ACUSON P500 2.0 Control Panel and Touch Screen
A step by step illustrating the ACUSON P500, Release 2.0 Control Panel and Touch Screen options.
SIEMENS Healthineers Control Panel and Touch Screen ACUSON P500™ Ultrasound System, Release 2.0 Product and System Training 11449 HC US MSC S SET Unrestricted C Siemens Medical Solutions USA, Inc. 2017 This presentation provides an overview of the system and the primary components. Objectives SIEMENS Healthineers Review the Control Panel Discuss the Alphanumeric Keyboard Identify the Touch Screen functionality Explain the Touch Pad functionality Explain the Control Panel Lighting HC US MSC S SET Page 2 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: The Objectives of this presentation are as follows: -Review the Control Panel Layout including the philosophy and identification of each control -Discuss the Alphanumeric Keyboard -Identify the Touch screen features, layout philosophy and functionality -Explain the Touch Pad layout and functionality -Explain the Control Panel Lighting User Interface SIEMENS Healthineers 2D System Serial Number : PP3018 ACUSON Register New Patient VF 13-5 D New Patient Patient Demographics Small Parts AUX ECG Tx Power 100% Edit Patient Data Last Name Patient ID ECG First Name Date of Birth DD / MM / YYYY Age TIS <0.1 M Suf Gender @ Male Female . Other Resp Height BSA mª Signal ASC 2 DTCE High Weight BP mmHg Dyn R 75 dB Exam THI 8.9 MHZ 0 dB Transducer VF13-5 accession No. 60 fps Exam Small Parts Indication Medical Information Additional Info Order Information Performing MD ferring MD Sonographer Return OK Cancel Edge DICE MultiHertz TX POWER DICE MultiHertz Touch-based User Interface Point and Click HC US MSC S SET Page 3 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 The system was designed using two approaches depending on the function and user preference. The first approach is the Touch-based user interface. This interface allows the operator to select functions in the areas highlighted in gray. The operator may: change imaging parameters, add customized text, and utilize measurement packages. The second approach is the traditional point and click method. For some functions, like entering patient information, it may be easier to use the traditional point and click method. Control Panel Design SIEMENS Healthineers Workflow Driven Approach 4 A A A Registration Acquisition Documentation .......... Review and Report 4 4 Scale Measure .................. ....................................................................................... .................... ........... HC US MSC S SET Page 4 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 The ACUSON P500 ultrasound system control panel offers a simplified user interface using a Workflow Driven Approach. This approach focuses on the 4 main areas of performing an exam: registration, acquisition, documentation and the review / report. 1. Registration: These keys are grouped to the left off the keyboard. This is a typical registration location. To perform an exam, a patient must first be registered. Next the appropriate Exam type must be selected. Select the Exam key. This is where the exams supported by the selected transducer will appear. 2. Acquisition: Once the application and transducer is selected, the system automatically loads the preset parameters. There are country specific presets available. Acquisition is achieved by the keys that are labeled in the dark purple color on the slide. The acquisition keys are utilized for selecting / changing modes, depths, optimizing the Doppler scale, etc. The Image Optimization Keys are secondary acquisition keys and are utilized less frequently (located on the top row of image optimization keys and DGC). 3. Documentation: The Print and Store selection are labeled in orange — logically grouped next to the Freeze key. 4. Review and Report: Once the exam is completed, the operator may select the Review and / or Report key to review images and the report. Control Panel SIEMENS Healthineers Power On / Off ............. Soft Keys .......... A 4 4 ....... Workflow Keys DGC ....... Depth / Zoom Major Modes TH ................... TEQ Doppler Controls Measure and Clip Store 4 User Defined ..... Print and Store Touch Pad ....... Freeze HC US MSC S SET Page 5 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 To review the specific controls on the control panel, it is easiest to begin by describing the keys from top to bottom. The Power On / Off key powers the system on or off. The top row of keys are the soft keys. The functions will change according to the mode that is being performed. For example, if