Artis One Essentials
Artis One Essentials Workbook
SIEMENS Artis zee Artis One Essentials Workbook SIEMENS Healthineers . www.usa.siemens.com/education I. Contact Information Summary Welcome to Siemens Healthineers Visit www.usa.siemens.com/clinicaleducation for more information regarding the current Siemens Siemens Healthineers is dedicated to helping you get the Clinical Training and Continuing Education portfolio. most out of your investment throughout the entire product life cycle and beyond. Our goal is to enable you Discover. Try. Buy. on webShop to take technology further, profitability higher, and patient care to the next level. Find the information, resources, and Do you want to “Discover. Try. Buy.” options, accessories, tools you need to get the most out of your recent and clinical education to make the most of your investment and stay up-to-date. imaging equipment? Discover images, case studies, Visit www.usa.siemens.com/Welcome2Healthcare. and video demonstrations with the latest clinical applications. Try advanced applications utilizing Clinical Training and Continuing Education free software trials. Buy applications, coils, clinical education, and accessories, conveniently at any time. Customer Care Center - Clinical Application Support: Visit www.usa.siemens.com/webShop today! Call 1-800-888-7436 Siemens Training Centers Troubleshooting assistance • Immediate assistance for software Siemens Clinical Education • applications and workflow issues Training Center – TDC2 110 Mac Alyson Court Please provide the Functional Location Number when • Cary, NC 27511 calling for assistance. Clinical Education Offerings: Call 1-888-221-8010 (follow the prompts) Classroom Training (Offerings, Registration • & Scheduling) Educational Symposia • On-site Training • Printed Self-studies • Virtual Education (Offerings & Registration) • Workshops & Fellowships • 2 II. Contents I. Contact Information Summary .....................................................................................................................................2 II. Contents ............................................................................................................................................................................3 III Agenda ................................................................................................................................................................................4 Day One .................................................................................................................................................................................. 5 Day Two ................................................................................................................................................................................ 37 Day Three ............................................................................................................................................................................. 76 Day Four ............................................................................................................................................................................. 111 3 III Agenda Day One 08:30 – 09:00 Welcome & Safety 09:00 – 10:00 System Overview 10:00 – 10:30 Break 10:30 – 11:30 System Overview 11:30 – 12:00 Hands-on Time 12:00 – 13:00 Lunch Break 13:00 – 14:00 Patient Managment 14:00 - 14:30 Examination at Control Console 14:30 – 15:00 Examination at TSC 15:00 – 15:30 Break 15:30 – 16:30 Hands-on Excercise Day Two 08:30 – 09:00 Q/A 09:00 – 09:30 Roadmaps 09:30 – 10:00 Roadmaps/Overlay Ref 10:00 – 10:30 Break 10:30 – 11:00 Exam Sets/OGP 11:00 – 11:30 CLEARStent 11:30 – 12:00 CLEARStent LIVE 12:00 - 13:00 Lunch Break 13:00 – 14:30 Perivision/Stepping 14:00 – 15:00 HeartSweep/3D Set up 15:30 – 16:30 Hands-on Excercise Day Three 08:30 – 09:00 Q/A 09:00 – 10:00 Post Processing 10:00 – 10:30 Break 10:30 – 11:30 Quant 11:30 – 12:00 Archiving 12:00 – 13:00 Lunch Break 13:00 – 13:30 Archiving/Networking 13:00 – 15:00 3D Post Processing 15:30 – 16:30 Hands-on Excercise Day Four 08:30 – 09:00 Q/A 09:00 – 10:00 Hands-on Excercise 10:00 – 10:30 Break 10:30 – 11:00 Review/Final Discussion 11:00 – 12:00 Hands-on Time 12:00 Depart 4 Workshop Workbook | Artis One Essentials Day One Artis One: System Overview Notes SIEMENS Healthineers Artis One: System Overview Siemens Medical Solutions USA , Inc ., 2018 System Overview SIEMENS Healthineers (1) Floor stand with C-arm, X-ray tube assembly and FD (2) Patient table (3) Display ceiling suspension (DCS) with 30" Display, optionally with additional LC display (4) Footswitch for releasing radiation (2) (5) Control console for controlling the stand, patient table, and imaging system (4) (6) Handswitch @ Siemens Medical Solutions USA, Inc ., 2018 Page 2 SIEMENS. System movements Healthineers ... Operating Area: Up to 210cm Patient coverage (depending on table position, movement etc.) Siemens Medical Solutions USA, Inc ., 2018 Page 3 5 Workshop Workbook | Artis One Essentials Notes FD SIEMENS Healthineers New Midsize Detector: 'as 30' . Amorphous silicon detector Artis on Imaging Size: 29 cm x 26 cm . Laser cross-hair not available . No tape (system movement) available Zoom Nominal Pixels Zoom 0 39 cm 1560 × 1420 Zoom 1 32 cm 1216 × 1216 Zoom 2 25 cm 960 x 960 Zoom 3 20 cm 776 × 776 Zoom 4 16 cm 608 × 608 Zoom 5 11 cm 424 × 424 Siemens Medical Solutions USA, Inc ., 2018 Page 4 Components in Imaging Chain - X-Ray Tube SIEMENS .... Healthineers MEGALIX Cat Plus 125/40/90-125GW .2-Focus tube · Small Focus: 0.4 (Flat Emitter) . Large Focus: 0.8 (Filament) 8º Anode Angle Oil/Water cooled Siemens Medical Solutions USA, Inc ., 2018 Page 5 Components in Imaging Chain - Monitors SIEMENS . Healthineers' ... Artis one Exam Room Monitor One midsize Large Display (30") Highbright monitor DSC3012-DC Resolution: 2560 x 1600 Typical Luminance: 400 cd/m2 LUT: DICOM Up to 4 internal sources: Live, Assist, Info Area, 3D Up to 4 external sources possible Optional second display: Size: 19" - 24"(Siemens delivers 21") Siemens Medical Solutions USA, Inc ., 2018 Page 6 6 Workshop Workbook | Artis One Essentials Notes Table SIEMENS.: Healthineers (2) One table top Fixed mounted on the (1) Tabletop transverse movement (manual) (2) Tabletop longitudinal movement (manual) (3) Table lift (motorized) (4) Table rotation (manual) @ Siemens Medical Solutions USA, Inc ., 2018 Page 7 Table Rotation SIEMENS . Healthineers .. No TCM controlled table rotation Table rotation only possible via pedal, mounted on base of table column Every 3º table locks (Artis zee: every 5º) Note: Releasing the table breaks with foot switch still possible Siemens Medical Solutions USA, Inc ., 2018 Page 8 Table SIEMENS. Healthineers ... Max. Weight Two different stickers available: max Max. Patient weight ... kg Accessory and CPR load not included Max. Table load Accessory .... kg load included But no CPR load! Always check the label on the table to verify the weight limit. siemens Medical Solutions USA, Inc ., 2018 Page 9 7 Workshop Workbook | Artis One Essentials Notes SIEMENS .... Table Healthineers' ... Accessory rails Accessory rails cannot be moved, they are fixed mounted on table Foot rail Caution Accessories are too heavy for the accessory rails and the table. Risk of personal injury by falling parts. The weight limits for the accessories (all accessories, e.g. Side rail injector, radiation protection devices) attached to the accessory rails of the table are as follows: Maximum 100 kg in total . Maximum 60 kg at the side rails each Maximum 40 kg at the foot rail siemens Medical Solutions USA, Inc ., 2018 Page 10 Table SIEMENS .... Healthineers ... Accessory rails Additionally there are holder with rails for head-end of table tops available Not for use with head-end lower radiation protection shield Do not exceed the max. accessory load of 40kg @ Siemens Medical Solutions USA, Inc ., 2018 Page 1y Table SIEMENS. Healthineers Max. Weight under Cardiopulmonary resuscitation (CPR) The Artis one systems are designed for cardiopulmonary resuscitation (CPR = Cardio-Pulmonary Resuscitation) with a pressure compression of up to 600 N (60 kg). The maximum patient weight must not be exceeded. (+ Page 57 Maximum patient weight) 1 Make sure that there is enough free space for performing CPR. 2 Remove any objects, such as chairs, from the examination area. CPR position To achieve the greatest possible stability for a cardiac massage (CPR = cardiopulmonary resuscitation), the tabletop must be moved so that it is directly above its supporting table column. Siemens Medical Solutions USA, Inc ., 2018 Page 12 8 Workshop Workbook | Artis One Essentials Notes Table SIEMENS Healthinpers. .. Lock Tabletop Movement New with Artis one available is the Lock Tabletop Movement function @ Siemens Medic Page 13 Safety SIEMENS .: Healthineers Collision detection ** Depending on the Configuration available @ siemens Medical solutions USA , Inc . , 2018 Page 14 Safety SIEMENS Healthineers .. Collision detection This contact safety switch on stand column is available depending on room configuration In extremely small rooms maybe the stand column distance to the wall is < 500mm - additional contact safety switch required. Smallest zone is 310mm Siemens Medical Solutions USA, Inc ., 2018 Page 15 9 Workshop Workbook | Artis One Essentials Notes SIEMENS Safety Healthineers' Power failure - rescuing the patient The floor stand cannot be moved manually in normal operation If a power failure occurs, the floor stand can be unlocked and swiveled by pushing against the C-arm The button to unlock the stand is located on the rear side of the floor stand @ Siemens Medical Solutions USA, Inc ., 2018 Page 16 Safety SIEMENS .: Healthineers Power failure - Rescuing the patient 1) Push the button until locked 2) Move floor stand manually 3) Push button again (this results in 1) & 3) releasing it actually) 4) Perform a stand reset on EHC 2) 1 Simultaneously press the buttons Store position and Set zero stop STOP as well as the emergency STOP button on the stand/C-arm control module (5CM). The unit computer is restarted and should be ready for operation after a short time. 2 Do not forget to pull the emergency STOP button again . @ Siemens Medical Solutions USA, Inc ., 2018 Page 17 Brake Test SIEMENS. Healthinpers ... Brake test - Required check The first time a user is demanded to perform the brake test is configurable (in combination with next normal patient i registration): 1 h to 648 h (27 days), default 600 h (25 days) Please ask Siemens Service for configuration. With expiration of this time interval, another timer of 120 h (5 days) is started Warning Inspection of the brake function A brake malfunction may lead to uncontrolled movements, thus injury to the patient, to the clinical staff, or damage to property. Perform the brake test in a fixed time interval. (The interval can be configured.) @ Siemens Medical Solutions USA, Inc ., 2018 Page 18 10 Workshop Workbook | Artis One Essentials Notes Brake test - "How to" SIEMENS ..... Healthineers' ... 1 Select the Parking position. 2 Press down the stand joystick and deflect it forward until the Parking position has been reached. The system drives to the Parking position. The message "Stand Test: Activate stand movement # s" is displayed. (# is a configurable time between 1 and 10 s) 3 Press down the stand joystick and deflect it forward again. The brake test is started and the message "Stand Test: running" is displayed. The system performs the brake test for each axle (6 times). @ Siemens Medical Solutions USA, Inc ., 2018 PaBe Control Room SIEMENS Healthineers ... Control Room Keyboard Mouse Monitor Siemens Medio System On SIEMENS .; Healthineers Press the power-on pushbutton on the Imaging system box for more than 0.5 s and then release the button. SIEMENS @ Siemens Medical Solutions USA, Inc ., 2018 Page 21 11 Workshop Workbook | Artis One Essentials Notes System Off SIEMENS .... Healthineers ... Shutdown System . Select „Options" > „,End Session" > „,Shut Down System End Session Log Off Shutdown System Bostort Systom Restart Application Cancel Hab Never use the main power off switch to shut down the system @ Siemens Medical Solutions USA, Inc ., 2018 Page 22 Stand Reset SIEMENS . Healthineers . Reset Stand . Press the emergency stop button while the override buttons are activated at stand control module STOP Siemens Medical Solutions USA, Inc ., 2018 Page 23 Artis One Handswitch SIEMENS Healthineers The handswitch has two operating elements: Acquisition button · With the acquisition button, you can release acquisition series and single acquisitions as preselected in the acquisition program. Multifunctional button . In a program with manual variable frame rate, it is used to switch from one phase to the next. . In a PERIVISION or DR STEPPING acquisition program, it is used Siemens TO release stepping in a filling run. Page 24 12 Workshop Workbook | Artis One Essentials Notes Activate Fluoro on Handswitch SIEMENS Healthineers Footswitch / Handswitch - Activate Fluoro on Handswitch Function can be activated via Examination - Acquisition - Activate Fluoro on Handswitch Only activate if Footswitch is broken and no Fluoro can be released If once activated Fluoro not possible anymore from Footswitch anymore but only Acquisition! Function can only be reset after a complete shutdown of the system Activists Foto on Handywitch Do you really want to estivale flesso un liendswitch? Yea @ Siemens Medical Solutions USA, Inc ., 2018 Page 25 Foot Switch SIEMENS .. Healthineers . The footswitch pedals can be configured by Pymbor Standard function Siemens Service. Fluorescopy (fto) amative acquidition" (2) Switch Roadmap on/off (1) (4) Parket Roadmap (3) Tabletop brake AUX Ausiliacy switchconfigu lalée by Siemens Service. e.a. moons light oadolf AUX 2 Auxillary switch 2º @ Siemens Medical Solutions USA, Inc ., 2018 configurable by Siemens Service Alternative Acquisition SIEMENS Healthineers . In order to have a fast access to special acquisition program, an Alternative Acquisition can be assigned to a footswitch pedal. An alternative acquisition program can be used. The alternative acquisition program may be, e.g.: a low dose acquisition for CARD. The dose shall be typically between fluoroscopy and normal acquisition, e.g. 80 ... 