ADVIA® Automation Solutions Sample Processing Online Training
Load sample tubes, trace the path of a sample tube through the system, use the search feature to find samples on the system, and assign completed sample trays to cold storage. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the ADVIA® Automation Sample Processing Online Training. Sample Processing on the ADVIA Automation includes: Sample loading Appropriate routing to analytical instruments Sample unloading Select Next to continue. Assign completed sample trays to cold storage Describe how the sample travels through the automation system Locate samples with pending test requests Recognize proper sample loading procedures Utilize the search feature of the LineMaster workspace to locate samples on the automation system Upon successful completion of this course, you will be able to: Select Next to continue. How do samples get placed into pucks? Sample tubes are loaded into a Sample Tray beginning with position A1 Samples are loaded left to right to position A10, then moving to position B1 Sample Trays are loaded into the Sample Manager Sample Manager Robot moves the tubes from the Sample Tray to individual pucks Tube Types Learn about acceptable tube types. The puck transports sample tubes of varying diameters and heights. Some acceptable tube details are: Tube Diameter: 11.5mm to 16.2mm Tube Height: 75mm to 100mm Cap Type: Hemogard, Classic Vacutainer, Screw Cap Tube Composition: Glass or Plastic Note: For Decapper or CXL installed systems refer to the ADVIA® Automation Solutions Operator’s Manual for specific tube. When complete, select the X in the upper-right corner to close the window and continue. The Sample Manager: Identifies the sample tray when the drawer is closed Robot moves samples from the sample trays to the track Robot moves the samples from the track to the appropriate unload type tray after processing is complete Sample Manager Tube Processing Learn how the Sample Manager handles sample loading and unloading. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90002509/startrun_GM2_9/startrun_GM2_9.swfHTML5 File:/content/generator/Course_90002509/startrun_GM2_9/index.htmlPDF File: We have now had an overview of how a sample travels through the automation system. Let’s examine the process in more detail. Tube Journey Learn more about the sample tube processing sequence. Select the play arrow to begin the video. When complete, select the X in the upper-right corner to close the window and continue. The Sample Query screen holds all sample information for 7 days and is used to search for a sample. It can indicate whether the sample is: On the track At an instrument In the Sample Manager In Cold Storage Not yet loaded on the automation system Sample Query Screen Learn about the Sample Query screen. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90002509/samplequery_GM2_9/samplequery_GM2_9.swfHTML5 File:/content/generator/Course_90002509/samplequery_GM2_9/index.htmlPDF File: Placing an Unload tray in Cold Storage is simple: Remove the Unload tray from the Sample Manager; the LineMaster automatically creates a Cold Storage entry for the tray. Place the Unload type tray in Cold Storage Update the Cold Storage screen in the LineMaster with specific location of the tray Assigning Cold Storage Learn how to assign a tray to Cold Storage. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90002509/sim_AA_ColdStorage-2_9/sim_AA_ColdStorage-2_9.swfHTML5 File:/content/generator/Course_90002509/sim_AA_ColdStorage-2_9/index.htmlPDF File: Samples on the Pick List: Have additional test requests that are pending, and Have already been removed from the automation system, such as samples placed in Cold Storage Finding Samples on Pick List Learn how to locate samples on the Pick List. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90002509/Picklist_GM2_9/Picklist_GM2_9.swfHTML5 File:/content/generator/Course_90002509/Picklist_GM2_9/index.htmlPDF File: Congratulations. You have completed the ADVIA® Automation Sample Processing online training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. In this online training course, you have learned to: Recognize proper sample loading procedures Describe how the sample travels through the automation system Utilize the search feature of the Sample Manager to locate samples on the automation system Assign completed sample trays to Cold Storage Locate samples with pending test request Select Next to continue.
- ADVIA
- automation
- track
- sample
- processing
- workcell
- labcell