ADVIA Centaur® CP Immunoassay System Additional Worklist Functions Online Training
Additional worklist functions includes scheduling repeats, replicates, and dilutions. This clinical laboratory training qualifies for continuing education units (CEU).
In emergency diagnostic situations, physicians order tests to quickly evaluate the patient’s metabolic functions. Key tests include measuring the metabolites glucose and lactate. Different measuring methods are available for testing blood glucose and lactate-factors include sample type and area of application. Welcome to the ADVIA Centaur® CP Additional Worklist Functions Online Training course. The procedures covered in this course include: Schedule manual and system-performed sample dilutions Schedule replicate tests Create test profiles Add patient demographics Schedule a batch Select Next to continue. Add patient demographics Create test profiles Schedule batches Schedule dilutions Schedule replicate tests Upon successful completion of this course, you will be able to: Select Next to continue. In this section, we'll interact with the syngo Lab Data Manager software. You will be able to log into the system, identify the screen layout, and launch applications. To find out more about each task, select the links below. Congratulations. You have completed the Additional Worklist Functions online training course. Listed below are the key points that have been presented. Take time to review the material as needed before proceeding to the final quiz. Schedule Dilutions: Automatic scheduling by the ADVIA Centaur® CP based upon laboratory specific criteria System-performed dilutions are scheduled in the Sample Compartment window Select sample, select assay, select Dilute, choose assay, select dilution factor, deselect Undiluted. Manual dilutions are scheduled in the Sample Compartment window. Select sample, select Dilute, enter dilution factor, Close Dilutions, select assay. Schedule Replicate Tests: Scheduled in the Sample Compartment window Select sample, select assay, select Replicates, choose assay, enter replicates Schedule Batches: Scheduled in the Sample Compartment window Select rack, select Enable Batches, choose assays, select Disable Batches Create Test Profiles: Created in the Setup window Select Setup, select Profile Definition, select Add Profile, enter profile name and LIS code, select assays, select Save Add Patient Demographics: Entered in the Schedule Worklist window in Results Select Results, select Schedule Worklist, enter SID and demographic information, select assay, select OK Select Next to continue. Sample Dilutions Automatic dilutions - Setup in the software to automatically schedule a dilution if the original result is greater than the concentration limit System-performed dilutions - Dilution performed by the system using an onboard diluent and scheduled in the Sample Compartment or Schedule Worklist window Manual dilutions - Dilution prepared on the bench and scheduled in the Sample Compartment or Schedule Worklist window Dilution profile - Multiple dilutions scheduled for a test Note: You must dilute all samples with the correct ADVIA Centaur CP diluent specified for each test. Refer to the assay Instructions for Use (IFU) for more information. System-performed dilutions Learn how to schedule system performed dilutions. Checklist TitleChecklist TypeChecklist ContentSelect Sample CompartmentHTML Select the Sample Compartment from the workspace. Select each checkbox to learn more about scheduling system-performed dilutions.Select SampleHTML Select the sample that requires a dilution.Select TestHTML Select the test and press the Dilute button.Select Test AgainHTML Select the test.Choose Dilution FactorHTML Select the dilution factor. Note: If an sXX appears in the dilution factor button, this indicates the sample size that will be used for the dilution. If no sXX appears, the system uses the default sample size for the dilution.Deselect UndilutedHTML Deselect the Undiluted button. This option is selected by default. If left selected, the system would run the sample straight in addition to the dilution.Select CloseHTML Select Close Dilutions if more sample scheduling is required. Select Close if scheduling is complete.Review OrderHTML Select Results from the Task bar. Observe the dilution order. The type of dilution and dilution factor are displayed on the right side of the window. When complete, select the X in the upper-right corner to close the window and continue. Manual dilutions Learn how to schedule manual dilutions. Checklist TitleChecklist TypeChecklist ContentSelect Sample CompartmentHTML Select the Sample Compartment from the workspace. Select each checkbox to learn more about scheduling manual dilutions.Select SampleHTML Select the sample. The sample ID must be different than the original accession number.Select DiluteHTML Select Dilute.Enter Dilution FactorHTML Enter the manual dilution factor.Close DilutionsHTML Select the Close Dilutions button.Select TestHTML Select the test. Select the Close button.Review OrderHTML Select Results from the Task bar. Observe the manual dilution order. The dilution type and dilution factor are listed on the right side of the window. When complete, select the X on the upper-right corner of the window to continue. Dilution profile Learn how to setup a dilution profile. Checklist TitleChecklist TypeChecklist ContentSelect SetupHTML Select the Setup button from the Task bar. Select each checkbox to learn more about creating a dilution profile.Select Profile DefinitionHTML Select the Profile Definition tab.Select Add Dilution ProfileHTML Select the Add Dilution Profile button.Enter Profile NameHTML Enter the profile name and LIS code.Select TestHTML Select the test.Select Dilution FactorsHTML Select the dilution factors.Select SaveHTML Select Save. This dilution profile can be ordered in the Sample Compartment window. When complete, select the X in the upper-right corner to close the window and continue. You have just learned about scheduling dilutions. Select the link below to practice what you have learned. System-performed Dilution Practice scheduling a system-performed dilution. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003342/sim_CP_SystemDilns800x600_9/sim_CP_SystemDilns800x600_9.swfHTML5 File:/content/generator/Course_90003342/sim_CP_SystemDilns800x600_9/index.htmlPDF File: Replicates can be scheduled when performing precision studies. To Schedule Replicates: Select Sample Compartment Select sample Select test Select Replicates Select test Enter replicates Select Close Replicates Schedule Replicates Learn how to schedule replicates. Checklist TitleChecklist TypeChecklist ContentSelect Sample CompartmentHTML Select the Sample Compartment from the workspace. Select each checkbox to learn more about scheduling replicates.Select SampleHTML Select the sample.Select TestHTML Select the test.Select ReplicatesHTML Select the Replicates button.Select TestHTML Select the test in the Selected Requirements area.Enter ReplicatesHTML Use the up and down arrows next to the Replicates field to increase or reduce the replicate number or use the keyboard to enter the number of replicates.Select CloseHTML Select Close Replicates if more scheduling is required. Select Close if scheduling is complete.Review ResultsHTML The mean of the replicate tests will be displayed in the Today's tab. You can view the individual replicate tests by highlighting the results and selecting the Details button.Review Result DetailsHTML Review the individual replicates in the Result Details window. When complete, select the X in the upper-right corner to close the window and continue. The light tower is a visual indicator of system status. There are four color indicators on the light tower; red, yellow, white, and green. Select the link below to learn about the light tower. Batches can be used when the LIS is down and the same test(s) needs to be ordered on multiple samples. To Schedule a Batch: Select Sample Compartment Select rack Select Enable Batches Select test(s) Select Disable Batches Schedule a Batch Learn how to schedule a batch. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003342/sim_CP_Batch800X600_9/sim_CP_Batch800X600_9.swfHTML5 File:/content/generator/Course_90003342/sim_CP_Batch800X600_9/index.htmlPDF File: Individual samples that cannot be processed due to specific issues do not generate colored status bars. Instead these samples are routed to a Sample in Question gate or tray. These locations are referred to as SIQ. Examples of sample issues are sample not properly checked in, unreadable barcode labels, duplicate samples, sample integrity errors and no workorder. After a sample is diverted to the SIQ location, the operator must determine the problem. This information is in the SIQ screen. Select the link below to learn how to access and determine errors in the SIQ Screen. Test Profiles: Can be used to schedule patients when the LIS is not available Are scheduled in the Sample Compartment window Are created in the Setup window Create a Test Profile Learn how to create a test profile. Checklist TitleChecklist TypeChecklist ContentSelect SetupHTML From the workspace, select the Setup task button. Select each checkbox to learn more about creating a test profile.Select Profile DefinitionHTML Select the Profile Definition tab.Select Add ProfileHTML Select the Add Profile button.Enter Profile NameHTML Enter the profile name and LIS code.Select AssaysHTML Select the assays to be included in the profile.Select SaveHTML Select Save.Select CloseHTML The new profile is now listed in the Profile Definition window. Select Close to return to the workspace. When complete, select the X in the upper-right corner to close the window and continue. Practice creating a profile Practice creating a test profile. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003342/sim_CP_testProfile800x600_9/sim_CP_testProfile800x600_9.swfHTML5 File:/content/generator/Course_90003342/sim_CP_testProfile800x600_9/index.htmlPDF File: Samples with integrity issues will be diverted to the SIQ location. Examples of these issues are insufficient sample or clot detected. Inspect the sample tube to determine further action. If the sample can be processed, reintroduce it to the system. Patient demographic information can be entered: When the LIS is not available In the Schedule Worklist window in Results Before, during or after samples are processed Entering Demographics Learn about entering patient demographics. Checklist TitleChecklist TypeChecklist ContentSelect ResultsHTML From the workspace, select the Results task button. Select each checkbox to learn more about entering patient demographics.Select Schedule WorklistHTML Select the Schedule Worklist button.Enter DemographicsHTML Enter SID and demographic information.Select AssaysHTML Select assay(s).Select OKHTML Select OK. When complete, select the X in the upper-right corner to close the window and continue. Entering Demographics Practice entering patient demographics. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003342/sim_CP_Demograph800x600_9/sim_CP_Demograph800x600_9.swfHTML5 File:/content/generator/Course_90003342/sim_CP_Demograph800x600_9/index.htmlPDF File:
- centauro
- centuar
- cenuarcp
- centaurcp
- centaurocp
- centuarcp
- cenatur
- cenaturcp
- cen
- cencp
- centar
- centarcp
- centau
- centauer
- centauercp
- centure
- centurecp