Argus 2D Ventricular Function

Argus 2D Ventricular Function

Argus 2D Ventricular Function 1. Open Patient Browser a. Select All Short Axis Series Patient Browser Patient Applications ransfer Edit View Filter Evaluation Sort Options Help Tissue E o × 10] cine_LAX_2ch R/com/ / / / / / Local Database . MR_Cardiac_Analys Heart_Av_Infai- 12] cine_SAX Scheduler MR Cardiac_Analys [13] cine_SAX R/// /// / R/com/ 7/11 / CARDIAC 14] cine_SAX R/com/ 11/1 1 ZE 35_MALE_ANA 15] cine_SAX R// / / / / / ₹/com/ / / / / / WORKFLOW_ADV. 16] cine_SAX Rjcom/ 7/77 7 Neuro_ASL & cePe 17] cine_SAX Ricom/ 1111 7 MR_Spectro_Head_ 18] cine_SAX R/// / / / / Ricom/ 17/7 / LAH_CHD_SPEC [20] cine SAX krspec271004 [21] cine_SAX R/// /// / R/com/ // / / / CM CUD DEDICO 112al cina CAY Patient name MR Cardiac_Analy: Date of birth 1/1/1980>atient ID Germany_MAC Study description Heart Av Infarct Tissue Quant Study date 10/19/2011 Modality MR 1 2 3 4 5 _91.7 91.7 L91.7 L91.7 L91.7 L91.7 1917 O L91.7 Querying database Current Filter: Off 2. Select Applications > Argus 0Patient Browser Patient Applications Transfer Edit V Report Open Report Tools Mosaic TH 3D Argus BreVis SIEMENS siemens.com/healthineers Healthineers Job Aid | Argus 2D Ventricular Function Effective Date: 05/28/2018 | Quality HOOD05162002886681 3. Select Argus Task Card 4. Select Ventricular Function icon TOTIUS ONT LOD MR_Cardiac_Analys 4D a. CINE images populate as follows i. Vertical Rows > Slice location ii. Horizontal Colum’s > Cardiac Phases Patient Applications Argus Analysis Argus Tools System Options Help MR_Cardiac_Analysis HLP HK BB Kardiologie MR_Cardiac_Analysis HLP HK BB Kardiologie Germany_MAC 1/1/1980, F, 31Y Germany_MAC Avanto M1/1 /1980, F, 31Y Avanto MR_Cardiac_Analys Exam HFS 46:53 PM 4:47:17 PM 4D Viewing ARH ARH MF 1.00 MF 1.00 10cm 10cm JE136 TR 33.6 TE 1.2 RETRO/DIS2D BW 930.0 M/RETRO DIS2D Filming ET tf12d1_12/70 FOV 293*360 Foy 293*360 TT 0.0 SP L21.7 Potentially off-label use in the US 863 Potentially off-label use in the US cine_SAX 360 cine_SAX 1 2 4 5 6 7 8 View 1 Fast 3D 0.0 Slow cine SAM line SAX e_SAX -SAX L101.7 E_SAX O Layout 111.8 SAX SAX Image Sorting Argus Series Number Triggered 3 Siemens Healthineers Services Page 2 of 7 Job Aid | Argus 2D Ventricular Function Effective Date: 05/28/2018 | Quality HOOD05162002886681 5. Select All Images a. Select Icon upper left corner i. Selects All Images 1 2 3 4 5 6 7 8 1 TT 0.0 ITT 0.0 ITT 0.0 TT 0.0 |TT 0.0 TT 0.0 TT 0.0 TT 0.0 SP L21.7 SP L31.7 SPL41.7 SP L51.7 SP L61.7 SP 171.7 SPL81.7 SPL101.7 cine SAX ine_SAX cine_SAX cine SAX cine SAX cine SAX cine SAX cine SAX 2 TT 0.0 10.0 |TT 00 TT 0.0 SPL111.8 SP L121.8 SP _131.8 SPL91.7 cine SAX cine SAX cine_SAX cine SAX 6. Magnify & Review Images View Slow Fast a. Select Zoom /Pan icon i. Upper Left Segment > Depress left mouse button > Double page cursor > magnify image Layout b. Select Zoom/Pan icon again > turns off icon mage Sorting Series Number Triggered 7. Scroll through images a. Left to right scroll bar – determine true End Diastole (ED) and End Systole (ES) 8. Select ES, Base, and Apex a. Horizontal scroll right to find blue End Systolic marker i. Drag End Systolic marker > true End Systolic time column (e.g., image with 