ACUSON SC2000™ Volume Imaging Ultrasound System – eSie LVA
This is a step by step job aid reviewing the steps of performing eSie Left Ventricular Analysis on the SC2000.
Job Aid | ACUSON SC2000™ Volume Imaging Ultrasound System – eSie LVA Effective Date: 03/27/2019 | HOOD05162003001016 ACUSON SC2000™ Volume Imaging Ultrasound System – eSie LVA Ultrasound: Cardiology 1. Using the 4Z1c volume transducer, optimize the left ventricle view to ensure that the entire ventricle is seen in all three reference planes. Acquire up to 3 cardiac cycles with at least 16 volumes per second (VPS). 53 bpm / NTHI General -4D --- H2.8MHZ 7 dB TEQ: 1 / Offset: 0 dB DR: 65 dB 47 The system will use the last 3 beats acquired unless you freeze first and scroll to the desired set up beats Volumes can be acquired without an EKG using time capture o By deflault, the last 330 frames will be loaded into the LVA application Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162003001016 SIEMENS Jobaid: Effective Date: 03/27/2019 | HOOD/HILS Healthineers Job Aid | ACUSON SC2000™ Volume Imaging Ultrasound System – eSie LVA Effective Date: 03/27/2019 | HOOD05162003001016 ** Tips for increasing VPS: Narrow sector size Decrease depth to focus on LV Set space time setting to T1 (default is S1) Non harmonic 2.8Mhz (default is harmonic H2.8Mhz) Use SieShell to quickly view the both halves of the LV to verify no part of it is out of the volume pyramid Cardiac / 4216 26 vps / 170 mm 67 bpm / NTHI General -4D- 2.8MHZ 5 de DR: 60 GB 4 1 27 2. To launch eSie LVA, right click on the the thumbnail or right click on the image from Review 3. Analysis and quantification takes about 10 seconds for a single cardiac cycle , and longer for multiple cycles 4. LV volume cast, volume curves, segments, contours, and indices will appear Average EF 65.74 % EDV 178.96 ml ESV 61.33 ml SV 117.64 ml 17 Segment Model Volume 10 Inf 5. Results will default to averaged if multiple beats were analyzed Click on the arrow to see the results for each individual beat X 6. Clip store and/or image store any of the results pages Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162003001016 SIEMENS Jobaid: Effective Date: 03/27/2019 | HOOD/HILS Healthineers Job Aid | ACUSON SC2000™ Volume Imaging Ultrasound System – eSie LVA Effective Date: 03/27/2019 | HOOD05162003001016 7. To edit: click on Edit Curves to change the contour *** If extensive editing is needed, it is recommended that a new image is analyzed *** Edit contours one beat at a time on a multibeat acquisition Edit contours in both ED and ES on each beat o Use soft keys to quickly go to ED or ES providing an EKG is present Click on “Track all adjacent frames” icon Click on “Track on all frames” icon Click on LV analysis to accept contour changes Results can be exported to the report (first icon) and/or USB (second icon) LVA indices will populate on the report under the section labled LVA and RVA and can be edited o The EF from LVA will not be averaged with any other EF obtained during exam Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162003001016 SIEMENS Jobaid: Effective Date: 03/27/2019 | HOOD/HILS Healthineers Job Aid | ACUSON SC2000™ Volume Imaging Ultrasound System – eSie LVA Effective Date: 03/27/2019 | HOOD05162003001016 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserv ed. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162003001016 SIEMENS Jobaid: Effective Date: 03/27/2019 | HOOD/HILS Healthineers
- ACUSON SC2000™ Volume Imaging Ultrasound System – eSie LVA