ADVIA Centaur® CP Immunoassay System Supplies and Reagent Management Online Training

Supplies and reagent management includes loading supplies and reagents, and emptying waste to ensure efficient use of the ADVIA Centaur® CP. This clinical laboratory training qualifies for continuing education units (CEU).

Welcome to the ADVIA Centaur® CP Supplies and Reagent Management course. The pre-analytical procedures covered in this course include: Replacing the acid and base reagents Refilling the de-ionized water and Wash 1 containers Loading sample tips and cuvettes Loading primary and ancillary reagent packs Emptying the solid and liquid waste containers   Select Next to continue. Describe how to empty solid and liquid waste containers Identify how to load sample tips and cuvettes Identify the steps for replacing acid and base reagents Recognize how to load primary and ancillary reagents Identify how to refill the DI water and Wash 1 containers Upon successful completion of this course, you will be able to: Select Next to continue. Congratulations. You have completed the Supplies and Reagent Management online training course. Listed below are the key points that have been presented. Take time to review the material before proceeding to the final quiz.In this online training course, you have learned to: Identify the steps for replacing acid and base reagents Make sure the system is in the Ready state Lift the acid and base compartment door and remove the acid and base bottles Write the date on the new acid and base bottles and place on the system Close the acid and base compartment door Respond to messages on the software Recognize how to refill the DI water and Wash 1 containers Make sure that the system is in the Ready state Disconnect the tubing and sensor from the container Empty contents and refill container with appropriate fluid Connect the tubing and sensor Identify how to load sample tips and cuvettes Sample Tips Remove strap and separate trays Open tip drawer Position tip tray in drawer with notch toward the back Discard tip tray cover and lock tip tray in position Close tip drawer and assign tips in software Cuvettes Open bag of cuvettes and load into cuvette loading bin Select Restart Cuvette Loader in Supplies if the system detected an empty cuvette supply Recognize how to load primary and ancillary reagents Primary Reagents Mix reagent pack Open reagent compartment door Load pack in blinking green LED location Pull reagent holder toward you, place the pack on the holder and push back Close reagent compartment door Verify reagent details in the primary reagent window Ancillary Reagents Invert ancillary pack Open reagent compartment door Remove ancillary tray and place ancillary pack in the tray Load ancillary tray into a blinking green location Verify reagent details in the ancillary reagent window Close the reagent compartment door Describe how to empty solid and liquid waste containers Liquid Waste Make sure the system is in Ready Disconnect the tubing and sensor from the container Empty contents and reconnect tubing and sensor Solid Waste Make sure the system is in Ready Open the solid waste drawer and dispose of contents Replace the drawer and respond to the message in the software Select Next to continue.     Acid and Base Reagents are replaced when: The sensors detect an insufficient volume The reagents have passed the expiration date The reagents have exceeded the onboard stability period of 28 days Note: Acid and base reagents can only be replaced when the system is in Ready. Replacing Acid and Base Reagents Checklist Learn about replacing the acid and base reagents. Checklist TitleChecklist TypeChecklist ContentReview Supplies WindowHTML The supplies button will flash yellow when the acid and base reagent are 80% empty.  When the Supplies window is opened, the number of tests remaining in each bottle is displayed.  Select each checkbox to learn more about replacing acid and base reagents.Start a Sample RunHTML If you select the Start button to begin a sample run, the system checks the acid and base reagent volumes against the number of tests ordered.  If there is not enough acid and base reagent to complete the tests, the system will display the message: Volume of Acid and Base is not sufficient to complete the worklist; it is short by n tests.  