ARTIS icono VE20 syngo iFlow Job Aid
This PDF job aid will demonstrate the workflow for performing syngo iFlow on your ARTIS icono VE20.
SIEMENS Healthineers ARTIS icono VE20 syngo iFlow Effective date: 05.29.2020 | HOOD05162003097073 Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare, 2020 Unrestricted © Siemens Healthcare GmbH, 2020 syngo iFlow SIEMENS Healthineers Table of Contents Introduction 3 syngo iFlow workflow steps 4 CCCY R 120 2 Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare GmbH, 2020 syngo iFlow SIEMENS Healthineers Introduction syngo iFlow provides a single composite image that shows the history of contrast medium flow through the vessels in time in a colored image. syngo iFlow is used to distinguish different time phases and their observed contrast bolus flow in one single image. It can be used for all interventional radiology applications where contrast is injected and only small movement artifacts can be observed. The syngo iFlow function displays a computer generated composite RGB 105 image obtained from a range of images with contrast agent. Hint: The software assumes that the image was generated with a positive contrast agent e.g. iodine. If negative contrast agent was used, e.g. CO2, the image is treated as if positive contrast agent was used. Introduction 3 Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare GmbH, 2020 syngo iFlow SIEMENS Healthineers Workflow steps Acquire the image: • syngo iFlow can be used for all interventional radiology applications where contrast is injected. • syngo iFlow is not available for DYNAVISION or 3D scenes and for pulse reduced fluoroscopy scenes. Generate the syngo iFlow image: omyPan Moas E Segment Menu ? BX • Select the Menu icon in the segment header. • Select the Image tab. Image Windowing E Edge Zoom/Pan Flo FROM Measurement = • Select the syngo iFlow icon. Annotation CLEARS. Acquisition Averaging Storing OPAC ifw Adjusting the syngo iFlow bolus You can adjust the frame range and therefore the colors used for displaying the syngo iFlow image. • Start time: Time of first frame (mask frame). Star 0.20 Duration 1:27 • Duration: Time duration of the flow. O 1.47s • Scene length: Length of the scene used for syngo iFlow. Adjustment can be made via the one of the following methods: • Use the slider below the color legend in the workflow header. • Click on the – or + buttons or enter them via the keyboard. • Click into the image with the middle mouse button and move the mouse with the button presses. Workflow 4 steps Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare GmbH, 2020 syngo iFlow SIEMENS Healthineers Workflow steps 0 27 Reposition of the color spectrum legend • The time scale of the color spectrum legend indicates the range of the frames used for computing the 3.86 syngo iFlow image. The color spectrum can be positioned: 45 • Vertical: on the right of the image. • Horizontal: on the bottom or top of the image. 11.05 • Right click on the image and chose: Color Legend > Horizontal Bottom or Horizontal Top or Vertical. 7.45 0.27 14.64 3.86 11.05 14.64 Time Vs Contrast Intensity Graph Displaying the time-versus-contrast intensity graph contrast concentration • Right-click on the image and choose Time-versus-Contrast Intensity Curve. • Move the cursor over the image. • The time versus contrast intensity curve (in purple color) is updated dynamically corresponding to the pixel where the cursor is positioned. time [sec) Workflow 5 steps Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare GmbH, 2020 syngo iFlow SIEMENS Healthineers Workflow steps Adding syngo iFlow markers: Resetting syngo iFlow parameters: You can add markers to the image to display the corresponding • Click the Home icon in the workflow header. time-versus-contrast intensity curves. • The syngo iFlow image is regenerated based upon the start • Click the point to mark the image. default values. 5.33s • A marker is position and displayed. The corresponding time-versus-contrast intensity curve is displayed statically in the corresponding color. Deleting syngo iFlow markers: • Right click on the image and select Delete All Markers. Adding total contrast syngo iFlow ROI objects: ROI shapes: syngo iFlow ROIs provide the possibility to determine the extent of Ref • perfusion of a region of an organ compared to a reference region, Circular iFlow ROI O for example before and after treatment. • • Select the ROI icon in the workflow header. Rectangular iFlow ROI • Draw up to four ROIs. • Polygonal iFlow ROI 53 Workflow 6 steps Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare GmbH, 2020 syngo iFlow SIEMENS Healthineers Workflow steps Time-versus-ROI intensity graph: Time Vs ROI Contrast Intensity Graph • For each ROI, the time-versus-ROI contrast intensity is shown in the Time Vs ROI Contrast Intensity Graph contrast concentration window. • The graph contains one curve for each ROI object. • The x-axis shows time. • The y-axis shows the sum of pixel intensities (= total contrast; representative of contrast concentration within the ROI. Time Vs ROI Contrast Intensity Graph Results X Time-versus-ROI contrast intensity results: • The results are shown in the Time Vs ROI Contrast Intensity Graph Results window. Documentation of syngo iFlow results: IFlowCurveDataExport X Exporting syngo iFlow curve data: You can document the syngo iFlow color image as follows: Path • You can export the iFlow curve data in CSV COR_OFFLINE Store as a Store Monitor image. Format format. • Filename CSV Right click in the image and select iFlow Curve • Export the current image. • Copy the image to the clipboard. Save Cancel Date Export in the menu. • Workflow 7 steps Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare GmbH, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH, 2020 8 Effective Date: 05.29.2020| HOOD05162003097073 Unrestricted © Siemens Healthcare GmbH, 2020
- artis
- artsi
- icono
- artisicono
- angio
- angiography
- interventional
- floor
- biplane
- UI
- user-interface
- user
- interface
- software
- iconoSW
- ARTIS
- icono
- iFlow
- VE20