ARTIS one System Operation
This pdf demonstrates how to perform the daily system operations tasks at the Artis one system.
SIEMENS Healthineers System Operation Job Aid Artis one VA10 Version 2019.07 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 Unrestricted System Operation – SIEMENS Healthineers Table of Contents Switching on/off 3 System Restart 4 Control Modules – Overview 5 Control Modules – Table Control Module (TCM) 6 Control Modules – Stand Control Module (SCM) 8 Control Modules – Collimator Control Module (CCM) 11 Control Modules – Table-Side Control Module (CCM) 12 Onscreen Menu 14 Layout Gallery 15 Layout Gallery – Display Layout Configurator 16 System and Anatomical Positions 18 2 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Switching on/off Switching the system on: Switching the system off: You switch the system on by pressing the power-on button 1 • Select Options > End Session... in the main menu. on the system console. Keep the power-on button pressed • The End Session dialog box is displayed. for more than 0.5 s. • Click Shutdown System... and click Yes. Please ensure that the on-site main switch is switched on and the emergency Shutdown button is inactive. Options | Help End Session X SIEMENS (1) Power-on button 1 Maintenance. 3 End Session ... Log Off. 0 1 (2) USB drive 2 Configuration ... Shutdown System. (3) CD/DVD drive 3 Set Replace Mask Auto Expose Restart System. Load Test Images Restart Application ... Store Service Image --- Copy To WinNIEA Standby ... --- -www Service Cancel Help 3 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers System Restart When a problem with the imaging system occurs, it may be necessary to restart the imaging system (Restart Application) or the entire Artis one system (Restart System). If a message ... Restart imaging system appears, you must terminate the imaging system application and then restart it. Restart application 1. Select Options > End Session... in the main menu. The End Session dialog box is displayed. Options Help End Session X Maintenance. 2. Click Restart Application... Another dialog box appears. End Session ... Log Off ... 3. Click Yes. Configuration ... Shutdown System ... The imaging system is terminated and restarted. Set Replace Mask Auto Expose Restart System ... Load Test Images Restart Application ... -- - --- Restart system Store Service Image Standby ... - -- - --- www Copy To WinNIEA 1. Select Options > End Session... in the main menu. The End Service Cancel Help Session dialog box is displayed. 2. Click Restart System... Another dialog box appears. 3. Click Yes. The entire system is shut down and restarted. 4 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Overview System control modules allows you to operate the stand, the patient table and the imaging system. 11 K4 - # K4 1 2 3 4 1 Table Control Module (TCM) 2 Stand Control Module (SCM) 3 Collimator Control Module (CCM) 4 Table-Side Control (TSC) 5 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Table Control Module (TCM) Table panning knob: Adjust the tabletop position. 1 Perform table lift Set isocenter: LED is on or flashes if active. O Lock tabletop movement: LED is on if active. = Lock lateral tabletop movement: LED is on if active. 6 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Table Control Module (TCM) Table rotation • Table rotation is performed manually. • Table rotation is only possible via the pedal, mounted on the base of the table column. • The table locks every 3°. Rotating the patient table: 1. 1 Press the table unlocking pedal. Keep pressing the pedal and 2 rotate the patient table. 2. 2 Release the pedal. Rotate the patient table back and forth slightly until you hear it engage. 7 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Stand Control Module (SCM) With the Stand/C-arm multifunction joystick the stand and C- arm positions can be adjusted by deflecting the joystick in the required direction: 0 (1) Dead man's switch enables movements by pressing down. 2 2 0 (2) Buttons on the left and the right side enables switching over 2 3 from C-arm angulation to stand swivel or C-arm longitudinal movement. (3) Rocker switch on the back enables lifting and lowering the 3 Flat Detector (setting the SID). 8 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Stand Control Module (SCM) O O Anatomical positions Angulations or linear movements System positions O 0+ O Store position Set zero stop Orientation key Direct positions I Direct positions II Direct positions III 9 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Stand Control Module (SCM) O Orientation key: The orientation key causes movements to be made in the same direction as the joystick of the respective O control console is deflected. By pressing the key for more than 3s you can change the orientation of the control console. The illuminated LED indicates the active position. Assignment of the illuminated LEDs to the current position of the control console with respect to the patient table: Control console to the right of the tabletop (default position) O Control console at the foot end of the tabletop O Control console to the left of the tabletop O O Control