ADVIA® 560/560AL Hematology System Overview Online Training
Identify key hardware and software components and describe their function. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the ADVIA® 560/560AL Hematology System: System Overview Online Training course. The ADVIA 560/560AL Hematology System is a fully-automated hematology system for the in vitro diagnostic testing in clinical laboratories. The system provides leukocyte (WBC), erythrocyte (RBC), platelet (PLT), and hemoglobin (HGB) concentrations, along with a 5-part WBC differential measurement (LYM%, MON%, NEU%, EOS%, BAS%). In this course you will learn about the internal and external components necessary for daily operation. Select Next to continue. Upon successful completion of this course, you will be able to: Identify the front panel components and describe the function of the front internal components Identify the back panel connectors and reagent connectors Describe the function of the left side internal components Explain the function of the right side external and internal components Describe the components of the Graphical User Interface Select Next to continue. Congratulations. You have completed the ADVIA 560/560AL Hematology System System Overview online training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Download and print a copy of the Course Review. Identify the front panel components and describe the function of the front internal components Front Panel Components: Touchscreen Has a pressure sensitive overlay Allows selection of menu items and pressing of buttons by gently pressing or tapping the surface of the selected item Status Light Green - Ready Red - Busy Orange - Standby Sample Rotor Station Contains the same rotor which holds the sample tube (open or closed) in an adaptor Rotates the sample inside for aspiration Front Internal Components: Dilutors - Control the volume and flow rate of reagents through the pneumatic components Shear Valve - An integrated multi-functional valve for segmenting precise volumes of blood Optical Head Unit - Contains the laser source, optical detectors, and the flowcell for optical measurement Sample Rotor - Holds open or closed sample tubes for manual processing Identify the back panel connectors and reagent connectors Back Panel Components: Power Connector - Connects to grounded power outlet Power On/Off Switch - Turns all of the electrical power to the system both On and Off I/O Ports Panel - Provides standard connection to peripherals such as external keyboard, mouse, printers, and barcode readers System Computer On/Off Switch - Turns the main computer system and internal analyzer components On and Off Label - Contains Power rating, serial number, and other manufacturing information I/O Ports Panel Components: PS2 Mouse Port PS2 Keyboard Port COM Port for LIS 1 - DB9 Connector COM Port for LIS 2 - DB9 Connector USB 2.0 Ports (4) - For external keyboard, external mouse, flash drive for database backups and/or storage, and software updates Ethernet Ports for LIS (2) Reagent Connectors: Diluent - Green 5P Diff - Orange Lyse - Yellow Waste Out 1 - Red Waste Out 2 - Red Describe the function of the left side internal components Pressure Sensors - Measure the differential pressures of the vacuum buffer for impedance base measurement and optical measurement Drain Buffer - Controls chamber draining Mix Chamber - Performs the first step of the RBC dilution RBC Chamber - Performs the second step of the RBC dilution and count, and contains the RBC aperture WBC Chamber - Performs the WBC dilution and count, and holds the WBC aperture and HBG photometric measurement head Valves 1 - 44 - Connected pneumatic components to perform dilution, reaction, measurement and waste disposal processes Diluent Buffers - Reservoirs for the ADVIA 360/560 Dil 20L diluent Diff and Lyse Buffers - Reservoirs for the ADVIA 560 5P Diff 1L and ADVIA 560 Lyse 5L reagents Sheath Buffer - A reservoir for the ADVIA 360/560 Dil 20L diluent for optical measurements Small Measure Buffer - A vacuum buffer used for impedance measurement Explain the function of the right side external and internal components Right Side External Component: Reagent Hardware (HW) Key Slot Used with Reagent Hardware (HW) Key as part of the Reagent Lock System The key ships with each ADVIA 560 Lyse 5P reagent and contains 900 measurement credits The system counts the number of measurements performed and warns the operator when the number of measurement credits that remain is 50 Blank, Calibration, and QC measurements are included in the overall measurement count Right Side Internal Components: Wash Head - Cleans the aspiration