ADVIA® 360 Hematology System Competency Checklist
Education resource material designed to document competency mastery on-the-job. This Competency Checklist represents all learning objectives for this training area.
ADVIA® 360 Hematology System Competency Checklist Once an employee has acquired the necessary knowledge and skills to perform basic operation tasks this checklist can be used to observe the employee perform the required tasks for their core job responsibilities and to document demonstrated competency. The observer places their initials and date beside the task when it is performed successfully. Successful completion for each task is determined by the facility. The standards used to evaluate can be documented in the “Criteria” section below. Use the area on the last page to record comments or areas of improvement. If necessary, the observer can record recommended next steps of action for areas of improvement or development opportunities. When all required tasks are completed, the supervisor and employee sign and date this document as a record of completion. Criteria - Standards for successful completion of each task (e.g. Accuracy, Time, Quality, etc.): Observer’s Initials and Completion Date Topic/Tasks System Overview Identify the front and top panel components Identify the back panel connectors and reagent components Locate the right side external and internal components and describe their function Locate the left side external components and describe their function Describe the components of the Home screen Quality Control Import QC Process and review QC Sample Processing Process patient samples Retrieve patient results Daily Startup Empty waste and reset waste level Perform daily shutdown and startup Check air bubbles Check and replace reagents Perform Blank Measurements Troubleshoot Blank Measurement Flags Technologies Describe how the system uses photometric light absorbance to measure the hemoglobin concentration Explain how the system uses volumetric impedance to determine the number and volume distributions of cells Describe how the system determines the 3-part white blood cell differential analysis Explain the measurement sequence of the system’s analysis process HILS1901 Effective Date: 09/18/2018 Page 1 of 2 SIEMENS siemens.com/healthineers Healthineers ADVIA® 360 Hematology System Competency Checklist Comments Areas of Improvement Next Steps n Primary Operator n Secondary Operator has been trained on the above documented tasks Supervisor: Employee: Date: HILS1901 Effective Date: 09/18/2018 Page 2 of 2 SIEMENS siemens.com/healthineers Healthineers
- advia
- hemotology heme
- competency
- training
- mentor
- checklist
- consolidated