ARTIS pheno VE20 Program Selection Control Room Video
This video demonstrates how to select and change the program in the control room on your ARTIS pheno VE20.
Welcome to the Artis Fino program selection video. This video demonstrates how to change a selected program from the control room. In addition, you will learn how to activate Block X Ray from the control room user interface. During patient registration, you select the procedure type. The procedure includes an acquisition protocol and a fluoroscopy or road map protocol. Additionally, a case flow may be assigned to a procedure. If you need to change the selected procedure or protocol, select program selection from the info area. The procedures are organized into body regions. If required, select the required body region. The procedures are in a list on the left. Use the scroll bar if necessary to see all of the procedures. If required, select the procedure. If you have the optional touchscreen monitor, you can select the procedure via touch with your fingertip. You can select the current acquisition protocol and the fluoroscopy protocol. The fluoroscopy protocols are arranged into sets of three known as fluoroscopy, triplets. You can change the current fluoroscopy set. Additionally, you can change the following parameters. Acquisition frame rate fluoroscopy pulse rate acquisition, scene length and the measure field. To block X Ray from the control room, select Block X Ray in program selection.
o: PATIENT, Siemens PATIENT, Siemens Healthineers •t RAO r CAuo CARE Program Selection Scheduler @ Siemens Healthcare GmbH, 2020 x.Ray C: Siemens Healthcare GmbH, 2020 Rog ion Acquisition Protocol Acquisition Protocol Patients till' Patient, Siemens Healthi n eerS till' Patient, Siemens Healthi n eers Medical Information Procedure Inforrnation Please note that the learning material is for training purposes only! FL OSA care For the proper use of the softw.vare or hardware, please always use the Operator Manual or Instructions For the proper use of the software or hardware, please always use the Operator Manual or Instructions ARTIS pheno Procedure for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be FL 6s0SA Head 4 care SIEMENS . SIEMENS used as training material only and shall by no means substitute the Operator Manual. Any material used in 4 care care Sots this training will not be updated on a regular basis and does not necessarily reflect the latest version of OSA OSA 2 9socT SS the software and hardware available at the time of the training. FL 25 FL 2.5 FL 7 S Institution Healthineers Frame Rate The Operator Manual shall be used as your main reference, in particular for relevant safety information Program Selection FL S like warnings and cautions. 15 7.5 FL 7 S 15 30 15 Note: Some functions shown in this material are optional and might not be part of your system. The FL 25 FL 5 FL The reproduction, transmission or distribution of this training or its contents is not permitted without information in this material contains general technical descriptions of specifications and options as well Sconc Longth Measure Field as standard and optional features that do not always have to be present in individual cases. express written authority. Offenders will be liable for damages. as standard and optional features that do not alvvays have to be present in individual cases. 40s 120 s FL coil Certain products, product related claims or functionalities described in the material (hereinafter collectively All names and data of patients, parameters and configuration dependent designations are fictional "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, and examples only. the future availability of said Functionalities in any specific country is not guaranteed. Please contact your All rights, including rights created by patent grant or registration of a utility model or design, are reserved. local Siemens Healthineers sales representative for the most current information.
- artis
- pheno
- ve20 artispheno
- atris
- robotic
- c-arm
- angio
- angiography
- interventional
- surgery
- radiology
- program
- selection
- acquisition
- fluoroscopy
- fluoro
- VE20