needle in between samples Aspiration Needle - Aspirates the blood sample from an open or closed sample tube Power Supply - Provides the system with electrical power Horizontal, Vertical Motion (XY) Unit - Positions the aspiration needle Optical Head - Contains the laser source, optical detectors, and the flowcell for optical measurement Auto-loader Connector - Powers and controls the optional Auto-loader Auto-loader (Auto-sampler) Features: Connects to the ADVIA 560 Hematology System; cannot operate independently of the system Has the ability to hold and process up to 100 blood sample tubes (10 racks each holding 10 sample tubes) The racks are specially designed to allow samples to be fed into the system and be mixed individually Racks are seated on the sample tray that can be moved back and forth by the Auto-sampler Has a power On/Off switch but power is fed through the ADVIA 560 Contains a built-in sample mixer and barcode reader allowing walk-away operation Has a transparent plastic cover equipped with a safety switch; opening the cover automatically stops Auto-loader operation Auto-loader Components: Sample Tray Base Plate Sample Tray Sample Rack Feeder Wheel Sample Racks Plexi-glass Cover Power On/Off Switch and LED Status Lights LED Status Light Indicators: Upper Light OFF - Power is off RED - cover is open GREEN - OK Lower Light OFF - Power is off RED - Error GREEN - OK Describe the components of the Graphical User Interface The software of Graphical User Interface consists is divided into three sections: Header or Top Navigation Section Main Display Area or Interactive Display Area Status Display Area The Top Navigation Section contains 5 icons: Measure - To perform blank measurements, run whole blood controls, and run patient samples AS - For facilities that have an ADVIA 560AL System, which includes the Auto-loader Database - To view all measured data including blank results, whole blood controls, and patients Print - To print data Menu - Home screen The Main Display Area or Interactive Display Area contains the following menu icons: Patient - To view patient data Exit - To perform a Shutdown or prepare the system for shipment Settings - To customize and configure the system settings Maintenance - To perform a Cleaning, Hard cleaning, Shear valve cleaning, and other maintenance tasks Calibration - To perform a calibration and view calibration history, results, and targets QC - To scan or enter QC reference data, measure control samples with statistical data, and view control sample results Diagnostics - To perform a Self-test, check reagent status, and view the instrument serial number and software version The Status Display Area consists of the following: AS (Auto-loader) status - Only available if facility has an Auto-loader connected Reagent and Waste status Green - Diluent Yellow - Lyse Orange - Diff Red - Waste Error and Warning icons Printer status Pneumatic system status Selected language and keyboard layout Current time Select Next to continue. Front Panel Front Internal Assembly Status Light Dilutors Touchscreen Shear Valve Sample Rotor Station Optical Head Unit Sample Rotor Additionally, there is a Barcode scanner that ships with the system. It can be used to scan sample and control barcodes and product IFU and reagent barcodes. Front Panel Components Learn about the location of the front panel components by selecting the image areas. Base ImageHotspotsText BlocksImage FileLCD Touchscreen with a pressure sensitive overlay - Allows selection of menu items and pressing of buttons by gently pressing or tapping the surface of the selected itemStatus light - Green (Ready), Red (Busy), Orange (Standby)Sample Rotor station and sample tube adaptor - Contains the Sample rotor and adaptor which holds open or closed sample tubes for manual processingBarcode scanner - Can be used to scan sample and control barcodes and product IFU and reagent barcodes Front Internal Components Learn about the location and function of the front internal components by selecting the image areas. Base ImageHotspotsText BlocksImage FileDilutors - Control the volume and flow rate of reagents through the pneumatic componentsShear valve - An integrated multi-functional valve for segmenting precise volumes of bloodOptical Head unit - Contains the laser source, optical detectors, and the flowcell for optical measurementSample rotor - Holds open or closed sample tubes for manual processing Back Panel I/O Ports Reagent Connectors Power Connector PS2 Mouse Port Ethernet Ports for LIS (2) Diluent Power On/Off Switch PS2 Keyboard Port USB 2.0 Ports (4) 5P Diff I/O Ports Panel COM Port for LIS 1 COM port