9 ES 11 smallest blood pool volume) Siemens Healthineers Services Page 3 of 7 Job Aid | Argus 2D Ventricular Function Effective Date: 05/28/2018 | Quality HOOD05162002886681 9. Pink Base Marker > Drag down to “End Systole – true base ES slice level”(e.g., exclude images above true base level) TT 290 SP F 25,2 trufi_ cinesshort-axis TT 293 SP F35,2 trufi_cine_short-axis 10. Vertical > Scroll down to find “End Systole - True Apex Slice Level” and Drag Pink Apex Marker up (e.g., exclude images be- low true apex level) TT 128.9 SP F18.1 CINE_segmented_ IT 130.9 SP F28.1 CINE cemented 11. Horizontal > Scroll left to find ‘Yellow End Diastolic marker’ 4 ED a. Drag marker to “True End Systolic Time Column” (e.g., image with largest blood pool volume usually the first phase, could be nearer last phase) b. “End Diastolic Phase” > drag Upper Pink Base Marker 4 down to “True Base Slice Level” > drag Lower Pink Base IT 00 Marker up to “True Apex Level” (e.g., exclude images P H21.9 CINE_segmented_ above true base level and below true apex level) 5 LT 00 SP H11.9 CINE_segmented. Siemens Healthineers Services Page 4 of 7 Job Aid | Argus 2D Ventricular Function Effective Date: 05/28/2018 | Quality HOOD05162002886681 12. Draw Borders a. Column 1 > Left Mouse and select Mid-Ventricular Slice Level at “End Diastole” i. Image displayed upper left screen in the active box 13. Drawing tools a. Drawing > select Circle b. Active Region > select EndoCardium icon i. Draw a Red Circle around Endocardial border of blood pool > depress left mouse button and drag cursor from upper left edge to lower right edge rawing Drawing Editing Active Region RETRO EndoCardium icon 3P1-3 Base 14 34 FOY 280 Sag-Tra(35.B) -Corres of retro Ela heartbeats MAGNEVIST 0.0s 14. Select Auto Adjust icon 15. Select Propagate ED icon ED a. Select keyboard up and down arrows > check all ED borders. 16. Select Nudge icon a. Dotted line appears > use left mouse to adjust borders SIM /31/1974, M, 20Y MR D TUDY 1 17/2011 44:56 PM IMA 1 / 25 HR 2.75 R 45.6 E 1.4 A 04.64 9 VV/ 960.0 B M/RETRO/NORM/DIS2D/FM1 3 TP H39 01-3;SP1-3 SL 8.0/2.0 fi2d1_14/53 FoV 265 340 IT 0.0 ED 114 208 P H31.9 Tra>Con-38.2)>Sag(30.6) R 1151 +/- 18: 5 heartbeats INE_segmented_SAX b3 714 342 DE Siemens Healthineers Services Page 5 of 7 Job Aid | Argus 2D Ventricular Function Effective Date: 05/28/2018 | Quality HOOD05162002886681 17. Select Propagate ED to ES icon ED ES a. Adjust ES Borders if necessary with Nudge icon 18. Review Results Drawing Result a. Select Results Tab b. Select Volume Volume ... i. If prompted - enter Patient’s Heart Rate, Height, and Weight Thickening ii. Toggle dog-ear “Corners on Volume Table” to review measured and normalized results Smooth Contours Sectors 19. Select Save As – Saves selected results 20. Create a Report (e.g., Optional) a. Select Reporting icon > Report Options dialog box opens i. Select Create new report Report Options Finding : Create new report View current report Append to current report Cancel b. Select Reporting icon i. Select View current report  Scroll to bottom of report > select Close 21. Close All remaining windows Siemens Healthineers Services Page 6 of 7 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2017