Do you want to start processing samples? If you select OK, the system will initialize and process as many tests as possible with the available acid and base reagent. If you select Cancel, the system will return to the Ready state.Lift DoorHTML To replace the acid and base reagents on the ADVIA Centaur® CP, lift the compartment door on the left side of the analyzer. This exposes the acid and base reagent bottles. Note: The system should be in the Ready state before performing this procedure.Remove ReagentsHTML Notice that the acid reagent, R1, on the left has a light gray label and the base reagent, R2, on the right, has a white label. Lift the old reagent bottles out, and dispose of the remaining reagent according to your laboratory’s policy. Then, dispose of the old reagent bottle in an appropriate receptacle.Prepare New BottlesHTML Open the packaging, and obtain a new bottle of each of the reagents.  Write the current date on each.Replace ReagentsHTML Remove the caps, and place the new bottles in the compartment with the acid reagent bottle (R1) on the left and the base reagent bottle (R2) on the right.    CAUTION: Ensure that the acid and base reagent bottles are installed in the correct positions. If reversed, the chemiluminescent reaction will not occur correctly. After you have replaced the reagents in their proper locations, close the acid/base compartment door. Respond to MessageHTML Each time you open and close the acid and base compartment door, a message displays as follows: Did you replace the Acid and Base bottles? If you select Yes, the window closes and the system resets to the default value of tests. If you select No, the window closes and the number of tests available remains the same. When complete, select the X in the upper-right corner to close the window and continue. The ADVIA Centaur® CP system containers: Waste container with the red cap DI Water container with the blue cap Wash 1 container with the white cap  .   DI Water Refill Learn about refilling the DI water container. Checklist TitleChecklist TypeChecklist ContentReview SuppliesHTML If the DI Water container is running low, the supplies button will flash yellow.  When the Supplies window is opened, the DI Water field will be highlighted yellow. Select each checkbox to learn more about Refilling the DI Water Container.Disconnect TubingHTML Disconnect the tubing from the container and place the tubing on a lint-free tissue or gauze to absorb drips. Note: Do not disconnect fluid or sensor lines from the DI water container if the system is processing samples.Disconnect SensorHTML Next, disconnect the sensor by turning the connector between the two ends of the sensor counter-clockwise, and then pulling the sensor ends apart. Remove Cap and EmptyHTML Remove the cap on the container, and empty the contents of the container.Refill and ReinstallHTML Refill the contents of the container, and replace the cap. Position the container in its location, and reconnect the tubing and the sensor.  When complete, select the X in the upper-right corner to close the window and continue.   Wash 1 Refill Learn about refilling the Wash 1 container. Checklist TitleChecklist TypeChecklist ContentReview SuppliesHTML If the Wash 1 Container is running low, the Supplies button will flash yellow.  When the Supplies window is opened, the Wash 1 field will be highlighted yellow. Select each checkbox to learn more about Refilling the Wash 1 Container.Disconnect TubingHTML Disconnect the tubing from the Wash 1 container and set it aside on lint-free tissues or gauze to absorb drips. Note: Do not disconnect fluid or sensor from the Wash 1 container if the system is processing samples.Disconnect SensorHTML Next, disconnect the sensor by turning the connector between the two ends of the sensor counter-clockwise and then pulling the sensor ends apart.Remove Cap and EmptyHTML Remove the cap on the container and empty the contents.Refill ContainerHTML Pour Wash 1 fluid into the container.Reinstall ContainerHTML Position the container in its location and reconnect the tubing and sensor. When complete, select the X in the upper-right corner to close the window and continue. The ADVIA Centaur® CP system uses two tip drawers: Each drawer accommodates two tip trays Each tray has 120 tips Total capacity of 480 disposable tips Select Next to continue. To replace a tip tray: 1.  Withdraw the tip tray in the software (if needed) and remove the empty tip tray 2.  Load the new tip tray 3.  Assign the trays in the workspace Load Tip Tray Checklist Learn how to load a new tip tray. Checklist TitleChecklist TypeChecklist ContentWithdraw Tip TraySimulationInstructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003357/sim_CP_WithdrawTray800x600_9/sim_CP_WithdrawTray800x600_9.swfHTML5 File:/content/generator/Course_90003357/sim_CP_WithdrawTray800x600_9/index.htmlPDF File:Remove Strap and Separate TraysHTML To prevent contamination of the tips when handling, take care to rest the tips on a clean surface. Place a single tip tray in each position in the tip tray drawer.   