AI-Rad Companion Software Overview Online Training
This online training introduces you to the software AI-Rad Companion and the workflow steps within the different clinical extensions.
Continue Continue Continue Continue Continue Continue Continue Continue Welcome AI-Rad Companion Software Overview Online Training This online training will introduce you to the software of AI-Rad Companion and cover the following four learning objectives: 1 Perform the basic functionalities of AI-Rad Companion 4 Understand how AI-Rad Companion supports your clinical routine 3 Differentiate between the user roles 2 Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Learn how to access AI-Rad Companion Welcome [Audio file name: audf_ai-rad-companion_sw_overview_olt_welcome.mp3] This online training will introduce you to the software of AI-Rad Companion and cover the following four learning objectives: Learn how to access AI-Rad Companion Differentiate between the user roles Understand how AI-Rad Companion supports your clinical routine Perform the basic functionalities of AI-Rad Companion Hints for Navigating this Online Training Table with 1 columns and 5 rows Before you start, we would like to give you a few tips on how to navigate: Not all pages contain audio. Some pages invite you to read for yourself or watch a video. Some pages show an X button in the upper right corner. Click the X button to return to the overview page and not miss any information provided. Some images show a magnifier icon. Click on the icon to see enlarged view of the image. Another click brings you back to the normal view. Enjoy the course! Hints for Navigating Perform the basic functionalities of AI-Rad Companion Understand how AI-Rad Companion supports your clinical routine Differentiate between the user roles Learn how to access AI-Rad Companion Course Review Congratulations. You have completed the AI-Rad Companion Software Overview Online Training course. Select the objectives listed below to review the material before proceeding to the final assessment. 1 1 1 2 2 2 3 3 3 4 4 4 Course Review [Audio file name: audf_ai-rad-companion_sw_overview_olt_coursereview.mp3] Congratulations. You have completed the AI-Rad Companion Software Overview Online Training course. Select the objectives listed below to review the material before proceeding to the final assessment. Basic functions Open a patient case In order to open a patient case click on a individual case on the Worklist view of the Patient List tab. Use the appropriate view Patient List view: This list provides access to different views organized in lists. Queued view: This list contains cases that are scheduled for processing. Worklist view: This list contains Contains cases that have been successfully processed. Completed view: This list contains cases, that were successfully sent to connected systems, such as PACS or TPS. Failed view: This list contains cases that have not been successfully completed so that no AI results could be processed. All view : This list contains all cases processed and sent to PACS by AI‑Rad Companion. AI-Rad Companion and its benefits AI-Rad Companion is a multi-modality decision support. These are potential extensions of the AI-Rad Companion: Chest CT: automatically measures and highlights relevant anatomies and abnormalities automatically transfers results into the reporting environment supports you in your image interpretation Prostate MR you as radiologist can mark and edit lesions manually manual characterization of lesions and comment function export of segmentations and targets as RT structured format Brain MR you as radiologist can manually monitor the volumetric changes, because the Brain MR extension compares the different volumes to a normative database and automatically generates a deviation map. it automatically generates a result table with volumetric analyses listed Chest X-ray It supports you as radiologist to detect the following: e) Organs RT It automatically performs an organ-based segmentation on CT images. Table with 5 columns and 1 rows Pulmonary lesion Pneumothorax Pleural effusion Atelectasis Consolidation User Roles a) Clinical User Tasks: configures application settings enables clinical extensions interprets the AI- Rad Companion results, that are generated by the clinical extension Confirmation Workflow: The Clinical user reviews the results, that are automatically generated by AI-Rad Companion. b) The IT or Clinical Administrator Tasks: configures application settings configures input and output target nodes supports the clinical user with processing the data Configuration Workflow Access AI-Rad Companion Access AI-Rad Companion via teamplay: Enter the following URL in