150 nGy a low dose DSA acquisition a single shot DR acquisition a CLEARstent or CLEARstent Live acquisition any acquisition program that is not a special mode @ siemens Medical Solutions USA, Inc ., 2018 Page 27 13 Workshop Workbook | Artis One Essentials Notes Restrictions with Alternative Acquisition SIEMENS .. ; Healthineers ... Restrictions No injector synchronization Overrides not available Measuring field of the regular acquisition program always in use Forecast values only visible with mouse over icon Siemens Medical Solutions USA, Inc ., 2018 Page 28 Controls SIEMENS . Healthineers ... 144 -I - Siemens Medical Solutions USA, Inc ., 2018 Page 29 Table Control Module - TCM SIEMENS. Healthineers ... Perform table lift Set isocenter LED lights or flashes while function active. (+ Page 155 Patient coordinates) Lock tabletop movement LED lights while function active. Lock lateral tabletop movement LED lights while function active. Siemens Medical Solutions USA, Inc ., 2018 14 Workshop Workbook | Artis One Essentials Notes Stand Control Module - SCM SIEMENS Healthineers* ** Select Anatomical Positions LED is lit while function active. Select angulations or linear movements The lit LED indicates which function is active. Select System Positions LED is lit while function active. Store position LED is lit while function active. Set zero stop LED is lit while function active. Select orientation ( Page 111 Orientation key) +0+ Select direct positions I, II, III LED is lit while function active. @ Siemens Medical Solutions USA, Inc ., 2018 Page 31 System movements / positions SIEMENS Healthineers ... System movements with joystick . To toggle between rotational and linear movement of the joystick Default = rotational movement of the C-arm Time out when no action = 2 sec. default Moving the C-arm horizontally C / Make sure that linear movement is selected. Press the stand joystick down and deflect it in the required -D direction. The C-arm follows the movement. C-arm rotation (crania Ucaiadal angulations) Make sure that angulation movement is selected. Fress one or both side buttons on the C-arm joystick, press down the joystick and deflect it to the left or right. The C-arm performs the corresponding cranicaud angulation. Siemens Medical Solutions USA, Inc ., 2018 Page 32 System Positions vs. Anatomical Positions SIEMENS Healthineers ... Anatomical Positions System Positions Are intended to provide an Are intended to bring the system/lab identical view and image into a standard position at the impression. Only the beginning of a procedure. viewing direction, zoom, filter settings are restored. All system axles are moved exactly to the stored position (including the The stand and table position stand) is kept if possible to avoid 2x interruptions of the For manual axles (table rotation) the procedure. -0+ user is requested to move manually into the stored position. The same behavior is used for automap and direct positions! Siemens Medical Solutions USA, Inc ., 2018 15 Workshop Workbook | Artis One Essentials Notes System Positions SIEMENS Healthineers System Positions .All mechanical system axles were restored in the way they are saved, except collimators and filter. Positions on page 1 of the list are factory positions and cannot be changed by the user. .Positions on page 2&3 can be saved, named and rearranged by the user. Siemens Page 34 System Positions SIEMENS . Healthineers . Patient Transfer Head Side Left Side Parking Position Peri Position Right Side, Table Rotated Operating Area: OR Position Up to 210cm Patient coverage (depending on table position, movement etc.) Siemens Medical Solutions Inc ., 2018 Page 35 System Positions Onscreen menu Artis one SIEMENS Healthineers ... Systum Positions Patient Transfer Preview Head Sie Left Side Pape DR Position 1/3 Pari Position Paring Faction Automap Siemens Medical Solutions USA, Inc ., 2018 Page 36 16 Workshop Workbook | Artis One Essentials Notes What is Automap Stand? SIEMENS. Healthineers Automap Stand . C-arm drives via selection in System Positions to the angulation and longitudinal position of the currently displayed reference image System Positions Patient Transfer Preview Hand Side Right Side, Table Rutaind PAGE OR Pastinn 173 Port Foutinn Parking Position Auttmap Siemens Medical Solutions USA, Inc ., 2018 Page 37 Anatomical Positions Onscreen menu Artis one SIEMENS Healthineers ... Anatomical Positions Preview Page 1/5) @ Siemens Medical Solutions USA , Inc ., 2018 Page 38 SIEMENS Anatomical positions with Isocenter Healthinpers ... Anatomical Positions - With Isocenter An Anatomical position can not remember the examined organ but only the geometry of the projection To make the system aware to remember also the table position (rotation, table longitudinal or transversal movement) - press Isocenter key first Then store or recall Anatomical position Nice, when position during an examination must be changed Siemens Medical Solutions USA, Inc ., 2018 Page 39 Center 17 Workshop Workbook | Artis One Essentials Notes System movements / positions SIEMENS ..... Healthineers ... Anatomical Positions - With Isocenter Without Isocenter - system doesn't follow the table With Isocenter - the system is aware of the actual table positon Page Siemens Medical Solutions USA, Inc ., 2018 Anatomical Positions: SIEMENS .... Healthineers Workflow storing position with Isocenter Anatomical Positions - Workflow storing position with Isocenter 1.Position the C-arm and the table (angulation and isocenter)for the first desired projection 2.Press the Isocenter key 3.Store the position as „,Position 1" 4. Position the C-arm and the table (angulation and isocenter) for the second desired projection 5.Store the position as „Position 2“ Positions are stored relative to the marked isocenter Siemens Medical Solutions USA, Inc ., 2018 Page enter Anatomical Positions: SIEMENS. Healthineers Workflow storing position with Isocenter 1. Select „Position 1" and move to that position. 2.Position the patient in the isocenter manually by positioning the tabletop or by moving the C-arm CO 3.Press the isocenter key. 4. Select ,, Position 2" and move to that position. The system restores ,, Position 2" relative to the marked isocenter Siemens Medical Solutions USA, Inc ., 2018 Page 18 Workshop Workbook | Artis One Essentials Notes System movements / positions SIEMENS Healthineers Organize Stored Positions Both Anatomical and System positions can be organized via Console in Control room Organizing stored positions The Organize Stored Positions dialog lets you configure the available programmed positions, i.e. System Positions and Anatomical Positions. You can arrange the positions to your needs and to your examination practice. You can also apply write protection to selected positions. Opening the position editor On the system console in the control room: 1 Select Options > Configuration ... in the main menu. 2 Double-click the Organize Stored Positions icon. @ Siemens Medical Solutions USA, Inc ., 2018 Page 43 System movements / positions SIEMENS Healthineers Organize Stored Positions The Organize Stored Positions dialog shows a list of the stored positions and a preview of the selected position. Positions can be marked by a symbol: Factory position (cannot be edited) E Protected position (cannot be deleted or overwritten) Preview . Here renaming, write protection, changing the order is possible Please Note: If the Organize Stored Positions is open no storing of positions from examination room is possible - first store postions, rename afterwards ( ,, postprocessing") Page System movements / positions SIEMENS. Healthineers ... Direct Positions I / II / III . Press and hold the required position key. The system moves to the corresponding position. Workflow has changed in Artis one In Artis zee you activate one of the desired Direct position and deflect the joystick In Artis one no interaction with the joystick is required anymore.(Possible but not required) Please Note: Storing the position is still performed in the same way: Press Store button Siemens Medical Softtions Select Direct position the system position should be stored 19 Workshop Workbook | Artis One Essentials Notes Collimator Control Module - CCM SIEMENS Healthineers ... Upper joystick controls the wedge filter. Lower joystick controls rectangular diaphragm Reset collimator leaves and filter diaphragms 1 # Collimator/FD rotation (Multispace) # # Q + Change image input format/zoom stage @ Siemens Medical Solutions USA, Inc ., 2018 Page 46 Storing Filters for Cardiac SIEMENS Healthineers Functionality only avalible if you have selected a Card program! . Move the Filter to the desired position Select the button "Store" . Press the joystick button @ Siemens Medical Solutions USA, Inc ., 2018 Page 47 Storing Filters for Cardiac SIEMENS Healthineers ... Functionality only avalible if you have selected a Card program! 1 Diagonal pre-selection of Semitransparent Filter blades after selecting a Card program. For easier placement of the filterblades, the right filter is always rotated in the upper right corner @ Siemens Medical Solutions USA, Inc ., 2018 Page 48 20 Workshop Workbook | Artis One Essentials Notes SIEMENS . TSC - Onscreen menu access Healthineers ... There are three buttons available on the TSC console to open Onscreen menus: Examination related Postprocessing Onscreen menus related Onscreen menus ** Display Layout selection @ Siemens Medical Solutions USA, Inc ., 2018 Pape 49 er Access to Onscreen menus SIEMENS Healthineers ... A new approach to our Artis system 2 Deflect the mouse joystick, left/right for navigating between pages. =up/down for navigating between items. To select an item of the Onscreen menu: 3 Press the left mouse joystick button. To close the Onscreen menu: 4 Press the menu key again. Siemens Medical Solutions USA, Inc ., 2018 Page 50 Access to Onscreen menus SIEMENS. Healthineers . A new approach to our Artis system Navigate Select Close Press the right mouse joystick button. (Within a submenu, only the submenu is closed.) i When X-ray is released, or after a configurable time-out (default: 10 s), the Onscreen menu will be automatically closed. @ Siemens Medical Solutions USA, Inc ., 2018 Page 51 21 Workshop Workbook | Artis One Essentials Notes Imaging system table-side control (TSC) SIEMENS Healthineers' Key Description Block radiation Block movements @ Siemens Medical Solutions USA, Inc ., 2018 page Imaging system table-side control (TSC) SIEMENS ..... Healthineers . The following keys can be configured optionally: -- Lm setles Haserlotion n Select the previous fluorsecopy picoam Duplay more twelve Distation the --- Setereno Plage deechtey Strak sa next referones image Siemens Medical Solutions USA, Inc ., 2018 Artis one Exam Room Monitor SIEMENS.; Healthineers ... SOR Rostmas D. Series Description siemens Medical Solutions USA, Inc ., 2018 Page 54 22 Workshop Workbook | Artis One Essentials Notes Layout gallery Onscreen menu SIEMENS. Healthineers' ... Display Layouts Layout 1 Layout test Now Layout Layout 2 Layout 3 syngo 3D Layouts Siemens Medical Solutions USA, Inc ., 2018 Page 55 Examination Onscreen menu SIEMENS . Healthineers ... DO Exam Acq Program Frame Rate Flora Program Roadmap O Overlay Reference Image O , Series Description ... Default> Exam Set . Dilatation Timer O Siemens Medical Solutions USA, Inc ., 2018 page 36 Postprocessing Onscreen menu: SIEMENS. Healthineers Native Review Zoom by Factor 2 -- Adjust Windowing Annotation Text ... Annotation Circle Distance Measurements Hide Annotations Delete Annotations Siemens Medical Solutions USA, Inc ., 2018 Page 57 23 Workshop Workbook | Artis One Essentials Notes CARE Functions - All Included SIEMENS Healthineers' .. CARE Function CAREmatic Automatic Exposure Control CAREvision Extended Pulsed Fluoroscopy CAREfilter Automatic Copper Filter Selection CAREprofile Collimation without Radiation CAREposition Positioning without Radiation CAREwatch Display of Dose Area Product CAREmonitor Display of Skin Entrance Dose CAREguard Dose Alert CAREreport Detailed Dose Information Siemens Medical Solutions USA , Inc . , 2018 page 58 CLEAR Functions - Standard SIEMENS Healthineers' ... CLEAR Function CLEARcontrol Automated histogram analysis in universal measurement field aka: "UDOM" CLEARview Dose adaptive algorithm to reduce noise aka: "EE" CLEARvessel Crisp visualization of vessel edges without increasing noise aka: "EVE" CLEARmotion Compensation of motion artifacts and automatic detection of fine structures aka: "k-auto" @ Siemens Medical Solutions USA, Inc ., 2018 Page 59 Grid Removal Symbol SIEMENS . Healthineers'? Remove Grid for Air Gap Technique (Peds under 20Kg) When anti scatter grid is removed symbol in examination taskcard changes from O Gym2 2.90 Artis on to 13.10.11-16:32:00-DST Examination O 1/1/1900 mGy 0 UGym2 0.00 Page 60 24 Workshop Workbook | Artis One Essentials Notes SIEMENS Healthineers Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. is Medical Solutions USA, Inc ., 20 25 Workshop Workbook | Artis One Essentials Patient Management Notes SIEMENS Healthineers ... Artis one Patient Management 9 Siemens Medical Solutions USA, Inc ., 2018 Keyboard SIEMENS .... Healthineers (1) (2) (3) (4) (1) Function keys (2) Alphanumeric keys (vary for different languages) (3) Cursor control keys (4) Numeric/syngo keypad @ Siemens Medical Solutions