once complete, the individual images from the corrected exam will not have the patient’s HIPPA information on top. However, the folder itself will obtain all of the correct information in the PACS. SIEMENS www.usa.siemens.com/healthcare Page 4 of 4
- s2000
- s3000