measuring, the soft key options will offer measurement options. The soft keys may also be controlled by the Touch Screen. The workflow keys are located below the Power On / Off key. The workflow keys are: Registration, Exam, Review, Report. Below the Report key is the Browser, Configuration and Help key. The DCG is located to the far right. The system has TEQ technology, so the DGCs should be infrequently utilized. The major mode keys are located in the center of the control panel. The keys are grouped logically with the 2D controls (including TEQ technology and Depth) on the right and the Doppler controls (including Baseline, Scale and Invert on the left). Two User Defined keys are on the bottom left of the control panel. These can be set-up in the configuration menu. The User Defined keys can be programmed for multiple functions such as: Trapezoid, U / D Flip, L / R Flip, Full Size, Full Doppler, Full M-Mode, Arrow, Clip Store, Biopsy, TEQ Update, Steer Right or Steer Left, Text, DVR, Needle Visualization, CW, Simultaneous, Dual, Split or None. Important to note, with the 2.0 release CW and the Arrow may be stored in the User Defined keys. This is especially useful for echo exams and workflow. To customize the User Defined keys, select Config > Custom Keys > User Defined 1 or User Defined 2. In the center of the control panel is the Touch Pad. The Freeze key is located logically just to the right of the Touch Pad. The bottom right side of the panel are the documentation keys where the operator may Print, Store, Clip Store or activate the measurement screen. Objectives SIEMENS Healthineers Review the Control Panel . Discuss the Alphanumeric Keyboard Identify the Touch Screen functionality Explain the Touch Pad functionality Explain the Control Panel Lighting HC US MSC S SET Page 6 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: -Review the Control Panel Layout including the philosophy and identification of each control -Discuss the Alphanumeric Keyboard -Identify the Touch screen features, layout philosophy and functionality -Explain the Touch Pad layout and functionality -Explain the Control Panel Lighting Alphanumeric Keyboard SIEMENS Healthineers @ 12 # 3 % O & 2 V be von 4 5 a O 7 - - 6 W 00 O O B Œ W N A O E R T Y U C: O P - O A S D de F a G H 5 O B K L Z X C V 3 < A O > B ? N M ? Ctrl New Alt Clear T .... ..................................... Screen O ..... .......................... ...... New Patient Arrow Special Characters Clear Screen Text Body Markers HC US MSC S SET Page 7 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 The alphanumeric keyboard is a traditional method for typing in this environment. A few keys are highlighted that provide specific functionality for everyday exams. The New key closes the study, depending on the system configuration. It allows the operator to bypass the patient registration page and begin scanning. This is useful in the Emergency department. The Arrow key displays an arrow on the image screen to point out anatomy or areas of interest on the image. The Alt key provides access to special characters required for some languages when used in combination with the alphanumeric keys. The special characters are printed at the top of the alphanumeric keys. The Text key activates the annotation function. The Body Markers key activates the body marker function and displays the default body marker for the active exam. Objectives SIEMENS Healthineers Review the Control Panel Discuss the Alphanumeric Keyboard . Identify the Touch Screen functionality Explain the Touch Pad functionality Explain the Control Panel Lighting HC US MSC S SET Page 8 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: -Review the Control Panel Layout including the philosophy and identification of each control -Discuss the Alphanumeric Keyboard -Identify the Touch screen features, layout philosophy and functionality -Explain the Touch Pad layout and functionality -Explain the Control Panel Lighting Touch Screen SIEMENS Healthineers . Supports Touch Interaction SIEMENS Tap, Slide or Swipe functionality Customizable to User-preference Programmable Screen Saver CUSON PSO ......................................................................... SIEMENS HC US MSC S SET Page 9 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 The system has a 15.4 in Flat Panel Display (LCD, high resolution, and progressive scan (non- interlaced) with Multi-domain Vertical Alignment Technology). This technology allows the brightness of the LC molecules to appear uniform over a wide variety of viewing angles. The system supports touch interaction – one finger tap, slide and swipe. The