USA, Inc ., 2018 page? Keypad (Layout) SIEMENS .. Healthineers Key Function |Function Window center (WC) - (Num + ) (Brightness -) Scrol seriesiscene forward INum 51 Window center (WC) + (Num /) (Brightness +) scroll nage back (Nom 1) Window Width (ww) - (Num ") [Contrast -) semil image forward (Num 2) Mark image [Num 3; Window Width (ww). +(Num -} [Contrast +) Undity scene narne (Nam Jo preparation) Autowindowing (Num 9) Cal up Patient Registration (Num 0) Scroll study back (Num 7) Cal up Patient Browser (Nuns;) M Scroll sturdy forward (Num a) Copy to Film Shout (Niam Entei) Scruli serius/sters back (Num 4) Siemens Medical Page 3 26 Workshop Workbook | Artis One Essentials Notes Patient Registration I SIEMENS.: Healthineers . Enter „,Patient Registration“ manually Register an ,, Emergency Patient" Siemens Medical Solutions USA, Inc ., 2018 Page 4 Patient Registration II SIEMENS. Healthineers ... Option DICOM Get worklist . Select patient entry in the Scheduler Option Sensis . Register patient at Sensis . Registration is automatically transferred to Artis @ Siemens Medical Solutions USA, Inc ., 2018 Page 5 Patient Registration Menu SIEMENS. Healthineers ... PROCEDURE a nome Accession No Firstname procachets? Etrit Orcep Mil tary Rank Pubert D Date of Binn ISTITUTION Wwight: [o] Perkering ptvachon 2 Pertsenino Desicion info HOSPITAL moremng physician Dr.BRF Requesting physician Admitting diagnosis wwwd Adrive on l @ siemens Medical Solutions USA, Inc ., 2018 Page 6 27 Workshop Workbook | Artis One Essentials Notes Height/Weight Conversion in Patient Registration SIEMENS. Healthineers --- Siemens Medical Solutions USA, Inc ., 2018 age 7 Hints on Patient Registration SIEMENS Healthineers Registration of a new patient with „Exam“ Resets the Fluoro Timer and the Dose Area Product to zero . Resets all non stored modifications in the exam sets to their last stored state Resets the ,, Set Iso" button to the default table height display For cardiac exams or for CAREmonitor calculations, „,Height and Weight" should be registered Date format and height and weight format can be adjusted in ,, Regional Settings" @ Siemens Medical Solutions USA, Inc ., 2018 Page 8 Patient Registration & Close Patient SIEMENS Healthineers .. "Patient's name on Exam room monitor" The patient's name appears on the Exam room monitor after pressing the > button in Patient Registration "Close Patient" Feature When an examination is over and this button is pressed, the monitors turn black. @ Siemens Medical Solutions USA, Inc ., 2018 Page 9 28 Workshop Workbook | Artis One Essentials Notes Patient Browser SIEMENS . Healthineers ... Paberg Browser Pudert Trumiler Edt Yhow Flet Zott Ccions Help Tool Bar Tree View Local Diocese Scheduler Scheduler 114 07.13-001106-5 Abbott »GAF Anderson, Susan Andonon, Chasing ....... . ARTIB BOLV Mark Swin Patent Names Frot' 123 1006 1/1/1800 01 07 13-00:52:00-8TD 10/111900 04 07 18:09 611/16/1858 Abbot, - 3AF 2803255H0 64.2004 Content Andersont Subset 653-44811 Andertan, Christine 07/03 Area ARTS BCLY 123 Artis MP. 3000 1234 1/1/1800 Comrparición BA_GTA 329002 311420 @ Siemens Medical Solutions USA, Inc ., 2018 Page 10 DICOM Information Model SIEMENS . Healthineers CS_5_Abd_Livertransplantation ocal Database DSA - John Doe A-Aorta Scheduler DSA -Perivision A.Aorta Overview CD_READ DSA Aorta, Aneurysm A-Fluoro Balloon DSA Upper Extemities, Stenose B-2sec-Dyna McNamara C ., Charles PC Truncus Study date 10/2/02 Modality XA 15 SM Patient 1 or ,n‘ Study 1 or ,n' Series 1 or ,n stance @ Siemens Medical Solutions USA, Inc ., 2018 Page 11 How to Review a Study SIEMENS Healthineers ... Double-click on the „,Study" to be reviewed . All scenes are loaded automatically . The directory overview is displayed Double-click on the ,, Scene" to be reviewed . All scenes are loaded automatically . The selected scene is replayed in full screen display Drag&Drop the scene into the . All scenes are loaded automatically . The selected scene is replayed in full screen display Siemens Medical Solutions USA, Inc ., 2018 Page 12 29 Workshop Workbook | Artis One Essentials Notes How to Reopen an Existing Study SIEMENS Healthineers Click on the ,, Patient Folder" < Study> to be reopened for further acquisitions in the browser Click on . Patient demographic data will be filled in already Select , and if required . Click on Siemens Medical Solutions USA, Inc ., 2018 Page 13 Browser - Correcting Data SIEMENS Healthineers ... Correct Modiner's Name moduser First name Tie Refernina ptysioim Other Patients nerrets) Admission ID Detur Panort Dpi) Ethnic group Miltary rank Accession No Date of Birth 1/1/1500 Mais Other Not set in Series duepson CARD_SUB Weicht CZ I Metne Serive cute 7/27/2011 Addioss Number Adatioralirto Coreiment OK Cancer Siemens Medical Solutions USA, Inc ., 2018 Page 14 Merging Patient Data SIEMENS Healthineers ... . Complete Case . Register new patient . Patient Browser-Local Database · Highlight both patients (Use Control Key on Patient Level) Protection must be removed. . View ---- Open Sub-tree · At Series level, highlight Scene(s) to be moved to correct patient (Use Control or Shift Key for multiple scenes . Drag or Cut/Paste Scene(s) to Study Level of correct patient Images will be renamed accordingly 98 @ Siemens Medical Solutions USA, Inc ., 2018 Page 15 30 Workshop Workbook | Artis One Essentials Notes Browser Configurations SIEMENS Healthineers ' Set Circlexc 4 Read Partiabteil Tool Poo Heading Pool Sece Heading Settings Siemens Medical Solutions USA, Inc ., 2018 Page 16 Browser - Stamp View SIEMENS Healthineers REF SM DSA - John Doe Date of birth 1/171900 Patient ID: 123 Study ID Study Date and Time Study Description No of Series Study Comment Study Status ID Work St. R |Mark S 10/2/02 10:30:36 AM 11 ‘plaisir siemens Medical Solutions USA, Inc ., 2018 Page 17 Browser - Sorting Data SIEMENS . Healthineers ... Each level in Browser can be sorted by predefined criteria Keep in mind sorting will be applied to the „,content" of selected item . e.g. to sort the „Patient Level" in alphabetical order Patient Browser Patient Transfer Edit View Filter ( Sort ) Options Help · Click on . Click on · Select . Select if required Siemens Medical Solutions USA, Inc ., 2018 age 18 31 Workshop Workbook | Artis One Essentials Notes Filtering Data SIEMENS Healthineers ... Preset Display Filters can be used to filter the local database Patient Browser Patient Transfer Edit View Filter Sort Options Help . Click on · Select desired filter setting Individual Display Filters can be created by the user Patient Browser Patient Transfer Edit View Filter Sort Options Help Click on . Enter an individual name for the filter . Enter filter conditions @ Siemens Medical Solutions USA, Inc ., 2018 Page 19 Browser - Protecting Data SIEMENS . Healthineers . Data on each level can be protected . Trying to delete a protected object results in a warning message . Protected objects are indicated with „Prot“ . Click on to remove protection @ Siemens Medical Solutions USA, Inc ., 2018 Pape 20 " Artis one - Using CT/MR Images as Reference SIEMENS .. Healthineers With function CT / MR images are converted to „,XA“ images and loaded to the reference folder of the current acquisition patient Prerequisites . Images imported into correct patient folder . Image format · 512 × 512 or · 1024 x 1024 matrix images 8 / 10 / 12 bit @ Siemens Medical Solutions USA, Inc ., 2018 Page 21 32 Workshop Workbook | Artis One Essentials Notes Browser - Marking Data SIEMENS Healthineers ... Objects an be marked for various purposes . e.g. for case demonstration Marked objects are indicated in the Local Database with „M“ below the Patient Folder Local Database _ "Angio" / / / / Protim And when listed in the content area Keep in mind to configure the if you want to see marks ,, M" Work Status |Mark Status | Patient Name /11/11 Pro/M "Angio" and can be selected . Via button at the syngo keyboard · Via menu selection in @ Siemens Medical Solutions USA, Inc ., 2018 Pape 22 Delete SIEMENS. Healthineers 01.24.17-14.30 29-STD Dr. B&H; ACOU net_ Mc DSA Heren Echodaler Quart Test, do not delete DR spotfilm CD-ROM 1 FLA4D STLOY REPORT Series No Berits Date are Time |Series Descripson orming Pyaclar 7154 Theren 4/10:01 3:44:34 PM 4/18:01:3 42 55 PIA Dress physician] [secose physician] 4/10/01 3:42:32 PM 11001 142:14 PM STUDY REPORT cian] Siemens Medical Solutions USA, Inc ., 2018 Page 23 Auto Delete SIEMENS Healthineers * Local Database get automatically cleaned from unprotected, old data. Two triggers supported: 1. Database fill-state (database %) 2. Scheduled time point (Date/Time). Two rules supported to identify the data to be deleted: 1. Archived State (Archived/Sent) Daleto al studies which are cider aan 2. Age of the data (Age of data) Examples on next slide O Siemens Medical Solutions USA, Inc ., 2018 Page 24 33 Workshop Workbook | Artis One Essentials Notes Auto Delete: examples SIEMENS ..... Healthineers' Example 1: Timepoints for delebony When database fillstate has reached 80 % . Auto Delete is triggered on the 20th day of 08:00 - monthly every month at 08:00 A.M. or if Database reaches fill-state of 80% (Database fillstate . Day 20 = of every Et d monh gets triggered by syngo Resource Monitor) . The Monday of every 1 2 month Old screenshot taken from syngo FS Example 2: Data to be deleted Consider data with flags , Archived and C. Soriva contain the following nous Archived + Committed and / or - - Sent . Committed Commited' OR , Sent' OR , Sent and Commited' OR which ,reside longer than 14 Systein data is older than 14 devisi days in the system' Old screenshot taken from syngo Siemens Medical Solutions USA, Inc ., 2018 Page 25 Auto Delete: Configuration and Manual Start SIEMENS Healthineers . · Configuration dialog can be called-up by User via syngo Config Panel (Main menu: Options- >Configuration .. ) Auto Delete can be invoked at any time by user via Patient Browser menu ,Edit'->'Auto Delete' considering defined rules Siemens Medical Solutions USA, Inc ., 2018 Pape 26 Auto Delete: Manual Invocation SIEMENS.; Healthineers . Manual Auto Delete In case of manual invocation always a Do you wish to delote all studies , which are older than 14 days confirmation dialog pops up Show LISE Delete Cancel Change Dofaut Seings via button , Show List ... ' in , Manual Auto Delete' confirmation dialog a List View opens, which shows all the data of database with selection of the identified data for auto- deletion. User is able to change the selection and can execute deletion while pressing e.g. on delete icon Siemens Medical Solutions USA, Inc ., 2018 Page 27 34 Workshop Workbook | Artis One Essentials Notes Recycle Bin SIEMENS Healthineers ... Patient Browser Pationt Transfor Edt Viow Eiltor Sort Privato Applications Optiona Holo Local Databaco Schodulor RecycleBin Bat, Foot, Round DVD_F Square nume Ball, Foot, Round Study description Study doto 23 Aug- 94 PaloHE ID WM2011 Current Filter. Off . You can now restore the data to the Local Database from Recycle Bin Siemens Medical Solutions USA, Inc ., 2018 Page 28 Recycle Bin SIEMENS . Healthineers ... fromnor Configuration Contrm Deletioni Enebw image Stamo Preview for Media Do not move to Recycle Bin . Under Browser Configuration Update WorHist Autornictically on operarg Paobent Bcorner · Deselect „Do not move to Recycle Bin" Shown work status . By accident deleted patient Pwmnt delete d Tool Pool date could now be retrieved! . Remember: The storage Tool Ba capacity will not be reduced Difaut Sodogs Cancel Help Siemens Medical Solutions USA , Inc. , 2018 Page 29 Recycle Bin SIEMENS. Healthineers ... Browser Configuration Enable mage Semp Preview for M+d a D) De cot move to Macyclo Ein Recycle Bin available in the Update Werktist Achtmatically on opening Patent Browser tool pool Just move to the tool bar Shown work status . Then the icon „,Restore from Permit delete if OHmy 004 Veiled Recycle Bin" is now included in @ Corplebed O Sert the patient browser Tool Bar OK Canow Siemens Medical Solutions USA, Inc ., 2018 Page 30 35 Workshop Workbook | Artis One Essentials Notes SIEMENS Healthineers .... Questions Now's our time to inspire the future of healthcare together . Engineering success. Pioneering healthcare. @ Stermens Medical Solutions USA, Inc 36 Workshop Workbook | Artis One Essentials Day Two Examination Tab Notes SIEMENS Healthineers". Artis One Examination Tab 9 Siemens Medical Solutions USA, Inc ., 2018 Examination Tab SIEMENS Healthineers ... @ Siemens Medical Solutions USA , Inc. , 2018 Page 2 Patient data SIEMENS. Healthineers .. Display in the examination room on the Live screen and on the Info area Live Patient Peter 0123456 H AX R-D TC KO18 - 8/1/1982 ISKO18 AXIOM-Artis M VA10A 130531 Coro STUDY 1 HFS (15 0 t/s) 6/5/2013 /com//// 10:27:38 AM 1 - 5/6 FL Card M 2 83 Display in the control room Examination phant Peter SIEMENS : 6/1/1962 Physician AXICM-Artis VC20A 110405 STUDY1, Siemens Medical Solutions USA, Inc ., 2018 Page 3 37 Workshop Workbook | Artis One Essentials Notes Patient Name - „,Hidden Functions“ SIEMENS . Healthineers Patient Name, Firstn m Head First - Supine Head First - Prone Head First - Left Lateral Stand/Table Properties ? x 0 mGy Head First - Right Lateral 0.0 HGym2 10 Feet First - Supine CRAN-CAUD: RAO-LAO: 179º Feet First - Prone SID: 91.0 cm Feet First - Left Lateral Feet First - Right Lateral Tilt Angle: -0.2º X-Position: 94.5 cm Stand and T able Y-Position: 17.9 cm Card IO-Height: -3.1 cm Close Help Siemens Medical Solutions USA, Inc ., 2018 Exam Sets in VA10 SIEMENS Healthineers Artis one VA10 Up to 50 Exam Sets possible, containing . 1 Fluoro-Triplet . 