console at the head end of the tabletop O 10 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Collimator Control Module (CCM) The upper joystick controls the wedge filter. The lower joystick controls rectangular diaphragm. # # # The Reset collimator leaves and filters diaphragms. # . Collimator/FD rotation (Multispace) - + + Change image input format/zoom stage 11 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Table-Side Control Module (TSC) Imaging system Table-Side Control Module (TSC): With the Table-Side Control Module (TSC), the imaging system can be operated in the examination room. Mouse Joystick Middle button: Display of the mouse joystick functions on the screen in exam room: • Store a 2D reference image when assigned to 2D postprocessing • Windowing button when assigned to 3D postprocessing Possible directions of joystick deflection Left button: Right button: Joystick function without button pressed Navigate Select and Finish steps or manipulate objects. exit functions. Joystick function with a button pressed Select Close Top view Block Radiation Block Movement Front view 12 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Control Modules – Table-Side Control Module (TSC) Factory default button configuration SM K 000 0000 0000 REF REF K Store the current image Scroll to previous and Scene directory Postprocessing (Store monitor) next reference image onscreen menu K K Store fluoroscopy image Scroll to previous and Dilatation timer Layout Gallery next scene REF Store reference image Increase and decrease Examination fluoroscopy pulse rate onscreen menu Please note: This area can be configured. Please contact your Siemens Healthineers Customer Service for further information. 13 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Onscreen Menu When you press one of these keys on the Table Side Control (TSC) To navigate within the onscreen menu deflect the mouse module, the corresponding menu will appear on the display in joystick. the examination room. Examination • Move left/right for navigating between pages. onscreen menu Roadmap Overlay Ref Series Description ... Exam Set Dilatation Timer 0 • Move up/down for navigating between items. Postprocessing onscreen menu General Native Store Monitor Store Reference • To select an item of the onscreen menu press the left mouse Layout Gallery O, Close Patient joystick button. Layout Gallery Display Layouts • To close the onscreen menu press the menu key again. Layout 1 Layout 2 Layout 3 Layout 4 Layout 5 syngo 30 Layouts - Review or – – syngo 30 Layouts - Compare syngo 30 Volume Presets Press the right mouse joystick button. (Within a submenu, only the submenu is closed.) 14 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Layout Gallery Examination room, onscreen menu (if configured): Display Layouts • To select a layout press the Layout Gallery key on the TSC. or – – Select Layout Gallery in the General menu. Layout 1 Layout 2 Layout 3 Layout 4 Layout 5 • Deflect the mouse joystick to select a layout. syngo 30 Layouts - Review • Press the left button of the mouse joystick to activate the layout. syngo 3D Layouts - Compare syngo 3D Volume Presets Exam Room Display Layout Selection Control room, Examination task card: Assist Live Assist Live Live Sensis Hemo Live IVUS / US Click the icon Info • ensis Her . Info live - Assist large Live Live - Sensis Hemo Live - IVUS • Select the layout to use and click Apply. Live 3D Live Live Assist Card App Sensis EP Card App Live Assist IVUS / U 3D Into Into ive - 3D Live - Mapping Into Info Live - Sensis EP 1 - 4 LIVE Card App Info Test_EP Cancel Help 15 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Layout Gallery – Display Layout Configurator Control room, Examination task card: ER EAS - Configuration Panel X File × The Display Layout Configurator lets you configure the screen layout on the + display in the examination room. You can customize the screen layout to your 3D Auto Delete Patient Close Patient Add Printer Transfer Reconstr. Browser Assistant needs and to your examination practice. Audit Trail Filming Study Filming Filming Patient Patient 1. Select Options > Configuration in the main menu on the system console. Layout Layout Layout Editor Registration Search 2. Double-click the Display Layout Configurator icon to open the Display Layout Configurator. Software Date and Image Text Display Regional and Organize Distribution Time Editor Layout Language ... Stored Pos. Configurator Note: Display Layout Configurator NUM • A default layout is mandatory and can be changed, but must contain a Live image segment. • If there is a Live image segment, it is always positioned in the top left corner. • The Info segment is mandatory. • A vertical Info segment on the left side is not allowed. 