your Internet browser: https://teamplay.siemens.com The teamplay digital health platform Login page opens. On the teamplay digital health platform Login page, enter your registered e-mail and password. Click the Login button. You are logged on to the teamplay digital health platform. Access AI-Rad Companion: Start the software by clicking on the AI‑Rad Companion icon on the teamplay digital health platform main menu. A message appears that you are transferred to a website. Select OK to start the transfer. AI-Rad Companion starts and the Patient List opens. By default, the Worklist view of the Patient List is displayed. To close AI‑Rad Companion, click the Logoff icon in the Access bar or close the browser window. You are now logged off from AI‑Rad Companion. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start Assessment Automatic measuring Highlight abnormalities Proposing findings Creating diagnosis Which of the following functionalities is not available in AI-Rad Companion? Question 1 of 5 Select the best answer. Multiple Choice Question Incorrect Incorrect Incorrect Incorrect Incorrect Incorrect Correct Correct In the Configuration menu By pressing and holding the scroll wheel of the mouse By double-clicking on the image By pressing and holding the right mouse button How can you pan in the 2D segment? Question 2 of 5 Select the best answer. Multiple Choice Question Incorrect Incorrect Incorrect Incorrect Incorrect Incorrect Correct Correct Queued Completed Failed Worklist In which view can you open a case to review the results? Question 3 of 5 Select the best answer. Multiple Choice Question Incorrect Incorrect Incorrect Incorrect Correct Correct Correct Incorrect Which icon lets you access AI-Rad Companion via the system? Question 4 of 5 Select the applicable image. Pick One Question Incorrect Incorrect Incorrect Incorrect Correct Correct to automatically receive images to automatically send results to PACS to require a confirmation of the results before sending to PACS replace a PACS system Question 5 of 5 The AI-Rad Companion can be configured Select three (3) answers. Multiple Answer Question Incorrect One or more answers are incorrect. Correct Review Review Retry Assessment Results %Results.ScorePercent%% %Results.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the AI-Rad Companion Software Overview Online Training. Completion Introduction to AI-Rad Companion The AI-powered and cloud-based AI-Rad Companion supports you in interpreting medical images through an automatic postprocessing of imaging datasets. The generated reports are easily accessible through the cloud or directly in your PACS system. It is also available for various clinical modalities and body regions. For a short introduction into AI-Rad Companion, please watch the video. AI-Rad Companion in a Nutshell AI-Rad Companion in a Nutshell Access AI-Rad Companion via teamplay Enter the following URL in your Internet browser: https://teamplay.siemens.com The teamplay digital health platform Login page opens. On the teamplay digital health platform Login page, enter your registered e-mail and password. Click the Login button. You are logged on to the teamplay digital health platform. Access AI-Rad Companion via teamplay [Audio file name: audf_ai-rad-companion_sw_overview_olt_access_teamplay.mp3] Before you can access AI-Rad Companion via teamplay you need to ensure, that you are logged in to the teamplay digital health platform. Therefore your system needs to have Internet access and a corresponding Internet browser needs to be installed. Open the teamplay digital health platform by entering the appropriate URL. The Login page opens and you can enter your registered e-mail and password. Click the Login button to be logged on to the teamplay digital health platform. Access AI-Rad Companion by clicking on the AI‑Rad Companion icon on the teamplay digital health platform main menu. A message appears that you are transferred to a website. Select OK to start the transfer. AI-Rad Companion starts and the Patient List opens. By default, the Worklist view is displayed. To close AI‑Rad Companion, click the Logoff icon in the Access bar or close the browser window. Access AI-Rad Companion Access AI-Rad Companion [Audio file name: audf_ai-rad-companion_sw_overview_olt_access.mp3] If you are logged in into to the teamplay digital health platform and the teamplay receiver is configured as a target node on your scanner you can start the software AI-Rad Companion on your system. Therefore start the software by clicking on the AI‑Rad Companion icon on the teamplay digital health platform main menu. A message appears that you are transferred to a website. Select OK to start the