1 Roadmap-Triplet Up to 16 OGPs (Organ Programs) in one Exam Set Max. 128 OGPs per Acquisition Mode Proposal to combine regular 2D, Low-Dose and 3D programs of the same body region into one Exam Set Create Exam Sets according to your workflow! @ Siemens Medical Solutions USA, Inc ., 2018 Page 5 Acquisition Modes SIEMENS Healthineers ... The following digital acquisition modes and associated postprocessing functions are possible: Digital radiography (DR) Angiocardiography (CARD) Digital subtraction angiography (DSA) Both acquisition series (scenes) and single images are possible. Angiography with stepping (peripheral angiography): PERISTEPPING PERIVISION 3D acquisition modes for 3D reconstruction: 3D DR 3D DSA Dual-axis rotational angiography (HeartSweep): The system moves the C-arm along a path containing multiple positions analog to a 3D workflow whereas the images are acquired with a CARD acquisition mode. Siemens Medical Solutions USA, Inc ., 2018 Page 6 38 Workshop Workbook | Artis One Essentials Notes Fluoro - Values & Functions SIEMENS Healthineers ... Z A+B 00:00:00 Fluoro N REPOS kv 21.3 mA 21.3 ms 21.3 Cu mm 0.0 p/s 7.5 Heat Unit % 93 @ siemens Medical Solutions USA, Inc ., 2018 age 7 Reset Fluoro Timer SIEMENS Healthineers ... TSC . Pops-up automatically Reset Fluoro Timer X System Console The fluoro timer has exceeded . Pop-up menu Do you want to reset the timer? Yes No siemens Medical Solutions USA, Inc ., 2018 age 8 Fluoro Timer Exceeded / Air Kerma Limit Reached SIEMENS Healthineers .... Reset Fluoro Alarm Accept > 2000 mGy @ Siemens Medical Solutions USA, Inc ., 2018 Page 9 39 Workshop Workbook | Artis One Essentials Notes TSC - Block Movement and Block radiation SIEMENS .... Healthineers ... Buttons located in the front but beneath the cover and can not be re- configured Blue light signals a button is activated (see also message on screen, here for example: Movement blocked) Still no Emergency Buttons! „,Demo Mode" to simulate X-ray still works, same way (demonstrating workflows etc. Siemens Medical Solutions USA, Inc ., 2018 Page 10 TSC - Onscreen menu access SIEMENS .... Healthineers .. Examination related Onscreen menus ** Siemens Medical Solutions USA, Inc ., 2018 Page 11 Exam Menu (Selecting Exam Set at TSC) SIEMENS .. Healthineers Exam set selection Shows active Exam set (e.g. here „DSA Body" If function is check marked = active Exam Set ... Overlay Ref Series Description -Detouts Dilatation Timer Siemens Medical Solutions USA, Inc ., 2018 Page 12 40 Workshop Workbook | Artis One Essentials Notes Navigating with TSC Joystick SIEMENS Healthineers". Exam menu To change Exam set move mouse joystick to menu "Exam Set" and confirm with Left mouse button "Select" Navigate Select Close Siemens Medical Solutions USA, Inc ., 2018 Pape 12 " Exam menu - Overview SIEMENS ers ... Healthineers Exam Sets CARD HDR Preview CARD CTO FL(-) Enh.Con. 2 Body 1 FL Enh.Con. 2 CARD FL(+] Enh.Con. 2 CARD EP CARE Body 2 Page CARD TAVI CARE Body 1 CARE Body.4 1 1/2 ) CARE Single CARE Card RM[-] Angio APS RM Angio APS Card Misc. RM[+) Angio APS DSA Extremities DSA Body + DSA Misc Siemens Medical Solutions USA, Inc ., 2018 Page 14 Exam menu - Selection SIEMENS Healthineers' Exam Sets CARD HDR Preview 10 Exam Sets per page can be viewed CARD CTA FUI Enn Con 2 . But up to 50 Exam Sets can be configured Baty CARD FL Enh Can 2 Page Body 4 PL[*] EnfiCos. 2 . Horizontal Mouse joystick movement to RD CARE Body 2 Page CAME Body.1 CARE BodYA toggle through pages 4 1/2 CAME SINJE RE 1 1/2) Vertical movement with Mouse to toggle Card M within a page DSA E DSA Bouy Siemens Medical Solutions USA , Inc ., 2018 Page 15 41 Workshop Workbook | Artis One Essentials Notes Exam menu - Selection SIEMENS .... Healthineers' ... Content in the Preview window is Preview referring to the highlighted Exam Body 2 FL(-) Enh.Con. 2 Set in the list Body 1 FL Enh.Con. 2 Body 4 FL(+) Enh.Con. 2 No Acquisition program selection Single CARE Body 2 possible - only preview! CARE Body. 1 CARE Body.4 Select appropriate Exam Set with CARE Single RM(-) Angio APS Select RM Angio APS RM(+) Angio APS DSA Extremities DSA Body DSA Misc Siemens Medical Solutions USA, Inc ., 2018 Page 16 Acquisition program menu - Content SIEMENS Healthineers This menu contains the Exam Set related Acquisition protocols Body 2 2 1/ The check marked program is the Body 1 1 f/s active one Body 4 4 f/s Single Single To change OGP just move mouse CARE Body.2 2 f/s vertically (browse in menu), select CARE Body. 1 1 f/s with Left click the desired program CARE Body.4 4 f/s CARE Single Single Single @ Siemens Medical Solutions USA, Inc ., 2018 Page 17 Frame Rate - Content SIEMENS .: Healthineers Live Lastrome, Firstname 3/4/2014 2:13:20 PM Single This menu contains the Acquisition 0.5 f/s protocol related frame rates 1 f/s 2 f/s The checkmarked frame rate is the active 3 f/s one 4 f/s To change frame rate just move mouse 6 f/s 7.5 f/s vertically (browse in menu), select with Left click the desired program The arrow indicates more frame rates are available but not visible Siemens Medical Solutions USA, Inc ., 2018 Page 18 42 Workshop Workbook | Artis One Essentials Notes Pulse Rate - Content SIEMENS Healthineers' ... Exam Acq Program Pulse Rate o Progrin 0.5 p/s This menu contains the Fluoro program 1 p/s related pulse rates 2 p/s The checkmarked pulse rate is the active one 3 p/s 4 p/s To change pulse rate just move mouse 7.5 p/s vertically (browse in menu), select with Left 10 p/s click the desired program 15 p/s The arrow indicates more frame rates are available but not visible Siemens Medical Solutions USA, Inc ., 2018 Page 19 Fluoro / Roadmap Program - Content SIEMENS. Healthineers ... . Depending on the active Exam Set the referring Fluoro triplet will show up Selection with mouse joystick Depending on the configuration the default chosen Fluoro program can be either the FL normal or FL - . When Roadmap is enabled there is instead of Fluoro Program the Roadmap program available plus the Roadmap menu FL(-) Neuro 7.5 p/s RM(-) Angio APS FL Neuro 10 p/s v RM Angio APS 10 p/s v FL(+) Neuro 15 p/s RM(+) Angio APS 15 p/s Siemens Medical Solutions USA , Inc . , 2018 Pap 20 Fluoro / Roadmap Program - Content SIEMENS. Healthineers .. . Depending on the configuration the system shows either Vessel Catheter Contras or Anatomical Background Can be configured via Examination Taskcard - Acquisition - Set ... Patient Acquisition Options Help Lastr Exam Set Editor Patie Change Password 3/4 Reset Password 3/4/2 hertoto cal Background Reset Roadmap Reset Roadmap X Exit Roadmap X Exit Roadmap Siemens Medical Solutions USA, Inc ., 2018 Page 21 43 Workshop Workbook | Artis One Essentials Notes Fluoro Display Mode - Overlay Ref SIEMENS . Healthineers' ... Siemens Medical Solutions USA, Inc ., 2018 KAC E ERIE Page 22 Overlay Reference image SIEMENS .. Healthineers' ... Overlay Reference image - Overlay Reference including Graphics Graphics that are stored with a reference image are now visible when this reference image is used for , Overlay Reference' Use e.g. arrow, circle or line tools to point out important structures before storing the reference image for overlay . May be used instead of the pointer or markers on the monitor Be Aware: The pointer is not a graphic, thus it is not stored with an image! @ Siemens Medical Solutions USA , Inc . , 2018 Page 23 Overlay Reference image SIEMENS Healthinpers Adjustment of Overlay % influences the visibility of Ref Image, not the graphics . Overlay 30% Overlay 0 % . Only graphics visible @ siemens Medical Solutions USA, Inc ., 2018 Page 24 44 Workshop Workbook | Artis One Essentials Notes Roadmap SIEMENS Healthineers' ... SOR Exam Set Roadmap Owiriay Ret Serios Description Dilatation Timer Roadmap Activation At Artis Workplace Via OSD drop-down menu Via TSC, if configured edical solutions USA, Inc ., 2018 Page 25 Roadmap SIEMENS Healthineers ... Roadmap Function 1st Phase: native 2nd Phase: subtracted Inject symbol in right lower corner on monitor · Release footswitch 3rd Phase: subtracted Siemens Medical Solutions USA , Inc ., 2018 age 26 Roadmap SIEMENS Healthineers ... Vessel Catheter Contrast - or - Anatomical Background SOR Vosnel Catheter Contrast 7 Reout Roodmap X Exit Roadmap Anatomical Backorounit Roast Roadmap X Exit Roadmap siemens Medical Solutions USA, Inc ., 2018 Page 27 45 Workshop Workbook | Artis One Essentials Notes Roadmap SIEMENS . bers :: Healthineers' Options Help Exam Ser Editor Change Password Set Vessel / Catheter Contrast Activato Fluoro on Handswitch Switch between 'Vessel Catheter Contrast' and 'Anatomical Background' The user can select in the 'Examination' task card which of the both functions shall be available via OSD menu Siemens Medical Solutions USA , Inc ., 2018 Page 28 Roadmap SIEMENS. Healthineers Utilize 'Vessel Catheter Contrast' Function Select Roadmap OSD menu Vessel Catheter Contrast is checked Activate Vessel Catheter Contrast . Vessel Catheter Contrast is highlighted and shows joystick symbol Use Joystick to adapt values FOR % Vassal Catheter Contrast Reset Roadmap X Et Roadmap Po FOR Vessel Catheter Contrast 0 Reset Roadmap X Fxil Roadmap @ siemens Medical Solutions USA, Inc ., 2018 age 29 Roadmap „Vessel/Catheter Contrast“ SIEMENS Healthineers ... How to adjust the vessel/catheter contrast In the fill image the system takes: · Vessel contrast max. 200% Vessel contrast min. 0% From the fluoro image the system takes: · Catheter contrast max. 200% . Catheter contrast min. 50% . Not less than 50% possible - because then the fluoro wouldn't be visible @ siemens Medical Solutions USA, Inc ., 2018 Page 30 46 Workshop Workbook | Artis One Essentials Notes Vessel/catheter contrast during Roadmap SIEMENS . Healthineers . Vessel/catheter contrast during Roadmap phase 3, but not during X-ray, the vessel/catheter contrast can be adjusted for Roadmap images. The initial values for Vessel Contrast and Catheter Contrast are defined in the Roadmap program. . Press the Vessel/Catheter Contrast button. Deflect the mouse joystick. . Select Vessel Catheter Contrast in the Roadmap menu. Examination room, TSC (if configured) . Press this button. [D]> · To change the vessel/catheter contrast Catheter Up: more vessel in the examination room: Down: less vessel Left: more catheter Right: less catheter Vessel @ Siemens Medical Solutions USA, Inc ., 2018 Page 31 Roadmap SIEMENS Healthineers ... Automatic Reset . Automatic reset of Roadmap after C-Arm rotation . No automatic reset after table movements Zoom Change During Roadmap . Changing FD format will temporarily deselect Roadmap and show native Fluoro instead Returning to the previously used FD format will automatically reselect the previous Roadmap Mask and Roadmap continues @ Siemens Medical Solutions USA, Inc ., 2018 Page 32 Storing a fluoroscopic scene (optional) SIEMENS Healthineers ... Fluoroscopy or roadmap scenes with up to 1024 frames can be stored. . You can store the last fluoroscopy or roadmap scene. · Save MUST be complete before fluoro again to ensure all desired frames are saved. @ Siemens Medical Solutions USA, Inc ., 2018 Page 33 47 Workshop Workbook | Artis One Essentials Notes Exam Set Editor SIEMENS. Healthineers Access button in Control room Expanded layout/structure CAPD CARDER CARD HOM CARD BACHUP OSPS - Siemens Medical Solutions USA, Inc ., 2018 Page 34 Exam Set Editor SIEMENS Healthineers . The Exam Set and program editor appears . Exam sets listed in tree view . Click on to open all exam sets . Click on to close all exam sets CARD P CARD CAR CAD CARD A CARD BACKUP CISPS The active Exam Set is marked with bold letters The current OGP is highlighted @ Siemens Medical Solutions USA , Inc ., 2018 Page 35 To view/change/organize the Exam Sets SIEMENS Healthineers .. . To organize/edit parameters: Expert >>> CARD 3016 " A password is required for changing - CARD Paj- parameters - CARD FOR - CARD MEDIA CARD BACKUP OOPS LogIn with "Artis": go to LOGIN, type in the IP DDA Special password, changing parameters is now possible Siemens Medical Solutions USA, Inc ., 2018 Page 36 48 Workshop Workbook | Artis One Essentials Notes Viewing a Exam Set SIEMENS Healthineers ... 24Exam Set and Program Fazer Cardiac Expert ». o Display Fluoro Display Roadmap Display Roadmap 1P CARD Ped DSA Special DSA 7.5 (7.5 fls) * êDGh General DSA long (2 f/s) * * Neum DSA Venous (4 f/s) 12DSA THoras > DR ACQ /2 fisi (PPNIVision (US) ~ Display Fluoro des FL - Angio (7.5 p/s) (PariStepping Display Roadmap FL Angio (10 p/s) la Overview OR (3 M/s) [sOversisw DSA ( fr) 28 FL+ Angio (10 p/s) Ja AlternativeAcq. 0Tb Mhh Flugm Angio low (7.5 nis) 45 Flvere Angle med (10 p/s) di Fluam Angia high (il p) DSA Special DSA 7.5 (7.5 fis) DSA long (2 f/s) ** DynaCT Head DSA Venous (4 f/s) 7 DynaCT Dady ªDynaCT Cardiac DR ACQ (2 f/s) RM - Angio (7.5 p/s) Activate Exart Set and Program RM Angio (15 p/s) Siemens Medical Solutions USA, Inc ., 2018 RM + Angio (15 p/s) Page 37 Applying Exam Sets SIEMENS . Healthineers ... - Mark the required exam set in the tree view Click Activate Exam Set and Program LDS Exam set is transferred to the ERET.Dijk Examination task card CHAT-CARDAPEDIRTR - Double click the Acquisition *********************** Program. This would activate the .................... default 1st acquisition program and the middle fluoro program. Siemens Medical Solutions USA, Inc ., 2018 Page 38 Renaming an Exam Set SIEMENS . Healthineers ... . Click the required exam set. . Overwrite or change the existing name. . Confirm with Store Exam Set Properties Exam Set Name: DSA Special Store Exam Set Properties @ Siemens Medical Solutions USA, Inc ., 2018 Page 39 49 Workshop Workbook | Artis One Essentials Notes Changing name of an OGP SIEMENS Healthineers". - Mark the OGP Right-click it Carces:4 Vs PI6 DO HO Select Rename from the context menu CAST-CARD PEDMTA - Overwrite/change name, click Cadse costi O.K. button ...................... Program name will be changed in all exam sets @ Siemens Medical Solutions USA, Inc ., 2018 Page 40 Storing/Applying an OGP SIEMENS Healthineers ... Change the OGP name in the „program" window @ siemens Medical Solutions USA, Inc ., 2018 Page 41 Filtering/Organizing Exam Sets SIEMENS Healthineers .... Go to the "Organize" tab card ff Chepla- Paarse CRACK Filter function (acquisition Off Owrit ww PI6_DR LD programs, roadmaps, fluoros) LonaLeg ............. The highlighted OGP's are used P CRS1-CARD PELAMTR in an exam set - The non-highlighted are not used .......... Siemens Medical Solutions USA, Inc ., 2018 Page 42 50 Workshop Workbook | Artis One Essentials Notes What is also possible with the new exam set editor? SIEMENS Healthineers ... Drag&Drop from OGP's and exam sets: DRACO "Within exam sets you can PIEDILLD Pie_DR HD drag&drop -The exam sets itself R31.CAFO PEDANTE LD From organize tab card to exam sets Siemens Medical Solutions USA, Inc ., 2018 Page 43 Measurement Fields for Dose Regulation SIEMENS . Healthineers ... . System Console . TSC Measure Field ms 100 Focus Cu mm Dilatation Siemens Medical Solutions USA, Inc ., 2018 Page 44 Edit Series Description SIEMENS. Healthineers Customizing a Series Description - At the console Click on .... Click on .... Enter/change description Siemens Medical Solutions USA, Inc ., 2018 Page 45 51 Workshop Workbook | Artis One Essentials SIEMENS Notes Healthineers ' Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. 