16 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers Layout Gallery – Display Layout Configurator 1 Menu bar: New Layout, Duplicate Layout, Save, Undo/Redo. 1 splay Layout Configurator X New Duplicate Delete Layout Layout Layout Save Import/Export Configuration Configure 2 Sources Layouts: By clicking the arrow icon displayed to the left of the layout name, 2 Layouts 5 Sources the default layout can be defined for system startup, for 01. Live Assist 3 3D CLEARstent Live, and during X-ray. If a layout has been defined as a * Info Live - Assist default, it is marked by a star. * 02. Assist Live Assist Live Live 3 Info Layout build-up area: You can drag and drop image segments Sensis Hen large Live from the Source to the layout build-up area and select, move, resize or 03 Live Sensis Hemo delete them. Assist Info Info 4 Segment Properties: The size and position of the selected image segment Live - Sensis Hemo 04. Live IVUS / US are displayed and can be changed in this area. Info Info 5 Sources: The sources which have been configured are displayed. Live - IVUS 05 Segment Properties Live Segment Size Sensis EP Lock Ratic Segment Position LOCK Please note: Only the first 12 layouts can be selected/activated in the Info 1278 Live - 3D Height Scaling height 99.8% * X Width 1278 + Scaling width 99.8% Y 0 + 06. examination room. The remaining layouts are only displayed in the Display Live Sonsis EP 4 Sensis Hemo Layout Configurator. 17 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers System and Anatomical Positions System/Anatomical Positions Assist System Positions 1. Press the required position icon on the Stand Control Module: Patient Transfer Preview ▪ System Positions: A set of basic positions of the stand and table are saved as Head Side Left Side special system positions. The stand position is related to room coordinates. Right Side, Table Rotated 34. -32am O Page Anatomical Positions (Programmed positions): You can save a number of OR Position ▪ 4 1/3 Peri Position positions, that you require for examinations. The C-arm will be positioned Parking Position Automap related to the patient position. 2. The corresponding menu appears on the Onscreen Menu and the LED on the key lights up. ASSIST Anatomical Positions 3. Select the required target position by deflecting the stand/C-arm joystick backward or Preview forward repeatedly. 4. Confirm the target position by pressing one (or both) side buttons. ................................ 5. Press the stand/C-arm joystick down and deflect it away from you until the target Page 1 1/5 ................ position has been reached. ................ 6. The LED on the program key goes out. 7. The system returns to its original state. 18 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers System and Anatomical Positions Store programmed positions 1. Move the unit and the table height to the required position (configurable by Siemens Healthineers Service). 2. Set the SID, zoom stage, primary collimator and filter diaphragms. 3. Press the Store key from the Stand/C-arm Control module The LED on the key lights up. . 4. Select the required memory position (number) by deflecting the Stand/C-arm joystick backward or forward repeatedly. 5. Press one or both buttons on the side of the Stand/C-arm joystick to store the current system position under the selected program number. (The previous position is deleted.) or – – Press the required position key to store the three most frequently used system positions with shortcuts +0- (direct positions I, II, III). These saved system positions with shortcuts are not listed in the system positions and are not saved in the system position list. 6. The LED on the store key goes out and the system returns to its original state. 19 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 System Operation – SIEMENS Healthineers System and Anatomical Positions Organize/edit stored positions EAS - Configuration Panel X File 1. Select Options > Configuration... in the main menu. 30- Auto Delete Patien Close Patient Add Printer Transfer Browser 2. Double-click the Organize Stored Positions icon. A list of the stored positions and a preview of Reconstr. Assistant 2 the selected position will open. Positions may be marked by a: Audit Trail Filming Study Filming Filming Patient Patient Layout Layout Layout Editor Registration Search . L. • Factory position (cannot be edited) v Software Date and Image | ext Display Regional and Organize • Protected position (cannot be deleted or overwritten) Distribution Time Editor Layout Language Stored Pos Configurator Display Layout Configurator NUM 3. To edit and arrange the positions to your needs and to your examination practice: • Select a position and click the up or down arrow to change the sort order. Preview • Select the position and click Rename to rename a position (which is not protected). OR PostON Pen Postión Parking Pousen • Select the position and click Enable Write Protection or Disable Write Protection for writing LAO CRAN 28º 21 -29 cm a protection or not. Select the position and click Copy to System Positions or Copy to Anatomical Positions to T • copy a position to the other list. • Click the Undo or Redo icon to undo or redo the last action. • Select the position and click Delete to delete a position (which is not protected). 4. You can also apply write protection to selected positions. 20 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 www.siemens-healthineers.com 21 Effective Date: 07/09/2020 | HOOD05162003102770 Unrestricted © Siemens Healthineers, 2019
- ARTIS one
- System Operation