Position Tips in DrawerHTML Ensure that all tips fit in the drawer and the notch on the tray is positioned correctly next to the orientation tab in the drawer. Discard Tip Tray CoverHTML Remove the tip tray cover by sliding the cover toward you and then lifting it up off the tray.Lock the Tray in PositionHTML After removing the tray cover, secure the tray in position by pressing downward until the tray locks into place.  Close Tip DrawerHTML Close the tip drawer.Assign TipsSimulationInstructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003357/sim_CP_AssignTips800x600_9/sim_CP_AssignTips800x600_9.swfHTML5 File:/content/generator/Course_90003357/sim_CP_AssignTips800x600_9/index.htmlPDF File: Estes ensaios são diferentes de outros nos quais as esferas não são específicas para uma imunoglobulina de um alérgeno em particular. Os ensaios de alergia dosam a quantidade de imunoglobulina para um alérgeno específico no soro de um paciente. Selecione o link abaixo para saber mais sobre ensaios de alergia. Loading cuvettes is required when the instrument does not detect the presence of cuvettes or the loading bin is running low. Cuvettes are packaged in bags containing 200 cuvettes each.   The cuvette loading bin holds up to 400 cuvettes. Load Cuvettes Checklist Learn how to load sample cuvettes. Checklist TitleChecklist TypeChecklist ContentLoad the cuvettes in the cuvette loading binHTML You can load cuvettes at any time, even while the system is processing samples. If the system has not run out of cuvettes, just load the cuvettes in the cuvette loading bin for continuous processing. Note: Do not to overfill the cuvette bin.  Overfilling the bin can cause cuvette jams.  Select each checkbox to learn more about Loading Sample Cuvettes.Select the Supplies status buttonHTML If the system detects an empty cuvette supply, the cuvette loader must be restarted after loading the cuvettes. To do this, select the flashing red Supplies button at the workspace. Select Restart Cuvette LoaderHTML The Cuvette Hopper field will be red when the cuvette supply is empty. After loading the cuvettes, select the Restart Cuvette Loader button to prime the cuvettes. The final step is to close the Supplies window by selecting the Close button. When complete, select the X in the upper-right corner to close the window and continue. Existem dois tipos de controles para os ensaios de alergia. Os controles encontrados na caixa do kit IgE Alérgeno Específico de 3ª Geração são específicos para controles do kit de IgE, que monitoram a integridade do kit universal. O outro tipo de controles de alergia são controles específicos para alérgeno que monitoram a integridade de alérgenos específicos. Selecione o link abaixo para saber sobre a execução de controles de alergia. Primary Reagents: Mix by hand to resuspend the paramagnetic particles of the Solid Phase reagent Load the primary reagent pack into the reagent compartment after mixing If you remove reagents from the reagent compartment, cover the pierced area with self-sealing laboratory film Use caution when mixing pierced primary reagent packs to avoid spills Note:  CEA, aHBs and H2n require special primary reagent handling.  Refer to Instructions for Use for more details. Storage of reagents: Protect from light, keep refrigerated and keep upright.   loading reagents Slideshow Learn how to load primary reagents. Slide NumberText BlocksCalloutsAudio ScriptImage File1 Mix primary reagents before loading: Raise one end of the pack to a 90 degree angle and return to a horizontal position Raise the other end of the pack to a 90 degree angle and return to a horizontal position Repeat at least 20 times or until the paramagnetic particles are no longer visible on the bottom of the pack Special mixing required for CEA, aHBs and Her-2/neu:  Shake back and forth vigorously for 15 seconds Tap the pack on the bench 5 times Select Next to continue. Note: If audio does not automatically start, select the play arrow in the top left to begin.The first step in loading primary reagents is mixing the reagent pack. Some reagents require mixing end to end at a 90 degree angle 20 times while others require vigorous shaking. Refer to the assay instructions for use for assay-specific reagent handling procedures.2 Load the reagent pack: Load in the blinking green LED lane Barcoded end of the pack loaded first Indentation in the reagent pack should fit securely on the tab Select Next to continue. After the