Aptio® Automation (Inpeco) Daily Maintenance and Replacing Consumables Online Training

List the daily maintenance tasks and describe how to replace consumables. This clinical laboratory training qualifies for continuing education units (CEU).

Note: This training is designed for systems which include "AP2" or "APT" and the letter "C" in the serial number. If your system serial number includes "APT" but does not include the letter "C", please select the Aptio Automation (Siemens) training area.

Welcome to the Aptio® Automation Daily Maintenance and Replacing Consumables Online Training course. Performing daily maintenance and documenting completed procedures will: Minimize down time Provide optimal performance Provide records for inspection Replace consumables as needed to maintain laboratory workflow and efficiency. Aptio is a registered trademark of Siemens Healthcare Diagnostics Inc., or its affiliates.   Describe how to replace consumables  List the daily maintenance tasks Upon successful completion of this course you will be able to: Congratulations. You have completed the Aptio Automation Daily Maintenance and Replacing Consumables Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. List the daily maintenance procedures Decapper - Empty cap waste Desealer - Empty foil seal waste Storage and Retrieval - Empty sample tube waste Aliquoter - Empty tip waste   Describe how to replace consumables    Aliquoter - Load Tips Bring Off-line. Remove the tips container lid Remove the bottom lid from under the tip box Insert tips box in the tips container Pull the paper flaps and remove Lift the handle and remove the box Replace the tips container lid Use software to confirm tips box is filled. Bring On-line Aliquoter - Load secondary sample tubes Bring Off-line. Open the caps container lid Fill container to MAX fill line and replace the lid. Bring On-line Use software to confirm tube box is filled. Bring On-line Aliquoter - Replace the label roll Bring Off-line. Open the door under the labeling area Lift up the tube label area Press the white button then the black release lever to open the print head Remove the black plastic take up spool clip Pull the label roll latch spring and move away from the roll Remove the old roll and load new one Feed the new roll and secure with the black clip Check label alignment and adjust, if needed Close print head and lower tube label area Advance the label tape and print a test label Check label quality Close all doors and bring On-line Sealer – Replace the foil coil Bring Off-line Home the sealing head, wait for head to cool down Remove empty coil and replace Thread the strip under the Locker, Puller and Cutter Reset the reel count to 16000 or 19000 depending on coil Sealer cuts 10 pieces of foil. Remove from system Close safety shield and bring On-line Recapper – Load secondary sample tube caps Bring Off-line Open cap container door and load caps Close container and bring On-line   Daily maintenance is performed on the following modules: Decapper Desealer Storage and Retrieval Aliquoter Note: Refer to the Aptio Automation Manual when performing these procedures. Follow your laboratory's operating procedures for handling biohazardous materials. Document completion of these procedures in the daily maintenance table.      Empty the waste bin  Perform this procedure daily Supplies needed: Biohazard bag   Emptying Waste Learn how to empty the waste on the Decapper Module. Checklist TitleChecklist TypeChecklist ContentBring module Off-lineHTML In the Overview screen, select Decapper. Select Status. Ensure that the Decapper Module robot has stopped all movement before proceeding to the next step. Select Off-line -  Do not Flush.    Remove and replace the biohazard bagHTML   Select the play arrow to begin. Empty the waste bin Perform this procedure daily Supplies needed: Biohazard bag Emptying the Waste Learn how to empty the waste on the Desealer Module. Checklist TitleChecklist TypeChecklist ContentBring module Off-lineHTML In the Overview screen, select the Desealer button. Select Status. Ensure the Desealer Module robot has stopped all movements before proceeding to the next step. Select Off-line - Do Not Flush. Remove and replace the biohazard bagHTML   Select the play arrow to begin. Empty the waste bin Perform this procedure daily Supplies needed: Biohazard bag     Emptying Waste Learn how to empty the waste on the Storage and Retrieval Module. Checklist TitleChecklist TypeChecklist ContentEmpty and replace waste containerHTML    Select the play arrow to begin.  Consumables are replaced as needed on the follow modules: Aliquoter Recapper Sealer Note: Refer to the Aptio Automation Operations Manual when performing these procedures. Follow your laboratory's operating procedures for handling biohazardous materials. Document replacement of consumables in the As Needed Maintenance Table.      Replace the sealer coil Supplies needed: Sealing aluminum coil Replacing the Sealer Coil (Foil Reel) Learn how to replace sealer coil on the Sealer Module. Checklist TitleChecklist TypeChecklist ContentBring module Off-lineHTML   In the Overview screen, select the Sealer button.  Select Status > Off-line > Do Not Flush. Ensure the Sealer Head is in the Home position and not over the Cutter. Home the sealing headHTML In the system software, select Diagnostics – Sealing Head > Home. Check the Heater temperature. Wait until this value, is 55°C/131°F or less before continuing this procedure. It will take approximately 30 minutes for the value to reach 55°C/131°F. Select Diagnostics - Sealer Loader > Locker > Up.   