ADVIA® 2120i Hematology System Quality Control Online Training
Prepare and run QC samples, review QC results, print reports, and define new QC files. This clinical laboratory training qualifies for continuing education units (CEU).
På CLINITEK Status+ instrumentet kan de aktuelle indstillinger ændres, så de opfylder arbejdsstedets specifikke behov. I dette afsnit vil du lære, hvordan du ændrer indstillinger i softwaren og øve dig i at udføre disse ændringer. Klik på Start for at begynde den interaktive simulering. Welcome to ADVIA® 2120i Hematology System Quality Control Overview. This lesson outlines the procedure for processing quality control samples, managing quality control results and setting up quality control files. Select Next to continue. Identify the steps to set up a new QC file Locate and review QC results Print QC results Sequence the steps to process QC samples Upon successful completion of this course, you will be able to: Select Next to continue. Når CLINITEK Status+ instrumentet tændes for første gang, udfører instrumentet en automatisk diagnostisk test. Opstartsguiden hjælper dig hurtigt med at indstille de grundlæggende funktioner, der er nødvendige for at betjene instrumentet. Disse indstillinger kan ændres så de passer til arbejdspladsens behov og præferencer. Læs mere om instrumentindstillinger i modulet Clinitek Status - Instrumentindstilling Congratulations. You have completed the ADVIA 2120i Hematology System Qualty Control Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Sequence steps to process QC samples Control materials should be assayed as follows: At the beginning of each shift or at some other interval chosen by the laboratory After a reagent lot number change, After replacement of any part or component of the analytical module that may affect analytical performance Run well mixed controls at room temperature on the autosampler, in the manual closed mode or manual open mode When aspirating in the MCTS or MOTS wait for the green light to stop flashing before removing the control When running on the autosampler make sure the barcode is facing forward Barcoded tubes direct results to the appropriate QC file After running controls return the commercial control samples to the refrigerator Locate and view QC results The Data Manager stores the control results for review, validation and printing. Sample Control lists the control samples that were run and gives a quick visual of the status of QC results using the green, yellow and red color coding Validate results in Review/Edit Print results in the QC tab Color coding is used to quickly determine the status of quality results in the Sample Control Panel, Review/Edit and the QC tab. Follow laboratory guidelines for reviewing and accepting QC results Quality control results display in four formats including a table format, SDI graph, Scatter graph and LJ graph Print QC reports Print Selection allows for multiple print options QC reports are available in table or graph formats Print reports by date is an option on the print selection screen Identify steps to set up a new QC file Import QC information using a disk or scannable bar code sheet Use the Control Dictionary for commercial and whole blood patient control setup Select Next to continue. There are two types of control material that can be used to monitor hematology instrumentation precision and accuracy: SS StaStabilized cell suspension in commercial quality control products Patient samples that are retained to periodically monitor performance trends Control materials should be assayed as follows: At the beginning of each shift or at some other interval chosen by the laboratory After a reagent lot number change After replacement of any part or component of the analytical module that may affect analytical performance Autosampler Learn about running control samples on the autosampler. Checklist TitleChecklist TypeChecklist ContentPrepare controlsHTML Select the play arrow to begin the video. Allow controls to reach room temperature. Manually mix the tubes by inversion until the RBC's are completely suspended. Select each checkbox to learn more about running controls on the autosampler. Load the controlsHTML Select the play arrow to begin the video. Load controls: Insert tube into rack with the barcode label visible above the rack barcode label that indicates the rack number and sample position. Do not twist tube within the rack. Load rack onto the input queue with the labels facing toward the front of the analyzer. The lot number will be read from the barcode label and the results will be automatically placed in the appropriate QC file. Prepare the instrumentHTML If the standby indicator is lit, select Standby. Start