for LIS 2 Lyse System Computer On/Off Switch Waste Out 1 Label Waste Out 2 Back Panel Components Learn about the location of the back panel connectors by selecting the image areas. Base ImageHotspotsText BlocksImage FilePower Supply Connector - Connects to grounded power outletPower On/Off Switch - Turns all of the electrical power to the system both On and OffI/O Ports Panel - Provides a standard connection to peripherals such as an external keyboard, mouse, printers and barcode readersSystem Computer On/Off Switch - Turns the main computer system and internal analyzer components On and OffLabel - Contains Power rating, serial number and other manufacturing information Reagent Connectors Learn about the location of the reagent connectors by selecting the image areas. Base ImageHotspotsText BlocksImage FileADVIA 360/560 Dil 20L (Diluent) - Green color-coded tubing connectorADVIA 560 5P Diff 1L - Orange color-coded tubing connectorADVIA 560 Lyse 1L - Yellow color-coded tubing connectorWaste Out 1 and 2 - Red color-coded tubing connectors I/O Ports Panel Components Learn about the individual components of the I/O Ports panel by selecting the image areas. Base ImageHotspotsText BlocksImage FilePS2 Mouse port for optional mousePS2 Keyboard for optional keyboardCOM Port for LIS - DB9 ConnectorEthernet Ports for LIS (2) USB 2.0 Ports for peripherals - External keyboard, external mouse, flash drive for database backups and/or storage, and software updatesCOM Port for LIS - DB9 Connector Left Side Internal Assembly Pressure Sensors Drain Buffer Mix Chamber RBC Chamber WBC Chamber Diluent Buffer Valves 1 - 44 Sheath Buffer Diff and Lyse Buffers Small Measure Buffer Left Side Internal Components Learn about the location/function of the left side internal components by selecting the image areas. Base ImageHotspotsText BlocksImage FilePressure Sensors - Measure the differential pressures of the vacuum buffer for impedance base measurement and optical measurementMix Chamber - Performs the first step of the RBC dilution and mixes the dilutionWBC Chamber - Contains the WBC aperture and HGB photometric measurement head, and performs both the WBC dilution and countValves 1 - 44 - Connected pneumatic components that perform dilution, reaction, measurement and waste disposal processesDiff and Lyse Buffers - Reservoirs for the ADVIA 560 5P Diff 1L and ADVIA 560 Lyse 5L reagentsSmall Measure Buffer - A vacuum buffer used for impedance measurementDrain Buffer - Controls chamber drainingRBC Chamber - Contains the RBC aperture and performs the second step of RBC dilution and countDiluent Buffers - Reservoirs for the ADVIA 360/560 Dil 20L diluentSheath buffer - A reservoir for the ADVIA 360/560 Dil 20L diluent used for optical measurements Internal Component External Components Wash Head Reagent Hardware (HW) Key Slot Aspiration Needle Power Supply XY Unit Optical Head Autoloader Connector Right Side Internal Components Learn about the location/function of the right-side internal components by selecting the image areas. Base ImageHotspotsText BlocksImage FileWash Head - Cleans the aspiration needle in between samplesAspiration Needle - Aspirates the blood sample from an open or closed sample tubePower Supply - Provides the system with electrical powerHorizontal, Vertical Motion (XY) Unit - Positions the aspiration needleOptical Head - Contains the laser, optical detectors, and flow cell for optical measurementAuto-loader Connector - Powers and controls the optional Auto-loader The Autoloader Learn about the Autoloader if using the ADVIA 560AL. Slide NumberText BlocksCalloutsAudio ScriptImage File1Autoloader (Autosampler) Features: Connects to the ADVIA 560 Hematology System; cannot operate independently of the system Has the ability to hold and process 100 blood sample tubes (10 racks each holding 10 sample tubes) The racks are specially designed to allow samples to be fed into the system and be mixed one by one Racks are seated on a sample tray that can be moved back and forth by the Autosampler Has a power On/Off switch, but power is fed through the ADVIA 560 Contains a built-in sample mixer and barcode reader allowing walk-away operation Has a transparent plastic cover equipped with a safety switch; opening the cover automatically stops Autoloader operation Select Next to continue.Note: If audio does not automatically start, select the play arrow to begin.The Autoloader, which cannot operate independently of the ADVIA 560 system, connects to the system via a connector on the right panel. It has the ability to hold and process 100 blood samples; 10 racks each holding 10 sample tubes. The racks are specially designed to allow samples to be mixed one by one when fed into the system. Racks are seated on the sample tray that moves back and forth by the Autoloader. Although it has its own power On/Off switch, the power is fed through the ADVIA 560 system. The Autoloader contains a built-in sample mixer and barcode reader allowing walk-away operation. A transparent plastic cover sits on top and contains a safety switch. If the cover is opened, Autoloader operation is automatically halted. Select next to continue. 