transfer. AI-Rad Companion starts and the Patient List opens. By default, the Worklist view of the Patient List is displayed. To close AI‑Rad Companion, click the Logoff icon in the Access bar or close the browser window. General layout and basic functions After starting AI-Rad Companion from the teamplay login page, the Patient List tab opens. For more information, select the orange markers. Select the numbered steps below to learn more about the general layout and basic functions. Patient List views The Patient List views provides access to different views organized in lists. Access bar These icons provide access to AI‑Rad Companion training material, to the instructions for use, configuration settings of all clinical extensions, and to the logoff icon. Search field In this section, you can enter data to search for a case of a specific patient. Patient List The following information is listed for each view e.g.: Name Patient ID Date of Birth Sex Modality Accession No. Scan Date & Time Insertion Date & Time Series Description AI-Rad Extension Information Extension List tab This section displays the list of available clinical extensions. Patient List tab This tab provides access to the Patient List. 1 1 1 2 2 2 3 3 3 General layout and basic functions [Audio file name: audf_ai-rad-companion_sw_overview_olt_general_layout_basic_functions.mp3] After starting AI-Rad Companion from the teamplay login page, the Patient List tab opens. For more information, select the orange markers. Select the numbered steps below to learn more about the general layout and basic functions. For more information, hover over the mouse cursors: By pressing and holding the scroll wheel you can pan the image. By holding the left mouse button and moving the mouse vertically you can change the standard window center settings. By holding the left mouse button and moving the mouse horizontally changes the window width. You can scroll through the 2D images of the selected finding with the scroll wheel of the mouse. By holding the right mouse button down and moving the mouse vertically at the same time you can zoom the image in and out. Navigation in the 2D segment 2D Segment This segment displays the 2D images. 1 1 1 2 2 2 3 3 3 3 Open a dataset In order to open a dataset to review the AI- results navigation click on an individual dataset on the Worklist view of the Patient List tab. The Preview window opens. For more information, select the orange markers. Patient Information Findings Overview Results 2D Segment This segment displays the 2D images. Access bar 1 1 1 2 2 2 3 3 3 2 Table with 2 columns and 2 rows The case is in processing and cannot be opened. The case is processed and ready for confirmation. Paused cases are displayed with the Suspended label. If individual results could not be created, an error indicator is added to the case and displayed in the All, Worklist, or in the Completed view. Patient List views The Patient List views provides access to different views organized in lists. For more information, select the orange markers. You will see the following status symbols in each view: Queued view This list contains cases that are scheduled for processing. Worklist view This list contains cases that have been successfully processed. You can open any case to review the AI results. After reviewing the AI results, you decide to either send the AI results to the PACS or to decline the AI results. Completed view This list contains cases, that were successfully sent to connected systems, such as PACS or TPS. Failed view This list contains cases that have not been successfully completed so that no AI results could be processed. All view This list contains all cases processed and sent to PACS by AI‑Rad Companion. 1 1 1 2 2 2 3 3 3 1 User Roles User Roles AI-Rad Companion provides two different user roles: Clinical User IT or Clinical Administrator Select the numbered steps below to learn more about the two different user roles and their daily routine. 1 1 1 2 2 2 User Roles [Audio file name: audf_ai-rad-companion_sw_overview_olt_user_roles.mp3] The AI- Rad Companion provides two different user roles: the Clinical user and the IT or Clinical Administrator. Select the numbered steps below to learn more about the two different user roles and their daily routine. IT or Clinical Admin 2 1 1 1 2 2 2 The IT or Clinical Admin has a professional education in IT. Tasks: Configuring application settings Configuring input and output target nodes Supporting the Clinical User with processing the data Configuration Workflow Clinical User 1 1 1 1 2 2 2 The Clinical User works locally as a radiologist on a modality site and has an in-depth medical understanding of radiological