ARTIS pheno VE20 2D Image Review and Post Processing Video
This video demonstrates how to review and post-process 2D images in the control room on your ARTIS pheno VE20.
Welcome to the Artis Fino 2D Postprocessing basics video. This video will guide you through the workflow to window images, scroll through images, loop through all scenes and access functions to post process images. You can access basic imaging functions with the right mouse. Click on the image. The options available depend on the selected image type. You can find further functions for adjusting the views of a scene or image in the image tab of the segment menu. For example, adjust the edge enhancement shutter, an image zoom anpan, flip the image vertically or horizontally and invert the image. You find the controls to review images at the bottom of the image segment. You can review scenes at the same frame rate as they were acquired, or you can slow down or speed up scene review depending on the acquisition, frame rate and system configuration. Please note for variable frame rate acquisitions the review speed cannot be changed. The acquisition mode and the acquired frame rate are displayed beneath the scroll bar. Press play to start the scene. Select the previous or next frame in the scene. Or use the slider to move to a point in this scene. Using the controls on the bottom left you can select the previous or next scene or image. You can review the studies so that scenes are played one after the other to loop the scenes select loop in the image tab of the segment menu. With windowing you can adapt the image to display the grayscale region of interest with optimal contrast and brightness conditions. There are several methods available for windowing images in the control room. To window the image using the mouse, press and hold the middle mouse button in the required image. To adjust the window center image brightness, move the mouse up and down. To adjust the window width image contrast, move the mouse left and right. You can also use your keyboard to adjust the window values. Press on the keys to adjust the image contrast and brightness. Additionally, you can adjust the window values from the image tab in the segment menu. Select the windowing icon. Drag the sliders to adjust image brightness and contrast.
PATIENT, cardiac cardiac y I cAuo y I CAuo •t o mGy RAO 6 OSA 4, T. Segment Menu tiént. Cardiac Patient. Cardiac cnt. Cardiac @ Siemens Healthcare GmbH, 2020 203±9995 0020329995 20329995 0329995 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be ARTIS pheno SIEMENS used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. Healthineers The Operator Manual shall be used as your main reference, in particular for relevant safety information 2D Image review and post 2D Image review and post processing like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. AM 20 A" 20 20 CARD
- artis
- pheno
- ve20 artispheno
- atris
- robotic
- c-arm
- angio
- angiography
- interventional
- surgery
- radiology
- image
- post-process
- 2d
- windowing
- measurements
- contrast
- brightness
- annotations
- scroll
- loop