2Auto-loader Components: Sample Tray Base Plate Sample Tray Sample Rack Feeder Wheel Sample Racks Plexi-glass Cover Power On/Off Switch and LED Status Lights Select Next to continue. The Autoloader contains 6 components: The sample tray base plate, sample tray, sample rack feeder wheel, sample racks, a plexi-glass cover, a power On/Off switch and LED status lights. Select next to continue. 3Status Light Indicators: Upper Light OFF - Power is off RED - Uninitialized/Interrupted (Cover open) GREEN - OK Lower Light OFF - Power is off RED - Error GREEN - OK When complete, select the X in the upper-right corner to close the window and continue.The status light indicators include an upper light and a lower light. OFF indicates that the power is off for both lights. RED, for the upper light indicates that the Autoloader is uninitialized or interrupted. For the lower light, RED indicates an error. GREEN indicates that the Autoloader is ok for both lights. When complete, select the X in the upper right corner to close the window and continue. Right Side External Component Learn about the location and function of the one right-side external component by selecting the image areas. Base ImageHotspotsText BlocksImage FileReagent Hardware (HW) Key Slot - Used with Reagent Hardware (HW) Key as part of the Reagent Lock System. The key ships with each ADVIA 560 Lyse 5P reagent and contains 900 measurement credits. The system counts the number of measurements performed and warns the operator when the number of measurement credits that remain is 50. Blank, Calibration, and QC measurements are included in the overall meausrement count. To navigate the system software or Graphical User Interface, which is divided into three sections, use the touchscreen with the on-screen keyboard or an external mouse and keyboard. Top Navigation Section or Header Main Display Area or Interactive Display Area Status Display Area You can turn off the on-screen keyboard if using an external mouse and keyboard by navigating to: Menu > Settings > Customize > Select the checkbox to deselect the on-screen keyboard The Top Navigation Section, which is the header, contains 5 menu icons that are visible during all operations: Measure AS - Autoloader Database Print Menu - Home screen Depending on which icon is selected determines what displays in the Main Display Area or Interactive Display Area. The selected icon is highlighted to indicate which menu you are in. The Main Display Area contains these Menu icons: Patient Exit Settings Maintenance Calibration QC Diagnostics The Status Display Area is at the bottom of the screen and contains: AS state Reagent and Waste container status Error and Warning icons Printer status Pneumatic system status Language and Keyboard Current time If your facility does not have an Auto-loader, your AS state icon will be greyed out. Select Next to proceed to the Course Review page. If your facility is either not using the Autoloader or it is disconnected, the AS menu icon will be greyed out.
- status light
- touchscreen
- sample rotor
- dilutors
- shear valve
- optical head
- station
- barcode scanner
- barcode reader
- power connector
- power switch
- i/o ports
- computer switch
- label
- ps2 mouse
- ps2 keyboard
- com port 1
- com port 2
- LIS
- ethernet port
- usb 2.0 port
- diluent
- 5p diff
- lyse
- waste
- pressure sensors
- mix chamber
- wbc chamber
- diff buffer
- lyse buffer
- small measure buffer
- drain buffer
- rbc chamber
- diluent buffer
- sheath buffer
- wash head
- aspiration needle
- power supply
- xy unit
- optical head
- autoloader
- auto-loader
- connector
- reagent hardware key
- slot
- hw key
- GUI
- graphical user interface
- software
- top navigation section
- header
- main display area
- interactive display area
- status display area
- menu
- icons
- measure
- AS
- database
- patient
- exit
- settings
- maintenance
- calibration
- qc
- diagnostics
- AS state
- reagent and waste container status
- error and warning icons
- printer status
- language and keyboard
- current time
- front
- top
- internal
- external
- back panel
- reagent connectors
- right side
- left side
- olt