ARTIS one Postprocessing
This pdf demonstrates how to use the different postprocessing tools for the Artis one system.
SIEMENS Healthineers Postprocessing Job Aid Artis one VA10 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 07/09/2020 | HOOD05162003102770 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Unrestricted Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Table of Contents Postprocessing task card 3 Postprocessing Onscreen Menu 12 Changing/Correcting Patient Data 13 Rearranging series/scenes/images 15 Patient Search 16 Deletion of Patient Data – Manually 17 Deletion of Patient Data – Automatically 18 Archiving/Export/Transferring Data 19 2 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card – Overview 1 Patient Transfer Edit View Image Options Help IC_ONE_C116_RFO_1 AX R-DIC IL_UNE_CHO_RPU_IS 3 amination 1/1/1940 VA10D 141126 F 1/1/1940 (1) Postprocessing main menu 3/25/2015 Scene 10:31:56 AM 144 DN 3 - 75/89 4.89 sec CARD 15 f's STOP 4 (2) Control area PostProc (3) Patient information area View Image DSA (4) Image review controls Quant (5) Subtask cards R 5 (6) Quick access area Adjust Calib. 3D Viewer Tools 1859 -O 2532 auto 7 (7) Status area with system messages and status icons JV 8 (8) Image area Cardio EE 11% 6 Cardio exLD DDO 50% cm 20 KIPS A D 99 0º / CAUD 30º WC 1859 WW 2532 7 8 2 3 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card 1 Postprocessing main menu When you move your mouse to the top area of the screen, the Postprocessing main menu will be displayed with the following functions: Patient Transfer Edit View Image Options Help Patient Transfer Edit View Transfer Edit View Image Options Help View Image Options Image Options Help Options Help Help Exam Protocol Send to ... Zoom Maintenance. Contents and Index ... Close Patient Export to ... Acquisition Size Invert Gray Scale Num 0 Native End Session Register .. About Artis one ... Emergency ... Eject from DVD_R Shutter Max Fill Override Configuration Message History Browser ... A Annotation Change Vessel / Catheter Contrast Num . Eject from ... Set Replace Mask Auto Expose Filming Layout ... Finalize Medium and Eject from DVD_R Image Text CLEARstent Scene Timer Film Task Status ... Local Job Status .. Ctrl+L ECG Display Flip Horizontally Load Test Images Film Preview ... Network Job Status ... Ctrl+N Flip Vertically Store Service Image Expose Film Task Ctrl+P Copy to Film Sheet Import from Off-line. Loop All Scenes Select All Copy To WinNIEA Review Mode. Export to Off-line ... Service Search Record Off-line Files Export Image As ... Search Selected. Screenshot to USB Send To 3D ... 4 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card Default review mode: * 1. In the Postprocessing main menu, select View > Review Mode. A dialog box opens with the available review modes. View Image Options Help Default Review Mode X 2. Select the required review mode for the available acquisition modes. Zoom Acquisition Size Unstored 3. Fluoro / RDMP Loop Confirm your selection by clicking Close. Shutter Stored Fluoro / RDMP Loop Review modes for fluoroscopy/roadmap: Annotation CARD Loop Image Text ¥ Scene Timer DR/DSA Loop • LIH (Last Image Hold): The last fluoroscopic/roadmap image frame is displayed. v ECG Display PERI Loop: A Fluoroscopy scene is replayed continuously from first to last image Loop • Loop All Scenes 3D MFH frame. Review modes for acquisitions: Review Mode ... Hide Patient Information Close Help .................................................... • MFH = Max. Fill Hold: Once a scene has been loaded, the maximum fill image is displayed immediately. Loop: An acquisition is replayed continuously. *Default Review Mode requires the Fluoro Loop license for • • Toggle: The scene is played continuously but, unlike Loop, the review direction changing the Review modes for Fluoro/Rdmp. is reversed after the last image frame (ping-pong effect). 5 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card 4 Image review controls Scene Scene directory: Opens an overview Scene display of the stored scenes/images/ Scene Filter the scene directory: Ref. Image Store Monitor Scene: only scenes (multiframes and single DSA 4 f/s STOP reference images depending on the + Ref. Image + Store Monitor acquisitions): acquisitions and stored fluoro, current filter selection. SM + Ref. Image roadmaps. 