Replace the sealer coilHTML   Select the play arrow to begin. Reset the reel counterHTML Select Status > Reel Count to reset the reel counter to 16,000 or 19,000 seals, depending on the number of seals present in the new coil. Bring the module On-lineHTML Select Status > On-line Empty the tips waste Perform this procedure daily Supplies needed: Biohazard bag     Emptying the Tips Waste Learn how to empty the tips waste on the Aliquoter Module. Checklist TitleChecklist TypeChecklist ContentBring module Off-lineHTML   In the Overview screen, select the Aliquoter button. Ensure the Aliquoter Module has stopped all movements before proceeding to the next step. Select Status > Off-line > Do Not Flush. Open the waste tip doorHTML Open the Aliquoter waste tip container door using the handle to pull the door outward.  Note: This image is for illustration purposes only. Follow your laboratory's practices and procedures and use a biohazard bag when operating the system. Remove the tips waste containerHTML Remove the tips waste container from the module. Note: This image is for illustration purposes only. Follow your laboratory's practices and procedures and use a biohazard bag when operating the system. Remove the tip bagHTML Remove the diverter clips to fix the tip bag at the waste container. Remove the biohazard bag and discard the bag and its contents. Note: This image is for illustration purposes only. Follow your laboratory's practices and procedures and use a biohazard bag when operating the system.   Install a new bagHTML Install a new biohazard bag in the waste container. The biohazard bag must fit snugly in the waste container and be fully opened to allow the tips to drop freely into the container. Re-insert the clips to fix the tip bag at the waste container. Note: This image is for illustration purposes only. Follow your laboratory's practices and procedures and use a biohazard bag when operating the system. Replace waste containerHTML   Ensure the tips waste container has been out of the system for more than 10 seconds. In the Status screen select Waste Count and confirm pop-up. Slide the waste container back into the waste area, pushing firmly against the rear wall to ensure that the container is in the correct position. Note: This image is for illustration purposes only. Follow your laboratory's practices and procedures and use a biohazard bag when operating the system. Close the doorHTML Close the door. Bring the module On-lineHTML Ensure that the module is not in an error condition. Select On-line. Supplies needed: Tips Secondary sample tubes Label roll Loading Tips and Secondary Sample Tubes Learn how to load tips and secondary sample tubes in the Aliquoter Module. Checklist TitleChecklist TypeChecklist ContentBring the module Off-lineHTML   In the Overview screen, select the Aliquoter button. Select Status > Off-line.  Remove tips container lidHTML   Remove the tips container lid.  Remove the bottom lid from the tips boxHTML   Remove the bottom lid from under the tips box.  Insert box into tips containerHTML   Keeping a hand under the tips box to avoid tips dropping, insert the tips box in the tips container.  Remove paper stripsHTML   Pull the paper flaps on the top of the tips box away from the box. Pull one end of the flap until both flaps are removed from the box. Remove tip boxHTML    Hold the handles and slowly lift the tips box out of the tips container.  Replace tips container lidHTML  Replace the tips container lid. Reset tip box inventoryHTML   Select Diagnostics- Tips. Select Box Filled. Select Tip Box. Select Tip Box Filled. Fill sample tubes containerHTML   Remove the lid from the secondary sample tubes container and fill it with secondary sample tubes to the MAX fill line. Do not overfill the container.  Replace the tube container lidHTML   Replace the lid. Ensure that it is properly placed and that the lid presence sensors are engaged.  Reset the inventory and bring On-lineHTML In the system software, select Diagnostics – Tube Hopper & Pinchroller.  Select Tube Box > Tube Box Filled. Bring the module On-line. Replacing the Label Roll Learn how to replace the label roll on the Aliquoter Module. Checklist TitleChecklist TypeChecklist ContentBring module Off-lineHTML   In the Overview screen, select Aliquoter. Select Status> Off-line > Do Not Flush. Replace the label rollHTML   Select the play arrow to begin. Install a tubeHTML To print a test label, first place a secondary tube in the labeling area. The tube is placed between the rollers with the open end closest to the operator and the bottom on the secondary tubes waste side. Print a test labelHTML   Select Diagnostics – Labelling & BCR > Print Label. Confirm Labeling Test. Verify the test labelHTML   Verify that the label is correctly positioned and that the printed data (barcode, human readable, and four printed rows) is legible.    Close the printer wingHTML   Close the printer wing (door). Bring module On-lineHTML  Select Status > On-line. Consumable replacement on Recapper Module as needed maintenance: Replace caps   Supplies needed: Secondary sample tube caps Learn to reload caps Learn how to load caps in the Recapper Module. Checklist TitleChecklist TypeChecklist ContentBring Off-line and open cap container doorHTML In the Overview screen, select Recapper > Status > Off-line > Do Not Flush. Open the Recapper Module caps container door located in the module lower part by pulling it outwards. Load capsHTML Load caps in the cap container. Press flap and close doorHTML Close the door by pressing the flap at the left side and pushing the door. Bring module On-lineHTML Ensure that the module is not in an error condition. Bring the module On-line.   Message area in the Overview screen displays warnings that maintenance is scheduled to be done. The statuses are: Scheduled - timeout has not been reached Due - timeout has expired Overdue - timeout has expired for at least double the configured time To view details: Select the notification message Select the maintenance activity from the message list Once performed, confirm its completion

  • aption
  • automaton
  • track
  • clean
  • supplies