ACUSON S Family Ultrasound System - Exporting an eSieScan™ Protocol
ACUSON S Family Ultrasound System - Exporting an eSieScan™ Protocol
ACUSON S Family™ Ultrasound System‐ Exporting an eSieScan™ Protocol 1. Press System Config (F4) to open the system configuration menu. System Config F4 2. Choose eSieScan Protocols. System Settings Seid ramber: 205:51 System dalacome. Monday, February IS. 2014 / 10:56 Basic System Basic System 2 Protocols Image Text Editor Breast # Cardiac Add Name Patient Registration OB Protocol Breast Patient Banner @ Vascular Add View Progression DICOM Configuration TEST OB o Automatic D RUQ CAROTID Copy Manual e Sie Scan™ Protocols DIMAQ Protocols E ABDOMINAL Remove Automatically end when all views completed Doppler / M-Mode Setup At End Protocol Footswitch Move o Remain in acquisi Enter Review Print/Store Enter Report Body Markers & Text Down Export Order Physio System B RT 12:00 Rad Meas. Labels Display Bottom B RT 12:00 ARad B RT 1:00 Rad System-wide Meas. Tools B RT 1:00 ARad 2D Meas. Tools B RT 2:00 Rad B RT 2:00 ARad Move Doppler Meas. Tools B RT 3:00 Rad B RT 3:00 ARad Top Custom Meas. Labels B RT 4:00 Rad Custom Growth Curves B RT 4:00 ARad Up B RT 5:00 Rad Meas. Report Settings B RT 5:00 ARad Down OB Calculations B RT 6:00 Rad Bottom Import B RT 6:00 ARad Custom Gest. Age Tables B RT 7:00 Rad OB Report Export B RT 7:00 ARad App Specific Settings ABVS Settings Service Save Cancel Restore Factory Settings 3. Insert USB Device into the system Select Export. Protocols Breast Cardiac Add Protocol Name OB Breast @ Vascular Add View Progression TEST OB o Automatic D ABDOMINAL Copy ~ Manual Remove Automatically end when all views completed At End Protocol Move . Remain in acquisition Top Enter Review c Enter Report Up Export Order Down B RT 12:00 Rad Bottom B RT 12:00 ARad B RT 1:00 Rad B RT 1:00 ARad B RT 2:00 Rad B RT 2:00 ARad B RT 3:00 Rad Move B RT 3:00 ARad Top B RT 4:00 Rad B RT 4:00 ARad Up B RT 5:00 Rad B RT 5:00 ARad Down B RT 6:00 Rad Bottom Import B RT 6:00 ARad B RT 7:00 Rad Export RT 7:00 ARad Save Cancel Restore Factory Settings SIEMENS www.usa.siemens.com/healthcare Page 1 of 3 4. The Import/Export Box will appear with a list of all Protocols both on the system and on the USB Device. Protocols Breast # Cardiac Add Name OB Protocol Breast Vascular TEST OB Add View Progression o Automatic D RUQ + CAROTID Copy ~ Manual E ABDOMINAL Remove Automatically end when all views completed Import Protocols From E:\ 0] Protocol Action if Checked M ABDOMINAL Delete Existing Protocol Breast Reset to Factory Protocol M Cardiac Reset to Factory Protocol M CAROTID Delete Existing Protocol MOB Reset to Factory Protocol M RUQ Delete Existing Protocol M TEST OB Delete Existing Protocol Vascular Reset to Factory Protocol Move Select Top All None Import Cancel Up 24 :00 ARad 3 RT 5:00 Rad B RT 5:00 ARad Down B RT 6:00 Rad Bottom Import BRT 7:00 Rad Export B RT 7:00 ARad Save Cancel Restore Factory Settings 5. Choose Select All, Select None, or Manually check or uncheck Boxes. Protocols Breast # Cardiac OB Protocol Name Breast Vascular Progression TEST OB Add View o Automatic E ABDOMINAL Copy ~ Manual Remove Automatically end when all views completed Export Protocols To E:\ 0 Protocol Action if Checked ABDOMINAL Export Breast Export M Cardiac Export MOB TEST OB Export Export Vascular Export 3 3 3 3 Move All lect Cance Top None Export B RT 4:00 ARad Up B RT 5:00 Rad B RT 5:00 ARad Down B RT 6:00 Rad Bottom Import B RT 6:00 ARad B RT 7:00 Rad Export B RT 7:00 ARad Save Cancel Restore Factory Settings 6. Once the desired Protocols to Export are checked, select Export. Protocols Breast Cardiac Name OB Protoco Breast Vascular + TEST OB Add View Progression o Automatic E ABDOMINAL Copy ~ Manual Remove Automatically end when all views completed Export Protocols To E:\ [] Protocol Action if Checked M ABDOMINAL Export [ Breast Export M Cardiac Export MOB Export [ TEST OB Export D Vascular Export Move All Select Export Cancel Top None B RT 4:00 ARad Up B RT 5:00 Rad B RT 5:00 ARad Down B RT 6:00 Rad Bottom Import B RT 6:00 ARad B RT 7:00 Rad Export RT 7:00 ARad Save Cancel Restore Factory Settings SIEMENS www.usa.siemens.com/healthcare Page 2 of 3 7. Once Exported and complete, the Import/Export Box will disappear. Protocols Breast Cardiac Add Name Protocol OB Breast # Vascular TEST OB Add View Progression o Automatic # ABDOMINAL Copy ~ Manual Remove Automatically end when all views completed At End Protocol Move . Remain in acquisition Top Enter Review Enter Report Up Down Export Order B RT 12:00 Rad Bottom B RT 12:00 ARad B RT 1:00 Rad B RT 1:00 ARad B RT 2:00 Rad RT 3:00 Rad Move BET 3:00 Top B RT 4:00 ARad Up B RT 5:00 Rad Down B RT 5:00 ARad B RT 6:00 Rad Bottom Import BRT 6:00 ARad 3 RT 7:00 Rad RT 7:00 ARad Export Save Cancel Restore Factory Settings SIEMENS www.usa.siemens.com/healthcare Page 3 of 3
- s2000
- s3000