144 Scene - / Scene + Ref. Image: only reference images Ref - / Ref + Store Monitor: only secondarily stored images + Ref. Image: scenes and reference images DR 10 f/s 10 f/s Changing the review frame rate + Store Monitor: scenes and stored images (no 41 reference images) SM + Ref. Image: stored images and reference Starting/stopping the loop images DR 10 f/s Of/s Single step: A looping scene can be stopped and then reviewed frame by frame forward or backward. 6 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card 5 Subtask cards View Image DSA View Image Options Full-screen Select All Annotation and Measurements Zoom Delete Selected Annotation and Measurements Acquisition Size Invert Scene Overview Shutter Native Flip Horizontally Annotation Flip Vertically Image Text Shutter Scene Timer Zoom v ECG Display Shutter View subtask card Loop All Scenes Annotation Invert Gray Scale Review Mode. Image Text Curved Distance Measurement Main menu Scene Timer Zooming/Panning ECG Display Context menu Zoom to Acquisition Size Looping through All Scenes 7 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card 5 Subtask cards View Image DSA CLEARstent * Image Options Help Select All Annotation and Measurements Invert Gray Scale Delete Selected Annotation and Measurements R Flip Horizontally Native R | A Invert Max Fill Override Native 0 |0 Change Vessel / Catheter Contrast Flip Horizontally RIA Flip Vertically CLEARstent Flip Vertically opac Flip Horizontally Zoom Image subtask card Opacification Flip Vertically Shutter opac Select All Annotation Export Image As ... Image Text Curved Distance Measurement Send To 3D ... Scene Timer v ECG Display Main menu Context menu * CLEARstent is an option 8 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card 5 Subtask cards View Image DSA + Move Mask Averaging Mask/ Fill Image MI + Native/Subtracted Zooming/Panning MI Anatomical Background Zoom to Acquisition Size opac optional DSA subtask card* Pixelshift Opacification opac Invert Gray Scale 9 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card 5 Subtask cards Adjust| Calib. Tools 2100 Windowing Adjust Calib. Tools Auto ISO Calibration: Isocenter 1695 2250 Set “brightness” and “contrast” calibration is automatically auto 2400 preselected by the system for auto auto auto image angle 50° ... 130°. Auto Window auto --- Auto TOD Calibration: TOD calibration is automatically auto preselected by the system for M 20 Window Home image angle 0° ... 50° or 130° ... 180°. Adjust Subtask card -!- Manual Distance Calibration: M 21 Edge Enhancement Calibration Subtask card Once the distance line has been drawn by moving and marking with the mouse pointer, the Edge Enhancement Home length of the distance line is entered and calibration is applied. 10 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing task card 5 Subtask cards Adjust Calibr. Tools XYZ Annotation: Enter text .......................................... in the image Drawing Line ................... XYZ Drawing Circle Pointer: point out certain image details on the screen Drawing Polygon Distance: The distance between two points of a straight distance line or along a curve Tools subtask card Hide Annotations and Angle: Angle measurement by drawing two lines Measurements Drawing Arrow 11 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Postprocessing Onscreen Menu Postprocessing Onscreen Menu contains the functions depending on the Onscreen Menu configuration. General Native Sensis MPR VRT General DSA VRT MPR Workflow General Native Review Review Zoom by Factor 2 LP Display Scene Native Store Monitor - Adjust Windowing D" Anatomical Background O Annotation Text ... D. Move Mask a_ Store Reference Annotation ... Circle )e Opacification O Layout Gallery Distance Measurements D' Auto Pixelshift O Hide Annotations 0 % Pixelshift Home 0 D. Close Patient Delete Annotations Zoom by Factor 2 General menu Native menu: The Native menu contains DSA menu (optional): The DSA menu functions for manipulations of scenes that contains functions for manipulations of were acquired non-subtracted.* scenes that were acquired subtracted.* *Depending on the image type loaded the system automatically provides either the Native or the DSA menu (optional function). 