ACUSON SC2000™ Volume Imaging Ultrasound System – Stress Echo with View Control
This is a step by step job aid reviewing the process of performing a stress echo on the SC2000 while using View Control
ACUSON SC2000™ Volume Imaging Ultrasound System - Stress Echo with View Control Ultrasound: Cardiology 1. Start a new patient. Under cardiac workflow, select your customized exercise or dobutamine protocol. Click OK to begin imaging. Workflow Cardiac Cardiac Limited Adult Echo Complete Adult Echo Volume Adult Echo 4D Pharm Stress 4-Stage 2D Exercise Stress 2-Stage 2D Pharm Stress 4-Stage 2. Connect your treadmill ECG slave cable and change Physio F13 to AUX if applicable. Physio F13 3. Orientation note* Right sided interface is for acquiring images, Left sided interface is for se- lecting and shuffling images. 4. When you are ready to begin the stress protocol, click on resume protocol in the upper right corner task pane. (A fixed region of interest will appear.) X eSieScan Protocol 2D Exercise Stress 2-Stage Resume Protocol Rest Post SIEMENS siemens.com/healthineers Healthineers . Job Aid | ACUSON SC2000M Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 5. A green arrow will appear next to the active stage and active view name. Post A4C (2D) A2C (2D) PLAX (2D) PSAX (2D) Accept Stage Resume Capture End Capture 6. Press clip store to begin acquisition of the configured number of clips Gan Clip Store RES DVR Siemens Healthineers Services Page 2 of 9 Job Aid | ACUSON SC2000TM Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 7. Images will automatically appear for selection. To select, single click on the desired view; a blue square will frame the image of the selected view. To unselect simply single click on the image again. To recapture, single click on the view name on the right-sided interface. (Note: New images will replace previously acquired images!) 8. After all views have been acquired and selected for a given stage, you may single click on stress review to see the selected images. CVA 9. To start the next stage, single click on the right side of the screen on the next stage. If appli- cable a timer will start. 2D Exercise Stress 2-Stage Pause Protocol Rest ¥>PLAX (2) >PSAX (2D) ¥>A4C(2) >A2C (2) Accept Stage Post Siemens Healthineers Services Page 3 of 9 Job Aid | ACUSON SC2000M Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 10. Press clip store to begin your continuous acquisition and acquire all of your post images. Press clip store again to stop/pause acquisition. Clip Store RES DVR Ap 11. Use the scroll wheel at home base to advance through all of the images. A green arrow will appear next to the active image. (Note: Baseline parameters are applied uniquely for each view.) Y Post V A4C (2D) A2C (2D) PLAX (2D) PSAX (2D) 12. Press clip store again to stop/pause acquisition Gain Clip Store RES DVR 211 Siemens Healthineers Services Page 4 of 9 Job Aid | ACUSON SC2000M Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 13. A progress bar will appear on the right side task pane of show available capture space. SieScan Protocol 2D Exercise Stress 2-Stage Pause Protocol Rest Post A4C (2D) A2C (2D) PLAX (2D) PSAX (2D) Accept Stage. 5 % Pause Capture End Capture 14. When you are finished capturing, press select to disengage ROI. 15. Select End Capture on the right hand task pane to be put into review/selection mode. eSieScan Protocol 2D Exercise Stress 2-Stage Pause Protocol › Rest Post A4C (2D) A2C (2D) PLAX (2D) PSAX (2D) Accept Stage 5 % Pause Capture End Capture Siemens Healthineers Services Page 5 of 9 Job Aid | ACUSON SC2000M Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 16. Select view name from the menu to review images captured. Stress Echo Selection Page 12 of 26 Stage Post ¥ AAC 2 AZC PLAX PSAX 17. Point and left click to select image, right click on this image to label it with the appropriate view name. (Multiple post images can be selected per view if desired.) 18. On the left task panel, click each View name to automatically move to the first post images captured of each view. Use the Page control to move through the remaining images of each view. Using the Select key, choose the images to be saved. A checkmark will appear beside the view name once the image(s) have been selected. View names can be changed by pressing the Next key (right click) for a menu of view names Stress Echo Selection Page 22 of 26 Stage Post ¥ A4C A2C PLAX PSAX Siemens Healthineers Services Page 6 of 9 Job Aid | ACUSON SC2000M Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 19. Select all post images then Stress Review Viewing options include: 1. Hide/show overlays. Stress Echo 2. Viewing layouts. Selection 1only, 1X1, 2X2, 4X2, 4X3 Stress Review 3. Sort Page Sort by stage 1 of 1 Sort by view 2 4. Playback Mode. Sort Full R-R Sort By Stage Systole only 3 Diastole only Playback Mode 4 Full R-R 5. Brightness and contrast. Brightness 50 of 100 Contrast 50 of 100 5 20. The left hand menu will allow you to view images by view or stage and also let you change playback mode. If multiple images were selected per view, click on the dog ear in the upper right corner of the images to cycle through selections. 2D Pharm Stress 4-Stage Baseline 10:16:39 Peak 10:26:46 PLAX 50 FPS FLAX 50 FPS 66 BPM 00:01:03 72 BPM MI: 0.9 MI: 0.9 Acquisition Stress Echo Stress Review Page 1 of 1 Sort Sort By Stage Playback Mode Full R-R Brightness 50 of 100 Contrast 50 of 100 1:70 1:70 Baseline 10:19:59 Peak 10:27:28 MC 45 FPS 1/2 MC 45 FPS Review 72 BPM 00:01:45 69 BPM MI: 1.0 MI: 1.0 LVA RVA Siemens Healthineers Services Page 7 of 9 Job Aid | ACUSON SC2000M Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 21. Press the check mark on left hand side to close exam. Stress Echo Review 22. Helpful Hints: At anytime during the stress exam, you can pause the protocol by selecting Pause Proto- col on the right hand task pane. To make a measurement, point and left click on the image you wish to measure. Pause playback then press the Measure Key on the keyboard. Two timers are available and can be displayed in review. The first timer starts as soon as Accept Stage is pressed. The other timer is activated manually and is located in the lower left hand portion of the screen. Do not use scroll wheel to change pages. Use menu knob or page up/down keys on key- board. Siemens Healthineers Services Page 8 of 9 Job Aid | ACUSON SC2000M Ultrasound System -Stress Echo with View Control Effective Date: 09/08/2016 | Quality 650 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 9 of 9
- ACUSON SC2000™ Volume Imaging Ultrasound System – Stress Echo with View Control