52 Workshop Workbook | Artis One Essentials ClEARStent Notes SIEMENS Healthineers . Artis with PURE CLEARStent @ Siemens Medical Solutions USA, Inc ., 2017 CLEARStent SIEMENS ..... ers:: Healthineers . . Principle of CLEARstent Workflow CLEARstent Dynamic . CLEARstent Dynamic „Offline“ @ Siemens Medical Solutions USA, Inc ., 2017 Page 2 Goals and Challenges SIEMENS .. Healthineers ... Goals Improve the visibility of stents (especially newer generation) Show inflation status and stent struts Challenges Stent movement Low object contrast Image noise @ Siemens Medical Solutions USA, Inc ., 2017 Page 3 53 Workshop Workbook | Artis One Essentials Notes Basic Idea SIEMENS Healthineers' .... Method Average registered frames (marker- based) Register & Average Frames Result Single reference image with Reduced noise Enhanced contrast of struts Page 4 Averaging SIEMENS Healthineers .... Average the marker-aligned images (5 ... 10 images) Resulting image with higher contrast and less noise Image 1 Image 2 Image 3 @ Siemens Medical Solutions USA , Inc ., 2017 Page 5 Compare SIEMENS .: Healthineers Compare resulting image with one image from scene @ Siemens Medical Solutions USA , Inc. , 2017 Page 6 54 Workshop Workbook | Artis One Essentials Notes CLEARstent Dynamic SIEMENS Healthineers ... CLEARstent Dynamic offers a static reference image plus a dynamic CLEARstent scene if contrast was injected CLEARstent CLEARstent scene reference image Live screen Assist screen Page 7 CLEARstent in Postprocessing SIEMENS . Healthineers ... CLEARstent in postprocessing is (still) possible with: Any unsubtracted cardiac scene or fluoroscopy If there are enough images available (at least 25 frames) CLEARstent in postprocessing is (still) not possible with: DSA scences (even displayed natively) Rotational scences/Dynavision - DR SM images/Ref images Together with Overlay/Ref @ Siemens Medical Solutions USA, Inc ., 2017 Page 8 Workflow CLEARstent SIEMENS . Healthineers .. Place the balloon with the two markers to the desired position: Which can be an already deployed stent . Or a second stent needs to be attached with an overlap etc. Either select: CLEARstent OGP in the Exam set Or use it as an Alternative acquisition @ Siemens Medical Solutions USA , Inc ., 2017 Page 9 55 Workshop Workbook | Artis One Essentials Notes Workflow CLEARstent SIEMENS ..... Healthineers ** System acquires now native images (minim. 25 frames) Then the syringe symbol appears This symbol launches phase 2 of the CLEARstent acquisition and the doctor a) Should now inject contrast b) Finish the acquisition till scene stops automatically CLEARstent is processed in the background but preliminary CLEARstent reference image is displayed on the REF screen Siemens Medical Solutions USA, Inc ., 2017 Page 10 CLEARstent Dynamic Scene - How it Looks SIEMENS.:: Healthineers ... 100% Stent visible 0% Stent visible Siemens Medical Solutions USA, Inc. , 2017 Page 11 CLEARstent - ,, offline“ SIEMENS. Healthineers .... PLUOND 150 KCAY It is possible to apply CLEARstent in postprocessing mode PostProc Fluoro or Acquisition (Card) is possible Just click on the dedicated icon (or the button on Touch2Move) If contrast is detected - CLEARstent Dynamic scene appears plus the CLEARstent reference image If no contrast is detected - CLEARstent reference image appears Page 12 56 Workshop Workbook | Artis One Essentials Notes CLEARstent - Loading images for review SIEMENS .. : Healthineers The CLEARstent reference image is stored in the Reference Directory @ Siemens Medical Solutions USA, Inc ., 2017 Page 13 CLEARstent Dynamic SIEMENS. Healthineers ... Loading images for review CLEARstent Dynamic scene is stored in the Scene Directory Siemens Medical Solutions USA, Inc ., 2017 Page 14 SIEMENS Healthineers' ... Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. @ Siemens Medical Solutions USA, Inc ., 2017 57 Workshop Workbook | Artis One Essentials ClEARStent Live Notes SIEMENS Healthineers Artis PURE Essentials CLEARStent Live O Siemens Medical Solutions USA, Inc ., 2017 CLEARstent Live SIEMENS .... Healthineers ... Why CLEARstent Live? Workflow Requirements Pitfalls @ Siemens Medical Solutions USA, Inc ., 2017 Page 2 CLEARstent Live SIEMENS ..... Healthineers Why CLEARstent Live? CLEARstent Live should help the doctor to focus on the stent only (e.g. bifurcation stenting) It considers the new stent generation and lower doses in angiographic procedures It stabilizes the object close to the balloon markers (stent) when doing a fluoro-like acquisition Meaning it offers a static image of the stent overlaid on live fluoro while the background is still moving CLEARstent Live assists the doctor to be faster with the procedure @ Siemens Medical Solutions USA, Inc ., 2017 Page 3 58 Workshop Workbook | Artis One Essentials Notes CLEARstent Live SIEMENS . Healthineers ** Why CLEARstent Live? CLEARstent dynamic or CLEARstent reference image also is helpful to detect malpositioning of stents But no real time stent enhancement Doctor needs to stop the workflow, wait till CLEARstent calculation finished, check CLEARstent dynamic scene and/or CLEARstent reference image, correct stent result if necessary and continue It is maybe time consuming @ Siemens Medical Solutions USA, Inc ., 2017 Page 4 CLEARstent Live SIEMENS .. : Healthineers It takes information from several Frames and enhances the stent Heart (hence arteries) moves = CLEARstent (Live) algorithm works E.g. femoral arteries no pulsation = no movement = CLEARstent doesn't work properly Page 5 @ Siemens Medical Solutions USA, Inc ., 2017 CLEARstent Live SIEMENS Healthineers ... Frame 1 Frame 2 Frame 3 Frame N Dosisrate Summation of n-images Information from several Frames Page 6 @ Siemens Medical Solutions USA, Inc ., 2017 59 Workshop Workbook | Artis One Essentials Notes CLEARstent Live SIEMENS .. Healthineers ** Software searches Balloon Marker in each image Aligns images in such a way that markers are at same position. Calculate average from all images Zoom and center the resulting image Special image post-processing Register & What will we gain? averaging of Frames Image with reduced noise and improved stent contrast Siemens Medical Solutions USA, Inc ., 2017 Page 7 CLEARstent Live SIEMENS. Healthineers ... Equipment/Requirements - Display modes SHOWSThe" REF 1 Shows If an optional Reference screen is available acquisition CLEARstent Live CLEARstent Live is always displayed on the REF 1 screen Live and REF 1 screen available Live screen REF 1 Shows CLEARstent Live Reference screen shows live blank acquisition Live, REF 1 and reference screen available Siemens Medical Solutions USA, Inc ., 2017 Page 8 CLEARstent Live SIEMENS . Healthineers CLEARstent Live - example - Normal acquisition without contrast In Fluoro and acquisition stent is almost not visible Difficult to position second stent in main branch Customer decides to apply CLEARstent Live Compare CLEARstent Live video next slide O Siemens Medical Solutions USA, Inc ., 2017 60 Workshop Workbook | Artis One Essentials Notes CLEARstent Live SIEMENS Healthineers CLEARstent Live - example video Live REF 1 @ Siemens Medical Solutions USA, Inc ., 2017 CLEARstent Live SIEMENS Healthineers ... CLEARstent Live - Real Time Verification Live monitor shows Live acquisition REF 1 Shows CLEARstent Live . On Assist screen Doctor sees directly the enhanced and stabilized CLEARstent Live image . On live screen normal acquisition is shown . With CLEARstent Live also injection of contrast is possible . Here real time verification possible Page 11 @ Siemens Medical Solutions USA, Inc ., 2017 CLEARstent Live- Workflow SIEMENS .... Healthineers. Workflow - Before you start CLEARstent Live · Important to understand: CLEARstent Live is acquisition not fluoroscopy . The dose of the OGP can be close to the dose usually taken for fluoroscopy (CLEARstent Live LD) · Max. possible scene length = 20 sec. (frame rate of 7, 5 f/s) · Scene length defined in the OGP (depending from frame rate) · CLEARstent Live is used when fluoroscopy doesn't offer an adequate image quality As soon as you stop acquisition - CLEARstent Live workflow stops (or when max. scene length is reached Siemens Medical Solutions USA, Inc ., 2017 Page 12 61 Workshop Workbook | Artis One Essentials Notes CLEARstent Live- Workflow SIEMENS ... Healthineers Select OGP or, if configured, use Alternative acquisition Acquire scene and keep foot pedal pressed down! Siemens Medical Solutions USA, Inc ., 2017 Page 13 CLEARstent Live- Workflow SIEMENS ..... Healthineers ... Workflow - CLEARstent Live On Live screen following messages appear: Message ,, CLEARstent Live in preparation" appears (system searches for adequate images) . Then message „,CLEARstent Live processing" appears (images found, post processing in progress) @ Siemens Medical Solutions USA, Inc ., 2017 Page 14 CLEARstent Live Workflow SIEMENS .... Healthineers ... Finished CLEARstent Live acquisition Scheaber CLEAR Suit_J.h. ......... CLEARstent Live scene stored in database within scene folder Post processing only possible with acquisition not with CLEARstent Live scene @ Siemens Medical Solutions USA, Inc ., 2017 Page 15 62 Workshop Workbook | Artis One Essentials Notes CLEARstent Live Workflow SIEMENS Healthineers ... Workflow - Review CLEARstent Live images BRO a CALUS 20 CAUS @ Siemens Medical Solutions USA, Inc ., 2017 Page 16 CLEARstent Live -- Reqirements SIEMENS . Healthineers ... Equipment/Requirements-Available zoom sizes 20x20 Flat Detector All zoom sizes possible 30x40 Flat Detector Zoom 3 and higher @ Siemens Medical Solutions USA, Inc ., 2017 Page 17 CLEARstent Live Requirements SIEMENS CLEARstent Live OGP - Footswitch CLEARstent Live can be called up as a normal OGP and is also available as Alternative acquisition Please Note: The OGP is not deselected automatically when finished CLEARstent acquisition (different behavior to CLEARstent Dynamic!) CLEARstent Live OGP can be configured as the first program (=default program) in exam set Page 18 Siemens Medical Solutions USA, Inc ., 2017 63 Workshop Workbook | Artis One Essentials Notes CLEARstent Live Requirements SIEMENS Healthineers Equipment/Requirements - Biplane systems Artis Q/Q.zen - CLEARstent Live is available on plane A & B for Artis Q as well as Q.zen But not on both planes simultanously . CLEARstent Live scene is processed from Master plane (=active plane) - Other plane shows only live image Siemens AG 2015 All rights reserved . Page 19 CLEARstent Live- Pitfalls SIEMENS Healthineers ** Pitfalls . CLEARstent OGP selected and acquisition released but no CLEARstent post processing? Wrong zoom size? In user manual no zoom sizes are defined, teach error message and zooms carefully, acquisition with CLEARstent Live OGP is possible) Auto Processing ,, CLEARstent live" is not configured in OGP? . No VFR time active - no two phases - no CLEARstent Live processing Balloon markers visible? License key? Alternative acquisition not configured? @ Siemens Medical Solutions USA, Inc ., 2017 Page 20 SIEMENS Healthineers Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. 3 Siemens Medical Solutions USA, Inc ., 2017 64 Workshop Workbook | Artis One Essentials Special Examinations: PERIVISON - Peristepping Notes SIEMENS . Healthineers' ... Artis one Special Examinations PERIVISION Peristepping @ Siemens Medical Solutions USA, Inc ., 2018 Stepping Techniques SIEMENS Healthineers ... @ Siemens Medical Solutions USA, Inc ., 2018 Page 2 PERIVISION SIEMENS .... Healthineers ... Step-by-Step serial acquisition in on-line subtraction technique for peripheral run-off Display of all peripheral vessels with one contrast media injection . Online subtracted display Frame rate selection for each step seperately (Configured in Exam Set) · 0.5 / 1 / 2 / 3 / 4 fps . Duration per step controlled by user @ Siemens Medical Solutions USA, Inc ., 2018 Page 3 65 Workshop Workbook | Artis One Essentials Notes Peristepping (= DR Stepping) SIEMENS Healthineers ... Step-by-Step serial acquisition for peripheral run-off All peripheral vessels displayed unsubtracted with one contrast media injection Frame rate selection for each step seperately . 