12 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Changing/Correcting Patient Data 1. Select Edit > Correct in the main menu of the Postprocessing task card. 2. Select Edit > Correct in the menu of the Patient or – Browser. – Press the Patient Browser (Num .) key on the symbol keypad. @ Patient Browser Patient Transfer Edit View Filter Sort Private Applications Optio EEL + The Patient Browser window opens. Select the patient requiring modification. It is not possible to correct or rearrange patient Corrections depend on the selected level in the Patient Browser: Patient - data in the following cases: Study - Series – Instance. Studies which include only one scene should be ➢ Specific data of special objects, for example: corrected on the Instance level. Only data that refers to the selected level can patient position in the Exam Protocol SR be modified. To modify the name of the series (scene name), for example, the ➢ Protected data Series level must be selected. ➢ Data of HIS/RIS patients ➢ Data of the current examination patient during radiation ➢ Data on external media 13 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Changing/Correcting Patient Data 3. The Correct window opens. Click 4. To correct the Patient position 5. After correcting the patient data, enter the Patient subtask card and enter click the Series subtask card and your name under Modifier's name or the correct patient data. If Select the correct position from select your name from the selection list necessary, change other data. the drop-down list. and click OK. Modifier's name meduser Modified's hume meduser Modifier's nume meduser Lest nome 34 03 13-02 55 11.STO Fust name Last riemer 24 05 13-02: 55 11 ST Fust name Lest rome 34 05 13-02:55 11 STL Fust name Paoent D 14.03.13-02 55:11 STD 81993 Middle farm Patient [ 14.03.13-02 55:11 STD 81993 Middle fiamm Paoun D 14.03.13-02 55:11 STD 81993 Middle fiamme Patient Patient Sumx Sumx Sumx Referring physicien Other patients name(s) Referring physicien Other patients name(s) Other patients name(s) Other patient D(s) Other patient D(s) Referring physicien Admission D Other patient D(s) Ethnic group Ethnic group Ethnic group Matary rank Matary rank Matary rank Date of birth 1/1/1900 Date of birth 1/1/1900 Date of birth 1/1/1900 Accession No Female Female Female Weight Weight Weight Serve descaption Address Serve descoption Address Serve descoption Address Addooralinto Addoonal into Addoorial into Comment Comment Commen OK Cancel Holo OK Cancal Holo OK Cancal Hop 14 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Rearrange series/scenes/images 1. Call up the Patient Browser by pressing the Patient Browser (Num .) key on the symbol keypad. 2. Select the series/scenes (images). 3. Drag and drop: Drag the selected data to the target position and release the mouse button. Rearrange X -or- "14.03.13-02:55: 11-STD" on "Local" Cut and paste: Click this icon or call up Edit > Cut in the menu of the Patient Browser. 1 Study, 24 Series (total 23 Images, 0 NonImages, 0 Waveforms, 0 RT Objects, 1 Report/Result Object, 0 new 4. Click the target position. DICOM Objects, 0 RawData, 0 SurfaceSegmentation(s). 0 Encapsulated Document PDFs) will be moved to 5. Click this icon or call up Edit > Paste in the menu of the Patient Browser. Patient 14.03.13-05:20:36-STD 6. The Rearrange dialog box will be displayed. Modifier's name meduser 7. Enter your name under Modifier's name or select your name from the selection list. 8. Confirm by clicking OK. OK Cancel Help Rearrange is not possible in the following cases: • Rearranging to the wrong data level • Rearranging scenes/images to a series acquired with another patient position • If images were acquired on a different modality (e.g. CT) 15 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Patient Search Patient Search X Using the Patient Search, you can query and retrieve patient and Basic Search Patient Name From To Node examination data from workstations and long-term archives that work with Patient ID Study Date Artis_Qceiling Date of Birth Study Time Artis_QzenBP SENSIS Hemo other DICOM program systems. Sex Any Accession Number XWP Qbiplane XWP Oceiling Modality 1. Click this icon in the toolbar. Advanced Search Study Description From To or – Study