PEPconnect

ACUSON SC2000 Image Optimization Step by Step

This step by step reviews 2D and M-mode controls on the ACUSON SC2000 Ultrasound System.

ACUSON SC2000™ Ultrasound System Image Optimization 2D & M-mode Controls Control Function Brightness Mode. Press to enter / exit 2D mode. 2D Rotate to increase / decrease gain (available on live or 2D frozen image). Use Next key to change sector size / position. Provides a list of currently available image presets. Press and rotate to select desired preset. Note: the Preset 1 / Preset 2 soft key may be used to Image switch between presets. Activates or deactivates a selection. Menu Rotate to cycle through the menu options and press to Menu select. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SC2000 Imorting Images SBS: Effective Date: 2/14/2020 | HOOD05162003071000 Job Aid | SC2000 Imorting Images SBS Effective Date: 2/14/2020 | HOOD05162003071000 Control Function Adjusts focal point. Rotate to move focal zone markers up / down. Note: when automatic focus is active, the Focus Focus control is disabled. Gai Freezes image, sweep, or spectral display. freeze / cine Rotate to scroll through frames. Gain Freeze / Cine R otate to increase / decrease 2D gain (live imaging only). Adjusts transmit frequency of the active multi- frequency transducer. Toggle up or down to change transmit frequency. Depth Depth Note: Decrease frequency for penetration; increase for detail resolution. MultiHz Adjusts number of gray shades displayed. Toggle up or down to increase / decrease. Multiple Frequency Note: Available on live or frozen image for 2D and Imaging Doppler. Adjusts number of gray shades displayed. Dyn R Toggle up or down to increase / decrease. Note: Available o n live or frozen image for 2D and Dynamic Range Doppler. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 2 of 6 Job Aid | SC2000 Imorting Images SBS Effective Date: 2/14/2020 | HOOD05162003071000 Control Function Adjusts transmit power for active priority mode. Tx Power Toggle up or down to increase / decrease. Note: An increase in transmit power will result in an Transmit Power increase in mechanical index. Optimizes the overall uniformity of the image brightness in the field of view (FOV). Native TEQ Three levels available: Manual (level 1), Semi-dynamic Ultrasound (level 2), Dynamic (level 3). Technology Select desired level from Image Menu. Activates or deactivates zoom function. Rotate to increase or decrease. Zoom Roll the trackball to pan the image. Zoom Note: Available on live or frozen image. Activates or deactivates RES enhanced resolution RES imaging. RESTM Enhanced Press RES and choose ROI; Press RES again Resolution Resolution and frame rate increases. Imaging Note: Available on live imaging only. L /R F9 Horizontally flips the 2D image. L /R Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 3 of 6 Job Aid | SC2000 Imorting Images SBS Effective Date: 2/14/2020 | HOOD05162003071000 Control Function U /D F10 Vertically flips the 2D image. U / D Activates or deactivates live dual display format. Dual Displays two real-time images originating from same ac- quisition side- by-side. To change the active image, press Update. Dual Note: Measurements may be performed on either side of a live dual display. Manually adjusts gain / brightness. Default all slide pods in the center. Slide pods to increase / decrease brightness. Depth Gain Com- pensation (DGC) Enters / exits M-mode or adjusts overall M-mode gain. Press to activate / deactivate. Rotate to adjust overall M-mode gain. Use trackball to position M-line. M-mode Note: Sweep speed control is located on the right LED display. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 4 of 6 Job Aid | SC2000 Imorting Images SBS Effective Date: 2/14/2020 | HOOD05162003071000 Control Function Adjusts the balance between the temporal and spatial SpaceTime resolution. Resolution Located on the LED Display. Control Rotate rotary knob to adjust between spatial and tem- poral resolution. Distinguishes the contours of an image by increasing Edge level of edge detection. Located on the LED Display. Rotate rotary knob to adjust. DELTA Differen- Increases or decreases the contrast within a 2D image. tial Echo Ampli- fication Located on the LED Display. Rotate rotary knob to adjust. Changes the number of beats / seconds captured. Capture Located on the LED Display. Beats / Seconds Note: press rotary knob to alternate between beats and seconds; rotate to change number of beats / sec- onds. Processing curves that assign echo amplitudes to gray shades. Map Located on the LED Display. Note: A gray bar represents the range of gray shades available for selected map. Colorizes the gray-scale image. Tint Located on the LED Display. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 5 of 6 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this train- ing will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and ex- amples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 6 of 6

  • ACUSON
  • SC2000
  • Image Optimization