ACUSON S Family Ultrasound System Scanning with eSieScan Protocols
ACUSON S Family Ultrasound System Scanning with eSieScan Protocols
ACUSON S Family™ Ultrasound System Scanning with eSie Scan™ Protocols 1. Begin a new patient via the new patient key. Esc Rapport Patient Browser 2. Click on the drop-down menu next to Protocols. ast Name First Name Indication Patient IL Requested Procedure Accession No Date of Birth midd yyyy Sex @ Male @ Female 5 Other EXAM INSTITUTION Transducer 6C1 HD Institution Name SIEMENS Study Renal Referring Physician Operalor Protocol Adational Info OK Cancel Preregister Search 3. Select the eSieScan protocol you would like to use. The system activates the first view of the protocol when you begin the patient examination. FA INSTITUTION Cancel SIEMENS www.usa.siemens.com/healthcare 560 Effective Date: 09/06/2016 Page 1 of 5 4. If not selected from the demographics page, select a protocol from the image menu during imaging. The system displays the name of the selected protocol on the image menu. Note: The protocol remains mage TEO Set active during imaging if you Timmer Off change the transducer or exam type. Live Dua Dua Protoco ABDOM RIGHT LEG NOUS LESTLEG BLEFT ARM LTLEG 5. Select the view in the thumbnail panel, if necessary the system displays a blue border around the active view. Press the key assigned to the store function to save the image. If measurements have been defined for the view, the system displays the measurements menu and activates the first measurement marker. Note: You can capture multiple images or clips of volumes for a single view. The system inserts additional views after the active view. SIEMENS ECT HD /'Abdo THEE/ H5 50 MHZ -1 dB /OR 70 ASCOT DICE M CBD LONG - 6. To add a view: Select Add View from the image menu The system displays the Add View dialog box with the active view selected Add GB TRV Protocol GB SAG GB SAG CBD ABDOMEN JW CBD Pause Protocol PANC End Protocol Show All Views PANC Add View PANC Rename View Delete Image LIVER HV CBD SIEMENS www.usa.siemens.com/healthcare Page 2 of 5 7. Enter the name of the New View. The system inserts the new view before the current view. Change the imaging mode, measurements, and body marker, if necessary. To change the location of the new view, select the new location in the acquisition or review list and then click Save. To exit without saving the new view, click Cancel. Add GB TRV GB SAG GB SAG CBD CBD PANC PANC PANC LIVER HV CBD 8. To delete a view: Select the view in the thumbnail panel Select Delete Image from the image menu. The system removes the image and measurements from the protocol view. The measurements will not be deleted from the report Note: The deleted view is still available in Review. Protocol 3 sec ABDOMINAL Pause Protocol End Protocol Show All Views Add View Rename View Delete Image A 9. To rename a view: Select the view in the thumbnail panel Select Rename View from the image menu Enter a view name and then click Save Protocol 3 sec ABDOMINAL Pause Protocol End Protocol Show All Views Add View Rename Rename View Delete Image Save Cancel SIEMENS www.usa.siemens.com/healthcare Page 3 of 5 10. To select the next or previous view for acquisition: Click Previous in the thumbnail panel to select the previous view that has not been acquired. Or, select Previous from the image menu Click Next in the thumbnail panel to select the next view that has not been acquired. Or, select Next from the image menu THI ClarifyVE GR SAG CR-SAGE CRn PANC Select 2D FOV 4 of 33 11. To display all views: Select Show All Views from the image menu. The system displays up to 30 views on a page To exit “Show All”, select a view. Or, click Close SIEMENS Protocol PANC PAN IVER HIV 3 Bec ABDOMEN JW Pause Protocol LIVER RPV LIVER RPV LIVER LPV LIVER LPV LONG LIVER LONG LIVER End Protocol Show All Views Add View ONG LIMVER RT LONG UNTR RT LONG UNTER RT MC PROX AO Rename View Delete Image DES AORIA TRV DS NO SING RY KID SAG RT KID TRV RT KID SAG LT KID Close m Reorder 12. To change the view order: Select Show All Views from the image menu Select Re-Order Select a view Click the location to insert the selected view To save changes and exit the re-order function, click Close To exit the re-order function without saving changes, clear the Re-Order checkbox Protocol SIEMENS PANK PANG PANC LIVER HY ABDOMEN JW Pause Protocol End Protocol LIVER LFV LIVER LPV LONG LIVER LONG LIVER Show All Views Add View LONG LIVER NT LONG LIVEK KI LONG LIVEK KI PRIX AD MID NO Rename View Dolote image DES ADRIA SAG HT K THY RE KID Close I Reorder SIEMENS www.usa.siemens.com/healthcare Page 4 of 5 13. To pause a protocol: Select Pause Protocol from the image menu. Or, select another protocol Note: You can save images, clips, volumes, and measurements when the protocol is not active. The information will not be saved as a protocol view, but as an image outside the paused protocol. The Paused Protocol Images will be displayed at the end of the exam. Select Resume Protocol from the image menu Protocol Protocol 3 sec 3 sec ABDOMINAL ¡le Scan Protocols Pause Protocol Resume Protocol End Protocol End Protocol Show All Views Show All Views Add View Add View Rename View Rename View Delete Image Delete Image 14. To end the protocol: Select End Protocol from the image menu The system saves the data and activates review, reports, or acquisition depending on the settings in system configuration Note: If there are incomplete protocol views, the system displays a message to complete or skip the views. Protocol ABDOMEN JW Pause Protocol End Protocol Show All Views Add View Rename View Delate imago SIEMENS www.usa.siemens.com/healthcare Page 5 of 5
- s2000
- s3000