ID PPS Start Date – Referring Physician PPS Start Time Select Patient > Search... in the menu of the Patient Reporting Physician Body Part Exam Study Instance UID Performing Physician Browser. The Patient Search window opens. Series Instance UID Request Procedure ID Series Number Scheduled Procedure ID 2. Enter your search criteria and click Search. Series Description Approval Status Reporting Search Search Clear Type New Query Name Save Delete If you want to search for an existing patient in the Local Database folder in the network: Import Import Job Status Image List Discard search results on close Close Help • Select a patient in the Patient Browser. Ready • Select Patient > Search Selected... in the menu of the Patient Browser. The Patient Search window is displayed. • Enter your search criteria and click Search. 16 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Deleting patient data – Manually 1. Call up the Patient Browser by pressing the Patient Browser (Num .) key on the symbol keypad. + ES 2. Select the objects via single LMB click to be deleted. 3. Select Edit > Delete in the menu of the Patient Browser or open the context menu (right mouse button) and select Delete there. or – – Click this icon in the toolbar. A dialog box appears in which you must confirm that you really want to delete the data you have selected. 4. Confirm the question with Yes to delete the selected patient and examination data. 17 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Deleting patient data – Automatically AutoDelete Configuration X 1. Select Options > Configuration... in the main menu. Local RawData Recycle Bin Double-click the Auto Delete icon The Auto Delete Configuration window Automatic deletion is performed at following timepoints for following data 2. . i Deletion can also be started manually via the menu (Edit > Auto Delete) opens. Do not permanently delete data. Move data to recyclebin • Select whether the Recycle Bin should be used or not: click the Do not permanently delete data. Move data to the recycle bin check box to change the setting. Timepoints for deletion 3. Select the database (Local Database or Recycle Bin) for which automatic deletion shall If database fillstate has reached 80 % or be configured: 08:00 Monthly 4. Define the Timepoints for deletion. 6 Day of every month(s) • Select the options to be used. o The Sunday of every month(s) 5. Define the Data to be deleted. Data to be deleted Delete all series with following flags • Select the rules to be used. Archived [ Archived + Committed 6. Define Ask confirmation before deletion. Sent Sent + Committed • If this option is selected, users are prompted to confirm whether data should be or Delete all studies which are older than 14 day(s) deleted when Auto Delete starts. Ask confirmation before deletion 7. Click OK to make the settings take effect. OK Cancel Help 18 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Archiving/Exporting/Transferring Data Archive To and Send To 1. Setting a directory filter 2. Displaying the scene directory 3. Archiving/Sending In the Postprocessing task In the PostProc or Quant task card, click the Scene Click this icon in the Patient Browser. card select the required Directory icon. 8888 display from the drop- The system switches to 4 x 4 display mode and displays the down menu. representative image of each stored scene. or – – Scene To select all objects: Select Transfer > Send To... or - + Select Image > Select All in the main menu. Transfer > Archive To... in the main Scene or – – menu. Scene Ref. Image Press Ctrl + A. Store Monitor You will see this icon + Ref. Image To select the required scenes/images: + Store Monitor at the bottom of the control area. SM + Ref. Image Select one of the required images. Press the Ctrl key and All Data is being sent. select the additional scenes/images. 19 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Archiving/Exporting/Transferring Data Exporting to CD-R/DVD 1. Insert an (empty) CD-R/DVD into the writer. The first time you export data to a new medium, the Enter Label dialog box is displayed. Enter a unique name for the medium. 2. Click this icon in the Patient Browser. or – – Select Transfer > Export To... in the main menu. A dialog box with the available archiving destinations opens. 