Annotating and Saving Waveforms to USB
Annotating and Saving Waveforms to USB step by step
Annotating and Saving Waveforms to USB Interventional Radiography: Cardiac Please refer to manual for complete system capability at www.siemenslearningcenter.com Sensis waveforms can include annotations, then copied to MS Word, and saved to USB drive for presentations. Patient Applications Edit View Acquire Input Tools Options He HC X1 Review Real Time ECG-6 Zero AO LV FA ART test, test Calculate Snapshot View 25 mm/'s Hemodynam ... Print Waveform Workflow Support 2:21:36 PM LHC X1 TT 10 Current condition 4. Post Post Proces ... -AVR 10 40 RV 40 B 36 12 Sample Annotation 32 28 24 20 16 12 8 O STOF Notes Graphics |Layout Filter All Time Label Comment Vital Signs 2:20:04 PM Rec on Vital Sign Alarms 2:20:05 PM Rec off General Events 2:20:06 PM Rec on Mark Events 2:39:18 PM Rec off 2:52:49 PM Snapshot X-ray Data X-ray Image Events Results Storage: 730:35 10:37:14 AM - Rec off 10:38:24 AM 1. Use the (GRAPHICS TAB) located in lower right corner for Annotations. See Figure (2) 2. For TEXT Annotation: Click (ABC) Icon, then move the mouse into the middle of the screen, Click the Screen where the annotation will appear and enter Text. See Figure (2) 3. For a BOX Annotation: Click the Icon next to the (ABC) Icon, then move the mouse into the screen, Click and Drag the mouse to create a box in the area of interest. See Figure (2) 4. For ARROW Annotations: Click the (ARROW) Icon, then move the mouse into the screen, Click and drag the mouse to draw an arrow. See Figure (2) SIEMENS siemens.com/healthineers Healthineers Job Aid | Annotating and Saving Waveforms to USB Effective Date: 09/06/2016 | Quality HOOD0516200926002 5. Make a Copy of the Waveform with Annotation by hitting the F13 key on the keyboard. 6. Open MS Word using the (Flying Windows) key>Programs>Microsoft Office>MS-Word 2007. See Figure (3) 7. Paste the (Screen Copy) into the open word document. 8. Insert a "Virus Free" USB drive in the Sensis DMC computer. (Left PC Tower) 9. Save the Word document to the inserted USB drive. 10. Before removing the USB drive from the DMC computer, Click the eject USB Icon located at the bottom right area of the screen. See figure (4) *NOTE: Only USB drives known to be virus free should be used. Figure (2) Notes Graphics Layout ABC Figure (3) Notes Graphics Layout AXIOM Sensis Label Comment Em AXIOM Sensis XP Information System AOA ABC Rec off Service AOD Rec off Jam Workflow Guides AO Rac off FF Programs Accessories Microsoft Office Microsoft Office Word 2007 Shut Down ... Startup Storage: 3285:12 Registration on AXIOM Artis Succeeded 12:36:52 Figure (4) Siemens Healthineers Services Page 2 of 3 Job Aid | Annotating and Saving Waveforms to USB Effective Date: 09/06/2016 | Quality HOOD0516200926002 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- Angiography/Interventional Imaging
- Axiom Artis