images. Tasks: Configuring application settings Enabling clinical extensions Interpreting the AI- Rad Companion results, that are generated by the clinical extension Confirmation Workflow: The Clinical User reviews the results, that are automatically generated by AI-Rad Companion. Clinical User - Daily Routine AI-Rad Companion extensions AI-Rad Companion is a multi-modality decision support. AI-Rad Companion extensions are available for different modalities and body regions. The following extensions are currently available: Chest CT Prostate MR Brain MR Chest X-ray Organs RT AI-Rad Companion Extensions [Audio file name: audf_ai-rad-companion_sw_overview_olt_extensions.mp3] AI-Rad Companion is a multi-modality decision support. AI-Rad Companion extensions are available for different modalities and body regions. The following extensions are currently available: Chest CT Prostate MR Brain MR Chest X-ray Organs RT AI-Rad Companion extensions in a nutshell AI-Rad Companion Extensions in a Nutshell AI-Rad Companion Brain MR AI-Rad Companion Brain MR is a post-processing image analysis software that assists clinicians in viewing, analyzing and evaluating MR brain images. Select the numbered steps below to learn more about AI-Rad Companion Brain MR. 1 1 1 2 2 2 3 3 3 4 4 4 Brain MR [Audio file name: audf_ai-rad-companion_sw_overview_olt_extensions_brain_mr.mp3] AI-Rad Companion Brain MR is a post-processing image analysis software that assists clinicians in viewing, analyzing and evaluating MR brain images. Select the numbered steps below to learn more about AI-Rad Companion Brain MR. How can it support you through your clinical routine? automatic segmentation and quantitative analysis of individual brain structures quantitative comparison of each brain structure with normative data from a healthy population presentation of results for reporting that includes all numerical values as well as visualization of these results For more information, select the orange markers. Brain automated segmentation of the different brain areas, including an individual volumetric analysis How can Brain MR support you? 1 1 1 2 2 2 3 3 3 4 4 4 4 Workflow without AI-Rad Companion Brain MR Without AI-Rad Companion you need to manually manipulate imaging datasets. This means you are responsible for manually highlighting suspicious regions and calculating and measuring qualitative or quantitative data. 1 1 1 2 2 2 3 3 3 4 4 4 1 Brain MR in a nutshell 1 1 1 2 2 2 3 3 3 4 4 4 2 AI-Rad Companion can be seamlessly integrated into the image evaluation workflow. It can help you to do your daily work more easily. The image dataset is transferred via teamplay receiver to AI-Rad Companion for post-processing and analysis. Workflow with AI-Rad Companion Brain MR 1 1 1 2 2 2 3 3 3 4 4 4 3 AI-Rad Companion Chest CT The Chest CT extension is an imaging decision support aid for Chest CT interpretation (lung, heart, aorta and vertebra). Select the numbered steps below to learn more about AI-Rad Companion Chest CT. 1 1 1 2 2 2 3 3 3 4 4 4 Chest CT [Audio file name: audf_ai-rad-companion_sw_overview_olt_extensions-chest_CT.mp3] The Chest CT extension is an imaging decision support aid for chest CT interpretation (lung, heart, aorta and vertebra). Select the numbered steps below to learn more about AI-Rad Companion Chest CT. How can Chest CT support you? How can it support you through your clinical routine? automatically measures and highlights relevant anatomies and abnormalities assessment of pulmonary densities automatically transfers results into the reporting environment supports you in your image interpretation For more information, select the orange markers. Lung Segmentation and measurements of the complete lungs and lung lobes and parenchyma segmentation Lung lesion detection and measurement Assessment of pulmonary densities Heart Heart segmentation and calcium detection Aorta Aorta segmentation and diameter measurements Vertebra Vertebra body segmentation and density measurements 1 1 1 2 2 2 3 3 3 4 4 4 4 AI-Rad Companion can be seamlessly integrated into the image evaluation workflow. It can help you to do your daily work more easily. The image dataset is transferred via teamplay receiver to AI-Rad Companion for post-processing and analysis. Workflow with AI-Rad Companion Chest CT 1 1 1 2 2 2 3 3 3 4 4 4 3 Chest CT in a nutshell 1 1 1 2 2 2 3 3 3 4 4 4 2 Workflow without AI-Rad Companion Chest CT Without AI-Rad Companion you need to manually manipulate imaging datasets. This means you are responsible for manually highlighting suspicious regions and calculating and measuring qualitative or quantitative data. 1 1 1 2 2 2 3 3 3 4 4 4 1 AI-Rad Companion Chest X-ray AI-Rad Companion Chest