PEPconnect

ACUSON S2000 ABVS Transducer Quick Card

Siemens Healthineers Ultrasound transducers and technology empower you to capture clear, beautiful clinical images. Taking care of your investment will help to maximize your transducer’s performance and product life. The information contained in this document provides you with approved cleaners and disinfectants to help maintain your transducers.
 

ACUSON S2000 Automated Breast Volume Scanner (ABVS) Transducer Care Quick Card Siemens Healthineers Ultrasound transducers and technology empower you to capture clear, beautiful clinical images. Taking care of your investment will help to maximize your transducer’s performance and product life. The information contained in this document provides you with approved cleaners and disinfectants to help maintain your transducers. General Handling of Siemens Healthineers Transducers  Take extreme care when handling or storing transducers. They must not be dropped, jarred, or knocked against other objects. Do not allow transducers to come into contact with any sharp- edged or pointed object. Careless handling can result in damage to acoustic lens, housing, cable and/or system connector. Never use transducers with cracked or damaged housings, acoustic lens, strain relief or cable assemblies as these issues may increase cross- contamination risks and compromise electrical safety features of the transducer.  The transducers have been designed and tested to be able to withstand high-level disinfection as recommended by the manufacturers of the Siemens Healthineers approved disinfectant products. Carefully follow the disinfectant manufacturer's instructions for use. Do not immerse for more than one hour.  Do not sterilize transducers using hot steam, cold gas, or Ethylene Oxide (EO) methods. Before applying any other methods that might be recommended by manufacturers of sterilization equipment, please contact your Siemens Healthineers representative.  Do not use abrasive cleaning agents, organic solvents such as benzene, isopropyl alcohol, or phenol-based substances, or cleaning agents containing organic solvents to clean or disinfect transducers. Use of these substances can damage the transducer and diminish image quality. For more Transducer Care information and a list of approved cleaners & disinfectants visit usa.healthcare.siemens.com, or ask your Siemens Clinical Specialist for more details. siemens.com/healthineers SIEMENS HOOD05162003003834 · Effective Date: 4-16-2019 Healthineers ACUSON S2000 ABVS System 14L5BV Transducer The ACUSON S2000 ABVS system can be utilized to perform handheld 2D and 3D ultrasound. There are 4 handheld transducers for breast imaging: 18L6 HD, 14L5, 12L4, 9L4. The ABVS transducer pod utilizes the 14L5BV transducer for automated 3D imaging.  Transducer offers multiple ed Bre ON A frequencies (14 – 5 MHz)  Features a 154 mm x 168 mm Field of View SIEMENS  Single-use pod screens help maintain breast contact throughout the exam ..........................  The compression button  provides additional tissue The lock / unlock stabilization in order to button provides ensure optimal image stabilization against the acquisition. breast for image optimization and allows for an  ergonomic “hands free” scan approach. SIEMENS © Siemens Medical Solutions USA, Inc., 2019 Healthineers HOOD05162003003834 · Effective Date: 4-16-2019

  • ACUSON S2000 ABVS Transducer Quick Card