AI-Rad Companion - Musculoskeletal Workflow
This PDF provides you an overview of the steps within the Musculoskeletal workflow.
Musculoskeletal Workflow AI-Rad Companion This document introduces the workflow steps with the Musculoskeletal extension in AI-Rad Companion. 1. After activating the Musculoskeletal extension, the 2D segment displays how AI-Rad Companion segmented, identified and labeled the vertebrae. The algorithm also measures the heights in the anterior, middle and posterior position of each vertebra, along with the mean Hounsfield unit of the inner part. For each vertebra, the measured height values are compared with the corresponding values of the neighboring vertebra. T2 20 / 15/ 18 /93 T3 18 / 13 19 101 T4 18 / 18 / 22 /106 T5 20 / 10/ 17 179 T6 14 / 11/ 21 174 17 12 / 13 / 20 / 63 18 13/ 11 / 19 / 111 T9 22 / 20 / 24 /61 T10 23/ 18 / 22 /70 T11 27 / 23 / 27 /67 T12 26 / 20 / 26 /47 Height (mm): Anterior / Mid / Posterior / HU SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Training Material Effective Date: / /2020 | HOODXXX Training Material | Musculoskeletal Workflow – AI-Rad Companion Effective Date: / /2020 | HOODXXX 2. The 3D segment also shows the segmented vertebrae. T8 1/8 PIR T11 12 T10 3. The table below the 3D segment shows the measured values for each vertebra. All comparison results are assigned to a certain category. Results are displayed color- coded. Vertebra Anterior [ mm] Medial [mm] Posterior Average State [mm] [HU] T2 20 15 18 93 Accepted v T3 18 13 19 101 Accepted v T4 18 18 22 106 Accepted v T5 20 10 17 179 Accepted v T6 14 11 21 74 Accepted v T7 12 13 20 63 Accepted T8 13 11 19 111 Accepted v T9 22 20 24 61 Accepted V T10 23 18 22 70 Accepted v T11 27 23 27 67 Accepted v T12 26 20 26 47 Accepted v Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 2 of 5 Training Material | Musculoskeletal Workflow – AI-Rad Companion Effective Date: / /2020 | HOODXXX 4. Decide for all findings to accept or decline them by clicking the button corresponding to your decision: Click Decline if you disagree with the findings. They will be marked as declined in the Results list and will not be sent to the PACS. Accept Decline Leave the state on Accepted if you accept the finding. You can also accept or decline all findings at once by using Accept All or Decline All button at right bottom of result table. Accept All Decline All 5. At any time during the workflow you can suspend the case by clicking on the Suspend button and return to the Worklist. If you then open the patient case again, all your prior decisions on the findings will be shown. If you made all your decisions on the findings, click the Send to PACS button. The patient case will be closed and the data will be sent to the PACS. Suspend Send to PACS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 3 of 5 Training Material | Musculoskeletal Workflow – AI-Rad Companion Effective Date: / /2020 | HOODXXX Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 4 of 5 Training Material | Musculoskeletal Workflow – AI-Rad Companion Effective Date: / /2020 | HOODXXX 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Page 5 of 5
- ai-rad-companion
- ai
- companion
- artificial
- intelligence
- confirmation
- workflow
- software
- overview
- musculoskeletal
- job aid