ARTIS one Safety
This pdf introduces you to the safety components of ARTIS one system.
SIEMENS Healthineers Safety Job Aid Artis one VA10 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 07/09/2020 | HOOD05162003102770 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Unrestricted Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Table of Contents Emergency STOP buttons 3 Warning Signs 4 Danger Points 5 Power Failure – Rescuing the Patient 6 Defect Footswitch 7 Reset Unit Computer/Collision Override 8 Brake Test 9 2 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Emergency STOP buttons In case of danger, press one of the red emergency STOP buttons immediately to shut down all system drives and stop unit movements and radiation. By pressing the footswitch you can release radiation again right away. In the following cases you should press the emergency STOP button: 144 • If a malfunction of the system occurs. • If a unit movement causes an emergency situation involving danger to the patient, to operating personnel, or to the unit. • If unwanted radiation occurs, for example if a radiation release pedal jams or it is blocked by a radiation protection lead rubber skirt. STOP Canceling STOP: STOP • Only when you can identify the cause of the danger unequivocally and remedy it you can then disengage the emergency STOP button. To do On the front sides of the Artis one stand control module and table control module. so, pull the red emergency STOP button. Movements are possible again. 3 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Warning Signs Danger of crushing for the patient and/or operator. Maximum patient table load + kg (patient load + accessory load - without CPR load) Maximum patient table load, without accessory load and without CPR load. (CPR = cardiopulmonary resuscitation) CPR position: This warning label indicates the position of the tabletop for CPR. To achieve maximum stability for a cardiac massage (CPR = cardiopulmonary resuscitation), the tabletop must be moved so that it is directly above its supporting table column. 4 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Danger Points Danger points on the floor stand Danger of crushing: • At the pivot bearing of the C-arm during rotations • At the friction bearing of the C-arm during orbital movements • On the rails of the FD slide for FD lift Danger of collision: • At the outer edges of the C-arm • At the top of the FD lift Danger points on the patient table Danger of crushing: • Between the tabletop and the table column • Between the tabletop and the accessory rails Danger of collision: - • On the outer edges of the table and on the accessory rails - 5 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Power Failure – Rescuing the Patient In the case of power failure, motorized system movements are not available, but you can move parts of the system manually to rescue the patient in case of danger: • Manual stand movement 1. First unlock the floor stand by pressing the unlocking pushbutton 1 (located on the rear side of the floor stand). 2. Swivel the stand by applying sufficient force 2 . 2 • Rotating the patient table 1. Press the table unlocking pedal 3 . (3) 3 2. Keep pressing the pedal and rotate the patient table. 1 3. Release the pedal. 4. Rotate the patient table back and forth slightly until you hear it engage. 6 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Defect Footswitch If fluoroscopy is not possible by pressing the respective footswitch, you can also release fluoroscopy by pressing the handswitch acquisition release button. Control room, Examination task card: 1. Select Acquisition > Activate Fluoro on Handswitch in the main menu. 2. A confirmation dialog opens. Click Yes. Patient Activate Fluoro on Handswitch Acquisition Options Help 13.10 Exam Set Editor 13.10 Change of handswitch mode is only permitted , if fluoro release is not possible due to a footswitch failure. * 1/1 Change Password Reset Password Please inform Customer Service about this problem. O Set Anatomical Background On activation: -Fluoro release will be restricted to handswitch only STUDI Head Holder Mounted -Acquistion will not be available via handswitch anymore 10/4 1:28:33 PM Activate Fluoro on Handswitch The handswitch will be automatically reset to acquisition mode after shutdown of the system Do you really want to activate fluoro on handswitch? Yes No Only activate if the fluoroscopy release pedal on the footswitch does not work. 7 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Reset Unit Computer/Collision Override Stand Control Unit Reset O If no unit movement is possible, even if emergency STOP buttons, collision protection sensors and STOP block movement have been checked, you can reset the unit computer: 1. Simultaneously press and hold the Store position and Set zero stop buttons and also push the emergency STOP button on the stand/C-arm control module. Wait until the bypass screen appears on the exam room monitor. 2. Then pull the emergency STOP button and after that release the Store position and Set zero stop buttons. Collision Override WARNING If a collision has occurred and the collision sensor has responded: When the safety override is 1. You can initiate a movement by pressing and holding the Store active, executing unit position and Set zero stop buttons simultaneously. The message movements can result in a higher collision risk involving Collision control deactivated appears. mechanical damage or 2. Deflect the operating element in one of the possible directions. personal injury. 8 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Safety – SIEMENS Healthineers Brake Test The Artis one system requests a brake test regularly. The brake test must be performed in the Parking position. 1. Click the System Positions button on the Stand Control Module and select Parking Position. 2. Press down the Stand Control joystick on the Stand Control Module and deflect it forward until 144 the Parking position has been reached. The system drives to the Parking position. The message Stand Test: Activate stand movement # s is displayed. D 3. Press down the Stand Control joystick and deflect it forward again. The brake test is started and SCM - System Positions button the message Stand Test: running is displayed. 4. The system performs the brake test for each axle (6 times). 5. Continue pressing down and deflecting the joystick until the message Stand Test: Successfully completed is displayed. Normal movements are possible again. If the brake test is not successful, the message Automatic Stand Test failed, SC is displayed. All movements of the stand are (144 blocked. (Table movements are still possible.) In this case please call Siemens Healthineers Service. SCM - Stand Control Joystick Please note: You can interrupt the brake test at any time by releasing the Stand Control joystick. The message Stand Test: Will be aborted in # s is displayed. 9 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 www.siemens-healthineers.com 10 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019
- ARTIS one
- safety