Aortic Valve Guide-AVG
Aortic Value Guide - AVG Interventional Radiography: Cardiac Please refer to manual for complete system capability: www.siemenslearningcenter.com 1. Cardiac DynaCT is acquired and loaded into InSpace Tab 2. Select Aortic Valve Guide icon if not automatically started. 3. Aortic root is segmented out automatically. SIEMENS siemens.com/healthineers Healthineers Job Aid | Aortic Valve Guide - AVG Effective Date: 09/06/2016 | Quality HOOD0516200893802 4. Check results, modify display, and correct positions of markers. a. Correct position of any marker by left clicking, drag and drop, in any MPR or VRT view b. Modifying Display can be achieved using the selections below Aortic ValveGuide Aortic ValveGuide 1 Adjust C-Arm to volume i 2. Use iPilot for Overlay i 1. Adjust C-Arm to volume 2. Use iPilot for Overlay Show Show Corcour Corcour Perpendicularty Circle Perpendicularty Circle Coronary Ostia Indicators Coronary Ostia Indicators Commissure Lines Commissure Lines w Measurements Measurements Cercerine Close Close Heb VB20 VB21 3td AVVO SHADESURF SHUIDESURF 2345 6/22/1900- LACIRAD LACRAD CRANICAUD CRANUCAUD Setzentum LecSo ConbHl 628/2008 09:46.07 AX A A B 100 W 2329 B 100 W 2829 80 C 1523 C.1029 5. Perform iPilot Dynamic functionality. Close Heb Siemens Healthineers Services Page 2 of 4 Job Aid | Aortic Valve Guide - AVG Effective Date: 09/06/2016 | Quality HOOD0516200893802 Additional Information Movie Recording - ability to record movies in AVI format from currently displayed images. Movie X 00 STOP Close Help Stop movie recording Pause movie recording Movie recording is active Replay stored movie At this step, it will ask for a file name H:CDR Offline // Site Data // InSpace // iPilot Dynamic Display Items: Centerline - display of centerline of segmented aortic root Perpendicularity Circle with coronary cusp points L - Left Coronary Cusp Point R - Right Coronary Cusp Point N - Non Coronary Cusp Point *** Can drag and drop L, R, N to correct in any MPR or VRT Coronary Ostia Markers LCO - Blue RCO - Green Commissure Lines - show path along the valve leaflets that connect the cusp points together *** Can drag and drop to correct in any MPR or VRT MPR Segments align such that: Upper Left - luminal view of aorta, orthogonal to centerline Upper Right - view along centerline, axial projection Lower Left - other view along centerline Siemens Healthineers Services Page 3 of 4 Job Aid | Aortic Valve Guide - AVG Effective Date: 09/06/2016 | Quality HOOD0516200893802 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 4 of 4
- Angiography/Interventional Imaging
- Axiom Artis