X-ray is a diagnostic aid for radiology professionals in the assessment of posterior-anterior chest radiographs for the presence of prespecified radiographic findings. Select the numbered steps below to learn more about AI-Rad Companion Chest X-ray. 1 1 1 2 2 2 3 3 3 4 4 4 Chest X-ray [Audio file name: audf_ai-rad-companion_sw_overview_olt_extensions_chest-x-ray.mp3] AI-Rad Companion Chest X-ray is a diagnostic aid for radiology professionals in the assessment of posterior-anterior chest radiographs for the presence of prespecified radiographic findings. Select the numbered steps below to learn more about AI-Rad Companion Chest X-ray. How can it support you through your clinical routine? It supports you as radiologist to detect the following: Pulmonary lesion Pneumothorax Consolidation Atelectasis Pleural effusion For more information, select the orange markers. How can Chest X-ray support you? Chest automatically characterizes pulmonary lesions, pleural effusion, pneumothorax, consolidation and atelectasis automatically highlights pneumothorax and pulmonary lesions 1 1 1 2 2 2 3 3 3 4 4 4 4 AI-Rad Companion can be seamlessly integrated into the image evaluation workflow. It can help you to do your daily work more easily. The image dataset is transferred via teamplay receiver to AI-Rad Companion for post-processing and analysis. Workflow with AI-Rad Companion Chest X-ray 1 1 1 2 2 2 3 3 3 4 4 4 3 Chest X-ray in a nutshell 1 1 1 2 2 2 3 3 3 4 4 4 2 Workflow without AI-Rad Companion Chest X-ray Without AI-Rad Companion you need to manually manipulate imaging datasets. This means you are responsible for manually highlighting suspicious regions and calculating and measuring qualitative or quantitative data. 1 1 1 2 2 2 3 3 3 4 4 4 1 AI-Rad Companion Organs RT AI-Rad Companion Organs RT performs organ-based segmentation on CT images without any user interaction. Select the numbered steps below to learn more about AI-Rad Companion Organs RT. 1 1 1 2 2 2 3 3 3 4 4 4 Organs RT [Audio file name: audf_ai-rad-companion_sw_overview_olt_extensions_organs_rt.mp3] AI-Rad Companion Organs RT performs organ-based segmentation on CT images without any user interaction. Select the numbered steps below to learn more about AI-Rad Companion Organs RT. How can it support you through your clinical routine? Organs at risk contouring. Contours are created as Radiotherapy Structure Set (RTSS) objects. For more information which organs are automatically segmented, select the orange markers. Breast and Lung Prostate Abdomen How can Organs RT support you? 1 1 1 2 2 2 3 3 3 4 4 4 4 Head and Neck With AI-Rad Companion the contouring of organs at risk is automatically done with consistent results. Workflow with AI-Rad Companion Organs RT 1 1 1 2 2 2 3 3 3 4 4 4 3 Organs RT in a nutshell 1 1 1 2 2 2 3 3 3 4 4 4 2 Workflow without AI-Rad Companion Organs RT Without AI-Rad Companion you have to contour the organs at risk manually. This is tedious and time consuming. 1 1 1 2 2 2 3 3 3 4 4 4 1 AI-Rad Companion Prostate MR AI-Rad Companion Prostate MR is a post-processing image analysis software that assists clinicians in viewing, manipulating, analyzing, and evaluating MR prostate images for Ultrasound (US) guided MR-US fusion biopsy planning. Select the numbered steps below to learn more about AI-Rad Companion Prostate MR. 1 1 1 2 2 2 3 3 3 4 4 4 Prostate MR [Audio file name: audf_ai-rad-companion_sw_overview_olt_extensions_prostate_mr.mp3] AI-Rad Companion Prostate MR is a post-processing image analysis software that assists clinicians in viewing, manipulating, analyzing, and evaluating MR prostate images for Ultrasound (US) guided MR-US fusion biopsy planning. Select the numbered steps below to learn more about AI-Rad Companion Prostate MR. How can it support you through your clinical routine? automatic segmentation and quantitative analysis of the prostate gland manual annotation of relevant findings presentation and export of results for further processing and report export of segmentations and targets as RT structured format (RTSS) that can be imported in ultrasound systems and in DICOM format for archiving in PACS For more information, select the orange markers. How can Prostate MR support you? Prostate automated segmentation of the prostate gland automated volume estimation and PSA-density calculation 1 1 1 2 2 2 3 3 3 4 4 4 4 AI-Rad Companion Prostate MR is intended to improve the MR-US fusion prostate biopsy workflow. Therefore, AI-Rad Companion Prostate MR provides the urologist with annotated MR image data of the prostate gland. The data is provided in RTSS (Radiotherapy Structure Set) format for importing into ultrasound systems for biopsy planning, and as burnt-in