Adjust to Patient (InSpace)
Job aid describing steps to realign patient to 3D image for accurate 3D Roadmap.
Adjust to Patient (InSpace) Job Aid Advanced Therapies - Application Software VB21. **There is an additional job aid available on PEPconnect to determine SW version of the system. Adjust to Patient is used to align/realign a 3D volume to the current ARTIS image, e.g. after patient movement. This function can be used when performing iPilot or iGuide. 1. If the user determines that the patient has moved, Adjust to Patient can be activated from the InSpace touch screen menu or from the control room X-ray tab found in the InSpace taskcard. Settings Exam Image Quant InSpace Filming Manipulate Type | Orient | Table 2D R R 3D View + 3D Overlay REFO InSpace Live Brightness 100 3D Tools Opacity 80 Clip | Tools | Measure | X-Ray Live W Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOOD05162003101310 Healthineers Job Aid | Adjust to Patient (InSpace) Effective Date: 07/06/2020 | HOOD05162003101310 2. The Adjust to Patient window opens. InSpace shows an overlaid image consisting of both the 2D fluoro image (orange) and the 2D projection of the 3D volume (blue). Each is displayed in a different color so that the registration results can be better distinguished apart. Adjust to Patient X 2D Projection of 2D Fluoro Image Recommendation: the 3D image No collimation Advanced Alignment auto Manual Alignment AVY ALVY 100% Overlay of 2D VRT fluoro and 3D 2D Overlay 0% OK Cancel 3. User can choose Auto Alignment or Manual Alignment or use a combination of both. If the two sets of images are only slightly misaligned, Automatic Alignment is sufficient. 4. Click on the auto icon and the system will align data automatically. If the result is satis- factory, click OK. auto Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOOD05162003101310 Healthineers Page 2 of 4 Job Aid | Adjust to Patient (InSpace) Effective Date: 07/06/2020 | HOOD05162003101310 5. If the result is not satisfactory, the user can perform manual alignment. Using the manu- al alignment directional arrows, the user can move the 3D image to match the 2D fluoro image. (1) (4) (3) (2) (2) (1) Linear movements (2) Rotational movements (3) Inner arrow for small movements (4) Outer arrow for large movements 6. User can adjust the display percentage of 3D overlay that is visualized to aid in alignment. 100% 0% 7. User adjusts the position of the 3D until the two datasets are in the identical position. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOOD05162003101310 Healthineers Page 3 of 4 Job Aid | Adjust to Patient (InSpace) Effective Date: 07/06/2020 | HOOD05162003101310 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commerci ally available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOOD05162003101310 Healthineers Page 4 of 4
- Adjust to Patient (InSpace)