0.5 / 1 / 2 / 3 / 4 fps Duration per step controlled by user @ Siemens Medical Solutions USA, Inc ., 2018 Page 4 PERIVISION VS. PERISTEPPING SIEMENS .. Healthineers .... PERIVISION PERISTEPPING Test run Test run for collimation settings for collimation settings Mask run from feet to pelvis Return back to start . Injection of contrast media . Injection of contrast media Fill run from pelvis to feet Fill run from pelvis to feet Test run Test run In< Mask run return to start Fill run Fill run @ Siemens Medical Solutions USA, Inc ., 2018 Page 5 PERIVISION / Peristepping SIEMENS ..... Healthineers Step-by-Step Position patient Define Start position With table [Zee Floor, Zee Biplane] or C-Arm [Zee MP, Zee Ceiling, and Zeego] . Select the required Peri Program · Short Fluoro in position #1 · Use C-Arm Joystick to move the C-Arm or Table (MP: to move the C-arm) stepwise to end position) . Prepare Injector Start Acquisition (hand switch or foot switch) . Mask run is performed automatically (PERIVISION) · Table or C-arm moves back to starting position (Peristepping) . Injection is triggered in the starting position (Injector sync'd) . Trigger the stepping for each position is manually with multi-functional button on exposure handswitch @ Siemens Medical Solutions USA, Inc ., 2018 Page 6 66 Workshop Workbook | Artis One Essentials Notes PERIVISION / Peristepping SIEMENS . Healthineers System Positionning C-Arm Position · FD in position (PA) Maximum SID . Table as close to FD as possible Collimation & Measurement fields Proper collimation for each step individually . Correct measurement fields for each step . Both lateral for both legs/Unilateral or center for one leg Transparency Compensation · Semi-transparent filters or similar devices @ Siemens Medical Solutions USA, Inc ., 2018 Page 7 PERIVISION / Peristepping SIEMENS. Healthineers Important Notes I System Positions for Peri for Zeego · Left Side . Right Side . Right/Left Side 15 and Right side 30 degree positions System Positions for Peri for Zee Ceiling · Left Side Right Side System Positions for Peri at Zee Floor and Zee Biplane systems · Left Side . Left Side, Table Rotated . Right Side, Table Rotated Use max. SID (Table height as high as possible) Position patient as close as possible to the FD Transfer Peristepping/Perivision to X Workplace for Composing Software (Optional) Page 8 PERIVISION / Peristepping SIEMENS Healthineers ... Patient Positioning @ Siemens Medical Solutions USA, Inc ., 2018 Page9 67 Workshop Workbook | Artis One Essentials Notes PERIVISION / Peristepping SIEMENS .: Healthineers . Feet Fixation @ Siemens Medical Solutions USA, Inc ., 2018 Page 10 PERIVISION / Peristepping SIEMENS ... Healthineers ... Measurement Fields Make sure the object of interest is in the measurement field! Siemens Medical Solutions USA, Inc ., 2018 Page 11 PERIVISION / Peristepping SIEMENS . Homogenization Healthineers ... Make sure an absorbent material is used! @ Siemens Medical Solutions USA, Inc ., 2018 Page 12 68 Workshop Workbook | Artis One Essentials Notes PERIVISION / Peristepping SIEMENS. Healthineers Contrast Injection Make sure enough contrast is injected with the proper flow rate! @ Siemens Medical Solutions USA, Inc ., 2018 Page 13 PERIVISION / Peristepping SIEMENS . Healthineers Stepping Artifacts Minimize movement to avoid artifacts @ Siemens Medical Solutions USA, Inc ., 2018 Page 14 AX Composing-Angiographic Long Leg Module SIEMENS .. Healthineers . Syngo Composing software on syngo XWP (Optional) Generate full representations of the peripheral vessels of one leg or both legs from Perivision or PeriStepping software. Page 15 @ siemens Medical Solutions USA, Inc ., 2018 69 Workshop Workbook | Artis One Essentials SIEMENS Notes Healthineers' ... Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. @ Siemens Medical Solutions USA, Inc ., 2018 70 Workshop Workbook | Artis One Essentials HeartSweep Notes SIEMENS Healthineers Artis one HeartSweep @ Siemens Medical Solutions USA, Inc ., 2018 HeartSweep - General SIEMENS .: Healthineers ... What is HeartSweep? . A special CARD acquisition mode (Dual-axis rotational angiography) . Intended to visualize the coronary arteries in different double-oblique views by just one acquisition run using a single contrast injection . It provides not only a movement in either RAO/LAO or CRAN/CAUD but a combination of both . During a HeartSweep run the C-arm moves along a pre-defined path covering multiple projections . The trajectory for HeartSweep is defined and customized in Local Service Configuration Siemens Medical Solutions USA , Inc. , 2018 Page 2 HeartSweep - General SIEMENS . Healthineers ... What is HeartSweep? @ Siemens Medical Solutions USA, Inc ., 2018 71 Workshop Workbook | Artis One Essentials Notes HeartSweep Workflow SIEMENS Healthineers' .... Preparations - Positioning for HeartSweep Trajectory The HeartSweep acquisition path is defined by a trajectory with up to 15 points which can be defined by Siemens Service. The trajectory must start at an Anatomical Position. Isocenter With rotational angiography, the volume to be imaged should always lie in the isocenter of the C-arm, i.e. center of rotation. Otherwise it may move out of the image area in some projections. The "isocenter assistant" helps you positioning the region of interest in the isocenter. (- Page 430 Isocenter assistant) PLEASE NOTE: . HeartSweep is possible from Head Side system position with table in 0º Rotation only . Collimation (slab mode) is possible · All zoom sizes are permitted to be chosen after HeartSweep program is invoked . A Test run is required and mandatory @ Siemens Medical Solutions USA, Inc ., 2018 Page 4 HeartSweep Workflow SIEMENS. Healthineers Preparations - Positioning for HeartSweep Collisions The effect of a collision depends on in which state of the rotational angiography examination the collision occurs: " If a collision occurs before the first run is started, the system returns to the test phase and does not deselect the acquisition. If a collision occurs while there is no rotational movement, e.g. acquisition in injection phase or X-ray delay from injector, the system displays a message and does not deselect the acquisition. . It a collision occurs during the movement (collision sensor), then the movement stops. The acquisition and the injection are stopped, the acquisition program is deselected by it, and the acquisition cannot be continued. Artis one | VA10 409 Print No. AXA4-020,620.01.02.02 Siemens Medical Solutions USA, Inc ., 2018 Page 5 HeartSweep Workflow SIEMENS Healthineers .. Preparations - Positioning for HeartSweep Patient movements If the patient moves during a rotational angiography acquisition, there is a risk of collision and also the acquired scenes may not be suitable for the intended purpose. Instruct the patient not to move, or immobilize the patient, if necessary. Pay attention to patient movements during a rotational angiography acquisition and stop the acquisition/movement, if necessary. PLEASE NOTE: It is the responsibility of the customer to instruct the patient accordingly Siemens Medical Solutions USA, Inc ., 2018 Page 6 72 Workshop Workbook | Artis One Essentials Notes HeartSweep Workflow SIEMENS Healthineers' ... Preparations - Preparing Contrast injection Injection mode The injection occurs just before start of fill run. Contrast medium can either be applied with the help of an automatic injector or manually. In general, injection with the injector produces better results as the flow of the contrast medium can be kept constant over the total duration of the injection. If the injector is set to "Armed" it will be triggered. It is recommended to set a delay time (X-ray delay) of 0.5 to 1 s on the injector. With it, an optimum contrast medium filling is achieved already with the first projection. The X-ray delay which is programmed at the injector is used to delay the begin of the injection phase. During this delay time, there is no image acquisition. Siemens Medical Solutions USA, Inc ., 2018 page? HeartSweep Workflow SIEMENS . Healthineers. Preparations - Preparing Contrast injection If the injector is not set to "Armed", the system assumes that a manual injection is performed with no contrast medium applied and starts the injection phase immediately. For manual injection, it is recommended to set an X-ray delay of O S. Caution Injector not connected correctly or not set to "armed" before starting acquisitions especially in modes PERIVISION, DYNAVISION, or 3D Risk of X-ray radiation applied without diagnostic use Before releasing acquisition with contrast medium: . Ensure that the Injector is set to "armed". # Check messages displayed by the system. # In case of errors with injector triggering, inject manually. Siemens Medical Solutions USA, Inc ., 2018 Page 8 HeartSweep Workflow SIEMENS Healthineers Executing HeartSweep acquisition mode A HeartSweep acquisition is performed in the following sequence: 1 Prepare the patient, stand, C-arm and table. Check the injector, it used. 2 Select a HeartSweep acquisition program. 3 Position the heart in the isocenter. You can start immediately if the LED on the Isocenter key is lit. Follow the "isocenter assistant" if the LED on the Isocenter key is flashing. The message HeartSweep Start Position: Activate stand movement is displayed. @ Siemens Medical Solutions USA, Inc ., 2018 Page 9 73 Workshop Workbook | Artis One Essentials Notes HeartSweep Workflow SIEMENS ..... Healthineers' .... Executing HeartSweep acquisition mode The message HeartSweep Start Position: Activate stand movement is displayed. Move C-arm to start position: Press down the stand joystick and deflect it. Depending on the type of injection, one of the following messages is shown: HeartSweep test phase: Auto, Activate stand movement with automatic control HeartSweep test phase: Manual, Activate stand movement with manual control (+ Page 418 Automatic/manual control) Perform the HeartSweep test run to make sure that no collision will occur. @ Siemens Medical Solutions USA, Inc ., 2018 Page 10 HeartSweep Workflow SIEMENS Healthineers Executing HeartSweep acquisition mode 5 Press down the stand joystick and deflect it forward until the target position is reached. Or press the hands free foot pedal. The message Test Phase: Start Fluoro to complete Test Phase is displayed. The test phase can be interupted at any time by releasing stand i joystick or hands free foot pedal. If you deflect the joystick or press the foot pedal again within 20 s, the system will proceed with the test run. After more than 20's, the test phase must be repeated. Siemens Medical Solutions USA, Inc ., 2018 Pape 11 HeartSweep Workflow SIEMENS.; Healthineers Executing HeartSweep acquisition mode 6 Perform a brief fluoroscopy for automatic setting of acquisition parameters: Press fluoro pedal of footswitch. Ready for HeartSweep: #s Acquisition Time is displayed. 7 Automatic or manual injection if contrast medium is used. Start injector if manual injection is used. Perform the HeartSweep acquisition run: Press the exposure release button or pedal and keep it pressed until the end of the DR-DYNAVISION acquisition, i.e. until the fill phase is automatically completed. Start acquisition: Press the exposure release button or pedal and keep it pressed. Rotational run will start automatically, if Auto is programmed. Injection will also be performed automatically if the injector is set to "Armed". Siemens Medical Solutions USA, Inc ., 2018 Page 12 74 Workshop Workbook | Artis One Essentials Notes HeartSweep Workflow SIEMENS Healthinpers ... Executing HeartSweep acquisition mode 9 Let go the exposure release when rotational run is complete. (Acquisition is stopped automatically.) HeartSweep: Completed is displayed. 10 View the rotational series. PLEASE NOTE: HeartSweep is a rotational run but not a 3D acquisiton, therefor it is displayed in Postprocessing taskcard and not in 3D viewer Depending on the configuration, the system can be returned with „automatic run: activate stand movement" into the previously used working position @ siemens Medical Solutions USA, Inc ., 2018 Page 13 HeartSweep Workflow SIEMENS ..... Healthineers ... Return to previous working position . Due to that HeartSweep is performed in Head Side system position it might be necessary to leave the actual working position If the corresponding function is enabled in 'Service Mode' and movement is executed after HeartSWeep acquisition, the system may move back to the previous working position During the automatic run it automatically selects all geometrical parameters which where applied in that position. @ Siemens Medical Solutions USA, Inc ., 2018 Pagepage 17 SIEMENS Healthineers .. Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. Siemens Medical Solutions USA, In 75 Workshop Workbook | Artis One Essentials Day Three Post Processing and Filming Notes SIEMENS Healthineers Artis one Post Processing and Filming @ Siemens Medical Solutions USA, Inc. 2018 Postprocessing - Image Area SIEMENS. Healthineers' ... 2 IMA 1 Click, Click, to page reverse to page forward 1024 @ siemens Medical Solutions USA, Inc ., 2018 General Processing Functions SIEMENS Healthineers ... Sampleman John Soune Navigation in Scenes & Images Scene Ref. Image Store Monitor . Ref. Image + Store Monitor R 10 f/s Dynamic Review of Scenes Store, Copy & Transfer, Film Preview @ Siemens Medical Solutions USA, Inc ., 2018 76 Workshop Workbook | Artis One Essentials Notes Navigation in Directories SIEMENS Healthineers ** Sampleman John Scene Scene Scone Ret Image Store Monitor + Ref. Image . Store Mentor Siemens Medical Solutions USA, Inc ., 2018 Replay Functions SIEMENS . Healthineers Dynamic Review of Scenes Stop In acquisition rate In slow motion In fast review OSA VER Single Step Review CARD 15 f/s Stop Siemens Medical Solutions USA, Inc ., 2018 Post Processing Sub task cards SIEMENS .. Healthineers View | Image | DSA View | Image | DSA View | Image | DSA K R MI jopac Jopac @ Siemens Medical Solutions USA, Inc ., 2018 77 Workshop Workbook | Artis One Essentials Notes Series Overview SIEMENS .. Healthineers" View Image DSA ---- @ Siemens Medical Solutions USA, Inc ., 2018 Electronic Shutter SIEMENS ... Healthineers ... Normal display Electronic Shutter Applied @ Siemens Medical Solutions USA, Inc ., 2018 Normal versus Inverted SIEMENS ... Healthineers Normal display Inverted display @ Siemens Medical Solutions USA , Inc . , 2018 78 Workshop Workbook | Artis One Essentials Notes Acquisition Size/2K Imaging SIEMENS. Healthineers ** 2480 × 1920 48cm Format, 2480 x 1920 pixel Monitor. 