the runHTML At the touchpad, select Start/Stop Sampler indicator. The Start and Rack in Sampler indicators are lit. Return controls to the refrigeratorHTML After running the controls return them to the refrigerator. When complete, select the X in the upper-right corner to close the window and continue. Manual Closed Tube Sampler Learn about running control samples in the MCTS. Checklist TitleChecklist TypeChecklist ContentPrepare controlsHTML Select the play arrow to begin the video. Allow controls to reach room temperature. Manually mix the tubes by inversion until the RBC's are completely suspended. Select each checkbox to learn more about running control samples in the MCTS. Prepare instrumentHTML If the Standby indicator is lit, select Standby. Scan the tubeHTML Scan the tube label or enter the sample information in the Manual Sample ID tab. This insures the QC results go to the corresponding QC file. IMPORTANT: Make sure the correct sample ID appears on the status line before aspirating a sample. Waiting displays on the status line while the system searches for a matching workorder. Aspirate the sampleHTML Select the play arrow to begin the video. Aspirate the sample. Insert and push down the tube containing the well-mixed sample into the manual closed-tube sampler. Hold the tube parallel to the sampler well wall. Sample is automatically aspirated-the sampling light flashes. When the sampling light stops flashing, remove the tube. Return controls to the refrigeratorHTML After running the controls return them to the refrigerator. When complete, select the X in the upper-right corner to close the window and continue. Manual Open Tube Sampler Learn about running control samples on the MOTS. Checklist TitleChecklist TypeChecklist ContentPrepare controlsHTML Select the play arrow to begin the video. Allow controls to reach room temperature. Manually mix the tubes by inversion until the RBC's are completely suspended. Select each checkbox to learn more about running control samples on the MOTS. Prepare InstrumentHTML If the Standby indicator is lit, select Standby. Scan the tubeHTML Scan the tube label or enter the sample information in the Manual Sample ID tab. This insures the QC results go to the corresponding QC file. IMPORTANT: Make sure the correct sample ID appears on the status line before aspirating a sample using either the manual open-tube sampler or the manual closed-tube sampler. Waiting displays on the status line while the system searches for a matching workorder. Aspirate the sampleHTML Select the play arrow to begin the video. Aspirate the sample. Position tube so that the sampler probe is immersed into the well-mixed sample. You should immerse the sampler probe only deep enough (approximately 0.25-in.) to ensure aspiration. Press the aspirate plate. Sampling light flashes during aspiration When the sampling light stops flashing, remove the tube. Return controls to the refrigeratorHTML After running the controls return them to the refrigerator. When complete, select the X in the upper-right corner to close the window and continue. 시약 재고를 모니터링 하기 위해서는 시약 카트리지 인벤토리 화면을 확인하고, 재고가 충분한지 확인하는 소모품 경고에 응답합니다. 시약 인벤토리 화면에 액세스하려면 운영 메뉴에서 F4: System Prep 을 누른 후 F1: Inventory를 선택합니다. 혹은 Alt/I 단축 키를 누를 수도 있습니다. After controls have been processed locate and review the results in the Data Manager. The Data Manager stores the control results for review, validation and printing. Color coding is used to quickly determine the status of quality control results. Quality control results display in four formats including a table format and a LJ graph. Locate and Review QC Results Learn how to locate and review QC results. Checklist TitleChecklist TypeChecklist ContentSample Control PanelSimulationInstructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003651/sim_ADVIA2120i_QCSCP_800X600_9/sim_ADVIA2120i_QCSCP_800X600_9.swfHTML5 File:/content/generator/Course_90003651/sim_ADVIA2120i_QCSCP_800X600_9/index.htmlPDF File:Review/EditSimulationInstructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003651/sim_ADVAI2120i_QCreved_800x600_9/sim_ADVAI2120i_QCreved_800x600_9.swfHTML5 File:/content/generator/Course_90003651/sim_ADVAI2120i_QCreved_800x600_9/index.htmlPDF File:QCSimulationInstructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003651/sim_ADVIA2120i_QCtab_800x600_9/sim_ADVIA2120i_QCtab_800x600_9.swfHTML5 File:/content/generator/Course_90003651/sim_ADVIA2120i_QCtab_800x600_9/index.htmlPDF File: 특정 카트리지 로트를 선택해서 수화할 테스트의 수를 입력할 수 있습니다. 운영 메뉴에서 F4: System Prep, F2: Reagent Prep을 각각 선택해 hydration by lot 화면을 봅니다. 현재 선택된 항목과 로트, 수화된 테스트와 수화되지 않은 테스트, 그리고 수화될 테스트의 개수가 나타납니다. 