reagent pack has been mixed, open the reagent compartment door. You will notice that the primary reagent compartment window automatically opens on the software. The reagent pack should be loaded in the lane that has a blinking green LED. To load the pack, pull the reagent holder toward you. Place the pack on the reagent holder, inserting the barcoded end of the pack first. The bottom of the reagent pack has an indentation that fits over the tab in the reagent holder. Ensure that the indentation in the reagent pack fits correctly on the tab.3 Push reagent holder back Press down on the pack to ensure proper placement Barcode scanner reads pack Blinking LED turns to neutral is pack was scanned successfully Repeat these steps until all primary reagents are loaded. Close the reagent compartment door when loading is complete.  When the compartment door is closed, the window on the software also closes.   Select Next to continue. Push the reagent holder back and gently press down on the top of the pack to ensure it is correctly seated on the reagent holder. The barcode is scanned after the reagent holder is in place. If the pack was read successfully, the blinking green LED turns to neutral. The blinking green LED will automatically move to the next available location and you can continue to load more packs if necessary. When loading is complete, close the reagent compartment door.4 Confirm reagent details: Open Primary Reagent Compartment screen Verify reagent details If the system did not recognize a barcode: ??? will be displayed LED above lane will be blinking yellow Remove pack and reload in next available blinking green position When complete, select the X in the upper-right corner to close the window and continue.Next, open the primary reagent compartment window to confirm reagent details. If a pack was not loaded successfully, you will see question marks in the lane where the pack is located. The LED above that lane will be blinking yellow. To resolve the problem, remove the pack by pulling the reagent holder toward you. Place the pack in the next available blinking green location. O sistema ADVIA de automação mantém os dados das amostra por 7 dias. Após esse período, você deve remover as bandejas expiradas da soroteca e descartar as amostras. Limpar todos os respindos de amostra das bandejas com um pano umedecido com hipoclorito a 10% e, em seguida, limpar com água para remover a solução de hipoclorito quando necessário. Os cinco códigos de barras, na parte superior e nas laterais da bandeja, devem estar em boas condições. Ancillary Reagents: Mix ancillary reagent packs by hand before loading them onto the system Load ancillary reagents onto an ancillary tray Load the ancillary tray into the ancillary reagent area If ancillary reagents are removed from the system, cover the pierced area with self-sealing laboratory film Use caution when mixing pierced ancillary reagent packs Note: Certain methods require ancillary preparation.  Refer to Instructions for Use for more details. Storage of reagents: Protect from light, keep refrigerated and keep upright.   Load Ancillary Reagents Checklist Learn how to load ancillary reagents. Checklist TitleChecklist TypeChecklist ContentRemove tray from reagent compartmentHTML Open the reagent compartment door and remove an ancillary tray.  When you remove the ancillary tray, the ancillary reagent window will display on the software. Select each checkbox to learn more about Loading Ancillary ReagentsLock ancillary reagent packs into positionHTML Position the reagent so that the barcode on the pack faces the same direction as the barcodes on the tray. Slide the pack into position, and push the pack forward until it snaps into place Load Ancillary TrayHTML As with Primary reagents, the blinking green LED indicates the position that is ready to accept the reagent tray. Slide the ancillary tray into the ancillary reagent area, using one continuous motion. The reagent barcodes are read as the tray is inserted into the system. If the tray stops or reverses during insertion, the system may read the barcodes incorrectly. If the tray was read correctly, the blinking green LED turns to neutral.Confirm or edit reagent detailsHTML When the barcode information has been read, the Ancillary Reagent screen displays the reagent details. Confirm that the reagent details have been read on the Ancillary Reagent screen.  