ACUSON SC2000™ Volume Imaging Ultrasound System – Stress Echo without View Control
This is a step by step job aid that reviews the steps and process of performing a stress echo on the SC200 without using View Control
ACUSON SC2000™ Volume Imaging Ultrasound System – Stress Echo without View Control Ultrasound: Cardiology 1. Start a new patient. On the Workflow menu, select your customized exercise or dobutamine protocol. Click OK to begin imaging. Workflow Cardiac Cardiac Limited Adult Echo Complete Adult Echo Volume Adult Echo 4D Pharm Stress 4-Stage 2D Exercise Stress 2-Stage 2D Pharm Stress 4-Stage 2. Connect your treadmill ECG slave cable. Change the ECG input with the Physio button (F13) to AUX if applicable. ECG* / Aux / Resp On / Off Invert Physio Marker : On / Off F13 2D FOV Physio Select Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002977515 Jobaid: Effective Date: 12/07/2018 | HOOD/HILS Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 3. When you are ready to begin the stress echo protocol, press the Protocol: Start soft key. Preset 1 / Preset 2 Protocol : Start 2D FOV Select 4. A region of interest box (ROI) will appear once the stress echo protocol is started. Press the Next key near the Home Base to cycle between the options Pos/Size to adjust the position and size of the ROI with the trackball. Press the select button to anchor the ROI. S/N: 404169 Version: SC2000_VB21A_39 Date: Wednesday, September 26, 2018 / 15:44 2D Exercise Stress 2-Stage 09/26/2018 15:44:05 OdB / MI: 1.17 / TIS: 1.26 Rest-PLAX / Cardiac / 4V1c Acquisition Transducer Exam Preset Cardine 11 7 NTHI 20 mm TEQ: 17 Offset-3 de 2D Lead Off Persistance TEQ OFF 1 2 3 OTCE OFF PLAX Capture ROL On@ ECG in ROI Stress Echo Stage: Rest View Acquired Selected PLAX PSAX D Add Stage Protocol : Activel / Pause AAC AZC Undefin ... /2018 15:44:05 20 FOV Stress Echo Pos Size S: 0 C: 0 V: 0 5. Press the Active/Pause soft key to temporarily stop the stress echo protocol to perform other image acquisitions, such as acquiring M-Mode or Doppler data. View Add Stage Protocol : Active / Pause 2D FOV Stress Echo Pos Size Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 Orientation Note: A status grid appears in the lower right side of the screen. This identifies the current stage and view, the number of clips acquired, and the number of clips selected S/N: 404169 Version: SC2000_VB21A_39 Date: Wednesday, September 26, 2018 / 15:44 2D Exercise Stress 2-Stage 09/26/2018 15:44:05 OdB / MI: 1.17 / TIS: 1 Rest-PLAX / Cardiac / 4Vic Thumbnails Acquisition Transducer 4Vic 56 fps / 160 mm Exam Preset Cardiac II / NTHI General --- 2D- H4.3MHZ / 5 dB TEQ: 1 / Offset: -3 dB DR: 65 dB 2D Lead Off Persistence TEQ OFF 1 2 3 DICE Capture ROI On O PLAX ECG in ROI Off Stress Echo Stage: Rest View Acquired Selected View PLAX PSAX 0 O Add Stage Protocol : Active / Pause A4C O A2C O R Jndefin ... OOD 20 FOV Stress Echo 09/26/2018 15:44:05 Pos Size SOCOVO 6. Press clip store to begin acquisition of the configured number of clips Clip Store RES OVR Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 7. Images will auto-review and appear for selection. To select an image, double click the desired image. After image selection, you will return to the live imaging Acquisition task and the protocol will advance to the next view name. 8. Press the Defer Selection soft key to cancel the selection of a preferred clip. Press the Add soft key to acquire new images for a view name. Newly acquired clips are appended to previously acquired clips Note: Acquired clips that are not selected are marked for deletion at the end of the exam. If you do not complete the selection task before you end the stress echo exam, the system saves all of the acquired clips. -- Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 9. To start the next stage, rotate the Stage soft knob on the left side control panel LED display. If applicable a timer will start. Stage View DELTA Post PSAX DO Review Bi-Plane+ Dual 10. Press clip store to begin the continuous acquisition and acquire all of your Post images. Press clip store again to stop/pause acquisition. Clip Store RES DVR 211 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 5 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 11. A progress bar will appear on the right side in the status grid to show available capture space. Acquired Clips: 67 of 750 Stage: Post View Acquired Selected 12. When you are finished capturing, press the End Capture soft key to go into Review/Selection. View End Capture Add Stage Protocol : Active / Pause 2D FOV Stress Echo Pos Size 13. All Post images will be labeled as the first view name. -- Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 6 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 14. Press the Select key to click on the preferred clip. A blue border surrounds the selected clip. Right click (Next key) on this image to label it with the appropriate view name. Note: Multiple post images can be selected per view if desired. 15. Select and rename all desired post images. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 7 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 16. Use the stress echo compare task to review, sort, and compare selected stress echo clips. The sorting option applies a display layout to optimize presentation of the clips during stress review. - Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 8 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 17. Stress Echo review options include: a. Overlays – Hide or show image graphic overlays b. Format – Choose from a variety of formats to display clips (1x1, 2x2, etc.) c. Page – Use the up/down arrows to page through the acquired clips d. Sync – Synchronize the playback of selected clips e. Sort i. By View ii. By Stage iii. Compare by Stage iv. Compare to Baseline SIEMENS D Wo SC2000 2D Exercise Stress 2-Stage Acquisition Stress Echo Selection JPG JAVI Page 15 of 16 Sync Loop Aligned Playback Full R-R Playback Speed 50% 20 Exercise Preis 2-Stige ME Stress Echo : Selection / Somgarn QUE/ Stop Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 9 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 18. Press the check mark on left side of the display to close the exam. Note: Acquired clips that are not selected are marked for deletion at the end of the exam. If you do not complete the selection task before you end the stress echo exam, the system saves all of the acquired clips. Stress Echo Review 19. Helpful Hints: You can pause the stress echo protocol at any time by pressing the Active/Pause soft key. To make a measurement, point and left click on the image you wish to measure. Pause playback then press the Measure Key on the keyboard. Two timers are available and can be displayed. If enabled, the first timer starts as configured in the eSieScan protocol. The other timer can be activated manually and is located in the lower left of the display. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 10 of 11 Job Aid | ACUSON SC2000™ Ultrasound System –Stress Echo without View Control Effective Date: 12/07/2018 | HOOD05162002977515 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 11 of 11
- ACUSON SC2000™ Volume Imaging Ultrasound System – Stress Echo without View Control