contours in DICOM MR images. In that way, AI-Rad Companion Prostate MR aids the radiologist and urologist in prostate biopsy planning Workflow with AI-Rad Companion Prostate MR 1 1 1 2 2 2 3 3 3 4 4 4 3 Prostate MR in a nutshell 1 1 1 2 2 2 3 3 3 4 4 4 2 Workflow without AI-Rad Companion Prostate MR With current tools, it is challenging for the radiologist to show the urologist the location of the lesions to be biopsied. The radiologist can mark the lesion on the abstract sketch of the biopsy on the PIRADS report. Based on this information, the urologist has to draw the lesion on the MR images within their fusion biopsy planning software. In this process, information and accuracy are often lost. If the radiologist chooses to draw the lesions for the urologist, they have two options. These options are either to go to the biopsy machine or to a separate workstation provided by the biopsy software to draw the lesions. 1 1 1 2 2 2 3 3 3 4 4 4 1 IT or Clinical Administrator Configuring General settings In the General settings window, you can specify how the cases will be displayed in the Patient List. On the Access bar, click the Settings icon to open the Settings window. Select Save to save the latest settings. For more information, select the orange markers. Retention Period Enter a retention period to specify how long cases will be displayed in the lists. You can enter any number from 1 to 7. Categories To customize the shown columns of the Patient List views, select or clear the check boxes in the Categories section. Visualization To customize the shown Patient Information of cases, select or clear the check boxes in the Visualization section. Configuring general settings [Audio file name: audf_ai-rad-companion_sw_overview_olt_configuring_general.mp3] In the General settings window, you can specify how the cases will be displayed in the Patient List. On the Access bar, click the Settings icon to open the Settings window. Select Save to save the latest settings. For more information, select the orange markers. Notifier AI‑Rad Companion is supplied with the Notifier, which is intended to send result notifications with status-reporting information about AI-result calculation processes. The Notifier is only intended to be used with the workflow to review the processed results within AI-Rad Companion. It is possible to download the Notifier directly from AI-Rad Companion > General settings. Notifier [Audio file name: audf_ai-rad-companion_sw_overview_olt_configuring_notifier.mp3] AI‑Rad Companion is supplied with the Notifier, which is intended to send result notifications with status-reporting information about AI-result calculation processes. Notifier is only intended to be used with the workflow to review the processed results within AI-Rad Companion. It is possible to download the Notifier directly from AI-Rad Companion under the General settings. Configuring AI-Rad Companion Extensions Under the Settings window you can also configure application-specific settings for each extension, such as: define whether the results require manual confirmation or can be sent directly to PACS. activate or deactivate the generation of DICOM Structured Report (DICOM SR) results configure the data selection settings, etc. For more information, please click the tabs to get directly transferred to the configuration workflows. Chest CT MR Prostate MR Brain Organs RT Chest X-ray Configuring AI-Rad Companion Extensions [Audio file name: audf_ai-rad-companion_sw_overview_olt_extensions_configuring.mp3] Under the Settings window you can also configure for each extension application-specific settings, such as: define whether the results require manual confirmation or can be sent directly to PACS. activate or deactivate the generation of DICOM Structured Report (DICOM SR) results configure the data selection settings, etc. For more information, please click the tabs to get directly transferred to the configuration workflows. HOOD05162003141588 | Effective Date: 15 JAN 2021 1.1 Welcome 1.2 Hints for Navigating 2 Introduction to AI-Rad Companion 2.1 AI-Rad Companion in a Nutshell 2.2 Access AI-Rad Companion via teamplay 2.3 Access AI-Rad Companion 2.4 General layout and basic functions 3 User Roles 3.1 User Roles 4 Clinical User - Daily Routine 4.1 AI-Rad Companion Extensions 4.2 AI-Rad Companion Extensions in a Nutshell 4.4 Chest CT 4.3 Brain MR 4.7 Prostate MR 4.5 Chest X-ray 4.6 Organs RT 5 IT or Clinical Administrator 5.1 Configuring general settings 5.2 Notifier 5.3 Configuring AI-Rad Companion Extensions 1.3 Course Review 1.4 Disclaimer 1.5 Assessment
- ai-rad-companion
- ai
- companion
- artificial
- intelligence
- confirmation
- workflow
- software
- overview