If an ancillary tray was not read successfully, ??? will appear in that location. Remove the tray and reload in a blinking green position. If the instrument barcode reader does not register the barcode, the pack position will not display the reagent information on the screen. Like primary reagents, ancillary reagents can also be entered manually.Close reagent compartment doorHTML  When ancillary reagent loading is complete, close the reagent compartment door.  The ancillary reagent screen on the software will also close. When complete, select the X in the upper-right corner to close the window and continue. Existem quatro procedimentos de manutenção realizados mensalmente: Inspecionar os Gates, Manutenção dos Puck, Contagem do total de Pucks e backup manual do software. A Manutenção dos Pucks é um procedimento de limpeza. Neste curso, será apresentado como desmontar o puck com a ferramenta de manutenção e limpá-los com hipoclorito 10%. No entanto, esse procedimento só deve ser feito quando orientado pela Equipe Siemens. Na rotina, basta limpar os pucks externamente com hipoclorito 10%. A Contagem do total de Pucks é necessária para garantir que o sistema tenha um controle preciso no número de pucks. Os pucks devem ser contados manualmente e essa informação deve ser inserida na tela Global Router Settings (Ctrl F6) O Backup do sistema pode ser agendado para ser executado automaticamente ou pode ser iniciado e realizado manualmente. É recomendado que esse backup seja realizado mensalmente ou após a mudança de alguma configuração do sistema. De acordo com solicitação da Equipe Siemens, pode ser necessário que o backup seja realizado semanalmente. Os materiais necessários para executar essas manutenções e procedimentos estão listados. Empty the liquid waste container: At the beginning of each day Before extended operation When the system notifies you that the container is 80% full Before performing this procedure, ensure that the system is in the Ready state and not actively processing samples. NOTE:  Wear personal protective equipment.  Use universal precautions. Empty Liquid Waste Checklist Learn how to empty the liquid waste container. Checklist TitleChecklist TypeChecklist ContentDisconnect the tubing from the containerHTML Detach the waste line tubing from the container by turning the blue portion of the connector counterclockwise. Place the tubing on a lint-free tissue or gauze to absorb any drips. Select each checkbox to learn more about Emptying the Liquid Waste Container. Disconnect the sensorHTML Next, disconnect the sensor. Turn the connector between the two ends of the sensor counterclockwise and pull the two ends apart. The container is now disconnected from the system. Open SpigotHTML Open the spigot on the container and empty the contents of the container according to your laboratory’s procedures.Reinstall containerHTML Replace the cap on the container and place the container back in position. Reconnect the waste tubing to the container, and reattach the two ends of the sensor.  When complete, select X in the upper-right corner to close the window and continue. Um valor de pH de 7 refere-se à um pH neutro. Soluções com um pH inferior a 7 refere-se à pH ácidos e soluções com um pH superior a 7, são referidos como base. O pH do corpo deve ser mantida dentro de um intervalo estreito. A maioria dos sistemas do corpo funcionam otimamente à um pH próximo de 7,4. The solid waste drawer: Is located under Tip Drawer #2 and the sample compartment Holds waste for 400 tests Should be emptied at the beginning of the day and before extended operation It is recommended to empty the drawer when the instrument is in the Ready state to avoid potential biohazardous conditions. Note:   Wear personal protective equipment.  Use universal precautions. Solid Waste Checklist Learn how to empty the solid waste drawer. Checklist TitleChecklist TypeChecklist ContentRemove drawerHTML Begin to empty the solid waste by removing the waste drawer. Select each checkbox to learn more about Emptying the Solid Waste Container.Dispose of contents and replace drawerHTML Inside the waste drawer are used tips and cuvettes. Dispose of the contents of the drawer properly. Select Solid Waste Emptied buttonHTML When the solid waste drawer is replaced, the Waste window automatically opens. Select the Solid Waste Emptied button to update the waste capacity in the software. Select the Close button to exit this window.  When complete, select the X in the upper-right corner to close the window and continue.

  • ancillary
  • primary
  • acid
  • base
  • water
  • wash 1
  • cuvettes
  • sample tips
  • centauro
  • centuar
  • cenuarcp
  • centaurcp
  • centaurocp
  • centuarcp
  • cenatur
  • cenaturcp
  • cen
  • cencp
  • centar
  • centarcp
  • centau
  • centauer
  • centauercp
  • centure
  • centurecp