수화할 테스트의 개수를 입력하고 F4: Hydrate 을 선택해 수화를 시작합니다. View or define controls in the Control Dictionary window. A file must exist for each lot number of control. When running the control on the analyzer the barcode of the control is scanned and then the results for that control are entered into the associated file. Commercial controls such as 3-in-1 TESTpoint® or whole blood patient controls, usually a normal patient sample, are defined in the Control Dictionary under Tools Modify. Sufficient data, based on the laboratory's guideline, must be collected for the whole blood control before completing the file setup. Set up commercial control files Learn how to set up commercial control files. Checklist TitleChecklist TypeChecklist ContentNavigate to Control DictionaryHTML Navigate to Control Dictionary by selecting Customize > System Setup > Tools Modify > Control Dictionary. For the ADVIA 2120i with Autoslide select Customize > Analyzer Setup > Tools Modify > Control Dictionary. Select each checkbox to learn more about setting up QC files. Insert disk or scan barcoded sheetHTML Remove the disk or scannable barcode sheet from the 3-in-1 TESTpoint® control package. Insert the disk into the system computer or scan the control assay sheet with the hand-held barcode reader. Select ImportHTML Select Import on the Control Dictionary window. Select controlHTML Select a control to import from the list and then select OK to open the record. If there are no controls to import, a "no data available" message appears. Select Cancel to close the message. Enter code nameHTML The Import Dialog box opens displaying the control record selected. Type the control code (up to six characters) you want to assign to the new control. When you select a control with a name that corresponds to an existing control, the system automatically uses the lot number to define the SID# for the control. After entering the code select OK to close the Import Data window. Select Test PanelHTML Select the Test Panel box to include background colors in the Test Table Grid of the Sample Control Panel tab. The green, yellow and red colors indicate the status of the QC results and are a quick visual aid indicating the quality of the QC results. Select OK to finishHTML Select OK to complete file setup. When complete, select the X in the upper-right corner to close the window and continue. Set up Whole Blood Control file Learn how to set up a Whole Blood Control file. Checklist TitleChecklist TypeChecklist ContentOpen WBCONT in Control DictionaryHTML The Whole Blood Control file is used each day to monitor the system using a fresh patient sample. After running the control the number of replicates required by the laboratory to collect adequate data, navigate to the Control Dictionary in Tools Modify and open the WBCONT file. Here the statistcal date collected by the system is imported into the Whole Blood Control file. The whole blood control is then run throughout the day and will be evaluated like a commercial control in Review/Edit. Select each checkbox to learn how to set up a Whole Blood Control file. Tab down to TestsHTML In the Control Dictionary, tab down to the Tests Area. You must tab down to the TESTS area first before Assay and S.D. ranges can be imported. Import Assay and SD valuesHTML Select “Assay and SD” on the top of the screen. The assay values and SD ranges are imported into the TESTS area of the Control Dictionary. The results for this day's Whole Blood Control replace the previous day's results. Select OK to save the changes. When complete, select the X in the upper-right corner to close the window and continue. There are multiple options for printing QC reports. The most commonly used report is the Daily All Tests as it provides a spreadsheet view of the control results with statistics. Print Selection Learm more about Print Selection. Base ImageHotspotsText BlocksImage File Export Daily only QC or export Daily plus Cumulative QC to a file used for ILQC. Select all data or enter a range of dates to print. Select Accuracy or Reproducibility here. Choose to print only Daily or only Cumulative control results or select All Daily to include all QC data from both cumulative and daily control files. Select reports here based on daily or cumulative QC data. Select the Daily All Tests to print a table or graph format. Printing QC Reports Learn more about printing QC reports. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003651/sim_ADVIA2120i_PrintQC_800x600_9/sim_ADVIA2120i_PrintQC_800x600_9.swfHTML5 File:/content/generator/Course_90003651/sim_ADVIA2120i_PrintQC_800x600_9/index.htmlPDF File:
- 120
- 2120
- precision
- accuracy
- SS StaStabilized
- MCTS
- MOTS
- Manual Closed Tube Sampler
- Manual Open Tube Sampler
- autosampler
- Levey Jennings
- PE