1024 x 1024 pixel Acquisition Size: enabled. A part of the image is displayed on the monitor but without ing. The image can be panned around. Siemens Medical Solutions USA, Inc ., 2018 Pixelshift SIEMENS ... Healthineers .. Auto Pixel Shift Manual Pixel Shift Flexible Pixel Shift Origina Pixel Shift @ Siemens Medical Solutions USA, Inc. , 2018 Flexible Pixel Shift in Post Proc SIEMENS .. Healthineers ... Pixelshift ? X 024 auto EE 5% AB 0% FLEX WB 2800 WC 60 Close Help Do not forget to save the changes with "Store Monitor"! @ Siemens Medical Solutions USA, Inc ., 2018 79 Workshop Workbook | Artis One Essentials Notes Averaging-Improve Noise Suppression SIEMENS ... Healthineers No Average Average - Mask 4 avg. Fill 2 avg. @ siemens Medical Solutions USA, Inc ., 2018 Biplane/Dual Monitor Configuration SIEMENS . Healthineers ... RE A B @ Siemens Medical Solutions USA, Inc ., 2018 Image/Scene Compare-Dual Monitor (Biplane) SIEMENS . Healthineers ** Scene Compare Image or Scene compare allows you to compare two images/scenes or page synchronized through two scenes e.g. pre and post intervention Copy a single frame Select another frame Select another scene . Compare with a static image @ Siemens Medical Solutions USA, Inc ., 2018 80 Workshop Workbook | Artis One Essentials Notes Image/Scene Compare-Dual Monitor (Biplane) SIEMENS .... Healthineers ... Synchronize Step through both scenes Show corresponding frames Different lengths, framerates, projections are possible Step independently e.g. through two different projections @ siemens Medical Solutions USA, Inc ., 2018 Annotations & Standard Measurements SIEMENS ... Healthineers .... Text Annotations Adjust | Calibr.| Tools Graphical Annotations Distance Measurement Angle Measurement Pointer @ Siemens Medical Solutions USA , Inc. , 2018 Calibration Methods SIEMENS .... neers Healthineers Help Adjust | Calibr. | Tools Maintenance End Session Load Test Image auto auto Auto Expose Confiouredon albration Store Service Image CopyTOWINNE A Service It is important to calibrate before performing measurements. Siemens Medical Solutions USA , Inc . , 2018 81 Workshop Workbook | Artis One Essentials Notes Standard Measurements on TSC SIEMENS . Healthineers Measurements ? X Calibrate image, select measurement type and draw with joystick , Calibration Measurement @ Auto 150 Distance Auto TOO Angle Distance Polyline Curve @ Siemens Medical Solutions USA, Inc ., 2018 Virtual Film Sheet SIEMENS .. Healthineers @ Siemens Medical Solutions USA, Inc ., 2018 General Filming Functions SIEMENS:: Healthineers Copies 4 of DSA Aorta Aneurysn DSA Upper Extemit DSA - John Doe auto @ siemens Medical Solutions USA, Inc ., 2018 82 Workshop Workbook | Artis One Essentials Notes Filming Tab Cards SIEMENS .. Healthineers' ... Layout | Images |Camera Camera Agfa02 Status: Not Ready Film Size Inch 14x17 @ Siemens Medical Solutions USA, Inc ., 2018 Filming Tabcard - Layout SIEMENS . Healthineers Layout | Images |Camera @ Siemens Medical Solutions USA, Inc ., 2018 SIEMENS . Filming Tabcard - Images Healthineers .... Layout |Images |Camera @ Siemens Medical Solutions USA, Inc ., 2018 83 Workshop Workbook | Artis One Essentials Notes Filming Tabcard - Camera SIEMENS . Healthineers Layout | Images | Camera Camera Agfa02 Status: Not Ready Film Size Inch14x17 Siemens Medical Solutions USA, Inc ., 2018 Configurations Filming SIEMENS. Healthineers No Text · penal - Helorenis anags Aspect iluse Orig ed bringe Dar Desule Windows @ Siemens Medical Solutions USA, Inc ., 2018 Configurations Filming SIEMENS . Healthineers *** Dirt Choose under: Configuration of: Filming Layout-General Default-Landscape Customized Text - new entry to select - „Referring Physicians“ Siemens Medical Solutions USA, Inc ., 2018 84 Workshop Workbook | Artis One Essentials Notes SIEMENS Questions Healthineers Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. @ Stemons Medical Solutions USA, Inc ., 2018 85 Workshop Workbook | Artis One Essentials Quantification - Quant Notes SIEMENS Healthineers' ... Artis one Quantification - Quant @ Siemens Medical Measurement Software - Overview SIEMENS Healthineers ... Standard Functions Angulation Distance Selectable in at TSC or System Console Optional Packages on Task Card QVA (Quantitative Vessel Analysis) QCA (Quantitative Coronary Analysis) LVA (Left Ventricle Analysis) IZ3D (3D Coronary Analysis) Include . Angulation Distance @ Siemens Medical Solutions USA, Inc ., 2018 Page 2 Quant validation SIEMENS .... Healthineers .... The QVA algorithm is validated for vessels from 0.5 mm to 50 mm. The QCA algorithm is validated for vessels from 0.5 mm to 7 mm. @ Siemens Medical Solutions USA, Inc ., 2018 Page 3 86 Workshop Workbook | Artis One Essentials Notes Standard Measurements at the Console SIEMENS . Healthineers Adjust Tools Distance Measurement Angle Measurement @ Siemens Medical Solutions USA, Inc ., 2018 Page 4 The Quantification Task Card SIEMENS. Healthineers ... 11.02.21 06 68 12 8TO 11.02 21-06-38:12-STD-4.0.714829 11/18/1050 STUDY DEtrL Car NO cm 17 1240 x 600 IA 885 0 170 RAO 33'/ CRAN 15" @ Siemens Medical Solutions USA, Inc ., 2018 Page 5 Quant Option - Calibration at the Console SIEMENS Healthineers ... Methods Calibrate View Automatic Auto ISO Auto TOD auto auto Manual -- Catheter Distance Sphere -!- Enter a calibration factor Recall Image @ Siemens Medical Solutions USA, Inc ., 2018 Page 6 87 Workshop Workbook | Artis One Essentials Notes Quant Option - Analyzing at the Console SIEMENS Healthineers . QCA 2D Coronary Quantitative Coronary Analysis Analysis QVA nalyzel Adjust | Tools Quantitative Vessel Analysis 2D Vessel Analysis LVA Left Ventricle Analysis Left Ventricle Analysis IZ3D 3D Quantitative Coronary Analysis D Coronary Analysis @ Siemens Medical Solutions USA, Inc ., 2018 Page 7 QCA / QVA - Report SIEMENS .. Healthineers Normal Report · MLD, MLA (Minimum Lumen Diameter, - Area) Reference Diameter & Area % Stenosis Diameter · Area Densitometry Detailed Report . Hemodynamic Data Stenotic Flow Reserve @ siemens Medical Solutions USA, Inc ., 2018 Page 8 Manual Selection of Arterial Segment SIEMENS:: Healthineers ... . Define a center line by multiple clicks · Double click to start computing @ Siemens Medical Solutions USA, Inc ., 2018 Page 9 88 Workshop Workbook | Artis One Essentials Notes Contour Corrections SIEMENS . Healthineers Soft (smaller search region) Hard (no search region) @ Siemens Medical Solutions USA, Inc ., 2018 Page 10 Restriction SIEMENS. Healthineers ... · To exclude a vessel due to vessel detection failure. @ Siemens Medical Solutions USA, Inc ., 2018 Page 11 Contour Results SIEMENS Healthineers ... Length of marked segment Minimum diameter / area Maximum diameter / area Mean diameter / area @ siemens Medical Solutions USA, Inc ., 2018 Page 12 89 Workshop Workbook | Artis One Essentials Notes Automatic Reference - Results SIEMENS . Healthineers' ... ameter MLD Minimum Lumen Diameter .-. 3.37 105 mm 3.02 mm auto . Ref D Reference 1189 mm %MA Cr Diameter D 2604 mmja . Length Stenotic Length ................ 1.05 % MLD % MLA circ CF Calibration Factor @ Siemens Medical Solutions USA, Inc ., 2018 Page 13 Manual Reference - Results SIEMENS . Healthineers 1 or 2 Reference Diameters iameter ................. 3. Configurable MACHE MLA dans . Ref D = Mean Value ! ..................... 1.05 ............ @ Siemens Medical Solutions USA, Inc ., 2018 age 14 User Defined Subsegment - Results SIEMENS . Healthineers 7.71 mm Mn O 2.60 mm 3.36 mm Meen D 2.93 mm CF 0 2504 mm/po . Length-Length between markers Min D Minimum Diameter Max D Maximum Diameter Mean D Mean Diameter between markers CF Calibration Factor @ Siemens Medical Solutions USA, Inc ., 2018 Page 15 90 Workshop Workbook | Artis One Essentials Notes Comparing Results SIEMENS. Healthineers ... Same projection Foreshortening Object in center of image Same heart cycle phase ED preferred Same catheter type Material Size @ Siemens Medical Solutions USA, Inc ., 2018 Page 16 Left Ventricle Analysis - Functions SIEMENS Healthineers .. Contour Detection Automatic . Manual Volume Calculation " Area-Length-Method for monoplane and biplane Simpson Method for monoplane only Wall Motion Models Regional - Radial . Centerline @ Siemens Medical Solutions USA, Inc ., 2018 Pape 17 Left Ventricle Analysis - Prerequisites SIEMENS Healthineers ... Monoplane - RAO 30º Biplane RAO 30º LAO 60º General " Make sure you have filled out „,Height" and „Weight" before you start LVA to get „Index“ values " Fill in „Heart Rate“ on tab card to get values for „Cardiac Output“ @ Siemens Medical Solutions USA, Inc. , 2018 Page 18 91 Workshop Workbook | Artis One Essentials Notes Left Ventricle Analysis - at the Console SIEMENS ... Healthineers ... Use appropriate calibration method Do not use catheter calibration for LVA ! Define Mark aortic valve plane Mark apex Mark corrections on the border, if required Define Mark aortic valve plane Mark apex Mark corrections on the border, if required Select to display the report Select to store the report @ Siemens Medical Solutions USA, Inc ., 2018 Page 19 LVA biplane SIEMENS Healthineers ... Acquire a biplane LV scene Calibrate both planes Plane A Plane B Draw contours in plane B ED ES Draw contours in plane A Click in image plane A Use to select correct images Draw contours for ED and ES Display report, then @ Siemens Medical Solutions USA, Inc ., 2018 Page 20 Auto ED/ES Detection SIEMENS Healthineers ... Auto ED/ES Detection Works only when an ECG has been recorded With a biplane scene, start with plane A as the ECG is only recorded in plane A SW looks for the image with the highest contrast regarding LV area to background Extrasystoles are detected and beat(s) is (are) skipped The first ED/ES is always skipped @ Siemens Medical Solutions USA , Inc. , 2018 Page 21 92 Workshop Workbook | Artis One Essentials Notes Auto ED/ES Detection SIEMENS. Healthineers". After entering the LV analysis SW and all prerequisites are given, an end- diastolic and the appropriate end- systolic frame are selected automatically oft Ventricle Analysis 7x hta | Com The mark ED and mark ES buttons are dimmed If the user wants to check the auto-selection, the user can page through the frames as usual The mark ED and mark ES buttons becomes available again and must be used By pressing the icon again the system returns to the auto-selected ED frame By selecting the "Show ED/Show ES" button the auto- selected ES frame Cancel Help is displayed. @ Siemens Medical Solutions USA, Inc ., 2018 Page 22 LVA - Results SIEMENS. Healthineers .. Volumes for ED (EDV) and ES (ESV) · Ejection Fraction (EF) - Stroke Volume (SV) . Cardiac Output (CO) Indexed values, based on BSA BSA 1,129 Weight Wall thickness / mass / stress BSA = Body Surface Area Siemens Medical Solutions USA, Inc ., 2018 Page 23 SIEMENS . Healthineers . Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. O Siemens Medical Solutions USA, Inc ., 2018 93 Workshop Workbook | Artis One Essentials Archiving and Networking Notes SIEMENS Healthineers Artis one Archiving and Networking @ Siemens Medical Solutions USA, Inc ., 2018 General Transfer Functions SIEMENS ..... Healthineers ... Send to: Transfers images to a predefined or a selected network destination Export to: Transfers images to a predefined CD-R or a selected CD/DVR or OD drive Siemens Medical Solutions USA, Inc ., 2017 Page 2 Manual Transfer SIEMENS . Healthineers ... Select the data Sandro From Browser Dpattr scattom CD_R From Viewer (depending on selected Local Job Status .. Chi+L Directory) Import from Of. ine Espatto Df-Inve .. . Press Transfer key CD A . From Menu bar . From Tool bar . From Keyboard From PostProc/Angio Tabcard Siemens Medical Solutions USA, Inc ., 2017 Page 3 94 Workshop Workbook | Artis One Essentials Notes Importing Data SIEMENS Healthineers' ... Restore from CD/DVD-R Search and Import from Network Required image criteria for reviewing at Artis: · XA objects · 512 x 512 or 1024 x 1024 8 bit, 10 bit or 12 bit images @ Siemens Medical Solutions USA, Inc ., 2017 Page 4 Transfer Job Status SIEMENS Healthineers ... Local Job Status Displays a dialog box with the export / archive or import jobs from/to CD Network Job Status Displays a dialog box with the send / archive or import jobs from/to DICOM nodes Both dialog boxes show Transferred job history All failed transfer jobs @ Siemens Medical Solutions USA, Inc ., 2017 Page 5 What can automatically be transferred? SIEMENS.: Healthineers Alternative Acquisitions Scenes Store Monitors (SM) Store Fluoro Loops Reference Images (REF) Quant Reports (QVA/QCA/LVA) Exam Protocols @ Siemens Medical Solutions USA, Inc ., 2017 Page 6 95 Workshop Workbook | Artis One Essentials Notes What triggers Automatic Transfer ? SIEMENS ..... Healthineers Getting "Completed Flag" by Going off from the footswitch . Storing a SM, Ref, Quant Report Receiving data . Completed Transfer Siemens Medical Solutions USA, Inc ., 2017 Page 7 Where to configure Automatic Transfer SIEMENS .... Healthineers ... Main Menu > Options > Configurations # AXIOM-Artis - Configuration Panel X Elle Patient Browser Screen Saver Transfer ude Trail Filming Study Filming Layout Layout Patient Registratic Patient Search Imagelext Regional and Editor anguage ... Configuration for Audit Trail archiving NUM @ Siemens Medical Solutions USA, Inc ., 2017 Page 8 How to configure Automatic Transfer SIEMENS. Healthineers ... ransfer Configuration Ao-Transin Local Device Network Nodas A |Workstets Processing Status Ogjects DestinationMP Completed Dontcare Imanas CD R C\Serviceimage\Testmages C \Servicelmages ExportToService CIServicemmagas\Cop ToWinNE CINQUANTDICOM CSC-MP CSC-BC CSC-LEOBC Activate transterile 25C-LEOTA Marked images 4c&c.LEOMP Printed images CBC. Archive Ward Completed& Don't cere mages to CK Cancel Detout Siemens Medical Solutions USA, Inc ., 2017 Page 9 96 Workshop Workbook | Artis One Essentials Notes Searching over a network SIEMENS ..... Healthineers ... Bouta FAREvNe @ Siemens Medical Solutions USA, Inc ., 2017 Page 10 Exporting scenes/images SIEMENS Healthineers ... Select Image > Export Image As ... in the main menu of the PostProc task card. Sotros sotoll Videa 1 ades V Page 11 @ siemens Medical Solutions USA, Inc ., 2017 SIEMENS Healthineers ... Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. 9 Siemens Medical Solutions USA, Inc ., 2017 97 Workshop Workbook | Artis One Essentials 3D Imaging Notes SIEMENS Healthineers .. Artis one 3D Imaging O Siemens Medical Solutions USA, Inc ., 2018 3D Acquisition SIEMENS .. Healthineers .. 3D Exam Sets Head . 5sDR Head 5sDSA Head . 5sDR Head Care Body 5sDR Body 5sDSA Body 30 Core . 5sDR Body Care The FICI Cardiac 5sDR Card 5sDR Card Care @ Siemens Medical Solutions USA, Inc ., 2018 . 5SDCT Card Page 2 3D Acquisition OGP Selection - Exam Room SIEMENS.:: Healthineers .. Via TSC (EHC) and onscreen display (OSD) Binglo Single SGOR Card 3 54OR Card Care 56OCT Card ® Carinanin Fininame 9 17 AM NO XRAY - Dose door @ Siemens Medical Solutions USA, Inc ., 2018 Page 3 98 Workshop Workbook | Artis One Essentials Notes Injections and Delays with Dynavision SIEMENS Healthineers ... (4) (1 ) (7) (5) (3) do DSA Protocols DR Protocols .Delays (X-ray) .Fill Time ·DSA Protocols ·DR Protocols @ Siemens Medical Solutions USA, Inc ., 2018 Page 4 3D Acquisition Workflow SIEMENS. Healthineers ... Starting Position . Head side only, in one dedicated longitudinal position . Detector: Zoom 0 (39 cm) - Landscape orientation . Starting angle 100º Set-up for 3D Acquisition Follow the instructions at the display Re-Selection of Previous Acquisition Protocol Within same Exam Set, the previously used Acquisition Protocol will be automatically activated after the 3D run is finished Return to Previous Working Position Siemens Medical Solutions USA , Inc . , 2018 Dependent on setting in Service Mode Pages 3D Acquisition - Return to Working Position SIEMENS. Healthineers ... If 'Return to Working Position after 3D' is enabled The system is in automatic drive mode Use joystick of foot pedal (if configured) to execute C-Arm movement The system will 'Return to Working Position' Stop in angulation used prior to 3D acquisition Select the corresponding FD-Format Restore the collimation and Restore the semitransparent filters accordingly @ Siemens Medical Solutions USA, Inc ., 2018 Page 6 99 Workshop Workbook | Artis One Essentials Notes 3D Display Layout - Exam Room : EHC SIEMENS Healthineers Important Make sure an exam room monitor layout is selected which contains "3D" Layout Gallery @ Siemens Medical Solutions USA, Inc ., 2018 age 7 3D Display Layout - Control Room: SIEMENS Display Layout Selection Healthineers Make sure an exam room monitor layout is selected which contains "3D" BE Siemens Medical Solutions USA, Inc ., 2018 Page 8 3D Review at Table-Side SIEMENS Healthineers ... 3D Review Functions via EHC/OSD Individual entries for VRT and MPR review and processing functions Review C- Review Refine Volume Ftefine Velumt Apoly Clip Piane Ranet All Orientations CAQjust C-Arm Rendering Modes Image forlows C-arm Objects D. Save Image D Save image Joystick tasks Siemens Medical Solutions USA , Inc ., 2018 Page 9 100 Workshop Workbook | Artis One Essentials Notes 3D Review in Control Room SIEMENS Healthineers' 8.4.1 The 3D Viewer task card (3) Image area -(4) (2) Main menu (3) Patient control area (4) Bookmark area -(5) (5) Visualization options (6) Tool card stack -(6) Quick access area (8) Status area with system messages and status icons -( 8 ) @ Siemens Medical Solutions USA , Inc. , 2018 Page 10 3D Review in Control Room SIEMENS Healthineers ... Parallel processing / review of two studies . The C-Arm symbol indicates the Examination Patient Always check the 'open study folder' when astname, Firstname reviewing or loading volumes astname, Firstname @ siemens Medical Solutions USA, Inc ., 2018 Page 11 3D Viewer Control Room Save to File - CD-R Offline Pathway SIEMENS Healthineers ... C/Axiom/temp\CDR_OFFLINE NUM U. Emergency Close Paient Gave for Documentation Interactive Recorr tructica Filming Layout ... Film Tort Status Film Prewew Expose Film Task Save and Copy to Fil Shoot NMPHEnter Fie none Het Siemens Medical Solutions USA, Inc ., 2018 Page 12 101 Workshop Workbook | Artis One Essentials Notes Finding Camtasia Studio on Artis One SIEMENS .... Healthineers ... C Camtasia Recordor Capture View Effects Tools Help Camtasia Studio Screen Window Ragion Eixed Region 10 crdimit- Camtasia Press Record or CTRL + SHIFT+F9 to captur My Computer->Desktop >Camtasia Studio @ Siemens Medical Solutions USA, Inc ., 2018 Page 13 3D Reference Point SIEMENS Healthineers By placing a 3D Reference Point, you can define a 3-dimensional location which will be displayed in all the image segments with the same Frame of Reference. Press the Alt key and click the required position in any image segment. The clicked 3-dimensional location is set as the 3D reference point. All the image segments are panned so that the 3D reference point is displayed in the center of the segment. Siemens Medical Solutions USA, Inc ., 2018 3D Reference Point SIEMENS. Healthineers * -------- @ siemens Medical Solutions USA, Inc ., 2018 Page 15 102 Workshop Workbook | Artis One Essentials Notes Orientation Cube SIEMENS Healthineers ... DEE Auto (InSpace3D) VC 138 000415 Close RAT A (anterior-posterior) P (posten or-anterior) L [left-right) R (right-left) F (rect-hand) H (hood foot) 1380₺ ARO 37 ( CAUD B Right Click on Cube Siemens Medical Solutions USA, Inc ., 2018 Page 16 Measurements --- 3D Polyline SIEMENS Healthineers CA 5 aneurysms VC13B 0804111VB 13E Angio Sub EE Auto [InSpa "8/31/1952 XA 41/30/2000 9:13:48 AM ... ................ RPF :44 mm 5 cm RAD 18 / CRAN 2 Siemens Medical Solutions USA, Inc ., 2018 Page 18 103 Workshop Workbook | Artis One Essentials Notes SIEMENS Artis One Help Healthineers' ... SIEMENS Q introduction ability ------- Technical and condalist knowledge siemens Medical Solutions USA , Inc . , 2018 page 19 3D Review in Control Room SIEMENS Healthineers Blow-up segment . Via double-click in the segment O Siemens Medical Solutions USA, Inc ., 2018 Page 20 3D Review in Control Room SIEMENS Healthineers ... Context menus Dependent on segment content O Siemens Medical Solutions USA, Inc ., 2018 Page 21 104 Workshop Workbook | Artis One Essentials Notes 3D Review in Control Room SIEMENS Healthineers VOI Punching VOI Punching . Mark punching volume in VRT · Double-click to finalize punching By default, 'Remove Inside' is selected Remove Inside Remove Outside Apply to Volume Apply to Segmentation Auto Close Help Siemens Medical Solutions USA , Inc . , 2018 Page 22 3D Review in Control Room SIEMENS Healthineers ... Clip Plane Handling . One clip plane only! Enable Volume Clipping Select orientation Image | Tools |Meas. .. |X-Ray Clip Clip Plane F (feet-he:] O Siemens Medical Solutions USA, Inc ., 2018 Page 23 3D viewer - View & Compare SIEMENS Healthineers .. Www Comesere @ Siemens Medical Solutions USA, Inc ., 2018 ge 24 105 Workshop Workbook | Artis One Essentials Notes 3D Review in Control Room SIEMENS .: Healthineers Role-dependent volume layouts Pay attention to 'data roles' ! Review and Presenting Soprapayout [Show layout se les Review and Processing Link to data-roles appropriate To activate the Review New Layouts, e.g. · 1 VRT + 3 MPRs . 2 VRTs + 3 MPRs . DSA DGA Compare · 3 MPRs NatFill + · VRT DualVolume aSub+NatMask Compare MMMR + VRT Siemens Medical Solutions USA, Inc ., 2018 Volume Opacity Volume Opacity Page 25 Layouts and Data Roles SIEMENS. Healthineers .. Layout Selection Review and Processing Layout Gallery Button (also available table side) Compare MPR 2 Vp MPR + VR Plan Siemens Medical Solutions USA, Inc ., 2018 Page 26 Layouts and Data Roles SIEMENS. Example of Layout Switch Healthineers ... MPR.Sagital MPR.Coronal MPR.Sagital MPR.Sagital Review Review Review Compare MPR.Axial VRT. Default MPR.Axial MPR.Axial Review Review Review Compare NO Siemens Page 27 106 Workshop Workbook | Artis One Essentials Notes 3D Review in Control Room SIEMENS Healthineers Preset Gallery Preset is applied to selected data-role If MPR is selected a to all MPRs . If VRT is selected à to VRT Ruitu Individual presets can be saved and labelled All presets are using auto-window Siemens Medical Solutions USA, Inc ., 2018 Page 28 3D Review in Control Room SIEMENS Healthineers ... Visualization Presets In Artis one, presets contain the following information . Rendering mode · Transfer function . Shading . Windowing Presets may contain data driven information E.g. a preset can contain different transfer functions for XA -, MR- or PET data Not included in Artis one presets . Layout . Orientation . Clipping @ Siemens Medical Solutions USA , Inc ., 201 Page 29 Pre sets on OSD SIEMENS. Healthineers ... Bondow and syngo 3D Bookmarks syngo 30 Layouts syngo 3D Presets AbdominalTransparent Aneurysm\Analysis AVG Windowing Scroll Image siemens Medical Solutions USA, Inc ., 2018 Page 30 107 Workshop Workbook | Artis One Essentials Notes Bookmarks SIEMENS .... Healthineers ... Bookmarks are stored in a separate series [990] Bookmarks @ Siemens Medical Solutions USA, Inc ., 2018 Page 31 3D Review in Control Room SIEMENS Healthineers Bookmarks Loading a bookmark will load the corresponding volume . All postprocessing steps will be restored when loading the bookmark Recommendation: Always save a bookmark before closing the volume O Siemens Medical Solutions USA, Inc ., 2018 Page 32 Bookmarks SIEMENS .: Healthineers. InSpace 3D Viewer Can contain all parameters a preset can . Restore complete visualization behavior contain including e.g. layout, data roles, punching Contained parameter configurable . Reload all data (if possible) . No data reload stored in DICOM database, all bookmarks of a study in one series Can be used as image gallery . Can be used in the exam room by OSD @ Siemens Medical Solutions USA, Inc ., 2018 Page 33 108 Workshop Workbook | Artis One Essentials Notes Bookmarks as image gallery SIEMENS Healthineers' ... . Use bookmarks as "image gallery, Bookmarks from different studies (even different patients) can be loaded into the bookmark gallery 6 Clicking on bookmark data is loaded prior to intervention Load all your needed data as bookmarks and use this as shortcut during intervention --------- Siemens Medical Solutions USA , Inc . , 2018 Page 34 Bookmarks on OSD SIEMENS Healthineers Review and Processing syngo 3D Bookmarks syngo 3D Layouts syngo 3D Presets Windowing Sock Scroll Image Siemens Medical Solutions USA , Inc ., 2018 Page 35 Interactive Reconstruction SIEMENS. Healthineers .. Via Artis One Workplace -- > 3D Viewer -- > Patient -- > Interactive Reconstruction Num VON VO Site PA Panter Height Close @ Siemens Medical Solutions USA, Inc ., 2018 Page 36 109 Workshop Workbook | Artis One Essentials Notes 3D Review in Control Room SIEMENS Healthineers Interactive Reconstruction · Based on "2D" or "3D" activo Hoconstruction Stort interooque se reconstruction, Siemens Healthcare dario Hand Nat Fil Medium . VA108 140122 Job List 12:18:13 PM vol Size: Medium Nun VOI Sice Matrix 512 %512 --- Define vol in O: 2D view Voxel Size 0.21 mm Number of Slices 408 Serien Nome Dyna3D Hoad Rendering Preset DynaJCHead Reconstruction Job - Net Fill Kemeltype HU 10 cm ImageCharacteristics ReconstructionModo LRO RAD 126-/ GRAN 31" Hulp Siemens Medical Solutions USA, Inc ., 2018 Page 37 SIEMENS Healthineers ... Questions Now's our time to inspire the future of healthcare together Engineering success. Pioneering healthcare. @ Siemens Medical Solutions USA, Inc ., 2018 110 Workshop Workbook | Artis One Essentials Day Four [No Powerpoint presentations for this day] Notes 111 Workshop Workbook | Artis One Essentials Notes 112 Workshop Workbook | Artis One Essentials Notes 113 Workshop Workbook | Artis One Essentials Notes 114 Workshop Workbook | Artis One Essentials Notes 115 On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products included in this brochure are available through the Siemens sales organization worldwide. Availability and packaging may vary by country and is subject to change without prior notice. Some/All of the features and products described herein may not be available in the United States. The information in this document contains general technical descriptions of specifications and options as well as standard and optional features which Local Contact Information do not always have to be present in Siemens Medical Solutions USA, Inc. individual cases. 40 Liberty Blvd. Malvern, PA 19355-9998 Siemens reserves the right to modify the USA design, packaging, specifications and Telephone: +1-888-826-9702 options described herein without prior siemens.com/healthcare notice. Please contact your local Siemens sales representative for the most current information. Legal Manufacturer Imaging & Therapy Systems Angiography & Interventional X-ray Note: Any technical data contained in Systems this document may vary within defined Siemensstr. 1 tolerances. Original images always lose DE-91301 Forchheim a certain amount of detail when Germany reproduced. Telephone: +49 9191 18-0 siemens.com/healthcare Siemens Healthcare Headquarters Siemens Healthcare GmbH Healthcare Sector Henkestr. 127 91052 Erlangen Germany Phone: +49 9131 84-0 siemens.com/healthcare Published by Siemens Healthcare GmbH · Order No. HOOD05162002896999 · Printed in USA · © Siemens Healthcare GmbH, 2017 116
- Artis One