Touch-based user interface allows the operator to select functions in the areas highlighted in gray. The operator may: change imaging parameters, add customized text, and utilize measurement packages. During real-time imaging, the screen displays clinical images, operating parameters, patient data, and control commands. The user can customize many of the screen elements to accommodate your preferences and workflow. Note: During real-time imaging, the part of the screen that displays the image does not support touch technology. During review, the entire screen supports touch technology. The screen saver feature automatically freezes the system and replaces the active display with a screen saver after the system has been inactive for a specified number of minutes. Exit the active screen saver by pressing any key, adjusting any control, or tapping the touchpad. Touch Screen Functionality SIEMENS Healthineers Action Gesture Imaging Non-imaging Priority One-finger tap Priority of selected imaging Touch Screen gestures Primary Usage E mode, Control feature, label, not available during non- text, etc. imaging applications Paging of soft-key menu One-finger drag Scroll (label menu control Touch Screen gestures Primary Usage feature, floating menu, not available during non- thumbnail panel) imaging applications Cine/Play position One-finger flick Quick scrolling of options Touch Screen gestures Primary Usage (quick-drag gesture) not available during non- imaging applications HC US MSC S SET Page 10 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: There are three primary gestures that are utilized on the Touch Screen. The Actions are: 1. One-finger tap. Examples of use—Changing a parameter, setting priority to a mode, adding text. 2. One-finger drag—Scrolling through a menu or reviewing thumbnails, activating cine/Play 3. One-finger flick (quick drag) – quick scrolling of options) Touch Screen - Left Panel Controls SIEMENS Healthineers ... 2D C 20 C SIEMENS CH5-2 Abdomen phy-to Physio Tx Power 100% Settings Settings MI 1.01 TIS 0.6 TIB 0.6 2.7 MHZ 2166 Hz Flow Med 7 dB 6 fps Fr 182 .......................................................... Cine Rate Markers Color Display Reset Cine Rate Set Start ... Next Frame Maypause57 maypause Priority Set End M ... Color Display Dual CW ....... HC US MSC S SET Page 11 | Unrestricted @ Siemens Medical Solutions USA, Inc. 2017 Speaker Notes; The selections (which are customizable) in the Left Control Panel change depending on the mode the operator is in. The selections in the Left Control Panel may be activated with the cursor or by Touch Control. Touch Screen - Soft Keys and Touch Pad SIEMENS Healthineers ... 20 C SIEMENS CH5-2 Abdomen Tx Power 100% Settings MI 1.01 TIS 0.6 TIB 0.6 2.7 MHZ 2166 Hz Flow Med 7 dB 6 fps Fr 182 Cone Rate Set Start Set End M. Next Frame Map Priority Maytrouve5 PlayPause V ............. ....... Set Start ... Previous Frame Map Set End M ... Next Frame Priority Play|Pause Play|Pause H 4 HC US MSC S SET Page 12 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: The soft key menu (which is also customizable), may be activated either with the Soft key controls on the keyboard or via touch by Touch Control. Touch Screen Layout SIEMENS Healthineers Transducer Orientation ..................... 2D Systemserial Number : PP3018 ACUSON SIEMENS 14:27:23 VF13-5 System Status Small Parts Tx Power 100% MI 0.71 TIS <0.1 TIB <0.1 Mode Indicator ............. ASC 2 DTCE High Dyn R 75 dB Biopsy THI 8.9 MHZ 0 dB ............. 60 fps Depth Markers << Steer Steer >> Imaging Parameters UR Flip UND Flip U Full Size Trapezoid Dual 4 cm Depth Display Edge Presets DICE MultiHertz FOCUS Persist High 8.9 MHZ THI Tx Power On FOCUS NU- HC US MSC S SET Page 13 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: Let’s review some of the areas of the display screen. Transducer orientation indicator: Represented by the ACUSON gold “a”, it indicates the direction of the scan Patient Banner: Displays patient information and the system date and time. System status bar: Displays information about the system, for example, wireless connectivity and battery life. Mode indicator: Displays the activated operating modes and highlights the mode that currently has priority. Tap the required mode indicator to change the active priority mode. Imaging parameters: Displays a list of imaging settings for the active imaging mode. When a specific parameter is changed, it will highlight in yellow momentarily. Depth markers: Shown in centimeter increments. Depth Display: Show current FOV selected . Touch Screen Functionality SIEMENS Healthineers 20 System Serial Number : PP3018 ACUSON 25 02/2015 14:27:23 VF 13-5 Small Parts Settings Tx Power 100% MI 0.71 TIS <0.1 TIB <0.1 ASC 2 DTCE High Dyn R 75 dB Biopsy THI 8.9 MHZ 0 dB 60 fps Steer >> UR Flip WD FLIP Trapezoid Dual 4 cm Clear Delete eSielmage ... Dyn R Presets Edge Map DICE High MultiHertz Persist Tint 8.9 MHZ Tx Power FOCUS ML ...... Left Panel Controls Left Soft Key Menu Left Soft Keys Touch Pad Right Soft Keys Right Soft Key Menu Thumbnails HC US MSC S SET Page 14 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 These next areas we will discuss are primary area used on the Touch Screen. Left Panel Controls: The selections in the Left Panel Controls vary depending on the operator’s current mode. These controls typically perform an action, such as: steering the image, using dual, accessing a measurement package. During the measurement function, the left panel displays the measurement labels. To activate a selection, tap the selection or utilize the arrow. To deactivate, tap the selection again. Thumbnail panel: The Thumbnail panel displays reference images of stored images and clips. Swipe upwards or downwards on the thumbnail panel to view the images. During Review, double tap a thumbnail to display the image in a full screen format. To add images to a report, touch the thumbnail. Left and Right Soft keys: These selections are customizable and vary depending on the mode the operator is in. Tap the desired on screen soft key or press the assigned soft key on the control panel to change the setting for the imaging parameter. Both Right and Left Soft keys function in the same manner. These are programmable in the configuration menu. Left and Right Soft key Menus: These are the additional parameters available that can be assigned to the soft keys. Pressing these will activate these functions.. Both Right and Left Menus function in the same manner. These are programmable in the configuration menu. Touch Pad: The Touch pad identifies the function assigned to the touchpad keys and gestures supported on the Touch pad. Touch Screen Functionality SIEMENS Healthineers ... 2D ACUSON SIEMENS 140 SIEMENS System Serial Number : PP3008 1291501 29101/2015 11.03:10 20 EC9-4 VF 10-5 GYN CV Tx Power 100% Select all Clearall Tx Power 100% MI 0.83 MI 0.60 TIS 0.4 TIB 0.4 TIB <0.1 ASC 1 DTCE Med Show 5.3 MHZ 4340 Hz Dyn R 85 dB Gate 2.0 mm THI 9.4 MHZ -6 dB -2 dB Teaching 15 fps 29 fps 24 Markers Cine Rate Report Study UR Flip UND Flip F1262 Print Cheat Delete Bear Delete Set Start .. Set End M. Previous Next Frame DICE Dyn R Layout Full Screen Page Print Export Delete Med Play/Pause PlayPause 85 da 1x1 20/33 Frozen Image Review Mode HC US MSC S SET Page 15 | Unrestricted @ Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: The Soft-Key (Optimization) controls change depending on what action is done. When in a frozen image, the screen displays the function available in that mode. Example, Cine functionality and post-processing features. When in Review, some of the Left Controls or Action keys are dithered out and not available. This provides the user—only the keys they can access, making it easier to use. Touch Screen Functionality SIEMENS Healthineers ... 20 C PW System Serial Number : PP3008 ACUSON SIEMENS 10:30-27 20 C PW System Serial Number : PP3008 ACUSON SIEMENS , 1:15.03 VF 10-5 CH5-2 CV Abdomen Abdomen Tx Power 100% Tx Power 100% CCA Prox MI 0.58 MI 0.60 TIS <0.1 TIS 0.8 TIB <0.1 TIB 2.7 CCA Mid 5.3 MHZ 2.7 MHZ 4340 Hz 3551 Hz Gate 2.0 mm Gate 4.0 mm CCA Dist 25.0 -14 dB 6 dB 13 fps 8 fps ICA Prox Invert 3.5 cm 16 mm ICA Mid ICA Dist ECA - 63.7cm/s PG1 = 1.2mmHg V2 = 16.0cm/s Freq2 0.55KHz TR V2 - 24.7cm/s PG2 =0.2mmHg Freq2 = 0.85KHz PG2 = 0.1mmHg Clear puters Flow Volu ... Time PI Auto Pi Manual Velocity Edit PS & ED Delete All Delete MOA POSIt .. Flow Volu._ Time Pl Auto PI Manual Velocity OS & ED Delete All Delete MDA Posit VIN2- VI/V2 ... undo Acceleration Delete Acceleration Delete Measurement Package Standard Measurement HC US MSC S SET Page 16 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: When in a Measurement package, the Left Panel Control Keys show the measurements associated with the package. When a direct measurement such as a PI, RI or Velocity, then the menu only displays the choices available. This is an important point to emphasize. The keys are designed around the workflow needed for that specific task. Objectives SIEMENS Healthineers Review the Control Panel Discuss the Alphanumeric Keyboard Identify the Touch Screen functionality . Explain the Touch Pad functionality Explain the Control Panel Lighting HC US MSC S SET Page 17 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: -Review the Control Panel Layout including the philosophy and identification of each control -Discuss the Alphanumeric Keyboard -Identify the Touch screen features, layout philosophy and functionality -Explain the Touch Pad layout and functionality -Explain the Control Panel Lighting Touch Pad Layout SIEMENS Healthineers The Touch pad and keys provide access to both imaging and non- UPDATE imaging functionality Navigating patient registration form and configuration screens During imaging, the Touch pad performs positioning and TOUCH PAD SET SET placement functions Position a region of interest or anchor measurement calipers HC US MSC S SET Page 18 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 The Touch pad and Touch pad keys provide access to both imaging and non-imaging functionality. For example the Touch pad is utilized for navigating the patient registration form and the configuration screens. During imaging, the Touch pad performs positioning and placement functions. For example, position a region of interest or anchor measurement calipers. During non-imaging functions, the Touch pad works like a mouse on a personal computer. Example of touchpad legend: Update key: This key performs an assigned function depending on the current task, for example, the update function during Doppler imaging. Touch Pad: The Touch pad supports gestures. Set Keys: Both Left and Right Set keys perform the same function for the current task, for example, to play a clip or position the field of view. Touch Pad Functionality SIEMENS Healthineers Action Gesture Imaging Non-imaging Priority Multi-touch Gestures Gate size N/A Secondary Usage Two-finger scale 2D size (pinch-spread) Color ROI One-finger Gestures Cursor position Cursor position Primary Usage One-finger drag Measurement marker Cine/Play position Mark position One-Finger Gestures Activates the function N/A Secondary Usage One-finger tap assigned to touchpad keys Activates the selected button on a form Positions a caliper HC US MSC S SET Page 19 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: There are three primary gestures that you can use on the Touch Pad.. This works similar to a tablet device. Gesture and Function Pinch and spread with two fingers Sizes an on-screen object, for example, the region of interest and - the Doppler gate. Tap the touchpad -Activates the function assigned to the left and right touchpad keys. -Activates the selected button on a form. -Positions a caliper during the measurement function. One Finger drag: Slide one finger horizontally or vertically across the touchpad -Positions an on-screen object, for example, the M-mode cursor or a measurement marker. -Scrolls a list, for example, in the patient report. Objectives SIEMENS Healthineers Review the Control Panel Discuss the Alphanumeric Keyboard Identify the Touch Screen functionality Explain the Touch Pad functionality Explain the Control Panel Lighting HC US MSC S SET Page 20 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: -Review the Control Panel Layout including the philosophy and identification of each control -Discuss the Alphanumeric Keyboard -Identify the Touch screen features, layout philosophy and functionality -Explain the Touch Pad layout and functionality -Explain the Control Panel Lighting Control Panel Lighting SIEMENS Healthineers Illuminated Keys Power Text Body Marker Freeze Increased brightness when key is used HC US MSC S SET Page 21 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: When the ultrasound system is in use, controls and keys on the control panel are supported by backlighting. The brightness of the backlighting increases when a control is active. The alphanumeric keyboard on the control panel is also illuminated. A few of the primary keys will remain in blue as they are commonly used keys. Summary SIEMENS Healthineers Review the Control Panel Discuss the Alphanumeric Keyboard Identify the Touch Screen functionality Explain the Touch Pad functionality Explain the Control Panel Lighting HC US MSC S SET Page 22 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Speaker Notes: In summary, Upon review of the Control panel, Touch Screen and Touch Pad, the system was designed as Workflow driven-based on an exam is typically performed.. The keys are limited and designed to make the system easy to use. It is adaptable and allows the dual interface for both the traditional user and users who prefer the touch operation. . Questions HC US MSC S SET Page 23 | Unrestricted C Siemens Medical Solutions USA, Inc. 2017 Questions?
- acuson
- p500
- control panel
- touch screen
- vascular
- cardiology
- general imaging