ADVIA Centaur® XPT System Sample Processing Online Training
Sample processing includes processing patient samples and monitoring sample status and results. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the ADVIA Centaur® XPT System Sample Processing Online Training course. In this course, you will learn how to: Process patient samples using the LIS Order patients if the LIS is not operational Monitor sample status and results Transmit results to the LIS Print or export reports to keep for your records Select Next to review the course objectives. Describe how to monitor sample status and results Describe how to print patient reports Describe how to process patient samples List the steps to export results List the steps to transmit results to the LIS Upon successful completion of this course you will be able to: Select Next to continue. Khi proton hydro tiếp xúc với từ trường mạnh, chẳng hạn như máy MR, proton không còn hoạt động như kim la bàn. Thay vào đó, proton bắt đầu chuyển động giống như một con quay. Trọng lực tạo ra một mô-men xoắn trên proton quay trong khi từ trường tạo ra một mô-men xoắn trên mô-men từ. Các lực đồng thời này làm cho proton chuyển động xung quanh trục từ trường. Thuật ngữ chuyển động spin được sử dụng để mô tả cách trục quay của proton di chuyển theo hình nón về hướng trọng lực. Congratulations. You have completed the ADVIA Centaur® XPT System Sample Processing Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Describe how to process patient samples Patient tests can be ordered by: The LIS - the system requests orders from the LIS when samples are loaded into the Inprocess Queue Manual Entry - used by the operator when the LIS is not operational or for non-barcoded sample tubes The steps for processing patient samples: Load racks onto the Sample Entry Queue Press the Start button on the system The system loads the racks into Inprocess Queue and processing begins When sampling is complete, the system loads the racks into the Exit Queue Options for processing STAT patient samples: LIS - STAT orders received are given priority over routine samples STAT Entry - Samples are given priority over samples loaded onto the Sample Entry Queue STAT button in Create Patient Orders screen - Enter the SID and select the STAT button Sample Dilutions Automatic Dilutions – Dilutions that are setup in the software to automatically order a dilution if the original result is greater than the concentration limit System-Performed Dilutions – Dilutions performed by the system using an onboard diluent and ordered in the Create Patient Orders screen Manual Dilutions – Dilutions prepared on the bench and ordered in the Create Patient Orders screen Dilution Profile – Multiple dilutions ordered for a test Note: You must dilute all samples with the correct ADVIA Centaur® XPT system diluent specified for each test. Refer to the assay Instructions for Use (IFU) for more information. Test Profiles Tests may be grouped into profiles Profiles can be used to schedule patients when the LIS is not available Ordering tests by batch mode: Order multiple tests on a group of barcoded samples Use when the LIS is not available or for a group of samples not being processed through the LIS Order a batch in the Create Batch Orders screen Describe how to monitor sample status and results View Pending Orders Screen: Displays pending test orders that have not yet started processing Test Results Overview Screen: Displays in progress orders and results Option to monitor tests using the Watchlist feature Dashboard Screen: Posts a quick view of samples and tests by their current state Describe how to print patient reports Reports can be printed for: Today's Results Results displayed on the Test Results Overview screen Custom result reports To print a result report, use the Print button on the Test Results Overview screen. List the steps to transmit results to the LIS Transmitting results to the LIS: Patient and control results can be manually retransmitted to the LIS Use the Transmit button in the Test Results Overview screen List the steps to export results Exporting results: Control and patient results can be exported to a CD or USB drive Use the Export button in the Test Results Overview screen Select Next to continue. The Patient tab displays the following calculated risks: Age risk Biochemical risk for Trisomy 21 A combined risk of biochemical risk and nuchal translucency measurement for Trisomy 21 Biochemical risk for Trisomy 13/18 in the first trimester and Neural tube defects and biochemical risk for Trisomy 18 in the second trimester For example, in order to calculate the neural tube defect risk, you must enter an AFP test result. However, you cannot calculate the neural tube defect risk during screening in the first trimester, because AFP can be measured only in the second trimester. In order to calculate combined risk, you must enter a nuchal translucency value measured by a qualified sonographer, as well as a CRL measurement. When a risk is below the cut-off value, it is considered a low risk. The PRISCA software highlights this value in green. When a risk is above the cut-off value, it is considered a high risk. The PRISCA software highlights this value in red. These values are configurable and can be modified in Settings > Configuration > Cut Off Level. Patient tests can be ordered by: The LIS - the system requests orders from the LIS when samples are loaded into the Inprocess Queue Manual Entry - used by the operator when the LIS is not operational or for non-barcoded sample tubes The steps for processing patient samples: Load racks onto the Sample Entry Queue Press the Start button on the system The system loads the racks into Inprocess Queue and processing begins When sampling is complete, the system loads the racks into the Exit Queue Manually Ordering Patients by SID Learn how to manually order patients by Sample Identification Number (SID). Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_OrderingPatients_800x600_9/sim_CXPT_OrderingPatients_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_OrderingPatients_800x600_9/index.htmlPDF File: Entering SID for Non-Barcoded Samples Learn how to enter SID information for non-barcoded samples. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_EnteringSIDForNonBarcoded_800x600_9/sim_CXPT_EnteringSIDForNonBarcoded_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_EnteringSIDForNonBarcoded_800x600_9/index.htmlPDF File: Options for processing STAT patient samples: LIS STAT Entry STAT button in Create Patient Orders screen STAT Samples Learn how to process STAT samples. Tab TitleTextLIS LIS Orders STAT orders received from the LIS are given priority over routine samples STAT Entry STAT Entry Load racks in the STAT entry that require processing before racks in the sample entry queue Create Patient Orders Screen Create Patient Orders Screen On the command bar, select Orders Select Create Patient Orders Enter a Sample ID and then select Enter Select a Specimen Type and other sample information, as needed including Patient Demographics In the Priority area, select STAT Select the test(s) Select Save When complete, select the X in the upper-right corner to close the window and continue. Sample Dilutions Automatic Dilutions – Dilutions that are setup in the software to automatically order a dilution if the original result is greater than the concentration limit System-Performed Dilutions – Dilutions performed by the system using an onboard diluent and ordered in the Create Patient Orders screen Manual Dilutions – Dilutions prepared on the bench and ordered in the Create Patient Orders screen Dilution Profile – Multiple dilutions ordered for a test Note: You must dilute all samples with the correct ADVIA Centaur® XPT system diluent specified for each test. Refer to the assay Instructions for Use (IFU) for more information. System-Performed Dilutions Learn how to order system-performed dilutions. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_OrderingSystemPerformedDilutions_800x600_9/sim_CXPT_OrderingSystemPerformedDilutions_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_OrderingSystemPerformedDilutions_800x600_9/index.htmlPDF File: Manual Dilutions Learn how to order manual dilutions. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_OrderingManualDilutions_800x600_9/sim_CXPT_OrderingManualDilutions_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_OrderingManualDilutions_800x600_9/index.htmlPDF File: Please select Learn more for information on restarting and exam and reviewing images. Test Profiles Tests may be grouped into profiles Profiles can be used to schedule patients when the LIS is not available Test Profiles Learn how to setup and order test profiles. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_SetupOrderProfiles_800x600_9/sim_CXPT_SetupOrderProfiles_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_SetupOrderProfiles_800x600_9/index.htmlPDF File: All test processing begins in the Sample area where the Photometric Sample Probe transfers samples to cuvettes and HM reaction vessels.. View Pending Orders Screen: Displays pending test orders that have not yet started processing Test Results Overview Screen: Displays in progress orders and results Option to monitor tests using the Watchlist feature Dashboard Screen: Posts a quick view of samples and tests by their current state Test Results and Watchlist Learn how to use the Test Results screen and the Watchlist. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_TestResultsOverview_800x600_9/sim_CXPT_TestResultsOverview_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_TestResultsOverview_800x600_9/index.htmlPDF File: Dashboard Learn how to use the Dashboard to monitor samples. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_Dashboard_800x600_9/sim_CXPT_Dashboard_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_Dashboard_800x600_9/index.htmlPDF File: View Pending Orders Learn how to use the View Pending Orders screen. View Pending Orders screen: To access, select Orders from the Command Bar, and then select the View Pending Orders tab Used to view pending QC and patient test orders Options are available to edit or delete orders When complete, select the X in the upper-right corner to close the window and continue. Heterogeneous Immunoassay (HM) methods such as HCG and MMB are incubated, washed, and mixed in the HM module prior to photometric measurement in a cuvette. Reports can be printed for: Today's results Results displayed on the Test Results Overview screen Custom result reports To print a result report, use the Print button on the Test Results Overview screen. Printing Patient Reports Learn how to print patient reports. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_PrintingResults_800x600_9/sim_CXPT_PrintingResults_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_PrintingResults_800x600_9/index.htmlPDF File: The Pump Panel houses the syringes and motors used to measure and deliver fluids through the sample and reagent probes. Transmitting results to the LIS: Patient and control results can be manually retransmitted to the LIS Use the Transmit button in the Test Results Overview screen Transmitting Results to LIS Learn how to transmit results to the LIS. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_TransmittingResults_800x600_9/sim_CXPT_TransmittingResults_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_TransmittingResults_800x600_9/index.htmlPDF File: In this section, you will learn more about the combination of keystrokes that directs the Dimension® system to perform various functions. Exporting results: Control and patient results can be exported to a CD or USB drive Use the Export button in the Test Results Overview screen Export Results Learn how to export results. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_ExportingResults_800x600_9/sim_CXPT_ExportingResults_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_ExportingResults_800x600_9/index.htmlPDF File: Ordering tests by batch mode: Order multiple tests on a group of barcoded samples Use when the LIS is not available or for a group of samples not being processed through the LIS Order a batch in the Create Batch Orders screen Batch Tests Learn how to order batch tests. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90009726/sim_CXPT_OrderingBatches_800x600_9/sim_CXPT_OrderingBatches_800x600_9.swfHTML5 File:/content/generator/Course_90009726/sim_CXPT_OrderingBatches_800x600_9/index.htmlPDF File:
- centauro
- centuar
- centuarxpt
- centaurxpt
- centauroxpt
- centuarxpt
- cenatur
- cenaturxpt
- cen
- cenxpt
- centar
- centarxpt
- centau
- centauer
- centauerxpt
- centure
- centurexpt