3. Select one or more destinations and click Export/Archive. The image data will be archived at the selected destinations. 20 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Image Documentation/Archiving Transfer Configuration Automatic Sending/Transfer Configuration: Auto-Transfer Local Devices You can configure destinations for sending and exporting and setup automatic A Workstate Processing Status Objects Destination MP Completed Don't care New mages sending/exporting. Automatic sending should only be set for syngo products. To open Delete the automatic sending/ transfer configuration panel: 1. Select Options > Configuration... in the main menu. 2. Double-click the Transfer Configuration button. Transfer 3. Press New to create a new transfer rule. Activate transfer rule Marked images only Printed images only 4. After creating, select Active transfer rule to activate your transfer rule Completed Don't care Images to Images 5. Always select Don't care in the second drop-down menu, otherwise transfer rules None None Don't care Don't care Non Images Completed Archived Reports Read Archived & Committed Series will not work and click OK. Archived & Verified Studies Verified Received Waveforms Sent Sent & Committed Structure Set Printed RT Plan Exported OK Cancel Default Help • An auto transfer rule consisting of Don't care + Received + Series or Studies will not result in an auto transfer. Set Don't care + Received + Images as an auto transfer rule! Most cardiac networks and viewing stations only permit processing/viewing with 512²/8-bit image display! • 21 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Archiving/Exporting/Transferring Data Exporting scenes/images Export Image AS ... ? X Format 1. Select Image > Export Image As... in the main menu of the PostProc task card. Format Type AVI Type AVI The Export Image As window appears. AVI Range Bitmap From 33 To 44 Select All 2. Select the desired format from the Type selection list. JPEG Settings 3. Select the range (if applicable). Full Frames (Uncompressed) Change Image Options Help Output Size: 1024 × 1024 Plane: A+B 4. Select planes (if applicable). Invert Gray Scale Include: M Text M Graphics DECO 5. Set the image matrix. Native Path And File Name Max Fill Override HACDR_OFFLINE 6. Include or do not include text/graphics/ECG. ICStent AX_Angio_(S3_11_F33-44)A.avi 7. Define the file for the data. The export location is set automatically when the AX_Angio_(S3_12_F33-44)B.avi Flip Horizontally USB device is plugged in. Flip Vertically Export Progress: 8. Start the export by clicking OK. Export Image As ... Record Off-line Files Scenes/images can be exported in a common format to a directory on an Send To 3D ... OK Cancel Help external USB device. The following image formats are supported: • AVI format (*.avi) Various video compression codecs are supported. • Windows Bitmap (*.bmp) • JPEG format (*.jpg) 22 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Postprocessing – SIEMENS Healthineers Archiving/Exporting/Transferring Data 1 Eabort Transior EG view Image oroons END IC ONE C116_RF5_15 AX R-D IC 3 amination EAS 1/1/1940 VA10D 141126 F 1/1/1940 Exporting image data to the external USB device 3/25/2015 HFS Scene 10:31:56 AM 3 - 75/89 4.89 sec CARD 15 1/s STOP 4 PostProc • Plug the USB device into the USB jack. • Wait a moment (until the LED on the drive stops blinking). View | Image | DSA Quant Removing the USB device R 5 Adjust | Calib Tools 3D View 7 1859 • Single-click the LMB on this icon in the Status area 2532 auto . • Left-click Safety Eject PNP Device to remove your external USB device safely. Cardio 6 Cardio exLD DDO 50% • The USB device can be unplugged following the status message PNP cm 20 A device can be unplugged in the Status area 7 D 99 0º / CAUD 30 WC 1959 WW 2532 . 8 2 If you remove the USB device without deactivating it via the software, this may result in loss of data, damage to the operating system and damage to media. Do not immediately unplug a USB device. - PNP Device Mounted - Drive(F:): Tot ... Always use the software functionality for safe removal before unplugging. - 23 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 www.siemens-healthineers.com 24 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019
- ARTIS one