ACUSON SC2000 Velocity Vector Imaging Quick Reference Card
This Quick Card will guide you to preform Velocity Vector Imaging (VVI) on the ACUSON SC2000 Ultrasound System.
SIEMENS 1811973 AVE THE 1.0/ 18. WI M4 25 MHZ 76 bpm 0003/24 0-40/9 121/7 34 ma PRIME Quick Reference Card eSie VVI Velocity Vector Imaging ACUSON SC2000 PRIME Ultrasound System, Release 5.0 SIEMENS Healthineers siemens.com/SC2000 Velocity Vector Imaging Image Acquisition (acoustic clip capture with extended R-R) 1. Ensure high quality ECG tracing. 2. Freeze image and select extended R-R from the image menu. 3. Frame rate of 60-90 fps is recommended. a. Narrow sector size b. Decrease Depth c. Change to T1 setting (if higher frame rate is necessary). 4. Increase gain slightly to ensure visualization of endocardial borders. 5. Freeze image and clip capture for high frame rate acquisition. Launching eSie VVI From Review or thumbnails, press Next key (right click) to access eSie VVI and Select (left click) to launch application. Workflow Guidance SIEMENS C7000 Review Only Review VVI Gamma 20 Setup Contour Analysis Summary Bullseye Results 2 | siemens.com/SC2000 Velocity Vector Imaging Parameter Selection – Soft key #2 1. Strain (Default) 2. Strain Rate 3. Velocity 4. Displacement V / D / S / SR Start / Stop WI Gamma 1. Allows user to modify image contrast and brightness. 2. Does not influence tracking results. WI Gamma 25 Setup Allows user to: 1. Exclude cycles or additional images. 2. Add / Delete R waves 3. Modify and delete valve events. 4. Flip R / L image siemens.com/SC2000 | 3 Velocity Vector Imaging Contour 1. Select View to contour. a. A4C, A2C, A3C, SAX base, SAX mid, SAX apex, Atria, RV, Free Form Trace, Delete Trace, Flip R / L 2. Select Options. b. Endo / Epi Thickness (Default: LV-10mm, LA / RV-5mm) c. Endo only tracking (if necessary) Review Only Review LVA WI Gamma 25 Setup Contour RA 2. Defining a Contour a. Draw contour along the endocardium by clicking Select (left click) for each new point of interest. I. Start and end at the ventricular annuli. II. Exclude papillary muscles or trabeculations. b. Click Next to end trace. c. Click Select to activate and move points of interest if necessary. d. Upon completion of contouring, press Next (right click) for analysis. e. Delete contour if necessary. LAALAI 4 | siemens.com/SC2000 Velocity Vector Imaging Analysis 1. Segmental VVI (default) results are displayed. 2. Access other results, if necessary. I. II. III. IV. V. VI. VII. VIII. IX. X. XI. I. Display Option VII. 16 / 17 Segment (default 16) II. Regional VIII. Short Axis View (Only available in GCS) III. Segmental IX. Select All / Deselect All IV. Volume X. Select Opposing Segments V. Zoom Graph XI. Next Heart Cycle VI. Layer Selection (Only available in GCS) Rinview Ority Review VYI Setup Comous KAROW Average Curve thes Pools Trama off GLS -25.00 % Summary LVA siemens.com/SC2000 | 5 Velocity Vector Imaging Display Options R3D L3D Endo Vectors On Epi Vectors Off Endo Trajectories Off Epi Trajectories Off Segmental Deformation Off Parametric Radial Off Parametric Long/Circ On Border On Summary Summary Volume Meat 1,43 62 global EF EDV 138.5 ml ESV 52.8 mi CO 4380.5 ml/min AVE DO I. II. III. IV. I. Export Clinical Report II. Export USB ------ Vraagin III. Next Beat AA IV. Layers 6 | siemens.com/SC2000 Velocity Vector Imaging Bullseye Results Review VVI Gamma 25 Setup Contour Analysis Summary Bullseye Results View Apical Laye Endo Duroction Strain Rate Velocity Displacer I. Overall Peak Sys Peak IV. -2 21 -14 -21 27 25 -2 II. Sys Peak Overall Peak ASC ANT SEP III. AC hr se 15 129 15 I. Strain II. Strain Rate III. Velocity IV. Displacement siemens.com/SC2000 | 7 Siemens Healthineers offers three shared service cardiovascular products: ACUSON P500, ACUSON S Family and ACUSON X700 ultrasound systems. The ACUSON SC2000 PRIME is the only dedicated premium cardiovascular ultrasound offering in Siemens Healthineers cardiology segment. ACUSON SC2000, ACUSON P500, ACUSON S Family, and ACUSON X700 are trademarks of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen 685 East Middlefield Road Germany Mountain View, CA 94043 Phone: +49 9131 84 0 USA siemens.com/healthineers Phone: +1-888-826-9702 siemens.com/ultrasound Published by Siemens Healthcare GmbH ∙ Printed in the USA ∙ 4471 0917 ∙ © Siemens Medical Solutions USA, Inc., 2017
- vvi
- velocity vector